1.The relationship between activities of daily living and mental health in community elderly people and the mediating role of sleep quality
Heng-Yi ZHOU ; Jing LI ; Dan-Hua DAI ; Yang LI ; Bin ZHANG ; Rong DU ; Rui-Long WU ; Jia-Yan JIANG ; Yuan-Man WEI ; Jing-Rong GAO ; Qi ZHAO
Fudan University Journal of Medical Sciences 2024;51(2):143-150
Objective To explore the relationship and internal path between activities of daily living(ADL),sleep quality and mental health of community elderly people in Shanghai.Methods A questionnaire survey was conducted among community residents aged 60 years and older seeing doctors in community health care center of five streets in Shanghai during Sept to Dec,2021 using convenience sampling.Activities of Daily Living(ADL),Pittsburgh Sleep Quality Index(PSQI)and 10-item Kessler Psychological Distress Scale(K10)were adopted in the survey.Single factor analysis,correlation analysis and multiple linear regression were used to analyze the data.The effect relationship between the variables was tested using Bootstrap's mediated effects test.Results A total of 1 864 participants were included in the study.The average score was 15.53±4.47 for ADL,5.60±3.71 for PSQI and 15.50±6.28 for K10.The rate of ADL impairment,poor sleep quality,poor and very poor mental health of the elderly were 23.6%,27.3%,11.9%and 4.9%,respectively.ADL and sleep quality were all positively correlated with mental health(r=0.321,P<0.001;r=0.466,P<0.001);ADL was positively correlated with sleep quality(r=0.294,P<0.001).Multiple linear results of factors influencing mental health showed that ADL(β= 0.457,95%CI:0.341-0.573),sleep quality(β =0.667,95%CI:0.598-0.737)and mental health were positively correlated(P<0.001).Sleep quality partially mediated the relationship between ADL and mental health(95%CI:0.078-0.124)with an effect size of 33.0%.Conclusion Sleep quality is a mediator between ADL and mental health among community elderly people.Improving ADL and sleep quality may improve mental health in the population.
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
6.Investigation and analysis of the current status of transjugular intrahepatic portosystemic shunt treatment for portal hypertension in China
Haozhuo GUO ; Meng NIU ; Haibo SHAO ; Xinwei HAN ; Jianbo ZHAO ; Junhui SUN ; Zhuting FANG ; Bin XIONG ; Xiaoli ZHU ; Weixin REN ; Min YUAN ; Shiping YU ; Weifu LYU ; Xueqiang ZHANG ; Chunqing ZHANG ; Lei LI ; Xuefeng LUO ; Yusheng SONG ; Yilong MA ; Tong DANG ; Hua XIANG ; Yun JIN ; Hui XUE ; Guiyun JIN ; Xiao LI ; Jiarui LI ; Shi ZHOU ; Changlu YU ; Song HE ; Lei YU ; Hongmei ZU ; Jun MA ; Yanming LEI ; Ke XU ; Xiaolong QI
Chinese Journal of Radiology 2024;58(4):437-443
Objective:To investigate the current situation of the use of transjugular intrahepatic portosystemic shunt (TIPS) for portal hypertension, which should aid the development of TIPS in China.Methods:The China Portal Hypertension Alliance (CHESS) initiated this study that comprehensively investigated the basic situation of TIPS for portal hypertension in China through network research. The survey included the following: the number of surgical cases, main indications, the development of Early-TIPS, TIPS for portal vein cavernous transformation, collateral circulation embolization, intraoperative portal pressure gradient measurement, commonly used stent types, conventional anticoagulation and time, postoperative follow-up, obstacles, and the application of domestic instruments.Results:According to the survey, a total of 13 527 TIPS operations were carried out in 545 hospitals participating in the survey in 2021, and 94.1% of the hospital had the habit of routine follow-up after TIPS. Most hospitals believed that the main indications of TIPS were the control of acute bleeding (42.6%) and the prevention of rebleeding (40.7%). 48.1% of the teams carried out early or priority TIPS, 53.0% of the teams carried out TIPS for the cavernous transformation of the portal vein, and 81.0% chose routine embolization of collateral circulation during operation. Most of them used coils and biological glue as embolic materials, and 78.5% of the team routinely performed intraoperative portal pressure gradient measurements. In selecting TIPS stents, 57.1% of the hospitals woulel choose Viator-specific stents, 57.2% woulel choose conventional anticoagulation after TIPS, and the duration of anticoagulation was between 3-6 months (55.4%). The limitation of TIPS surgery was mainly due to cost (72.3%) and insufficient understanding of doctors in related departments (77.4%). Most teams accepted the domestic instruments used in TIPS (92.7%).Conclusions:This survey shows that TIPS treatment is an essential part of treating portal hypertension in China. The total number of TIPS cases is far from that of patients with portal hypertension. In the future, it is still necessary to popularize TIPS technology and further standardize surgical indications, routine operations, and instrument application.
7.Clinical observation of levosimendan in the treatment of septic shock combined with myocardial depression
Fang XIONG ; Chao LIU ; Kexiang ZHANG ; Qilong ZHOU ; Hua LU ; Jianguo CHEN ; Xi YUE ; Jianxin ZHAO ; Pengfei PAN
China Pharmacy 2024;35(20):2517-2521
OBJECTIVE To explore the effects of levosimendan on cardiac function, hemodynamics and prognosis of patients with septic shock complicated with myocardial depression, and evaluate the safety of levosimendan. METHODS Patients with septic shock complicated with myocardial depression who were admitted to the Department of Critical Care Medicine of Chongqing University Three Gorges Hospital from April 2021 to August 2023, underwent adequate fluid resuscitation, had a mean arterial pressure (MAP) ≥65 mmHg, and received pulse indicator continuous cardiac output (PiCCO) monitoring were enrolled. The patients were randomly divided into dobutamine group and levosimendan group according to a random number table, with 20 patients in each group. Both groups received intravenous infusion of Norepinephrine bitartrate injection at a dose of 0.1-2.0 μg/(kg·min). On this basis, the dobutamine group additionally received intravenous infusion of Dobutamine hydrochloride injection at a dose of 5- 10 μg/(kg·min) for 3 to 7 days, while the levosimendan group additionally received intravenous infusion of Levosimendan injection at a dose of 0.1-0.2 μg/(kg·min) for 24 hours. Heart rate (HR) and hemodynamic parameters [systolic blood pressure, diastolic blood pressure, MAP, central venous pressure (CVP)], PiCCO monitoring parameters [cardiac function index (CFI), cardiac index (CI), stroke volume index (SVI), extravascular lung water index, global end-diastolic volume index, pulmonary vascular permeability index (PVPI), global ejection fraction (GEF), systemic vascular resistance index, left ventricular contractility index], and prognosis indicators [death within 3 days after administration, mechanical ventilation time,intensive care unit (ICU) stay time, 28-day mortality rate] were compared between the two groups before treatment and at 24 and 72 hours after treatment. Adverse reactions were E-mail:recorded for both groups. RESULTS Compared with before treatment in the same group, CFI, CI and GEF at 24 hours after treatment, CI and GEF at 72 hours after treatment in the dobutamine group, as well as SVI at 24 hours after treatment and SVI and GEF at 72 hours after treatment in the levosimendan group were significantly increased; PVPI at 72 hours after treatment in the dobutamine group was significantly decreased (P<0.05). Compared with the dobutamine group during the same period, patients in the levosimendan group had significantly lower HR and significantly higher CVP at 24 hours after treatment (P<0.05). Within 3 days after administration, there were no deaths in either group; there were no statistically significant differences in mechanical ventilation time, ICU stay time, 28-day mortality rate, or the incidence of adverse reactions between the two groups (P>0.05). CONCLUSIONS For patients with septic shock complicated with myocardial depression who have undergone adequate fluid resuscitation and have a MAP of ≥65 mmHg, levosimendan is comparable to dobutamine in improving cardiac function and hemodynamic parameters, without affecting patients’ prognosis or increasing the risk of adverse reactions such as hypotension.
8.Study and Practice on Intelligent Classification of Medical Safety Incidents Based on BERT Model
Congpu ZHAO ; Da YUAN ; Pujue ZHU ; Jiong ZHOU ; Zheng CHEN ; Hua PENG
Journal of Medical Informatics 2024;45(1):27-32,38
Purpose/Significance To improve the classification and evaluation mode of medical safety incidents,and to improve work efficiency and timeliness.Method/Process The data of previous medical safety incidents are pre-processed,BERT model is used for training,testing and iterative optimization,and an intelligent classification and prediction model for medical safety incidents is built.Re-sult/Conclusion The model is used to classify 466 medical safety incidents reported by clinical departments from January to November 2022,and F1 value reaches 0.66.The application of BERT model in the classification and evaluation of medical safety incidents can im-prove work efficiency and timeliness,and help timely intervene in medical safety risks.
9.The association between body mass index and in-hospital major adverse cardiovascular and cerebral events in patients with acute coronary syndrome
Qing ZHOU ; Dan ZHU ; Yiting WANG ; Wenyue DONG ; Jie YANG ; Jun WEN ; Jun LIU ; Na YANG ; Dong ZHAO ; Xinwei HUA ; Yida TANG
Chinese Journal of Cardiology 2024;52(1):42-48
Objective:To assess the association between body mass index (BMI) and major adverse cardiovascular and cerebrovascular events (MACCE) among patients with acute coronary syndrome (ACS).Methods:This was a multicenter prospective cohort study, which was based on the Improving Care for Cardiovascular Disease in China (CCC) project. The hospitalized patients with ACS aged between 18 and 80 years, registered in CCC project from November 1, 2014 to December 31, 2019 were included. The included patients were categorized into four groups based on their BMI at the time of admission: underweight (BMI<18.5 kg/m 2), normal weight (BMI between 18.5 and 24.9 kg/m 2), overweight (BMI between 25.0 and 29.9 kg/m 2), and obese (BMI≥30.0 kg/m 2). Multivariate logistic regression models was used to analyze the relationship between BMI and the risk of in-hospital MACCE. Results:A total of 71 681 ACS inpatients were included in the study. The age was (63.4±14.7) years, and 26.5% (18 979/71 681) were female. And the incidence of MACCE for the underweight, normal weight, overweight, and obese groups were 14.9% (322/2 154), 9.5% (3 997/41 960), 7.9% (1 908/24 140) and 7.0% (240/3 427), respectively ( P<0.001). Multivariate logistic regression analysis showed a higher incidence of MACCE in the underweight group compared to the normal weight group ( OR=1.30, 95% CI 1.13-1.49, P<0.001), while the overweight and obese groups exhibited no statistically significant difference in the incidence of MACCE compared to the normal weight group (both P>0.05). Conclusion:ACS patients with BMI below normal have a higher risk of in-hospital MACCE, suggesting that BMI may be an indicator for evaluating short-term prognosis in ACS patients.
10.Bioequivalence study of gliclazide sustained-release tablets in Chinese healthy subjects
Zhou-Ping DUAN ; Xiao-Wei ZHAO ; Jin-Hua WEN ; Shi-Bo HUANG ; Pu LI ; Duan-Wen CAO
The Chinese Journal of Clinical Pharmacology 2024;40(15):2241-2245
Objective To investigate the bioequivalence of gliclazide sustained-release tablets in Chinese healthy subjects.Methods The study was designed using a single-center,open,randomized,single-dose,two-cycle,two-sequence administration method;subjects were orally administered the test/reference preparation 30 mg on an fasting or fed conditions,with self-cross-dosing.The concentration of gliclazide in human plasma was determined by liquid chromatography tandem mass spectrometry(LC-MS/MS)method.The main pharmacokinetic parameters of gliclazide(Cmax,AUC0-t and AUC0-∞)were analyzed by non-atrioventricular model of WinNonlin.Result In the fasting study,24 subjects were recruited and 22 completed the study.The main pharmacokinetic parameters of gliclazide sustained-release tablets test preparation and reference preparation in the fasting group were as follows:Cmax were(862.48±294.48)and(902.96±259.09)ng·mL-1;AUC0-t were(2.60 × 104±8 930.46)and(2.50 ×104±7 573.42)h·ng-1·mL-1;AUC0-∞ were(3.00 × 104±1.43 × 104)and(2.68 × 104±7 085.99)h·ng·mL-1.In the fed study,twenty-four subjects were enrolled and 23 completed the study.The main pharmacokinetic parameters of gliclazide sustained-release tablets test preparation and reference preparation in fed group:Cmax were(1 531.74±273.49)and(1 510.87±241.08)ng·mL-1;AUC0-t were(2.78 ×104±9 565.89)and(2.76 ×104±9 821.43)h·ng·mL-1;AUC0-∞ were(3.02 ×104±1.24 ×104)and(3.02 × 104±1.30 × 104)h·ng·mL-1 h·ng·mL-1.The 90%confidence intervals of the geometric mean ratios of Cmax,AUC0-t,AUC0-∞ for the test preparation and reference preparation gliclazide sustained-release tablets were all between 80%and 125%.Conclusion The test and the reference preparation of gliclazide sustained-release tablets are bioequivalent in Chinese healthy subjects.

Result Analysis
Print
Save
E-mail