1.The effect of rutaecarpine on improving fatty liver and osteoporosis in MAFLD mice
Yu-hao ZHANG ; Yi-ning LI ; Xin-hai JIANG ; Wei-zhi WANG ; Shun-wang LI ; Ren SHENG ; Li-juan LEI ; Yu-yan ZHANG ; Jing-rui WANG ; Xin-wei WEI ; Yan-ni XU ; Yan LIN ; Lin TANG ; Shu-yi SI
Acta Pharmaceutica Sinica 2025;60(1):141-149
		                        		
		                        			
		                        			 Metabolic-associated fatty liver disease (MAFLD) and osteoporosis (OP) are two very common metabolic diseases. A growing body of experimental evidence supports a pathophysiological link between MAFLD and OP. MAFLD is often associated with the development of OP. Rutaecarpine (RUT) is one of the main active components of Chinese medicine Euodiae Fructus. Our previous studies have demonstrated that RUT has lipid-lowering, anti-inflammatory and anti-atherosclerotic effects, and can improve the OP of rats. However, whether RUT can improve both fatty liver and OP symptoms of MAFLD mice at the same time remains to be investigated. In this study, we used C57BL/6 mice fed a high-fat diet (HFD) for 4 months to construct a MAFLD model, and gave the mice a low dose (5 mg·kg-1) and a high dose (15 mg·kg-1) of RUT by gavage for 4 weeks. The effects of RUT on liver steatosis and bone metabolism were then evaluated at the end of the experiment [this experiment was approved by the Experimental Animal Ethics Committee of Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences (approval number: IMB-20190124D303)]. The results showed that RUT treatment significantly reduced hepatic steatosis and lipid accumulation, and significantly reduced bone loss and promoted bone formation. In summary, this study shows that RUT has an effect of improving fatty liver and OP in MAFLD mice. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
7.Evolution of chemistry and selection technology for DNA-encoded library.
Peixiang MA ; Shuning ZHANG ; Qianping HUANG ; Yuang GU ; Zhi ZHOU ; Wei HOU ; Wei YI ; Hongtao XU
Acta Pharmaceutica Sinica B 2024;14(2):492-516
		                        		
		                        			
		                        			DNA-encoded chemical library (DEL) links the power of amplifiable genetics and the non-self-replicating chemical phenotypes, generating a diverse chemical world. In analogy with the biological world, the DEL world can evolve by using a chemical central dogma, wherein DNA replicates using the PCR reactions to amplify the genetic codes, DNA sequencing transcripts the genetic information, and DNA-compatible synthesis translates into chemical phenotypes. Importantly, DNA-compatible synthesis is the key to expanding the DEL chemical space. Besides, the evolution-driven selection system pushes the chemicals to evolve under the selective pressure, i.e., desired selection strategies. In this perspective, we summarized recent advances in expanding DEL synthetic toolbox and panning strategies, which will shed light on the drug discovery harnessing in vitro evolution of chemicals via DEL.
		                        		
		                        		
		                        		
		                        	
8. Study on spleen strengthening effects and mechanisms of Atractylodes chinensis and Atractylodes coreana
Ming-Yang CUI ; Yi-Hui DING ; Yang QU ; Zhi-Li XU ; Qian CAI
Chinese Pharmacological Bulletin 2024;40(1):181-188
		                        		
		                        			
		                        			 Aim To analyze the differences in plasma biomarkers and metabolic pathways between Atractylodes chinensis and Atractylodes coreana after intervention in spleen deficiency rats, and discuss the spleen strengthening mechanism of the two from a non targeted metabolomics perspective. Methods A spleen deficiency model was established in SD rats using a composite factor method of improper diet, excessive fatigue, and bitter cold diarrhea. To determine the content of gastrointestinal and immunological indicators, UHPLC-QE-MS technology was used, combined with principal component analysis (PC A) and orthogonal projections to latent structures-discriminant analysis (OPLS-DA) methods to search for biomarkers in plasma of spleen deficiency rats, and metabolic pathways were induced using the Pathway database. Results After administration of Atractylodes chinensis and Atractylodes coreana, various indicators in plasma of spleen deficiency rats showed varying degrees of regression. Metabolomics analysis showed that Atractylodes chinensis and Atractylodes coreana respectively recalled 70 and 82 plasma differential metabolites. Atractylodes chinensis mainly regulated two metabolic pathways : "Glycine, serine, and threonine metabolism, and "Thiamine metabolism". Atractylodes coreana mainly regulated five metabolic pathways, "Glycine, serine, and threonine metabolism", "Thiamine metabolism, "Pyrimidine metabolism", "Butanoate metabolism", and "Riboflavin metabolism". Conclusions Both Atractylodes chinensis and Atractylodes coreana have certain regulatory effects on spleen deficiency rats, and their mechanism of action may be related to regulating metabolic pathways such as "Glycine, serine, and threonine metabolism, and "Thiamine metabolism"in spleen deficiency. 
		                        		
		                        		
		                        		
		                        	
9.Extraction process,enzymatic properties and practical application of glucuronic hydrolase in Scutellaria baicalensis stems and leaves
Yu-Jie CHENG ; Xu CHEN ; Yun-Hua LIU ; Zhi-Fang HUANG ; Yan CHEN ; Yu-Hong LIU ; Jin-Hai YI
Chinese Traditional Patent Medicine 2024;46(1):35-40
		                        		
		                        			
		                        			AIM To study the extraction process,enzymatic properties and practical application of glucuronic hydrolase in Scutellaria baicalensis stems and leaves(sbsl GUS).METHODS With granularity,water consumption,extraction time and extraction frequency as influencing factors,enzymatic activity as an evaluation index,the extraction process was optimized by orthogonal test on the basis of single factor test.The relationship between substrate(baicalin)concentration and enzymolysis rate,after which Vmax and Km were calculated,the effects of pH value,temperature and metal ion on enzymatic activity were investigated,pH stability and heat stability were evaluated.sbsl GUS was adotped in the enzymolysis of baicalin to prepare baicalein,then the effects of pH value,temperature,reaction time,initial substrate concentration and enzyme addition on transfer rate were investigated.RESULTS The optimal extraction process was determined to be 40 mesh for granularity,10 times for water consumption,15 min for extraction time,and 3 times for extraction frequency.The enzymolysis accorded with the kinetics of enzymatic reaction,Km was 0.006 3 mol/L,Vmax was 70.42 μmol/h,the strongest enzymatic activity was found at the pH value of 6.0,temperature of 45℃and metal ion of 100 mmol/L Cu2+,sbsl GUS demonstrated good stability at the ranges of 4.0-7.0 for pH value and 4-30℃for temperature.The optimal preparation process was determined to be 6.0 for pH value,45℃for temperature,more than 12 h for reaction time,67.2 mmol/L for initial substrate concentration,and 1 mL/0.269 mmol baicalin for enzyme addition,the transfer rate was 97.83%.CONCLUSION sbsl GUS enzymolysis exhibits high efficiency and mild condition,which can provide a simple preparation method for obtaining baicalein,and expand the application path of Scutellaria baicalensis stems and leaves.
		                        		
		                        		
		                        		
		                        	
10.Expression of PLCD3 mRNA in synovium of osteoarthritis and its relationship with immune cell infiltration
Pu YING ; Zhi ZHENG ; Yue XU ; Ye ZHOU ; Yufan GE ; Yi XUE ; Yiming MIAO
International Journal of Laboratory Medicine 2024;45(2):208-212
		                        		
		                        			
		                        			Objective To investigate the expression of PLCD3 mRNA in the synovium of osteoarthritis(OA)and its relationship with immune cell infiltration.Methods Based on the differentially expressed genes of OA found in the previous study,the expression of phospholipase Cδ3(PLCD3)mRNA was detected by col-lecting synovial samples from OA group and control group.CIBERSORT algorithm was used to analyze the infiltration pattern of immune cells in OA group and control group,and the correlation between PLCD3 and infiltrating immune cells was further analyzed.Results Compared with the control group,the relative expres-sion level of PLCD3 mRNA was significantly increased in synovial samples of OA group(P<0.05).The pro-portions of B cells naive,NK cells activated,M2 macrophages and mast cells activated in synovial tissues of OA group were relatively high(P<0.05).PLCD3 was positively correlated with the proportion of these four immune cells(P<0.05).Conclusion PLCD3 may be a key biomarker for the diagnosis of OA,which may be involved in the pathogenesis of OA by interacting with infiltrating immune cells.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail