1.Predicting the Risk of Arterial Stiffness in Coal Miners Based on Different Machine Learning Models.
Qian Wei CHEN ; Xue Zan HUANG ; Yu DING ; Feng Ren ZHU ; Jia WANG ; Yuan Jie ZOU ; Yuan Zhen DU ; Ya Jun ZHANG ; Zi Wen HUI ; Feng Lin ZHU ; Min MU
Biomedical and Environmental Sciences 2024;37(1):108-111
2.Separation and Enrichment of β-Agonists from Animal Livers Based on Magnetic Solid-Phase Extraction with Automated-treatment Device
Shu-Lin WEI ; Zi-Hao WANG ; Tong LI ; Huai-En ZHU ; Ji-Hao SHAN ; Zhi-Chao SONG ; Rui-Guo WANG
Chinese Journal of Analytical Chemistry 2024;52(2):277-285
A liquid chromatography-tandem mass spectrometry(LC-MS/MS)method was developed for determination of three kinds of β-agonists(Clenbuterol(CL),Ractopamine(RAC)and Salbutamol(SAL))residues in animal liver samples.The liver sample homogenates were extracted with organic solvent,followed by clean-up using the automatic magnetic solid-phase extraction(MSPE),and then analyzed using LC-MS/MS.The results showed that the magnetic mixed-mode cation exchange adsorbent(M-MCX)exhibited 34%higher adsorption capacity than the conventional mixed-mode cation exchange(MCX)column.Furthermore,the clean-up was conducted by using an automatic MSPE device,and 8 samples could be simultaneously treated within 30 min.The limits of detection(LOD)were 0.01-0.1 μg/kg,the average recoveries ranged from 88.2%to 110.5%,and the relative standard deviations(RSDs)were in range of 2.9%-10.3%at three spiked levels for the three kinds of β-agonists.Compared with the traditional SPE technique,the present method had many advantages such as simple operation,rapidity and high efficiency,which was suitable for high-throughput and automatic detection of residues in routine analysis.
3.Outcome analysis of functional mitral regurgitation after transcatheter aortic valve replacement in patients with severe bicuspid aortic stenosis
Da-Wei LIN ; Zi-Long WENG ; Feng ZHANG ; Wen-Zhi PAN ; Da-Xin ZHOU
Fudan University Journal of Medical Sciences 2024;51(1):34-40
Objective To explore the relationship between the types of bicuspid aortic valves(BAV)and the outcome of functional mitral regurgitation(FMR)and the affecting factors of FMR.Methods From Jun 2018 to Sep 2022,patients with severe BAV aortic valve stenosis(AS)complicated with FMR underwent post transcatheter aortic valve replacement(TAVR)in Zhongshan Hospital,Fudan University were retrospectively analyzed.The baseline information and imaging data of different BAV patients were collected.Logistic regression was used to analyze the factors affecting the outcome of FMR(improvement and non-improvement).Result A total of 100 patients with TAVR were included,including 49 patients with type 0 of BAV and 51 patients with type 1 of BAV.Compared with patients of type 1,patients of type 0 had younger age[(72.78±6.09)y vs.(77.00±8.35)y,P=0.050],lower male ratio(47%vs.73%,P= 0.009)higher BMI[(23.19±2.62)kg/m2 vs.(21.99±3.13)kg/m2,P=0.041],and lower incidence of aortic regurgitation(69%vs.92%,P=0.040).Compared with the non-improvement group,the improvement group had a lower incidence of coronary heart disease(5%vs.18%,P=0.042),higher incidence of pulmonary hypertension(20%vs.2%,P=0.007),larger left ventricular diastolic diameter[(51.98±6.74)mm vs.(48.04±7.72)mm,P=0.009]and higher maximum flow velocity[(4.86±0.95)cm/s vs.(4.47±0.75)cm/s,P= 0.023]of the aortic valve.The results of Logistic regression analysis showed that preoperative pulmonary hypertension,left ventricular end-diastolic diameter and maximum valvular flow velocity of BAV patients were the potential affecting factors of FMR improvement after TAVR.Conclusion No significant difference was found in FMR improvement between BAV patients of type 0 and type 1 after TAVR.For BAV patients with AS,preoperative pulmonary hypertension,larger left ventricular end-diastolic diameter,and faster aortic valve flow velocity were associated with higher FMR improvement rate.
4.Superior vena cava syndrome and pulmonary artery stenosis in a patient with lung metastases of bladder cancer
Jian-Ke LI ; Ya-Nan GU ; Jun-Hao LI ; Liang-Wen WANG ; Ning-Zi TIAN ; Wei CHEN ; Xiao-Lin WANG ; Yi CHEN
Fudan University Journal of Medical Sciences 2024;51(2):277-279,284
Superior vena cava syndrome(SVCS)is a group of clinical syndromes caused by obstruction of the superior vena cava and its major branches from various causes.Pulmonary artery stenosis(PS)is a complication of lung cancer or mediastinal tumours.SVCS combined with PS due to pulmonary metastases from bladder cancer is extremely rare and has not been reported in the literature.Here we reported an old male patient with pulmonary metastases from bladder cancer presenting with swelling of the head,neck and both upper limbs.SVCS combined with PS was clarified by pulmonary artery computed tomography angiography(CTA)and digital subtraction angiography(DSA).Endovascular stenting was used to treat SVCS.Angiography also showed that PS had not caused pulmonary hypertension and did not need to be treated.The swelling of the patient's head,neck and upper limbs was gradually reduced after the procedure.
5.Identification of TEAD1 Transcripts and Functional Analysis in Chicken Preadipocytes
Min PENG ; Hu XU ; Zi-Qiu JIA ; Qing-Zhu YANG ; Lin PAN ; Wei-Yu WANG ; Ling-Zhe KONG ; Ying-Ning SUN
Progress in Biochemistry and Biophysics 2024;51(1):215-229
ObjectiveAlthough expression of the TEAD1 protein in preadipocytes has been established, its function remains unclear. In this study, we sought to detect transcripts of TEAD1 in chicken and to examine the effects of this protein on the proliferation, migration, apoptosis, and differentiation of immortalized chicken preadipocyte cell lines (ICP1). MethodsThe full-length sequence of the TEAD1 gene was cloned and the two transcripts were subjected to bioinformatics analysis. The subcellsular localization of TEAD1 transcripts was determined based on indirect immunofluorescence. The effects of TEAD1 transcripts overexpression on the proliferation of ICP1 cells were examined by RT-qPCR, CCK-8, and EdU assays; the effects of TEAD1 transcripts on ICP1 cells migration were examined based on the scratch test; and the effects of TEAD1 transcripts overexpression on ICP1 cells apoptosis were analyzed using apoptosis-Hoechst staining and RT-qPCR. The expression of TEAD1 transcripts in different tissues, cells lines, and ICP1 at different periods of differentiation was analyzed by RT-qPCR. The effects of TEAD1 transcripts overexpression on lipid droplet accumulation and adipogenic-related gene expression in ICP1 cells were analyzed based on Oil Red O and BODIPY staining, RT-qPCR, Western blot, and dual-luciferase reporter gene assays. Finally, the content of triglyceride (TG) was measured in TEAD1 overexpressed ICP1 cells. ResultsThe full-length TEAD1 was cloned and two TEAD1 transcripts were identified. The TEAD1-V1 protein was found to be localized primarily in the cell nucleus, whereas the TEAD1-V2 protein is localized in the cell cytoplasm and nucleus. The overexpression of both TEAD1-V1 and TEAD1-V2 significantly inhibited the proliferation of ICP1 cells. Whereas the overexpression of TEAD1-V1 promoted ICP1 cell migration, the overexpression of TEAD1-V2 had no significant effects on ICP1 migration; the overexpression of both TEAD1-V1 and TEAD1-V2 significantly promoted the apoptosis of ICP1 cells. We found that the different transcripts of TEAD1 have similar expression pattern in different tissues and cells lines. During induced preadipocyte differentiation, the expression of these genes initially declined, although subsequently increased. Overexpression of TEAD1-V1 promoted a significant reduction in lipid droplet formation and inhibited C/EBPα expression during the differentiation of ICP1 cells (P<0.05). However, the overexpression of TEAD1-V2 had no significant effect on lipid droplet accumulation or the expression of adipogenic-related proteins (P>0.05). Overexpression of TEAD1-V1 significantly decreased triglyceride content in ICP1 cells (P<0.05), while overexpression of TEAD1-V2 had no effect on triglyceride content in ICP1 cells (P>0.05). ConclusionIn this study, for the first time, identified two TEAD1 transcripts. Overexpressed transcripts TEAD1-V1 and TEAD1-V2 both inhibited the proliferation of chicken preadipocytes and promoted apoptosis of chicken preadipocytes. TEAD1-V1 inhibited the differentiation of preadipocytes and promoted the migration of preadipocytes, while TEAD1-V2 had no effect on the differentiation and migration of preadipocytes.
6.Influencing factors in scale-up of extraction process for Yunpi Xiaoshi Prescription
Xin-Rong LIN ; Zi-Wei GAO ; Ya-Chun SHU ; Xia ZHAO ; Lei WU
Chinese Traditional Patent Medicine 2024;46(2):391-396
AIM To investigate the influencing factors in scale-up of extraction process for Yunpi Xiaoshi Prescription.METHODS HPLC was adopted in the content determination of catechin,ferulic acid,taxifolin,isovitexin,narirutin,atractylenolideⅡ,naringin,morin,hesperidin,luteolin,hederagenin,atractylenolideⅠ,naringenin and hesperetin,the fingerprints were established,after which the effects of container volume,optimal fire and feeding quantity on the contents of various constituents were evaluated.RESULTS Fifteen batches of samples demonstrated the similarities of more than 0.995.Fourteen constituents showed good linear relationships within their own ranges(r>0.999 0),whose average recoveries were 96.4%-103.3%with the RSDs of 0.5%-2.7%.The influencing degree of optimal fire was greater than that of container volume and feeding quantity.CONCLUSION The combination of multi-component content determination and fingerprints can provide data basis and theoretical reference for the technology of consistency evaluation in scale-up of extraction process for Yunpi Xiaoshi Prescription.
7.In vitro study on the sealing effect of different shapes of cuff tracheal tubes under the lowest safe pressure
Chunyuan ZHAO ; Ling HUANG ; Zi WEI ; Long CHANG ; Jing LIN ; Chunfeng ZHOU
Chinese Critical Care Medicine 2024;36(1):28-32
Objective:To compare the effectiveness of cylindrical-shaped and conical-shaped cuff catheters for airway closure using different pressure measurement methods at the lowest safe pressure and to guide the clinical application.Methods:Twenty-four patients with endotracheal intubation admitted to the intensive care unit (ICU) of Guangxi Medical University Cancer Hospital from December 2021 to January 2022 were enrolled. Leakage test in vitro was performed on the secretion on the patients' cuff. The needle and plunger from 20 mL syringe was separated, the syringe was sealed with adhesive, and the syringe nozzle was filled thoroughly to create a tracheal model. Consecutively, both cylindrical-shaped and conical-shaped cuff catheters were inserted into the simulated trachea, and the cuff pressure was calibrated to 20 cmH 2O (1 cmH 2O≈0.098 kPa) before commencing the experiment. The viscosity of the secretion on the patients' cuff was classified (grade Ⅰ was watery subglottic secretion, grade Ⅱ was thick subglottic secretion, grade Ⅲ was gel-like subglottic secretion), and the same viscosity secretion was injected into the catheter cuff. Utilizing a self-control approach, intermittent pressure measurement was initially conducted on both the cylindrical-shaped and conical-shaped cuff by improved pressure measurement method (intermittent pressure measurement group), followed by continuous pressure measurement experiment (continuous pressure measurement group). The leakage volume of the three viscosity subglottic secretions and the values of cuff pressure measurement of different shaped cuff catheters at 4, 6, 8 hours of inflation were recorded. Results:A total of 180 retention samples were extracted from 24 patients with tracheal intubation during ventilation, with 90 samples in each of the two groups using different pressure measurement methods, and 30 samples of retention materials with different viscosities in each group. In the intermittent pressure measurement group, at 4 hours of inflation, all samples of secretion with grade Ⅰ and grade Ⅱ on cylindrical-shaped cuff leaked, while 3 samples of secretion with grade Ⅲ also leaked. For conical-shaped cuff, 28 samples of secretion with grade Ⅰ leaked, only 2 samples of secretion with grade Ⅱ leaked, and there was no leak for secretion with grade Ⅲ. At 6 hours of inflation, all samples of the three viscosity secretions on different shaped cuffs leaked. The leakage was gradually increased with the prolongation of inflation time. In the continuous pressure measurement group, at 4 hours of inflation, all samples of secretion with grade Ⅰ on cylindrical-shaped cuff leaked, while 29 samples of secretion with grade Ⅱ leaked, and there was no leak for secretion with grade Ⅲ. For the conical-shaped cuff, 26 samples of secretion with grade Ⅰ leaked, and there was no leak for secretion with grade Ⅱ and grade Ⅲ. At 6 hours of inflation, the conical-shaped cuff still had no leak for secretion with grade Ⅲ. As the inflation time prolonged, the leakage of subglottic secretion on different shaped cuffs in both groups was gradually increased. At 8 hours of inflation, all samples experienced leakage, but the leakage of subglottic secretion on different shaped cuffs in the continuous pressure measurement group was significantly reduced as compared with the intermittent pressure measurement group [leakage for secretion with grade Ⅲ (mL): 1.00 (0.00, 1.25) vs. 2.00 (1.00, 2.00) on the cylindrical-shaped cuff, 1.00 (0.00, 1.00) vs. 2.00 (2.00, 2.00) on the conical-shaped cuff, both P < 0.01]. The values of pressure measurement of cuffs with different shapes at different time points of inflation in the continuous pressure measurement group were within the set range (20-21 cmH 2O). The cuff pressure at 4 hours of inflation in the intermittent pressure measurement group was significantly lower than the initial value (cmH 2O: 18.3±0.6 vs. 20.0±0.0 in the cylindrical-shaped cuff, 18.4±0.6 vs. 20.0±0.0 in the conical-shaped cuff, both P < 0.01), and the cuff pressure in both shaped cuffs showed a significant decrease tendency as inflation time prolonged. However, there was no statistically significant difference in values of pressure measurement between the different shaped cuff catheters. Conclusions:Continuous pressure monitoring devices can maintain the effective sealing of conical-shaped cuff catheters at the lowest safe pressure. When using an improved pressure measurement method for intermittent pressure measurement and/or using a cylindrical cuff catheter, the target pressure should be set at 25-30 cmH 2O, and the cuff pressure should be adjusted regularly.
8.Research progress on the role of miRNA in drug resistance of pleural mesothelioma
Xinmeng WANG ; Jinsong LI ; Yaru LIN ; Ximin TANG ; Yuanqian PU ; Jiaji ZI ; Wei XIONG
China Pharmacy 2024;35(22):2832-2836
Pleural mesothelioma (PM) is a rare malignant tumor originating from the pleura. Most patients are already in the advanced stage at the time of diagnosis, resulting in a low overall survival rate. MicroRNA (miRNA), as key regulators of tumor epigenetic modification, have an intertwined interactive network with PM drug resistance. The mechanisms of drug resistance in PM to chemotherapeutic drugs include increasing drug efflux, reducing drug intake, enhancing DNA repair, and altering drug targets. The mechanisms of resistance to targeted therapy drugs include activating alternative signaling pathways, establishing a favorable tumor microenvironment, and triggering epithelial-mesenchymal transition. MiRNA plays a key part in the aforementioned resistance mechanisms, with some miRNAs promoting the drug sensitivity of cancer cells, while others contribute to increased drug resistance. In light of these key regulatory functions, targeting the dysregulated expression of endogenous miRNAs in the process of resistance formation using miRNA antagonists or miRNA mimics may be an effective therapeutic strategy to reverse drug resistance in PM.
9.Design,numerical simulation and experimental study of novel oxygenator
Ming-Hao YUE ; Shi-Yao ZHANG ; Ji-Nian LI ; Hui-Chao LIU ; Zi-Hua SU ; Ya-Wei WANG ; Zeng-Sheng CHEN ; Shi-Hang LIN ; Jin-Yu LI ; Ya-Ke CHENG ; Yong-Fei HU ; Cun-Ding JIA ; Ming-Zhou XU
Chinese Medical Equipment Journal 2024;45(3):23-28
Objective To design a novel oxygenator to solve the existing problems of extracorporeal membrane oxygenation(ECMO)machine in high transmembrane pressure difference,low efficiency of blood oxygen exchange and susceptibility to thrombosis.Methods The main body of the oxygenator vascular access flow field was gifted with a flat cylindrical shape.The topology of the vascular access was modeled in three dimensions,and the whole flow field was cut into a blood inlet section,an inlet buffer,a heat exchange zone,a blood oxygen exchange zone,an outlet buffer and a blood outlet section.The oxygenator was compared with Quadrox oxygenator by means of ANSYS FLUENT-based simulation and prototype experiments.Results Simulation calculations showed the oxygenator designed was comparable to the clinically used ones in general,and gained advantages in transmembrane pressure difference,blood oxygen exchange and flow uniformity.Experimental results indicated that the oxygenator behaved better than Quadrox oxygenator in transmembrane pressure difference and blood oxygen exchange.Conclusion The oxygenator has advantages in transmem-brane pressure difference,temperature change,blood oxygen ex-change and low probability of thrombosis.[Chinese Medical Equipment Journal,2024,45(3):23-28]
10.Study on Self-reaction of n-Pentyl Peroxy Radical by Vacuum Ultraviolet Photoionization Mass Spectrometry
Ling-Yu LIU ; Zi-Ji MA ; Yu XIA ; Xiao-Xiao LIN ; Wei-Jun ZHANG
Chinese Journal of Analytical Chemistry 2024;52(6):856-865
The n-pentyl peroxy radical (C5H11O2) is a crucial intermediate in the oxidation process of n-pentane,playing an important role in the chain propagation and termination of atmospheric radicals under low NOx conditions. The products from the self-reaction of C5H11O2 were detected online by a microwave discharge fast-flow reactor combined with a vacuum ultraviolet photoionization mass spectrometry in this work. The results indicated three product channels in the self-reaction of C5H11O2,corresponding to alkoxyl radicals (C5H11O),carbonyl compounds (C5H10O) and organic alcohol (C5H11OH),as well as dimeric products (C5H11OOC5H11). Further research was conducted to determine the original channels of the products through reaction kinetics experiments,revealing the self-reaction mechanism of C5H11O2 by comparing the experimental and the simulated results of the main products. The dimeric product C5H11OOC5H11,formed in the self-reaction of C5H11O2,was measured online for the first time,predicting its channel branching ratio to be approximately 10%. The molecular and ionic structures of the product were determined with the help of quantum chemical theoretical calculations.

Result Analysis
Print
Save
E-mail