1.Updates and amendments of the Chinese Pharmacopoeia 2025 Edition (Volume Ⅰ)
LI Hao ; SHEN Mingrui ; ZHANG Pang ; ZHAI Weimin ; NI Long ; HAO Bo ; ZHAO Yuxin ; HE Yi ; MA Shuangcheng ; SHU Rong
Drug Standards of China 2025;26(1):017-022
The Chinese Pharmacopoeia is the legal technical standard which should be followed during the research, production, use, and administration of drugs. At present, the new edition of the Chinese Pharmacopoeia is planned to be promulgated and implemented. This article summarizes and analyzes the main characteristics and the content of updates and amendments of the Chinese Pharmacopoeia 2025 Edition(Volume Ⅰ), to provide a reference for the correct understanding and accurate implementation the new edition of the pharmacopoeia.
2.Body Composition Profiles and Associated Factors in Adolescents UndergoingLong-term Regular Exercise
Yutong WANG ; Xiaoyuan GUO ; Hanze DU ; Hui PAN ; Wei WANG ; Mei ZHANG ; Bo BAN ; Ping LI ; Xinran ZHANG ; Qiuping ZHANG ; Hongshuang SUN ; Rong LI ; Shi CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(3):591-597
To investigate body composition and associated factors in adolescents undergoing long-term regular sports training. This prospective longitudinal cohort study employed convenience sampling to recruit adolescents receiving structured athletic training at Jining Sports Training Center in June 2023. Baseline measurements included height, weight, body mass index (BMI), blood pressure, heart rate, waist circumference, and hip circumference. Questionnaires assessed sleep duration, screen time, and household income. Follow-up measurements in June 2024 repeated these assessments while adding bioelectrical impedance analysis for body composition (lean mass, skeletal muscle mass, fat mass, and body fat percentage). Linear regression models examined associations between training type (direct-contact vs. non-contact sports) and follow-up body fat percentage, BMI, and waist circumference as dependent variables, adjusting for covariates. The study included 110 adolescents (39 female, 71 male) with median age 13.21 years (IQR: 12.46-14.33). Participants comprised 65 direct-contact and 45 non-contact athletes. Baseline prevalence rates were 27.27% for overweight/obesity, 24.55% for elevated waist circumference, and 16.36% for elevated blood pressure. At follow-up, corresponding rates were 24.55%, 26.36%, and 13.64% respectively. The elevated blood pressure subgroup showed significantly higher waist circumference ( Despite regular athletic training, substantial proportions of adolescents exhibited overweight/obesity, abdominal obesity, and elevated blood pressure, warranting clinical attention. Training modality appears to influence body composition changes, with direct-contact sports associated with more favorable adiposity-related outcomes.
3.Confidential unit exclusion in Guangzhou from 2009 to 2022
Mingyue LIANG ; Hong LUO ; Boquan HUANG ; Bo HE ; Xiaoguang CHEN ; Xiaobin HUANG ; Xia RONG ; Weidong ZHANG
Chinese Journal of Blood Transfusion 2024;37(1):80-83
【Objective】 To investigate the condition of confidential unit exclusion(CUE) in Guangzhou, so as to ensure blood safety. 【Methods】 The number of CUE donors, demographic characteristics of CUE donors, reasons for CUE, and response time of CUE after blood donation in Guangzhou from 2009 to 2022 were statistically analyzed. 【Results】 From 2009 to 2022, the response ratios of CUE was 0.006 2% (260/4 170 984) and the ratios had statistically significant difference between different years(P<0.05). For the response ratios of CUE, no statistically significant difference was noticed in gender and occupation (P>0.05), but statistically significant differences were found in age, number of blood donations, education background, and marital status (P<0.05). Blood donors aged 18~30 (0.007 3%, P<0.05) and first-time blood donors (0.010 8%, P<0.05) were the main groups of CUE. High risk sexual behavior (28.46%, 74/260) was the primary reason for CUE. The CUE response peak was within 72 hours after blood donation, and the response ratios within 24-72 hours after blood donation was the highest (68.46%, 178/260). 【Conclusion】 CUE is a crucial measure to ensure blood safety. Detailed pre-donation health consultations are suggested for blood donors aged 18-30 and first-time blood donors so as to better excluding high-risk blood donors. Strengthening the publicity of CUE response and process, registering and classifying the reasons for CUE are also important.
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.National bloodstream infection bacterial resistance surveillance report (2022) : Gram-negative bacteria
Zhiying LIU ; Yunbo CHEN ; Jinru JI ; Chaoqun YING ; Qing YANG ; Haishen KONG ; Haifeng MAO ; Hui DING ; Pengpeng TIAN ; Jiangqin SONG ; Yongyun LIU ; Jiliang WANG ; Yan JIN ; Yuanyuan DAI ; Yizheng ZHOU ; Yan GENG ; Fenghong CHEN ; Lu WANG ; Yanyan LI ; Dan LIU ; Peng ZHANG ; Junmin CAO ; Xiaoyan LI ; Dijing SONG ; Xinhua QIANG ; Yanhong LI ; Qiuying ZHANG ; Guolin LIAO ; Ying HUANG ; Baohua ZHANG ; Liang GUO ; Aiyun LI ; Haiquan KANG ; Donghong HUANG ; Sijin MAN ; Zhuo LI ; Youdong YIN ; Kunpeng LIANG ; Haixin DONG ; Donghua LIU ; Hongyun XU ; Yinqiao DONG ; Rong XU ; Lin ZHENG ; Shuyan HU ; Jian LI ; Qiang LIU ; Liang LUAN ; Jilu SHEN ; Lixia ZHANG ; Bo QUAN ; Xiaoping YAN ; Xiaoyan QI ; Dengyan QIAO ; Weiping LIU ; Xiusan XIA ; Ling MENG ; Jinhua LIANG ; Ping SHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2024;17(1):42-57
Objective:To report the results of national surveillance on the distribution and antimicrobial resistance profile of clinical Gram-negative bacteria isolates from bloodstream infections in China in 2022.Methods:The clinical isolates of Gram-negative bacteria from blood cultures in member hospitals of national bloodstream infection Bacterial Resistant Investigation Collaborative System(BRICS)were collected during January 2022 to December 2022. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 software were used to analyze the data.Results:During the study period,9 035 strains of Gram-negative bacteria were collected from 51 hospitals,of which 7 895(87.4%)were Enterobacteriaceae and 1 140(12.6%)were non-fermenting bacteria. The top 5 bacterial species were Escherichia coli( n=4 510,49.9%), Klebsiella pneumoniae( n=2 340,25.9%), Pseudomonas aeruginosa( n=534,5.9%), Acinetobacter baumannii complex( n=405,4.5%)and Enterobacter cloacae( n=327,3.6%). The ESBLs-producing rates in Escherichia coli, Klebsiella pneumoniae and Proteus spp. were 47.1%(2 095/4 452),21.0%(427/2 033)and 41.1%(58/141),respectively. The prevalence of carbapenem-resistant Escherichia coli(CREC)and carbapenem-resistant Klebsiella pneumoniae(CRKP)were 1.3%(58/4 510)and 13.1%(307/2 340);62.1%(36/58)and 9.8%(30/307)of CREC and CRKP were resistant to ceftazidime/avibactam combination,respectively. The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)complex was 59.5%(241/405),while less than 5% of Acinetobacter baumannii complex was resistant to tigecycline and polymyxin B. The prevalence of carbapenem-resistant Pseudomonas aeruginosa(CRPA)was 18.4%(98/534). There were differences in the composition ratio of Gram-negative bacteria in bloodstream infections and the prevalence of main Gram-negative bacteria resistance among different regions,with statistically significant differences in the prevalence of CRKP and CRPA( χ2=20.489 and 20.252, P<0.001). The prevalence of CREC,CRKP,CRPA,CRAB,ESBLs-producing Escherichia coli and Klebsiella pneumoniae were higher in provinicial hospitals than those in municipal hospitals( χ2=11.953,81.183,10.404,5.915,12.415 and 6.459, P<0.01 or <0.05),while the prevalence of CRPA was higher in economically developed regions(per capita GDP ≥ 92 059 Yuan)than that in economically less-developed regions(per capita GDP <92 059 Yuan)( χ2=6.240, P=0.012). Conclusions:The proportion of Gram-negative bacteria in bloodstream infections shows an increasing trend,and Escherichia coli is ranked in the top,while the trend of CRKP decreases continuously with time. Decreasing trends are noted in ESBLs-producing Escherichia coli and Klebsiella pneumoniae. Low prevalence of carbapenem resistance in Escherichia coli and high prevalence in CRAB complex have been observed. The composition ratio and antibacterial spectrum of bloodstream infections in different regions of China are slightly different,and the proportion of main drug resistant bacteria in provincial hospitals is higher than those in municipal hospitals.
8.Study of phenylpropanoids from Tripterygium hypoglaucum
Zhi-qi LIN ; Hong-bo ZHU ; Tang ZHOU ; Ji WANG ; Rong-ping ZHANG ; Xing-long CHEN
Acta Pharmaceutica Sinica 2024;59(6):1730-1740
This paper aimed to study phenylpropanoids of
9.Cost-effectiveness analysis of chemical treatment with drones for Oncomelania hupensis control in marshland and lake areas
Yong CHEN ; Xiaojuan XU ; Daolong WEN ; Bo DAI ; Lan GAO ; Rong ZHANG ; Qingqing HUANG ; Linlin LI ; Fan ZHA ; Liang FANG ; Ping ZHANG ; Shiqing ZHANG ; Chunli CAO
Chinese Journal of Schistosomiasis Control 2024;36(5):502-506
Objective To evaluate the molluscicidal effect and cost of spraying molluscicides with drones against Oncomelania hupensis snails in marshland and lake areas, so as to provide new insights into field snail control in China. Methods A marshland and lake setting measuring approximately 12 000 m2 was selected in Wanzhi District, Wuhu City on June 2023 as the test field, and assigned to four groups, of 3 000 m2 in each group. Environmental cleaning was not conducted in groups A or B, which were given 5% niclosamide ethanolamine salt granules sprayed with knapsack-type sprayers and drones at a dose of 40 g/m2, and environmental cleaning was conducted in groups C and D, which were given 5% niclosamide ethanolamine salt granules sprayed with drones and knapsack-type sprayers at a dose of 40 g/m2, respectively. O. hupensis snails were surveyed before chemical treatment and 1, 3, 5, 7, 14 days post-treatment. The uniformity of chemicals was determined on the day of treatment, and the snail mortality, corrected snail mortality and density of living snails were calculated and compared among groups. The cost of molluscicides, labor fees of environmental cleaning and chemical treatment and cost of equipment were calculated, and the cost for a 1% reduction in the mean density of living snails was calculated 14 days post-treatment. Results The mean densities of living snails and mortality rates of snails were 1.82 to 2.85 snails/0.1 m2 and 1.41% to 2.94% in groups A, B, C and D before chemical treatment, and the mortality and corrected mortality of snails were 55.75%, 49.32%, 85.94% and 87.50%, and 55.00%, 48.47%, 85.70% and 87.29% in groups A, B, C and D 14 days post-treatment. There was a significant difference in the mortality of snails among the four groups 14 days post-treatment (χ2 = 38.735, P < 0.005), and there was a higher snail mortality in Group D than in Group A (χ2 = 16.876, P < 0.005), and higher in Group C than in Group B (χ2 = 20.508, P < 0.005). The density of living snails reduced by 55.00%, 43.94%, 90.43% and 87.14% 14 days post-treatment relative to pre-treatment in groups A, B, C and D, respectively. The test for uniformity of chemicals showed that the mean dose of molluscicides were 57.34, 55.21, 40.19 g/m2 and 32.37 g/m2 in groups A, B, C and D, respectively, and the minimal standard deviation (7.07) and coefficient of variation (0.18) of mean doses were seen in Group C. The costs for chemical treatment were 0.33 Yuan in groups A and B and 1.53 Yuan in groups C and D, respectively. The costs for a 1% reduction in the mean density of living snails were 17.82, 22.47, 50.73 Yuan and 52.56 Yuan in groups A, B, C, and D 14 days post-treatment, respectively. Conclusions The molluscicidal effect and cost of spraying 5% niclosamide ethanolamine salt granules with drones are comparable to manual spraying, and chemical treatment with drones are high in uniformity of molluscicides, time- and labor-saving, and feasible for applications in complex environments, which deserves widespread applications in the field of snail control.
10.Bioequivalence study of pitavastatin calcium dispersible tablets in healthy Chinese volunteers
Wei ZHANG ; Chun-Miao PAN ; Xiao-Dan WANG ; Yin HU ; Rong SHAO ; Bo JIANG
The Chinese Journal of Clinical Pharmacology 2024;40(10):1497-1501
Objective To compare the bioavailability and bioequivalence of pivastatin calcium dispersive tablets in healthy Chinese subjects.Methods A single dose of pitavastatin calcium(2 mg)was orally administered to the test preparation or reference preparation under fasting and postprandial conditions,respectively.The plasma concentrations of pitavastatin calcium were measured at different time points before and after administration by high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS).The bioequivalence of the two formulations was evaluated.Results Subjects received pitavastatin calcium test preparation and reference preparation in fasting condition,the Cmax were(47.79±23.99)and(46.03±21.82)ng·L-1;AUC0_,were(96.56±42.64)and(97.96±35.40)ng·h·L-1;AUC0_∞ were(102.09±43.01)and(103.46±35.62)ng·h·L-1,respectively.The 90%confidence intervals of the geometric mean ratios of Cmax,AUC0_t and AUC0-∞ of pitavastin-calcium test formulation and reference formulation were 96.28%-111.16%,94.46%-101.19%and 94.77%-101.31%,respectively.Subjects received pitavastatin calcium test preparation and reference preparation in fasting condition,the Cmax were(27.32±10.68)and(28.58±11.39)ng·L-1;AUC0_t were(82.76±27.58)and(84.06±29.12)ng·h·L-1;AUC0_∞ were(87.88±26.93)and(89.29±29.18)ng·h·L-1,respectively.The 90%confidence intervals of the geometric mean ratios of Cmax,AUC0_t and AUC0_∞ of the test formulation and the reference formulation of pitavastatin calcium were 87.39%-102.10%,94.62%-101.34%and 94.88%-101.47%,respectively.All of them were within the bioequivalence range of 80.00%to 125.00%.Conclusion Two pivastatin calcium dispersion tablets were bioequivalent and safe in healthy Chinese adult subjects.

Result Analysis
Print
Save
E-mail