1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Expert consensus on cryoablation therapy of oral mucosal melanoma
Guoxin REN ; Moyi SUN ; Zhangui TANG ; Longjiang LI ; Jian MENG ; Zhijun SUN ; Shaoyan LIU ; Yue HE ; Wei SHANG ; Gang LI ; Jie ZHNAG ; Heming WU ; Yi LI ; Shaohui HUANG ; Shizhou ZHANG ; Zhongcheng GONG ; Jun WANG ; Anxun WANG ; Zhiyong LI ; Zhiquan HUNAG ; Tong SU ; Jichen LI ; Kai YANG ; Weizhong LI ; Weihong XIE ; Qing XI ; Ke ZHAO ; Yunze XUAN ; Li HUANG ; Chuanzheng SUN ; Bing HAN ; Yanping CHEN ; Wenge CHEN ; Yunteng WU ; Dongliang WEI ; Wei GUO
Journal of Practical Stomatology 2024;40(2):149-155
Cryoablation therapy with explicit anti-tumor mechanisms and histopathological manifestations has a long history.A large number of clinical practice has shown that cryoablation therapy is safe and effective,making it an ideal tumor treatment method in theory.Previously,its efficacy and clinical application were constrained by the limitations of refrigerants and refrigeration equipment.With the development of the new generation of cryoablation equipment represented by argon helium knives,significant progress has been made in refrigeration efficien-cy,ablation range,and precise temperature measurement,greatly promoting the progression of tumor cryoablation technology.This consensus systematically summarizes the mechanism of cryoablation technology,indications for oral mucosal melanoma(OMM)cryotherapy,clinical treatment process,adverse reactions and management,cryotherapy combination therapy,etc.,aiming to provide reference for carrying out the standardized cryoablation therapy of OMM.
6.Analysis of surgical complications after laparoscopic duodenum-preserving pancreatic head resection for noncancerous lesions
Wei CHAI ; Zhiquan ZHANG ; Bao LEI ; Junjian YUAN ; Yu MENG ; Xiulei ZHAO ; Lei ZHANG ; Ruhai LIU
Chinese Journal of General Surgery 2022;37(6):443-446
Objective:To analyze the common complications of laparoscopic duodenum- preserving pancreatic head resection(LDPPHR).Methods:The clinical data of 32 patients undergoing LDPPHR from Jun 2018 to Jun 2021 in Cangzhou Central Hospital were analyzed retrospectively.Results:LDPPHR was successfully performed in all 32 patients without conversion to open surgery. The incidence of postoperative complications was 21.9% (7/32), 3 cases suffering from sever complications (1 case of long-term postoperative pancreatic fistula, 1 case of obstructive jaundice caused by duodenal papilla stenosis, 1 case of postoperative abdominal bleeding) were cured by laparotomy; 4 cases of minor complications were simple pancreatic fistula, which were cured by prolonging dranage.Conclusions:LDPPHR is technically feasible for isolated noncancerous lesions within pancreatic head and uncinate process,the complications were manageable.Its suggested benefits remain to be established by long term follow-up.
7.Defining Proximity Proteome of Histone Modifications by Antibody-mediated Protein A-APEX2 Labeling
Li XINRAN ; Zhou JIAQI ; Zhao WENJUAN ; Wen QING ; Wang WEIJIE ; Peng HUIPAI ; Gao YUAN ; J.Bouchonville KELLY ; M.Offer STEVEN ; Chan KUIMING ; Wang ZHIQUAN ; Li NAN ; Gan HAIYUN
Genomics, Proteomics & Bioinformatics 2022;20(1):87-100
Proximity labeling catalyzed by promiscuous enzymes,such as APEX2,has emerged as a powerful approach to characterize multiprotein complexes and protein-protein interactions.How-ever,current methods depend on the expression of exogenous fusion proteins and cannot be applied to identify proteins surrounding post-translationally modified proteins.To address this limitation,we developed a new method to label proximal proteins of interest by antibody-mediated protein A-ascorbate peroxidase 2(pA-APEX2)labeling(AMAPEX).In this method,a modified protein is bound in situ by a specific antibody,which then tethers a pA-APEX2 fusion protein.Activation of APEX2 labels the nearby proteins with biotin;the biotinylated proteins are then purified using streptavidin beads and identified by mass spectrometry.We demonstrated the utility of this approach by profiling the proximal proteins of histone modifications including H3K27me3,H3K9me3,H3K4me3,H4K5ac,and H4K12ac,as well as verifying the co-localization of these iden-tified proteins with bait proteins by published ChIP-seq analysis and nucleosome immunoprecipi-tation.Overall,AMAPEX is an efficient method to identify proteins that are proximal to modified histones.
8.Application of holographic image navigation in urological laparoscopic and robotic surgery
Gang ZHU ; Jinchun XING ; Guobin WENG ; Zhiquan HU ; Ningchen LI ; He ZHU ; Pingsheng GAO ; Zhihua WANG ; Weizhi ZHU ; Kai ZHANG ; Hongbo LI ; Zhun WU ; Rui ZHU ; Xifeng WEI ; Yanan WANG ; Qun XIE ; Bing FU ; Xinghuan WANG ; Lin QI ; Xin YAO ; Tiejun PAN ; Delin WANG ; Nan LIU ; Jianguang QIU ; Jianggen YANG ; Bao ZHANG ; Zhuowei LIU ; Hui HAN ; Gang LI ; Bin ZHANG ; Manli NA ; Jingjing LU ; Lei WANG ; Zichen ZHAO ; Yanqun NA
Chinese Journal of Urology 2020;41(2):131-137
Objective To evaluate the clinical value of holographic image navigation in urological laparoscopic and robotic surgery.Methods The data of patients were reviewed retrospectively for whom accepted holographic image navigation laparoscopic and robotic surgery from Jan.2019 to Dec.2019 in Beijing United Family Hospital and other 18 medical centers,including 78 cases of renal tumor,2 cases of bladder cancer,2 cases of adrenal gland tumor,1 cases of renal cyst,1 case of prostate cancer,1 case of sweat gland carcinoma with lymph node metastasis,1 case of pelvic metastasis after radical cystectomy.All the patients underwent operations.In the laparoscopic surgery group,there were 27 cases of partial nephrectomy,1 case of radical prostatectomy,2 cases of radical cystectomy and 2 cases of adrenalectomy.In the da Vinci robotic surgery group of 54 cases,there were 51 cases of partial nephrectomy,1 case of retroperitoneal lymph node dissection,1 case of retroperitoneal bilateral renal cyst deroofing and 1 case of resection of pelvic metastasis.There were 41 partial nephrectomy patients with available clinical data for statistic,with a median age of 53.5 years (range 24-76),including 26 males and 15 females.The median R.E.N.A.L score was 7.8 (range 4-11).Before the operation,the engineers established the holographic image based on the contrast CT images and reports.The surgeon applied the holographic image for preoperative planning.During the operation,the navigation was achieved by real time fusing holographic images with the laparoscopic surgery images in the screen.Results All the procedures had been complete uneventfully.The holographic images helped surgeon in understanding the visual three-dimension structure and relation of vessels supplying tumor or resection tissue,lymph nodes and nerves.By manipulating the holographic images extracorporeally,the fused image guide surgeons about location vessel,lymph node and other important structure and then facilitate the delicate dissection.For the 41 cases with available clinical data including 23 cases of robotic-assisted partial nephrectomy and 18 cases of laparoscopic nephrectomy,the median operation time was 140 (range 50-225) min,the median warm ischemia time was 23 (range 14-60) min,the median blood loss was 80(range 5-1 200) ml.In the robotic surgery group,the median operation time was 140 (range 50-215)min,the median warm i schemia time was 21 (range 17-40)min,the median blood loss was 150(range 30-1 200)ml.In the laparoscopic surgery group,the median operation time was 160(range 80-225)min,the median warm ischemia time was 25 (range 14-60)min,the median blood loss was 50 (range 5-1 200) ml.All the patients had no adjacent organ injury during operation.There were 2 cases with Clavien Ⅱ complications.One required transfusion and the other one suffered hematoma post-operation.However,the tumors were located in the renal hilus for these 2 cases and the R.E.N.A.L scores were both 11.Conclusions Holographic image navigation can help location and recognize important anatomic structures during the surgical procedures..This technique will reduce the tissue injury,decrease the complications and improve the success rate of surgery.
9.A case matched study on laparoscopic versus open radical resection for Bismuth-type Ⅲb hilar cholangiocarcinoma
Wei CHAI ; Zhiquan ZHANG ; Bao LEI ; Yu MENG ; Xiulei ZHAO ; Lei ZHANG ; Ruhai LIU
Chinese Journal of General Surgery 2019;34(5):377-380
Objective To explore the safety and feasibility of laparoscopic radical resection of Bismuth-type Ⅲb hilar cholangiocarcinoma.Methods The clinical data of 109 patients with Bismuth-type Ⅲ b hilar cholangiocarcinoma in the Department of General Surgery of Cangzhou Central Hospital from Jan 2015 to Feb 2018 were retrospectively analyzed.Among those 17 patients undergoing total laparoscopic surgery were compared with 17 open cases.Results There were significant differences between the laparoscopic group and the control group in operation time [(420.8 ± 136.5) min vs (292.3 ± 65.6) min],total length of incision [(8.2 ± 4.7) cm vs (20.4 ± 5.8) cm],incidence of postoperative complications [29.4% (5/17) vs 52.9% (9/17)],postoperative feeding time,postoperative ICU stay and postoperative hospital stay (P < 0.05).There were no significant difference in the amount of bleeding[(325.2 ± 98.7)ml vs(367.4 ±72.9)ml],pathological results,number of lymph node dissection,R0 resection rate and tumor recurrence rate (P > 0.05).Conclusion Total laparoscopic radical resection of Bismuth-type Ⅲ b hilar cholangiocarcinoma is safe,feasible,and has the advantages of minimal invasion and rapid recovery.
10.In vitro EdU labeling of peripheral blood mononuclear cells in rabbits
Minglei ZHAO ; Dongqin ZHEN ; Jianfa HUANG ; Weihua LI ; Wencong WANG ; Zhiquan LI ; Hening ZHANG ; Bikun XIAN ; Yuting PENG ; Minyi ZHOU ; Bing HUANG
Chinese Journal of Tissue Engineering Research 2017;21(9):1432-1438
BACKGROUND: The proliferation of peripheral blood stem cells among peripheral blood mononuclear cells (PBMCs) invitro remains unclear. There is no optimal marker for tracing PBMCs transplanted in vivo.OBJECTIVE: To observe the degree of PBMC proliferation in stem cell medium by EdU labeling and to explore thefeasibility of EdU-labeled peripheral blood stem cells.METHODS: New Zealand rabbit PBMCs were isolated and cultured for 1 to 5 days in stem cell medium supplementedwith EdU. The cells were observed and counted at 0, 1, 2, 3, 4 and 5 days in culture. The cells were harvested at eachtime point and stained with EdU fluorescent reagents. Then, confocal microscopy and flow cytometry were used to detectEdU-labeled cells.RESULTS AND CONCLUSION: (1) Freshly isolated rabbit PBMCs were rounded and showed clear outline. After 1 dayculture, most of the cells were suspended in the medium, spherical or round. There were also a few cell clusters andadherent cells scattered in a triangle or polygon shape; after 2 days culture, more cell debris were observed, and mostcells were round; when cultured for 3-5 days, increased cell debris, smaller cell mass and decreased cell densitysignificantly were observed. (2) With the prolongation of culture time, the cell count decreased gradually. (3) Whencultured for 1 day, EdU labeled cells in red were scattered. The number of cells marked with EdU red label increasedsignificantly at day 2 and remained unchanged after 3 days of culture. At 5 days of culture, the number of red cellsmarkedly decreased; the highest positive rate of EdU-labeled cells was (2.38±0.10)% at 2 days after culture. To conclude,these results showed that the proportion of proliferating cells in rabbit PBMCs was very low. EdU is capable of labelingproliferative cells among PBMCs.

Result Analysis
Print
Save
E-mail