1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Interpretation of the World Health Organization global report on hypertension 2023
Qin SUN ; Weifan TIAN ; Tingting LUO ; Jing YU ; Dongze LI ; Haihong ZHANG ; Rui ZENG ; Zhi WAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):203-208
The World Health Organization (WHO) released the “Global report on hypertension” on September 19, 2023. This report systematically summarizes the prevalence, mortality, diagnosis and treatment of hypertension in various countries, and elucidates the current situation of hypertension management, and gives a series of suggestions on how to manage hypertension, providing new thinking and inspiration for countries to optimize hypertension management. Through the summary of relevant studies and reports, this paper further reviews the present situation, early identification and management of hypertension.
7.M1 polarization of macrophage induced by STING signaling promotes T cell immune response
Jianfei Li ; Zhi Duan ; Qian Liu ; Qiyin Zong ; Wanlu Duan ; Futing Liu ; Hao Zhang ; Qiang Zhou ; Qin Wang
Acta Universitatis Medicinalis Anhui 2024;59(11):1974-1981
Objective:
To investigate the effect of activation of the stimulator of interferon genes(STING) pathway on macrophage polarization function and its role in T-cell response.
Methods:
Mouse macrophage RAW264.7 cells were used.STING signaling related proteins in RAW264.7 macrophage treated with STING agonist diABZI were analyzed by Western blot,including TANK-binding kinase-1(TBK1),interferon regulatory factor-3(IRF3),STING,p-TBK1,p-IRF3,p-STING.The polarization of macrophage RAW264.7 cells treated with diABZI was analyzed by flow cytometry.Co-culture of diABZI-treated RAW264.7 macrophage and T cells was applied to evaluate the change of T cell response.
Results:
STING signaling related proteins were upregulated in macrophage RAW264.7 cells treated with diABZI for 3 hours.The expression of CD86 was upregulated on the surface of macrophages after 12 hours of diABZI treatment,and the CD86/CD206 ratio was elevated,which presented the M1 polarization phenotype.When coculturing diABZI-treated macrophage RAW264.7 cells with T cells,the cytokine secretion ability of T cells including CD4+T and CD8+T cells was enhanced and the expression of CD107a in CD8+T cells was upregulated.
Conclusion
STING signaling induces M1 polarization of macrophages which enhance the function of T cells,especially CD8+T cell immune response.
8.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.
9.Automatic monitoring of adverse drug reaction of anti-tuberculosis and analysis of influencing factors
Kai ZHANG ; Xiao-Qin LU ; Zhi DONG
The Chinese Journal of Clinical Pharmacology 2024;40(7):1059-1062
Objective To provide reference for clinical rational drug use,the adverse drug reaction(ADR)automatic monitoring system was used to monitor ADR in patients treated with first-line anti-tuberculosis drugs.Methods A total of 1 147 tuberculosis patients hospitalized in the infection department of our hospital from 2019 to 2022 were selected to monitor the occurrence of ADR during the hospitalization.Univariate and multivariate analysis were used to study the risk factors affecting the incidence of ADR.Results After systematic screening and pharmacist review,a total of 598 cases of ADR related to first-line anti-tuberculosis drugs were found,with an incidence of 52.14%.ADR mainly affects the endocrine system,digestive system,and hepatobiliary system.The incidence of ADR in oral isoniazid is higher than that in intravenous drip and nebulization routes.The results of multivariate regression analysis showed that women and a history of hepatitis were independent risk factors for the occurrence of ADR(all P<0.05).Conclusion The incidence of ADR with anti-tuberculosis drugs is high.Women and patients with a history of hepatitis are high-risk groups for adverse drug reactions to anti-tuberculosis drugs.In clinical,safer drugs should be selected for such patients,and the occurrence of ADR should be closely monitored to reduce the impact of ADR on the treatment process.
10.HPLC-MS/MS method for monitoring digoxin in children with small volume of plasma
Zhi-Mei YANG ; Zhang-Ying FENG ; Ya-Bin QIN
The Chinese Journal of Clinical Pharmacology 2024;40(9):1331-1335
Objective To establish a high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method for therapeutic drug monitoring(TDM)of digoxin in children.Methods The plasma samples 10 μL were precipitated protein by acetonitrile.Then,the analytes were gradient eluted on a Phenomenex Kinetex EVO C18 column(30.0 mm × 2.1 mm,2.6 μm)by HPLC-MS/MS with mobile phase consisted of water(0.05%formic acid and 2 mmol·L-1 ammonium acetate)-methanol at the flow rate of 0.55 mL·min-1.The mass detection was performed in positive ionization mode using the electrospray ionization(ESI)source.Dynamic multiple reaction monitoring mode(dMRM)was used to quantify at m/z 798.6→651.5(digoxin)and m/z 801.6→654.5(digoxin-d3),respectively.The selectivity,standard curve,precision and extraction recoveries,matrix effect,and stability were investigated.Results The retention time of both digoxin and internal standard was 1.39 min.The linear range of digoxin in human plasma was among 0.25-8.00 ng·mL-1,a typical standard curve was y=18.08 × 10-2x+29.71 × 10-4(r2=0.995 77).The intra-day and inter-day accuracies of digoxin were less than 15%Extraction recovery rate was 91.00%-99.50%.Stability studies showed good results.Matrix factor normalized by internal standard was within acceptance criteria.The measurement results were in line with the national requirement of External quality evaluation.This method was fully verified and applied to determine the plasma digoxin concentrations of 65 pediatric patients.Conclusion This LC-MS/MS method was simple,rapid and accurate.It is approved appropriate and practical for the therapeutic drug monitoring of digoxin in routine clinical laboratory practice,especially for children.


Result Analysis
Print
Save
E-mail