1.Expert consensus on cryoablation therapy of oral mucosal melanoma
Guoxin REN ; Moyi SUN ; Zhangui TANG ; Longjiang LI ; Jian MENG ; Zhijun SUN ; Shaoyan LIU ; Yue HE ; Wei SHANG ; Gang LI ; Jie ZHNAG ; Heming WU ; Yi LI ; Shaohui HUANG ; Shizhou ZHANG ; Zhongcheng GONG ; Jun WANG ; Anxun WANG ; Zhiyong LI ; Zhiquan HUNAG ; Tong SU ; Jichen LI ; Kai YANG ; Weizhong LI ; Weihong XIE ; Qing XI ; Ke ZHAO ; Yunze XUAN ; Li HUANG ; Chuanzheng SUN ; Bing HAN ; Yanping CHEN ; Wenge CHEN ; Yunteng WU ; Dongliang WEI ; Wei GUO
Journal of Practical Stomatology 2024;40(2):149-155
Cryoablation therapy with explicit anti-tumor mechanisms and histopathological manifestations has a long history.A large number of clinical practice has shown that cryoablation therapy is safe and effective,making it an ideal tumor treatment method in theory.Previously,its efficacy and clinical application were constrained by the limitations of refrigerants and refrigeration equipment.With the development of the new generation of cryoablation equipment represented by argon helium knives,significant progress has been made in refrigeration efficien-cy,ablation range,and precise temperature measurement,greatly promoting the progression of tumor cryoablation technology.This consensus systematically summarizes the mechanism of cryoablation technology,indications for oral mucosal melanoma(OMM)cryotherapy,clinical treatment process,adverse reactions and management,cryotherapy combination therapy,etc.,aiming to provide reference for carrying out the standardized cryoablation therapy of OMM.
2.FreeArcs Knife:a Novel Stereotactic Radiosurgery System
Zhiquan TANG ; Shaojin HUANG ; Renming ZHONG
Chinese Journal of Medical Instrumentation 2024;48(4):434-439
This paper describes the design of an innovative linear accelerator image-guided radiosurgery(IGRS)device,which is based on a composite twofold rotary gantry structure.The paper discusses five aspects of the innovative device:its overall composition,the safety net space created by the accelerator radiation head as it rotates around the patient's longitudinal axis,the non-coplanar spherical coverage in the direction of the incidence angle for quasi-4π delivery,the structural features of the composite twofold rotary gantry,and the processes of treatment planning and implementation.It elaborates on the device's manufacturing feasibility,safety,effectiveness,accuracy,and efficiency.The conclusion is that this innovative device design holds significant development value and market promotion potential.
3.Curative effect analysis of treating concealed penis based on the idea of flap transfer in the treatment of hypospadias
Yongchuan CAI ; Chaoyou HUANG ; Wei WANG ; Yunman TANG ; Yu LIU ; Zhiquan ZHU ; Xuejun WANG
Chinese Journal of Plastic Surgery 2023;39(6):614-620
Objective:To investigate the clinical effect of surgical treatment of concealed penis based on the idea of flap transfer in the treatment of hypospadias.Methods:Retrospectively analyzed the clinical data of children with concealed penis admitted to the Urology Department of Chengdu Second People’s Hospital and Department of Pediatric Surgery at Children’s Medical Center of Sichuan Provincial People’s Hospital, from July 2017 to July 2021. The control group used the traditional surgical method and the experimental group used a modified surgical approach based on the idea of flap transfer in the treatment of hypospadias. Short-term complications such as flap ischemia, edema, and skin dehiscence were statistically analyzed in the two groups, as well as the Boemers rating of penile appearance (good, general, poor), Vancouver scar scale (VSS) (mild, moderate, severe), overall penis shape (tower, cylindrical, inverted tower) at 6 months after surgery. Count data were analyzed using the Chi-square test.Results:298 children, aged 2.5 to 13.7 years, with a mean age of 6.4 years, were enrolled in the study. 103 children were in the control group, and 195 children were in the experimental group. All enrolled patients were operated successfully in the first stage and were discharged 3-4 days after the operation, with an average recovery time of 3-4 weeks. After a follow-up of more than 6 months, in the control group, 2 cases (1.9%) of flap ischemia and 3 cases (2.9%) of skin dehiscence occurred after surgery. Two children (1.0%) in the experimental group had skin dehiscence after surgery, and the difference in the recent complication rate between the two groups was not significant [4.9%(5/103) vs. 1.0%(2/195), P>0.05]. The proportion of Boemers rated"good"in the experimental group was higher than that in the control group [93.3% (182/195) vs. 71.8% (74/103), P<0.01]. The proportion of moderate to severe scarring assessed by VSS was lower in the experimental group than in the control group [6.2% (12/195) vs. 26.2% (27/103), P<0.01]. The proportion of the overall penis shape of the penis close to the cylindrical shape of the normal penis in the experimental group was significantly higher than that in the control group [81.5% (159/195) vs. 60.2% (62/103), P<0.01]. Conclusion:Compared with the traditional surgical method, the modified surgical approach based on the idea of flap transfer in the treatment of hypospadias attaches more importance to the overall planning of the flap and the tension distribution of the fascial layer, which can be more effective to solve the problem of insufficient coverage of the concealed penile skin and reduce postoperative scar formation. Moreover, the appearance of the external genitalia is natural and closer to normal, the surgical effect is exact, and the long-term postoperative complications are lower.
4.Curative effect analysis of treating concealed penis based on the idea of flap transfer in the treatment of hypospadias
Yongchuan CAI ; Chaoyou HUANG ; Wei WANG ; Yunman TANG ; Yu LIU ; Zhiquan ZHU ; Xuejun WANG
Chinese Journal of Plastic Surgery 2023;39(6):614-620
Objective:To investigate the clinical effect of surgical treatment of concealed penis based on the idea of flap transfer in the treatment of hypospadias.Methods:Retrospectively analyzed the clinical data of children with concealed penis admitted to the Urology Department of Chengdu Second People’s Hospital and Department of Pediatric Surgery at Children’s Medical Center of Sichuan Provincial People’s Hospital, from July 2017 to July 2021. The control group used the traditional surgical method and the experimental group used a modified surgical approach based on the idea of flap transfer in the treatment of hypospadias. Short-term complications such as flap ischemia, edema, and skin dehiscence were statistically analyzed in the two groups, as well as the Boemers rating of penile appearance (good, general, poor), Vancouver scar scale (VSS) (mild, moderate, severe), overall penis shape (tower, cylindrical, inverted tower) at 6 months after surgery. Count data were analyzed using the Chi-square test.Results:298 children, aged 2.5 to 13.7 years, with a mean age of 6.4 years, were enrolled in the study. 103 children were in the control group, and 195 children were in the experimental group. All enrolled patients were operated successfully in the first stage and were discharged 3-4 days after the operation, with an average recovery time of 3-4 weeks. After a follow-up of more than 6 months, in the control group, 2 cases (1.9%) of flap ischemia and 3 cases (2.9%) of skin dehiscence occurred after surgery. Two children (1.0%) in the experimental group had skin dehiscence after surgery, and the difference in the recent complication rate between the two groups was not significant [4.9%(5/103) vs. 1.0%(2/195), P>0.05]. The proportion of Boemers rated"good"in the experimental group was higher than that in the control group [93.3% (182/195) vs. 71.8% (74/103), P<0.01]. The proportion of moderate to severe scarring assessed by VSS was lower in the experimental group than in the control group [6.2% (12/195) vs. 26.2% (27/103), P<0.01]. The proportion of the overall penis shape of the penis close to the cylindrical shape of the normal penis in the experimental group was significantly higher than that in the control group [81.5% (159/195) vs. 60.2% (62/103), P<0.01]. Conclusion:Compared with the traditional surgical method, the modified surgical approach based on the idea of flap transfer in the treatment of hypospadias attaches more importance to the overall planning of the flap and the tension distribution of the fascial layer, which can be more effective to solve the problem of insufficient coverage of the concealed penile skin and reduce postoperative scar formation. Moreover, the appearance of the external genitalia is natural and closer to normal, the surgical effect is exact, and the long-term postoperative complications are lower.
5.Effect of plastic and aesthetic surgery on complex facial injuries in children
Zhiquan GAO ; Jun SHI ; Haiyang SUN ; Xinyu WANG ; Dongsheng TANG ; Jun SHEN ; Ping YAO
Chinese Journal of Medical Aesthetics and Cosmetology 2022;28(4):312-315
Objective:To analyze the anatomical distribution of complex facial injuries (woun-ds ≥8 cm in length and involving two or more anatomical areas) in children, and to explore the effect of plastic and aesthetic surgery.Methods:A total of 157 children with complex facial injury were admitted to the Plastic Surgery Department of Hangzhou Plastic Surgery Hospital from January 2019 to June 2021, including 94 males and 63 females, aged from 2 to 18 years, with an average age of 6.2 years. The wound length was 8-20 cm, with an average length of 10.3 cm. Plastic surgery techniques were used to design different primary repair schemes according to specific wound conditions, and early postoperative scar prevention and treatment were carried out.Results:In 157 cases, 331 anatomical areas were involved, most of which were buccal (75 sites). The injury caused by sharp instruments (glass, ceramic tile, cutting tools, etc.) ranked the first place with 78 cases. All patients were followed up for more than 3 months, and the results showed 146 cases of primary healing, 11 cases of delayed healing, 8 cases of scar hyperplasia, 149 cases of good morphological and functional recovery.Conclusions:The advantages of using plastic and cosmetic surgery techniques to treat complex facial injuries lie in the emphasis on anatomical and functional reduction and tension-reducing suture, combined with a variety of postoperative scar prevention and treatment measures, and the results are satisfactory.
6.In-machine Fault Monitoring Mechanism and Maintainability Improvement of Varian Linear Accelerator.
Zhiquan TANG ; Ze JIANG ; Renyun LIU
Chinese Journal of Medical Instrumentation 2018;42(2):154-156
Through repaired the RF driver momentary oscillation stop of Varian 2300CD linear accelerator, systematically and comprehensively expounds the three state machine mode of control system and the in-machine fault monitoring mechanism involved in maintainability of Varian high energy accelerator. It proposes an improved solution to bring RF driver output into interlock system, by doing so it can avoid the control computer breakdown and improve maintainability.
Particle Accelerators
;
standards
7.Technological analysis and comparison for dose monitoring and control systems of two types of linear accelerators
China Medical Equipment 2017;14(5):27-33
Objective:To analyze and compare the dose monitoring and control systems of two types of medical linear accelerator systematically from the view of mechanical and electrical engineering, and establish the method of the quality assurance of the dosimetry system and the solution in the routine maintenance.Methods: To systematically compare and analyze the system of dose monitoring and control for two types of linear accelerators (Precise Elekta and C-series of Varian Medical Systems) from twofold aspects that included machine physics and electric engineering of medical linear accelerators.Results:The monitoring system that took ionization chamber as center was established between connotation of machine physics and concrete realization of electromechanical engineering, and explained the difference and similarity between open type and sealed type of ionization chamber, and the theory that Precise series needn't be serviced by PFN.Conclusion: Based on the analysis of ionization chambers structure of medical linear accelerators on the principle of quality assurance system, proposed dosimetric testing and adjustment method, and provide reference for the establishment of quality assurance system and technical procedures of the maintenance engineering.
8.Process control of maintenance management for large medical equipment
China Medical Equipment 2017;14(9):30-36
Objective:To explore the process of maintenance management for large medical equipment, and the structure design and core connotation of the maintenance management software of them.Methods: Medical linear accelerator of Precise series of Elekta company was combined to achieve the objective. From the aim of designing normal operation rate to start, the failure mode and effects analysis (FMEA) was operated to analyze the maintenance strategies and maintenance manners which were established on the basis of PDCA(Plan, Do, Check, Action) cycle and the analysis mode of SWOT (Strength, Weakness, Opportunity, Threat), and it could achieve the aim of normal operation rate.Results: Through explored the connotation of maintenance management and the preliminary framework of the software of maintenance management, the detail and process of maintenance management that based on personalized accelerator of process control were established, and the element factors of software of maintenance management of accelerator also was established at the same time.Conclusion: The effective maintenance management of large medical equipment is based on informatization process management of process control, and the element factor of management software need personalized customization. On the other hand, failure mode and degradation mechanism of equipment were the basis for personalized customization, and the creation has practical value.
9.Dose Monitoring and Maintain of Varian High Energy Linear Accelerators
Chinese Journal of Medical Instrumentation 2017;41(4):309-312
The paper analyzes the dose monitoring and control system of Varian C-series high energy linear accelerators systematically from twofold view of machine physics and electromechanical structure. It dissects the structure characteristics of chamber and implementation method of beam steering. It expounds the complete methods of quality control adjustment and troubleshooting.
10.Expression profiles of genes in wild-type DJ-1 and A39S DJ-1 mutant cells
Zhenhua LIU ; Beisha TANG ; Dan HE ; Lei WANG ; Zhiquan XIAO ; Xinxiang YAN ; Jifeng GUO
Journal of Central South University(Medical Sciences) 2014;(4):325-332
Objective: To elucidate the role of A39S mutation of DJ-1 in the onset of Parkinson’s disease (PD) and identify genes for which expressions are abnormally regulated by A39S DJ-1 mutation. Methods: We established HEK293 cell lines which stably expressed empty vector, wild-type DJ-1 and A39S mutated DJ-1 respectively. DNA microarrays were used to identify genes for which expressions change in wild-type DJ-1 cells and A39S DJ-1 mutant cells. Results: Compared with the cell line expression empty vector, we identified 42 differentially regulated genes (including 14 up-regulated genes and 28 down-regulated genes) in the wild-type DJ-1 cells and 8 differentially regulated genes (including 6 up-regulated genes and 2 down-regulated genes) in the A39S DJ-1 mutant cells. Compared with the wild-type DJ-1 cells, only the expression of UGT2B7 gene was down-regulated in A39S DJ-1 mutant cells. hTese differentially regulated genes were mainly related to signal transduction, regulation of transcription, apoptosis and metabolism. Conclusion: A39S mutated DJ-1 may disturb the transcriptional activities of DJ-l and involve in the pathogenesis of PD.

Result Analysis
Print
Save
E-mail