1.Regulation of osteogenic effects by bone morphogenetic protein/Wnt signaling pathway:revealing molecular mechanisms of bone formation and remodeling
Haowen LIU ; Weiping QIAO ; Zhicheng MENG ; Kaijie LI ; Xuan HAN ; Pengbo SHI
Chinese Journal of Tissue Engineering Research 2025;29(3):563-571
BACKGROUND:Osteoblasts are the main cell types responsible for bone formation and remodeling,and the normal performance of their function is precisely regulated by various signaling pathways.Among them,the bone morphogenetic protein and Wnt signaling pathways play a key role in osteogenesis. OBJECTIVE:To review the role of bone morphogenetic protein/Wnt signaling pathway in the regulation of osteoblast function and analyze its changes in different physiological and pathological conditions in order to further reveal the molecular mechanism of bone formation and remodeling. METHODS:The Chinese and English search terms"BMP signaling pathway,Wnt signaling pathway,and osteogenesis"were searched in CNKI,Wanfang,and PubMed databases for original researches published from the inception to June 2023.Totally 61 articles were finally selected for analysis and summary.Using the method of the literature review,the studies of the bone morphogenetic protein/Wnt signaling pathway in regulating osteogenesis were sorted out and analyzed. RESULTS AND CONCLUSION:(1)Bone morphogenetic protein and Wnt signaling pathways play important roles in the differentiation,proliferation,and maturation of osteoblasts.Bone morphogenetic protein signaling pathway mainly regulates the expression of osteogenesis-related genes through the activation of Smad protein.Smad protein enters the nucleus and regulates the expression of genes related to osteogenesis.Different Wnt signaling pathway from bone morphogenetic protein mainly depends on the activation of β-catenin to exert its biological effects.(2)The regulatory effect of bone morphogenetic protein/Wnt signaling pathway will be affected by many factors in different physiological and pathological states.Growth factors,hormones,and mechanical stress can affect the activity of bone morphogenetic protein/Wnt signaling pathway to some extent.(3)Bone morphogenetic protein/Wnt signaling pathway interacts with other signaling pathways in the regulation of osteogenesis,and they together constitute a complex regulatory network.(4)Chinese medicine and natural compounds can promote bone health by regulating signaling pathways,providing new possibilities for treating bone diseases.(5)Future studies can further explore the interaction of bone morphogenetic protein/Wnt signaling pathway and other signaling pathways and its changes in different physiological and pathological conditions,resolve the key nodes and regulation mechanism in the complex network,to provide more precise targets for the treatment of bone-related diseases,and also provide new ideas to reveal the molecular mechanism of bone formation and remodeling.
2.Environmental contamination status of norovirus outbreaks in schools and nurseries in Linhai City
ZHENG Jianjun, WANG Xi,HONG Danyang, LI Yaling, XU Qiumeng, ZHANG Huili, HAN Qian, LU Da, ZHENG Qiao
Chinese Journal of School Health 2025;46(4):601-603
Objective:
To investigate the environmental contamination of norovirus in nurseries and primary/secondary schools, so as to provide a scientific basis for effective prevention and control measures.
Methods:
A total of 483 external environmental samples were collected from 34 cluster outbreaks of norovirus gastroenteritis in kindergartens and primary/secondary schools in Linhai City from 2021 to 2024. Pathogen detection was conducted using a rapid nucleic acid extraction kit and realtime fluorescence RT-PCR, and the results were analyzed using the χ2 test or Fishers exact test.
Results:
Among the collected external environmental samples, the total positive rate of surface contamination was 13.66%. The positive rates in kindergartens and primary/secondary schools were 12.20% and 15.82%, respectively. In kindergartens, the five surfaces with the highest detection rates were desks/chairs (23.33%), toilet stool troughs (20.69%), urinal troughs (12.00%), washbasins/sinks (11.11%), and toilet mops (9.38%). In primary/secondary schools, the top five were toilet stool troughs (38.30%), urinal troughs (23.53%), toilet door handles (13.04%), toilet mops (12.50%), and drinking cups (11.11%). The difference in positive detection rates among different external environments in primary/secondary schools was statistically significant (Fishers exact probability test, P<0.01). The positive detection rate in sanitary toilets was higher than that in classroom environments (χ2=17.38), while the positive detection rate in classroom environments of kindergartens was higher than that in primary/secondary schools (χ2=5.42)(P<0.05).
Conclusions
Norovirus exhibits a high contamination rate in nurseries and schools, particularly in restroom areas. Strengthening sanitation and disinfection in highrisk environments, and improving hygiene awareness among children and staff, are essential for the effective prevent and control of norovirus.
3.Endovascular Treatment for Acute Posterior Circulation Tandem Lesions: Insights From the BASILAR and PERSIST Registries
Wei LI ; Mohamed F. DOHEIM ; Zhongming QIU ; Tan WANG ; Zhibin CHEN ; Wenjie ZI ; Qingwu YANG ; Haitao GUAN ; Hongyu QIAO ; Wenhua LIU ; Wei HU ; Xinfeng LIU ; Jinbo HUANG ; Zhongkui HAN ; Zhonglun CHEN ; Zhenqiang ZHAO ; Wen SUN ; Raul G. NOGUEIRA
Journal of Stroke 2025;27(1):75-84
Background:
and Purpose Limited evidence exists on the effectiveness of endovascular treatment (EVT) for acute posterior circulation tandem lesion (PCTL). This study aimed to explore the role of extracranial vertebral artery (VA) stenting in patients with PCTL stroke undergoing EVT.
Methods:
Individual patient data were pooled from the BASILAR (EVT for Acute Basilar Artery Occlusion Study) and PERSIST (Posterior Circulation Ischemic Stroke) registries. Patients with PCTLs who underwent EVT were included in the present cohort and divided into the stenting and nonstenting groups based on the placement of extracranial VA stents. The primary efficacy outcome was the modified Rankin Scale (mRS) scores at 90 days and 1 year. Safety outcomes included 24-hour symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days and 1 year post-surgery.
Results:
A combined dataset of 1,320 patients with posterior circulation artery occlusion, including 263 (19.9%) with tandem lesions, of whom 217 (median age, 65 years; 82.9% male) met the inclusion criteria for the analysis. The stenting group had 84 (38.7%) patients, while the non-stenting group had 133 (61.3%). After adjustment for the potential confounders, extracranial VA stenting was associated with favorable shifts in mRS scores at both 90 days (adjusted common odds ratio [OR], 2.30; 95% confidence interval [CI], 1.23–4.28; P<0.01) and 1 year (adjusted OR [aOR], 2.04; 95% CI [1.05–3.97]; P=0.04), along with lower rate of mortality at both 90 days (aOR, 0.45; 95% CI [0.21–0.93]; P=0.01) and 1 year (aOR, 0.36; 95% CI [0.16–0.79]; P=0.01), with no significant difference in sICH incidence (aOR, 0.35; 95% CI [0.06–1.98]; P=0.24).
Conclusion
Extracranial VA stenting during EVT may improve functional outcomes and reduce mortality in patients with PCTL strokes.
4.Endovascular Treatment for Acute Posterior Circulation Tandem Lesions: Insights From the BASILAR and PERSIST Registries
Wei LI ; Mohamed F. DOHEIM ; Zhongming QIU ; Tan WANG ; Zhibin CHEN ; Wenjie ZI ; Qingwu YANG ; Haitao GUAN ; Hongyu QIAO ; Wenhua LIU ; Wei HU ; Xinfeng LIU ; Jinbo HUANG ; Zhongkui HAN ; Zhonglun CHEN ; Zhenqiang ZHAO ; Wen SUN ; Raul G. NOGUEIRA
Journal of Stroke 2025;27(1):75-84
Background:
and Purpose Limited evidence exists on the effectiveness of endovascular treatment (EVT) for acute posterior circulation tandem lesion (PCTL). This study aimed to explore the role of extracranial vertebral artery (VA) stenting in patients with PCTL stroke undergoing EVT.
Methods:
Individual patient data were pooled from the BASILAR (EVT for Acute Basilar Artery Occlusion Study) and PERSIST (Posterior Circulation Ischemic Stroke) registries. Patients with PCTLs who underwent EVT were included in the present cohort and divided into the stenting and nonstenting groups based on the placement of extracranial VA stents. The primary efficacy outcome was the modified Rankin Scale (mRS) scores at 90 days and 1 year. Safety outcomes included 24-hour symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days and 1 year post-surgery.
Results:
A combined dataset of 1,320 patients with posterior circulation artery occlusion, including 263 (19.9%) with tandem lesions, of whom 217 (median age, 65 years; 82.9% male) met the inclusion criteria for the analysis. The stenting group had 84 (38.7%) patients, while the non-stenting group had 133 (61.3%). After adjustment for the potential confounders, extracranial VA stenting was associated with favorable shifts in mRS scores at both 90 days (adjusted common odds ratio [OR], 2.30; 95% confidence interval [CI], 1.23–4.28; P<0.01) and 1 year (adjusted OR [aOR], 2.04; 95% CI [1.05–3.97]; P=0.04), along with lower rate of mortality at both 90 days (aOR, 0.45; 95% CI [0.21–0.93]; P=0.01) and 1 year (aOR, 0.36; 95% CI [0.16–0.79]; P=0.01), with no significant difference in sICH incidence (aOR, 0.35; 95% CI [0.06–1.98]; P=0.24).
Conclusion
Extracranial VA stenting during EVT may improve functional outcomes and reduce mortality in patients with PCTL strokes.
5.Endovascular Treatment for Acute Posterior Circulation Tandem Lesions: Insights From the BASILAR and PERSIST Registries
Wei LI ; Mohamed F. DOHEIM ; Zhongming QIU ; Tan WANG ; Zhibin CHEN ; Wenjie ZI ; Qingwu YANG ; Haitao GUAN ; Hongyu QIAO ; Wenhua LIU ; Wei HU ; Xinfeng LIU ; Jinbo HUANG ; Zhongkui HAN ; Zhonglun CHEN ; Zhenqiang ZHAO ; Wen SUN ; Raul G. NOGUEIRA
Journal of Stroke 2025;27(1):75-84
Background:
and Purpose Limited evidence exists on the effectiveness of endovascular treatment (EVT) for acute posterior circulation tandem lesion (PCTL). This study aimed to explore the role of extracranial vertebral artery (VA) stenting in patients with PCTL stroke undergoing EVT.
Methods:
Individual patient data were pooled from the BASILAR (EVT for Acute Basilar Artery Occlusion Study) and PERSIST (Posterior Circulation Ischemic Stroke) registries. Patients with PCTLs who underwent EVT were included in the present cohort and divided into the stenting and nonstenting groups based on the placement of extracranial VA stents. The primary efficacy outcome was the modified Rankin Scale (mRS) scores at 90 days and 1 year. Safety outcomes included 24-hour symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days and 1 year post-surgery.
Results:
A combined dataset of 1,320 patients with posterior circulation artery occlusion, including 263 (19.9%) with tandem lesions, of whom 217 (median age, 65 years; 82.9% male) met the inclusion criteria for the analysis. The stenting group had 84 (38.7%) patients, while the non-stenting group had 133 (61.3%). After adjustment for the potential confounders, extracranial VA stenting was associated with favorable shifts in mRS scores at both 90 days (adjusted common odds ratio [OR], 2.30; 95% confidence interval [CI], 1.23–4.28; P<0.01) and 1 year (adjusted OR [aOR], 2.04; 95% CI [1.05–3.97]; P=0.04), along with lower rate of mortality at both 90 days (aOR, 0.45; 95% CI [0.21–0.93]; P=0.01) and 1 year (aOR, 0.36; 95% CI [0.16–0.79]; P=0.01), with no significant difference in sICH incidence (aOR, 0.35; 95% CI [0.06–1.98]; P=0.24).
Conclusion
Extracranial VA stenting during EVT may improve functional outcomes and reduce mortality in patients with PCTL strokes.
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Clinical efficacy of transcatheter tricuspid valve replacement in cardiac implantable electronic lead-related tricuspid regurgitation: A multi-center retrospective cohort study
Jingyi CAO ; Xiaoping NING ; Ning LI ; Fan QIAO ; Fan YANG ; Bailing LI ; Guangwei ZHOU ; Lin HAN ; Zhiyun XU ; Fanglin LU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):818-825
Objective To analyze the clinical efficacy of transcatheter tricuspid valve replacement (TTVR) in cardiac implantable electronic lead-related tricuspid regurgitation (TR). Methods The patients with severe TR who underwent LuX-Valve TTVR in 9 Chinese medical centers from June 2020 to August 2021 were retrospectively enrolled. They were divided into a cardiac implantable electronic device (CIED) group and a non-CIED group based on whether they had pre-existing CIED implantation. Success of the procedure was defined as safe implantation of the LuX-Valve and complete withdrawal of the delivery system. Prognostic improvement was defined as a decrease of TR grade to≤2+ and an improvement of cardiac function by≥2 grades. Surgical success and postoperative prognosis were compared between the two groups. Results A total of 190 patients were collected, including 50 males and 140 females with a mean age of 66.2±7.8 years. There were 29 patients in the CIED group, and 161 patients in the non-CIED group. In the CIED group, 28 patients were implanted with a permanent pacemaker and 1 patient with a cardioverter-defibrillator. Preoperative New York Heart Association (NYHA) cardiac function class, TR degree, left ventricular ejection fraction, tricuspid annular plane systolic excusion, and cardiac risk scores were comparable between the two groups (P>0.05). Postoperative TR was reduced to≤2+ in all patients, and there was no statistical difference in the incidence of perivalvular leakage between the two groups (P=0.270). Postoperative CT of CIED patients showed the valve was in place, and the lead was not extruded, twisted, or deflected. The in-hospital mortality of the two groups were 10.3% and 1.9%, respectively, and the difference was statistically significant (P=0.047). In addition, there was no statistical difference between the two groups in terms of postoperative improvement of cardiac function and mortality in the 1- and 2-year follow-up. Conclusion TTVR is feasible, safe, and effective in patients with CIED implantation, and the pre-existing lead has no significant effect on the clinical efficacy.


Result Analysis
Print
Save
E-mail