1.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
2.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
3.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
4.Remote Virtual Companion via Tactile Codes and Voices for The People With Visual Impairment
Song GE ; Xuan-Tuo HUANG ; Yan-Ni LIN ; Yan-Cheng LI ; Wen-Tian DONG ; Wei-Min DANG ; Jing-Jing XU ; Ming YI ; Sheng-Yong XU
Progress in Biochemistry and Biophysics 2024;51(1):158-176
ObjectiveExisting artificial vision devices can be divided into two types: implanted devices and extracorporeal devices, both of which have some disadvantages. The former requires surgical implantation, which may lead to irreversible trauma, while the latter has some defects such as relatively simple instructions, limited application scenarios and relying too much on the judgment of artificial intelligence (AI) to provide enough security. Here we propose a system that has voice interaction and can convert surrounding environment information into tactile commands on head and neck. Compared with existing extracorporeal devices, our device can provide a larger capacity of information and has advantages such as lower cost, lower risk, suitable for a variety of life and work scenarios. MethodsWith the latest remote wireless communication and chip technologies, microelectronic devices, cameras and sensors worn by the user, as well as the huge database and computing power in the cloud, the backend staff can get a full insight into the scenario, environmental parameters and status of the user remotely (for example, across the city) in real time. In the meanwhile, by comparing the cloud database and in-memory database and with the help of AI-assisted recognition and manual analysis, they can quickly develop the most reasonable action plan and send instructions to the user. In addition, the backend staff can provide humanistic care and emotional sustenance through voice dialogs. ResultsThis study originally proposes the concept of “remote virtual companion” and demonstrates the related hardware and software as well as test results. The system can not only achieve basic guide functions, for example, helping a person with visual impairment to shop in supermarkets, find seats at cafes, walk on the streets, construct complex puzzles, and play cards, but also can meet the demand for fast-paced daily tasks such as cycling. ConclusionExperimental results show that this “remote virtual companion” is applicable for various scenarios and demands. It can help blind people with their travels, shopping and entertainment, or accompany the elderlies with their trips, wilderness explorations, and travels.
5.Establishment and application of intravenous drug resolvent generation system and solvent incompatibility rules library
Ying HUANG ; Peifang LI ; Decai DU ; Ming FANG ; Sheng LIU
China Pharmacy 2024;35(14):1786-1789
OBJECTIVE To standardize the use of sterile powder for injection redissolution solvent and intravenous drugs diluent solvent, and ensure the safety of clinical drug use. METHODS The intravenous drug resolvent generation system and the intravenous drug solvent incompatibility rules library were constructed and operated by prescription-checking pharmacist team in our hospital by formulating a list of intravenous drugs needed to be dissolved with sterilized water for injection and a contraindication list of intravenous solvent compatibility. The unreasonable medical orders reviewed and intervened in our hospital from January to April 2023 (before the implementation of the intravenous drug solvent incompatibility rules library) and from May to August 2023 (after the implementation) were analyzed statistically to compare the number of unreasonable solvent selection orders, interception rate, and the success rate of pharmacists’ interventions for unreasonable solvent selection orders before and after the implementation. RESULTS Before the implementation of the solvent incompatibility rules library, a total of 5 229 groups of medical orders with unreasonable solvent selection in our hospital were identified, among which there were 1 204 groups of seriously unreasonable medical orders, with interception rate of 23.03% and the success rate of pharmacists’ intervention of 15.90%. After the implementation of the solvent incompatibility rules library, the total number of medical orders with unreasonable solvent selection was 3 258 groups, among which there were 1 148 groups of seriously unreasonable medical orders, with interception rate of 35.24% and success rate of pharmacists’ intervention of 24.83%, being significantly higher than before implementation (P<0.01 or P<0.001). CONCLUSIONS The establishment and application of the intravenous drug resolvent generation system and the solvent incompatibility rules library can significantly increase the interception rate of unreasonable solvent selection orders and the success rate of pharmacists’ interventions, and ensure the safety of clinical drug use.
6.Effects of Astragaloside Ⅳ on cardiac hypertrophy in rats with chronic heart failure based on PI3K/Akt/GSK3β signaling pathway
Lin-Yan WANG ; Chao LI ; Ming-Yi MA ; Xiao-Sheng SHENG
The Chinese Journal of Clinical Pharmacology 2024;40(1):57-61
Objective To investigate the effects of astragaloside Ⅳ on cardiac hypertrophy in chronic heart failure(CHF)rats,and the regulation of phosphoinositol-3-kinase/protein kinase B/glycogen synthase kinase 3 β(PI3K/Akt/GSK3β)signaling pathway.Methods CHF rat model was established by anterior descending coronary artery ligation,and randomly divided into model group,control group and experimental-L,-M,-H groups,with 8 rats in each group.Another 8 rats were hooked up without ligature as blank group.The experimental-L,-M,-H groups were given 20,40 and 80 mg·mL-1 astragaloside solution according to the dose of 5 mL·kg-1.The control group was given 1.50 mg·kg-1 lisinopril solution at a dose of 5 mL·kg-1.Both blank group and model group were given equal volume of 0.9%NaCl.Six groups of rats were given the drug once a day for 8 weeks by intragastric administration.The cardiac function of rats was measured by echocardiography,the cross-sectional area of cardiomyocytes was observed by wheat embryo lectin staining,and the expression levels of PI3K,Akt and GSK3β were detected by Western blot.Results The left ventricular ejection fraction of experimental-H,control,model and blank groups were(66.27±5.18)%,(67.75±4.98)%,(46.67±3.68)%and(81.65±6.46)%;left ventricular end-diastolic diameter was(0.53±0.05),(0.55±0.05),(0.45±0.02)and(0.57±0.05)mm;the cross-sectional areas of cardiomyocytes were(1.97±0.13),(1.61±0.18),(3.56±0.59)and(1.00±0.04)mm;the relative expression levels of phosphorylated PI3K protein were 0.45±0.04,0.71±0.07,0.11±0.02 and 0.85±0.06;the relative expression levels of phosphorylated Akt protein were 0.43±0.05,0.75±0.06,0.10±0.03 and 0.82±0.06;the relative expression levels of phosphorylated GSK3 β protein were 0.47±0.04,0.85±0.05,0.12±0.04 and 0.89±0.08,respectively.The above indexes of experimental-H group and control group were significantly different from those of model group(all P<0.05).Conclusion Astragaloside Ⅳ can improve cardiac dysfunction and inhibit myocardial hypertrophy in CHF rats,which may be related to the regulation of PI3 K/Akt/GSK3 β signaling pathway.
7.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.
8.Study on long-term toxicity of Tripterygium glycosides tablets based on type Ⅱ collagen-induced arthritis model rats
Tian-Xiang YE ; Ming-Zhu SHI ; Wei-Dong YANG ; Yan-Ming WEI ; Hui-Fang LI ; Sheng-Hui CHENG
The Chinese Journal of Clinical Pharmacology 2024;40(9):1296-1300
Objective To observe the multi-system toxicity of Tripterygium glycosides tablets in rats with type Ⅱ collagen-induced arthritis(CIA).Methods Healthy SD rats were randomly divided into normal group,model group and experimental group,with 10 rats in each group.In addition to the normal group,the other groups were established collagen-induced arthritis model.After the first immunization,the normal group and the model group were given an equal volume of 0.3%sodium carboxymethyl cellulose solution,and the experimental group was given 72 mg·kg-1·d-1 Tripterygium glycosides solution,once a day for 6 weeks.On the 42 nd day,the blood routine of each group was detected and the organ index was calculated.The levels of liver,kidney function and sex hormones in rats were detected by enzyme-linked immunosorbent assay.The histopathological changes of liver,kidney,ovary and testis were observed by hematoxylin-eosin(HE)staining.Results The testicular indexes of the normal group,the model group and the experimental group were(0.81±0.05)%,(0.97±0.06)%and(0.81±0.12)%;the estradiol contents were(63.90±16.19),(55.42±7.23)and(40.04±5.97)pg·mL-1;the testosterone contents were(1 290.96±257.94),(1 198.43±190.77)and(912.62±61.72)pg·mL-1,respectively.There were statistically significant differences in the above indexes between the model group and the experimental group(P<0.01,P<0.05).HE pathological results showed that Tripterygium glycosides tablets could cause abnormal histopathological changes of ovary and testis in CIA model rats.Conclusion Continuous administration of 8-fold clinical equivalent dose of Tripterygium glycosides tablets for 6 weeks can cause damage to the reproductive system of CIA rats.
9.Clinical trial of lupatadine combined with azlastine hydrochloride nasal spray in the treatment of allergic rhinitis patients
Hong-Bin XU ; Ke-Liang LI ; Ke LI ; Mei WANG ; Lu-Lu HU ; Ming-Peng SUN ; Bu-Sheng TONG
The Chinese Journal of Clinical Pharmacology 2024;40(19):2822-2825
Objective To observe the clinical efficacy and safety of lupatadine tablets combined with azelastine hydrochloride nasal spray in the treatment of allergic rhinitis patients.Methods Patients with allergic rhinitis were randomly divided into control group and treatment group.Both groups received general treatment.On this basis,the control group was given azelastine hydrochloride nasal spray 0.14 mg per nostril each time,bid;on the basis of control group,the treatment group received lupatadine tablets 10 mg each time,orally,qd.Two groups were treated for 4 weeks.The clinical efficacy,rhinoconjunctivitis related quality of life questionnaire(RQLQ),serum indexes[interleukin-6(IL-6),IL-1 β,tumor necrosis factor-α(TNF-α),immunoglobulin E(IgE)]and safety were compared between the two groups.Results Treatment group were enrolled 53 cases,4 cases dropped out,and 49 cases were finally included in the statistical analysis.Control group were enrolled 53 cases,4 cases dropped out,and 49 cases were finally included in the statistical analysis.After treatment,the total effective rates of the treatment and control groups were 95.92%(47 cases/49 cases)and 81.63%(40 cases/49 cases)with significant difference(P<0.05).After treatment,the RQLQ scores of treatment and control groups were(49.57±6.97)and(58.18±7.78)points,IL-6 levels were(5.12±1.25)and(7.34±1.46)ng·L-1,IL-1 β levels were(12.25±5.64)and(20.05±6.32)pg·mL-1,TNF-α levels were(3.25±0.62)and(4.45±0.49)pg·mL-1,the IgE levels were(114.28±19.63)and(136.84±30.14)μg·L-1,respectively,the differences were statistically significant difference(all P<0.05).The adverse drug reactions of two groups were dry mouth,fatigue,dizziness and drowsiness.The total incidences of adverse drug reactions in the treatment and control groups were 16.33%and 10.20%without significant difference(P>0.05).Conclusion Lupatadine tablets combined with azostine hydrochloride nasal spray have a definitive clinical efficacy in the treatment of allergic rhinitis patients,which can effectively reduce the inflammatory reaction,reduce the IgE levels,improve the quality of life,without increasing the incidence of adverse drug reactions.
10.Effect of loading angle and fabrication materials on stress distribution with periodontal splint in compromised periodontal tissues: a finite element study
Ming FANG ; Yuchen LIU ; Sheng ZHONG ; Dongmei LI ; Tong YANG ; Shizhu BAI
Chinese Journal of Stomatology 2024;59(11):1120-1125
Objective:To evaluate the effect of polyetheretherketone (PEEK) periodontal splints and splints made from other materials under static loading on stress distributions in periodontal tissues, cement layer, and splints themselves.Methods:A finite element model based on cone-beam CT imaging data of a 25-year-old male patient (treated at the Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University in October 2021 for a cracked maxillary molar) with a healthy and intact mandibular dentition and periodontal health was constructed. The finite element model included anterior mandible dentition, mandibular bone model without bone resorption (WBR group), a periodontally compromised mandible model (control group), and three types of periodontal splints: a PEEK periodontal splint (0.7 mm thick, Young′s modulus: 4.1 MPa), a fiber-reinforced resin (FRC) splint (1.0 mm thick, Young′s modulus: 37.0 MPa), and a titanium splint (1.2 mm thick, Young′s modulus: 110.0 MPa). The bone resorption models fixed with different periodontal splints constituted the experimental groups (PEEK group, FRC group and titanium group). Loading of 100 N was applied on the midpoint of the incisal edge of tooth 41. The direction was set at 0°, which was parallel to the long axis of the tooth and downward. The buccal to lingual and downward angles were 30°and 60°, respectively, perpendicular to the long axis of the tooth and 90° to the lingual side. The finite element analysis software was utilized to analyze the stress distribution characteristics of the periodontal tissues, adhesive layer, and the splint itself in the anterior mandibular teeth among the different group.Results:Under the different loading simulation, in the control group, the maximal von Mises stresses of periodontal ligament and bone were 15.7-50.2 MPa and 38.8-130.3 MPa, respectively, and in the WBR group, the maximal von Mises stresses of periodontal ligament and bone were 3.6-6.4 MPa and 16.5-42.7 MPa, respectively. Under the same loading conditions, the magnitude of maximal von Mises stresses in periodontal tissues in the PEEK group was 4.6-6.2 MPa, and the magnitude of stresses in the periodontal ligament of 41 teeth in the WBR group was similar to that in the PEEK group, but higher than that in the FRC and titanium groups. The maximal von Mises stresses of each group is primarily distributed in the periodontal ligament and alveolar bone at the cervical area of the tooth. The higher the elastic modulus of the splint, the higher its own maximal von Mises stresses, and the smaller the maximal principal stresses transmitted to the adhesive layer. In the PEEK group and titanium group, the stress distribution area in the adhesive layer and the splint was near the splint connection adjacent to tooth 41.Conclusions:Periodontal splints fabricated from three types of materials, are effective in distributing stress within the periodontal tissues of the abutment teeth. Compared to FRC and titanium group, the higher PEEK splint stress value was obtained, and the smaller the stress value was transmitted to its adhesive layer.

Result Analysis
Print
Save
E-mail