1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Synthesis and characterization of matrix metalloproteinase-responsive BDNF controlled-release materials
Jun-Ru HEI ; Cui WANG ; Meng-Wen SONG ; Sheng-Qiang XIE ; Bing-Xian WANG ; Xiao-Juan LAN ; Han-Bo ZHANG ; Gang CHENG ; Zhi-Qiang LIU ; Xi-Qin YANG ; Jian-Ning ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(11):1319-1326
Objective To develop a matrix metalloproteinase(MMP)-responsive hyaluronic acid(HA)-based controlled-release material for brain-derived neurotrophic factor(BDNF)to provide a novel therapeutic strategy for intervention and repair of traumatic brain injury(TBI).Methods HA was modified with amination,followed by condensation with Suflo-SMCC carboxyl group to form amide,and then linked with glutathione(GSH)to synthesize HA-GSH.The recombinant glutathione S-transferase(GST)-tissue inhibitor of metalloproteinase(TIMP)-BDNF(GST-TIMP-BDNF)expression plasmid was constructed using molecular cloning technique with double enzyme digestion by Bam H Ⅰ and Eco R Ⅰ.The recombinant GST-TIMP-BDNF protein was expressed in the Escherichia coli prokaryotic expression system,and purified by ion exchange chromatography,confirmed by Western blotting.MMP diluents were supplemented with PBS,MMP inhibitor marimastat,and varing concentrations(0.4,0.6,0.8 mg/ml)of GST-TIMP-BDNF or GST-BDNF.MMP-2 activity was analyzed using an MMP activity detection kit to evaluate the inhibitory effect of the recombinant protein on MMP.Primary rat neurons were extracted and cultured to establish an iron death model induced by RSL3.The effect of recombinant protein GST-TIMP-BDNF on neuronal injury was detected by immunofluorescence staining.Results MRI hydrogen spectrum identification confirmed the successful synthesis of HA-GSH.Western blotting results showed the successful expression of the recombinant protein GST-TIMP-BDNF containing the GST tag using the E.coli prokaryotic expression system.MMP activity detection results indicated that the recombinant protein GST-TIMP-BDNF had a superior inhibitory effect on MMP-2 activity compared to GST-BDNF(P<0.05).Immunofluorescence staining results showed a significant increase in fluorescence intensity in rat neurons treated with GST-TIMP-BDNF after RSL3 induction(P<0.05).Conclusion A MMP-responsive HA-based BDNF controlled-release material has been successfully developed,exhibiting a protective effect on neuron damage.
7.Rapid promyelocytic blast crisis of chronic myeloid leukemia with PML-RARα fusion gene: a case report and literature review.
Ming Suo LIU ; Xiao Yan HAN ; Zhi Gang QU ; Qiu Lian LUO ; Kang Li WU ; Jin CHEN ; Ya Jun WU ; Wan Ling XU ; Xi Xi YANG ; Yuan Yuan ZHU
Chinese Journal of Hematology 2023;44(6):512-515
8.Effects of three-dimensional bioprinting antibacterial hydrogel on full-thickness skin defect wounds in rats.
Rong Hua JIN ; Zhen Zhen ZHANG ; Peng Qin XU ; Si Zhan XIA ; Ting Ting WENG ; Zhi Kang ZHU ; Xin Gang WANG ; Chuan Gang YOU ; Chun Mao HAN
Chinese Journal of Burns 2023;39(2):165-174
Objective: To explore the effects of three-dimensional (3D) bioprinting gelatin methacrylamide (GelMA) hydrogel loaded with nano silver on full-thickness skin defect wounds in rats. Methods: The experimental research method was adopted. The morphology, particle diameter, and distribution of silver nanoparticles in nano silver solution with different mass concentrations and the pore structure of silver-containing GelMA hydrogel with different final mass fractions of GelMA were observed by scanning electron microscope and the pore size was calculated. On treatment day 1, 3, 7, and 14, the concentration of nano silver released from the hydrogel containing GelMA with final mass fraction of 15% and nano silver with final mass concentration of 10 mg/L was detected by mass spectrometer. At 24 h of culture, the diameters of inhibition zone of GelMA hydrogel containing final mass concentration of 0 (no nano silver), 25, 50, and 100 mg/L nano silver against Staphylococcus aureus and Escherichia coli were detected. Fibroblasts (Fbs) and adipose stem cells (ASCs) were isolated respectively by enzymatic digestion using the discarded prepuce after circumcision from a 5-year-old healthy boy who was treated in the Department of Urology of the Second Affiliated Hospital of Zhejiang University School of Medicine in July 2020, and the discarded fat tissue after liposuction from a 23-year-old healthy woman who was treated in the Department of Plastic Surgery of the Hospital in July 2020. The Fbs were divided into blank control group (culture medium only), 2 mg/L nano sliver group, 5 mg/L nano sliver group, 10 mg/L nano sliver group, 25 mg/L nano sliver group, and 50 mg/L nano sliver group, which were added with the corresponding final mass concentrations of nano sliver solution, respectively. At 48 h of culture, the Fb proliferation viability was detected by cell counting kit 8 method. The Fbs were divided into 0 mg/L silver-containing GelMA hydrogel group, 10 mg/L silver-containing GelMA hydrogel group, 50 mg/L silver-containing GelMA hydrogel group, and 100 mg/L silver-containing GelMA hydrogel group and then were correspondingly treated. On culture day 1, 3, and 7, the Fb proliferation viability was detected as before. The ASCs were mixed into GelMA hydrogel and divided into 3D bioprinting group and non-printing group. On culture day 1, 3, and 7, the ASC proliferation viability was detected as before and cell growth was observed by live/dead cell fluorescence staining. The sample numbers in the above experiments were all 3. Four full-thickness skin defect wounds were produced on the back of 18 male Sprague-Dawley rats aged 4 to 6 weeks. The wounds were divided into hydrogel alone group, hydrogel/nano sliver group, hydrogel scaffold/nano sliver group, and hydrogel scaffold/nano sliver/ASC group, and transplanted with the corresponding scaffolds, respectively. On post injury day (PID) 4, 7, 14, and 21, the wound healing was observed and the wound healing rate was calculated (n=6). On PID 7 and 14, histopathological changes of wounds were observed by hematoxylin eosin staining (n=6). On PID 21, collagen deposition of wounds was observed by Masson staining (n=3). Data were statistically analyzed with one-way analysis of variance, analysis of variance for repeated measurement, Bonferroni correction, and independent sample t test. Results: The sliver nano particles in nano silver solution with different mass concentrations were all round, in scattered distribution and uniform in size. The silver-containing GelMA hydrogels with different final mass fractions of GelMA all showed pore structures of different sizes and interconnections. The pore size of silver-containing GelMA hydrogel with 10% final mass fraction was significantly larger than that of silver-containing GelMA hydrogels with 15% and 20% final mass fractions (with P values both below 0.05). On treatment day 1, 3, and 7, the concentration of nano silver released from silver-containing GelMA hydrogel in vitro showed a relatively flat trend. On treatment day 14, the concentration of released nano silver in vitro increased rapidly. At 24 h of culture, the diameters of inhibition zone of GelMA hydrogel containing 0, 25, 50, and 100 mg/L nano silver against Staphylococcus aureus and Escherichia coli were 0, 0, 0.7, and 2.1 mm and 0, 1.4, 3.2, and 3.3 mm, respectively. At 48 h of culture, the proliferation activity of Fbs in 2 mg/L nano silver group and 5 mg/L nano silver group was both significantly higher than that in blank control group (P<0.05), and the proliferation activity of Fbs in 10 mg/L nano silver group, 25 mg/L nano silver group, and 50 mg/L nano silver group was all significantly lower than that in blank control group (P<0.05). Compared with the that of Fbs in 0 mg/L silver-containing GelMA hydrogel group, the proliferation activity of Fbs in 50 mg/L silver-containing GelMA hydrogel group and 100 mg/L silver-containing GelMA hydrogel group was all significantly decreased on culture day 1 (P<0.05); the proliferation activity of Fbs in 50 mg/L silver-containing GelMA hydrogel group was significantly increased (P<0.05), while the proliferation activity of Fbs in 100 mg/L silver-containing GelMA hydrogel group was significantly decreased on culture day 3 (P<0.05); the proliferation activity of Fbs in 100 mg/L silver-containing GelMA hydrogel group was significantly decreased on culture day 7 (P<0.05). The proliferation activity of ASCs in 3D bioprinting group show no statistically significant differences to that in non-printing group on culture day 1 (P>0.05). The proliferation activity of ASCs in 3D bioprinting group was significantly higher than that in non-printing group on culture day 3 and 7 (with t values of 21.50 and 12.95, respectively, P<0.05). On culture day 1, the number of dead ASCs in 3D bioprinting group was slightly more than that in non-printing group. On culture day 3 and 5, the majority of ASCs in 3D bioprinting group and non-printing group were living cells. On PID 4, the wounds of rats in hydrogel alone group and hydrogel/nano sliver group had more exudation, and the wounds of rats in hydrogel scaffold/nano sliver group and hydrogel scaffold/nano sliver/ASC group were dry without obvious signs of infection. On PID 7, there was still a small amount of exudation on the wounds of rats in hydrogel alone group and hydrogel/nano sliver group, while the wounds of rats in hydrogel scaffold/nano sliver group and hydrogel scaffold/nano sliver/ASC group were dry and scabbed. On PID 14, the hydrogels on the wound surface of rats in the four groups all fell off. On PID 21, a small area of wounds remained unhealed in hydrogel alone group. On PID 4 and 7, the wound healing rates of rats in hydrogel scaffold/nano sliver/ASC group were significantly higher than those of the other three groups (P<0.05). On PID 14, the wound healing rate of rats in hydrogel scaffold/nano sliver/ASC group was significantly higher than the wound healing rates in hydrogel alone group and hydrogel/nano sliver group (all P<0.05). On PID 21, the wound healing rate of rats in hydrogel alone group was significantly lower than that in hydrogel scaffold/nano sliver/ASC group (P<0.05). On PID 7, the hydrogels on the wound surface of rats in the four groups remained in place; on PID 14, the hydrogel in hydrogel alone group was separated from the wounds of rats, while some hydrogels still existed in the new tissue of the wounds of rats in the other three groups. On PID 21, the collagen arrangement in the wounds of rats in hydrogel alone group was out of order, while the collagen arrangement in the wounds of rats in hydrogel/nano sliver group, and hydrogel scaffold/nano sliver/ASC group was relatively orderly. Conclusions: Silver-containing GelMA hydrogel has good biocompatibility and antibacterial properties. Its three-dimensional bioprinted double-layer structure can better integrate with new formed tissue in the full-thickness skin defect wounds in rats and promote wound healing.
Male
;
Rats
;
Animals
;
Humans
;
Hydrogels/pharmacology*
;
Bioprinting
;
Metal Nanoparticles
;
Rats, Sprague-Dawley
;
Silver/pharmacology*
;
Soft Tissue Injuries
;
Anti-Bacterial Agents
9.The value of transanal multipoint full-layer puncture biopsy in determining the response degree of rectal cancer following neoadjuvant therapy: a prospective multicenter study.
Jia Gang HAN ; Li Ting SUN ; Zhi Wei ZHAI ; Ping Dian XIA ; Hang HU ; Di ZHANG ; Cong Qing JIANG ; Bao Cheng ZHAO ; Hao QU ; Qun QIAN ; Yong DAI ; Hong Wei YAO ; Zhen Jun WANG
Chinese Journal of Surgery 2023;61(9):769-776
Objective: To verify the feasibility and accuracy of the transanal multipoint full-layer puncture biopsy (TMFP) technique in determining the residual status of cancer foci after neoadjuvant therapy (nCRT) in rectal cancer. Methods: Between April 2020 and November 2022, a total of 78 patients from the Beijing Chaoyang Hospital of Capital Medical University, the Beijing Friendship Hospital of Capital Medical University, the Qilu Hospital of Shandong University, the Zhongnan Hospital of Wuhan University with advanced rectal cancer received TMFP after nCRT participated in this prospective multicenter trial. There were 53 males and 25 females, aged (M(IQR)) 61 (13) years (range: 35 to 77 years). The tumor distance from the anal verge was 5 (3) cm (range: 2 to 10 cm). The waiting time between nCRT and TMFP was 73 (26) days (range: 33 to 330 days). 13-point transanal puncture was performed with a 16 G tissue biopsy needle with the residual lesion as the center. The specimens were submitted for independent examination and the complications of the puncture were recorded. The consistency of TMFP and radical operation specimen was compared. The consistency of TMPF with clinical remission rates for the diagnosis of complete pathological remission was compared by sensitivity, specificity, negative predictive value, positive predictive value and accuracy. Statistical analysis between groups was performed using the χ2 analysis, and a paired χ2 test was used to compare diagnostic validity. Results: Before TMFP, clinical complete response (cCR) was evaluated in 27 cases. Thirty-six cases received in vivo puncture, the number of punctures in each patient was 13 (8) (range: 4 to 20), 24 cases of tumor residue were found in the puncture specimens. The sensitivity to judgment (100% vs. 60%, χ2=17.500, P<0.01) and accuracy (88.5% vs. 74.4%, χ2=5.125, P=0.024) of TMFP for the pathologic complete response (pCR) were significantly higher than those of cCR. Implement TMFP based on cCR judgment, the accuracy increased from 74.4% to 92.6% (χ2=4.026, P=0.045). The accuracy of the in vivo puncture was 94.4%, which was 83.3% of the in vitro puncture (χ2=1.382, P=0.240). Overall, the accuracy of TMFP improved gradually with an increasing number of cases (χ2=7.112, P=0.029). Conclusion: TMFP is safe and feasible, which improves the sensitivity and accuracy of rectal cancer pCR determination after nCRT, provides a pathological basis for cCR determination, and contributes to the safe development of the watch and wait policy.
10.Efficacy of high-dose dual therapy for Helicobacter pylori infection eradication in servicemen: a randomized controlled trial.
Xiao Mei ZHANG ; Han Chen MIN ; Jing CHEN ; Jun Li ZHI ; Hong Xia DONG ; Jin Yan KONG ; Jiang Yun MENG ; Gang SUN ; Zi Kai WANG ; Fei PAN ; Li Hua PENG ; Yun Sheng YANG
Chinese Journal of Internal Medicine 2023;62(5):520-525
Objective: To assess the efficacy and cost-effectiveness of high-dose dual therapy compared with bismuth-containing quadruple therapy for treating Helicobacter pylori(H.pylori) infection in servicemen patients. Methods: A total of 160 H. pylori-infected, treatment-naive servicemen, including 74 men and 86 women, aged from 20 years to 74 years, with a mean (SD) age of 43 (13) years, tested in the First Center of Chinese PLA General Hospital from March 2022 to May 2022 were enrolled in this open-label, randomized controlled clinical trial. Patients were randomly allocated into 2 groups: the 14-day high-dose dual therapy group and the bismuth-containing quadruple therapy group. Eradication rates, adverse events, patient compliance, and drug costs were compared between the two groups. The t-test was used for continuous variables, and the Chi-square test for categorical variables. Results: No significant difference in H. pylori eradication rates were found between high-dose dual therapy and bismuth-containing quadruple therapy by ITT, mITT and PP analysis[ITT:90.0% (95%CI 81.2%-95.6%) vs. 87.5% (95%CI 78.2%-93.8%), χ2=0.25, P=0.617;mITT:93.5% (95%CI 85.5%-97.9%) vs. 93.3% (95%CI 85.1%-97.8%), χ2<0.01, P=1.000; PP: 93.5% (95%CI 85.5%-97.9%) vs. 94.5% (95%CI 86.6%-98.5%), χ2<0.01, P=1.000 ]. The dual therapy group exhibited significantly less overall side effects compared with the quadruple therapy group [21.8% (17/78) vs. 38.5% (30/78), χ2=5.15,P=0.023]. There were no significant differences in the compliance rates between the two groups [98.7%(77/78) vs. 94.9%(74/78), χ2=0.83,P=0.363]. The cost of medications in the dual therapy was 32.0% lower compared with that in the quadruple therapy (472.10 RMB vs. 693.94 RMB). Conclusions: The dual regimen has a favorable effect on the eradication of H. pylori infection in servicemen patients. Based on the ITT analysis, the eradication rate of the dual regimen is grade B (90%, good). Additionally, it exhibited a lower incidence of adverse events, better compliance and significantly reduced cost. The dual regimen is expected to be a new choice for the first-line treatment of H. pylori infection in servicemen but needs further evaluation.
Male
;
Humans
;
Female
;
Young Adult
;
Adult
;
Helicobacter Infections
;
Helicobacter pylori
;
Bismuth
;
Anti-Bacterial Agents/therapeutic use*
;
Amoxicillin/adverse effects*
;
Drug Therapy, Combination
;
Treatment Outcome
;
Proton Pump Inhibitors/therapeutic use*

Result Analysis
Print