Main content 1 Menu 2 Search 3 Footer 4
+A
A
-A
High contrast
HOME JOURNAL CRITERIA NETWORK HELP ABOUT

Current criteria:

Regional:

WPRlM journal selection criteria(2023)

Minimum standards for the suspension and removal of WPRIM approved journals

Countries journal selection criteria:

Philippines

Submit your journal information>

Contact NJSCs>

Chinese Journal of Medical Physics

1984  to  Present  ISSN: 1005-202X

Articles

About

Year of publication

Save Email

Sort by

Best match
Relevance
PubYear
JournalTitle

DISPLAY OPTIONS

Format:

Per page:

Save citations to file

Selection:

Format:

Create file Cancel

Email citations

To:

Please check your email address first!

Selection:

Format:

Send email Cancel

357

results

page

of 36

1

Cite

Cite

Copy

Share

Share

Copy

Fast Volume Clipping of Medical Images on GPU

Zhiying ZHU ; Xianglei BU ; Xiaoshan LIN ; Yanli XU

Chinese Journal of Medical Physics.2010;27(2):1731-1733,1740. doi:10.3969/j.issn.1005-202X.2010.02.008

Objective: When the region of interest is somewhere in the middle of the volumetric data, it will be occluded by other regions of the volumetric data and will be hard to see in the reconstruction of volume rendering. In order to provide doctor with comprehensive, visual and accurate diagnostic information, fast volume dipping of medical images on GPU is proposed in the paper. Methods: The rapid volume clipping is achieved by combining the dipping algorithm with the fast volume rendering algorithm based on GPU. The technique is based on fast volume tendering of medical images on GPU. It works as follows: The space information of the section plane is sent to the shader. Then compare the position of the volume data sets with the section plane to decide whether the data is clipped or not. Our algorithm is different from the algorithm that clipping based on depth stencil. We can see the result that reconstructed from the data sets that remained from any position as long as the section plane is defined. Results: According to the shape the users defined, our algorithm can decide which parts of the volume have to be clipped. Because of using the general graphics hardware acecleration, the proposed method achieves interactive display rate. Conclusions: The experiment shows that the algorithm is significantly fast and can meet the requirements of real-time interactive rendering on the premise of ensuring imaging quality and can be used in surgery simulation and so on.

2

Cite

Cite

Copy

Share

Share

Copy

Photodynamic Therapy and Sonodynamic Therapy

Weina LI ; Jiqing YANG ; Yuansheng LIU ; Xuemin QU ; Jun WEN ; Min ZHANG

Chinese Journal of Medical Physics.2010;27(2):1781-1784,1792. doi:10.3969/j.issn.1005-202X.2010.02.021

Objective: This paper summarized the research status and progress of photodynamic therapy (PDT) and sonodynam-ic therapy (SDT), and we hope this can be a useful reference for clinics or research. Methods: In this review we expound their molecular mechanisms in detail and classify the photosensitizer and sonosensitizer, indicate their applications for the cancer treatment and summarize their new treating modes. PDT and SDT have huge potential for cancer treatment. Results: PDT and SDT have achieved a certain results, whereas there are still many problems, such as tissue oxygen content, new photosensitizer and sonosensitizer, drug dosage and mechanisms of SDT. Conclusions: PDT and SDT, which are new methods for treating cancer, have shown a good application prospect. But PDT has not been universal in clinics and SDT is still in the experiment stage.

3

Cite

Cite

Copy

Share

Share

Copy

The study of EEG telemetry technology

Song PENG ; Zuxiang FANG ; Cuiwei YANG ; Qiang LUO

Chinese Journal of Medical Physics.2000;17(4):205-208,210. doi:10.3969/j.issn.1005-202X.2000.04.006

This Paper brings forward a new technology of EEG Telemetry. Using two FDM channels, the signals can be transmitted through public telephone lines: the EEG signals are transmitted by TDM technology in one channel; the parametes are transmitted to the receiver for identification of data or synchronization in the other channel synchronously. This technology can satisfy almost any routine clinic needs, and also the quahty of transmission is nearly perfect: the distortion is little; distinct noise pollution and shift of base-line do not exist, which is valuable in medical application.

4

Cite

Cite

Copy

Share

Share

Copy

Changes of macrophages stimulated by ConA after hyperthermia

Hong WANG ; Lin YANG ; Shenqiu LUO ; Xiaodong MA

Chinese Journal of Medical Physics.2001;18(1):42-43,45. doi:10.3969/j.issn.1005-202X.2001.01.019

Changes of rats peritoneal macrophages after hyperthermia were stimulated by ConA with ACAS 570 Interactive Laser Cytometer. The results show that the influx of Ca2+ increased further and the macrophages endocytosis enhanced the lysosomal pH fluctuated quickly, which was benefit for lysosomal content excretion, thus enhanced the lysosome activity.

5

Cite

Cite

Copy

Share

Share

Copy

Dosimetric Comparison of Inverse Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Non-Ssmall Cell Lung Cancer

Fuli ZHANG ; Weidong XU ; Junmao GAO ; Jianping CHEN ; Ping WANG ; Mingmin ZHENG

Chinese Journal of Medical Physics.2010;27(2):1704-1707,1720. doi:10.3969/j.issn.1005-202X.2010.02.002

Objective: To compare inverse three-dimensional conformal radiotherapy (Inv 3D-CRT) and intensity modulated ra-diotherapy (IMRT) for non-small cell lung cancer. Methods: For a cohort of 10 patients, Inv 3D-CRT and three groups of IMRT plannings were designed for per patient. The prescribed dose was 60 Gy/2 Gy/30f, 95% of the planning target volume received this dose. Dose was computed with a commercially available TPS using convolution/superposition (CS) algorithm. Plans were compared according to the PTV_(95)V_(20) ratio (PTV_(95)V_(20)) and D_(max)-D_(min). Results: Compared with Inv 3D-CRT, the PTV_(95)V_(20) ratio of three groups of IMRT increased by 1.08 (P = 0.014), 0.72 (P = 0.089) and 0.42 (P = 0.318), respectively. Conclusions: For NSCLC, IMRT can reduce the dose to the lungs compared with inverse 3D-CRT by improving the conformity of the plan and is worth spreading in clinical work.

6

Cite

Cite

Copy

Share

Share

Copy

Study on effect of base-material to distribution of microwave field

Jiancai ZHAI ; Liqung SHI ; Xianguang MA

Chinese Journal of Medical Physics.2000;17(4):225-226,228. doi:10.3969/j.issn.1005-202X.2000.04.014

A free space condition for the microwave radiation field for research will be needed, but different application microwave rields are not easy to satisfy this condition for the existence of interfaces of different medium. In the research, metal materials, insulator materials and ground materials are used as base-material to examine their effects upon the distribution of microwave field. Some rules are discovered.

7

Cite

Cite

Copy

Share

Share

Copy

Study on distribution of blood pressure in the cardiovascular system of rat

Qiushi ZHANG ; You ZHANG ; Yuming II ; Cheng ZHANG

Chinese Journal of Medical Physics.2000;17(4):243-244,246,248. doi:10.3969/j.issn.1005-202X.2000.04.022

Purpose:To study the distribution of blood pressure in the cardiovascular system of rat. Method:The experimental animal is Wistar rat (n=lS). The blood pressure in different parts of the cardiovascular system were recorded with a 4-channel polygraph system under closing condition. This method is more exact than that of manometer. Results:Our experiments demonstrated the following distribution of blood pressure in the cardiovascular system of rat. (1) The left ventricular systolic pressure(LVSP ) was 145.00+15.16 mmHg and the aortal systolic pressure(ASP ) was 126.87+11.16 mmHg. The LVSP was higher than ASP. The right ventricular systolic pressure(RVSP ) was 35.04+3.95 mrnHg and the pulmonary arterial systolic pressure(PASP) was 27.0313.46 mmHg. The RVSP was higher than PASP. This distribution of blood pressure was different with human. (2) On Value and range, the blood pressure in vascular system of rat (including A SP、A DP、MA P、PA SP、PA DP、MPA P、CVP、 WP)were clese to human. Conclusion: (1) The LVSPwas higher than ASP and the RVSP was higher than PASP. This distribution of blood pressure of rat was different with human. (2) The LVSP and RVSP of rat were higher when compared with human and the blood pressure distribution of other parts in the vascular system of rat was close to human

8

Cite

Cite

Copy

Share

Share

Copy

Research of Functional Connectivity Based on Independent Component Analysis and Temporal Correlation Analysis

Xinmei XU ; Huinan WANG ; Wei HUANG

Chinese Journal of Medical Physics.2008;25(1):477-480,483.

Objective: Combining spatial independent component analysis (sICA) with temporal correlation analysis to investigate the functional connectivity of human brain using resting state fMRI. Methods: First, activated area was localized by performing sICA on the data from block design run, then one of the activated brain areas was chosen as a region of interest (ROI)and low frequency correlations between ROI and other regions were calculated in resting state to detect the functional connectivity networks. To validate the method, neural connectivity to primary motor cortex was assessed using this method during a resting state. Results: Functional connectivity network of motor cortex was detected, including primary motor cortex (M1), supplementary motor area (SMA), primary sensory cortex (S1), dorsal premotor cortex (PMd) and posterior parietal somatosensory association area (PSAAp). The connectivity implied by the resting state correlation was far more similar to the connectivity established by non-imaging methods. Conclusion: Functional connectivity of human motor primary cortex was investigated by combining sICA with temporal correlation using resting fMRI data. It provided a simple and noninvasive method for the research of brain functional connectivity.

9

Cite

Cite

Copy

Share

Share

Copy

The development and clinical application of high-efficiency and new-type microwave internal cavity radiator

Yiqiang MIAO ; Yunya GAO ; Juexian ZHANG ; Honsen QIAN

Chinese Journal of Medical Physics.2000;17(4):229-230,234. doi:10.3969/j.issn.1005-202X.2000.04.016

For raising the efficiency of microwave radiation, reducing radiating dosage and shortening therapeutic time, the key is to design a new type and high effective microwave radiator. This paper describes the improvement and clinical effect of the new internal cavity radiator and circular cervical radiator. These two typies of radiator are wisely used in the hospitals. They have been marked therapeutics effects.

10

Cite

Cite

Copy

Share

Share

Copy

Effect of low-intensity millimeter wave on the biophysics characteristics of erythroeyte

Ying WU ; Shengli LAI

Chinese Journal of Medical Physics.2001;18(1):33-34,48. doi:10.3969/j.issn.1005-202X.2001.01.015

Low intensity millimeter(6mm,50GHz,100mW) wave was used to irradiate to 15 blood samples. The radiation time respectively were 15min、30min and 60min.Series rheological and biophysical parameters about the erythrocyte were systemically tested. There included viscosity of blood 、deformability and congregating ability of erythrocyte、hemolysical fragility 、anion transport in erythrocyte membranes and configuration of erythrocyte etc. From the point of biophysics, the biological effects of low intensity MMW to cells were investigated.

Country

China

Publisher

南方医科大学; 中国医学物理学会

ElectronicLinks

http://zgyxwlxzz.paperopen.com/

Editor-in-chief

E-mail

YXWL@263.net.cn

Abbreviation

Chinese Journal of Medical Physics

Vernacular Journal Title

中国医学物理学杂志

ISSN

1005-202X

EISSN

Year Approved

2016

Current Indexing Status

Currently Indexed

Start Year

1984

Description

Related Sites

WHO WPRO GIM

Help Accessibility
DCMS Web Policy
CJSS Privacy Policy

Powered by IMICAMS( 备案号: 11010502037788, 京ICP备10218182号-8)

Successfully copied to clipboard.