1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Trend in testicular volume change after orchiopexy in 854 children with cryptorchidism.
Ying-Ying HE ; Zhi-Cong KE ; Shou-Lin LI ; Hui-Jie GUO ; Pei-Liang ZHANG ; Peng-Yu CHEN ; Wan-Hua XU ; Feng-Hao SUN ; Zhi-Lin YANG
Asian Journal of Andrology 2025;27(6):723-727
The aim of this study was to investigate the trend in testicular volume changes after orchiopexy in children with cryptorchidism. The clinical data of 854 children with cryptorchidism who underwent orchiopexy between January 2013 and December 2016 in Shenzhen Children's Hospital (Shenzhen, China) were retrospectively analyzed. The mean (standard deviation) age of the patients was 2.8 (2.5) years, and the duration of follow-up ranged from 1 year to 5 years. Ultrasonography was conducted preoperatively and postoperatively. The variables analyzed included age at the time of surgery, type of surgical procedure, laterality, preoperative testicular position, preoperative and postoperative testicular volumes, and the testicular volume ratio of them. The average testicular volumes preoperatively and at 1 year, 2 years, 3 years, and 5 years postoperatively were 0.27 ml, 0.38 ml, 0.53 ml, 0.87 ml, and 1.00 ml, respectively ( P < 0.001). The corresponding testicular volume ratios were 0.67, 0.76, 0.80, 0.83, and 0.84 ( P < 0.001). The mean volume of the undescended testes was significantly smaller than the mean normative value ( P < 0.001, lower than the 10 th percentile). The postoperative testicular volumes in children with cryptorchidism were generally lower than those in healthy boys but were still greater than the 10 th percentile and exhibited an increasing trend. The older the child is at the time of surgery, the larger the gap in volume between the affected and normal testes. Although testicular volume tends to gradually increase after orchiopexy for cryptorchidism, it could not normalizes. Earlier surgery results in affected testicular volumes closer to those of healthy boys.
Humans
;
Male
;
Cryptorchidism/diagnostic imaging*
;
Orchiopexy
;
Child, Preschool
;
Testis/surgery*
;
Retrospective Studies
;
Organ Size
;
Ultrasonography
;
Infant
;
Child
;
Postoperative Period
;
Follow-Up Studies
7.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
8.Effect of Kuanxiong Aerosol on Perioperative Coronary Microcirculation in Patients with Unstable Angina Undergoing Elective PCI: A Pilot Randomized Controlled Trial.
Zi-Hao LIU ; Wen-Long XING ; Hong-Xu LIU ; Ju-Ju SHANG ; Ai-Yong LI ; Qi ZHOU ; Zhen-Min ZHANG ; Zhi-Bao LI ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(3):206-214
OBJECTIVE:
To evaluate the immediate effect of Kuanxiong Aerosol (KXA) on perioperative coronary microcirculation in patients with unstable angina (UA) suffering from elective percutaneous coronary intervention (PCI).
METHODS:
From February 2021 to July 2023, UA inpatients who underwent PCI alone in the left anterior descending (LAD) branch were included. Random numbers were generated to divide patients into the trial group and the control group at a ratio of 1:1. The index of coronary microcirculation resistance (IMR) was measured before PCI, and the trial group was given two sprays of KXA, while the control group was not given. IMR was measured again after PCI, cardiac troponin I (cTnI) and creatine kinase isoenzyme-MB (CK-MB) were detected before and 24 h after surgery, and major cardiovascular adverse events (MACEs) were recorded for 30 days. The data statistics and analysis personnel were blinded.
RESULTS:
Totally 859 patients were screened, and 62 of them were involved into this study. Finally, 1 patient in the trial group failed to complete the post-PCI IMR and was excluded, 30 patients were included for data analysis, while 31 patients in the control group were enrolled in data analysis. There was no significant difference in baseline data (age, gender, risk factors, previous history, biochemical index, and drug therapy, etc.) between the two groups. In addition, differences in IMR, cTnI and CK-MB were not statistically significant between the two groups before surgery. After PCI, the IMR level of the trial group was significantly lower than that of the control group (19.56 ± 14.37 vs. 27.15 ± 15.03, P=0.048). Besides, the incidence of perioperative myocardial injury (PMI) was lower in the trial group, but the difference was not statistically significant (6.67% vs. 16.13%, P=0.425). No MACEs were reported in either group.
CONCLUSIONS
KXA has the potential of improving coronary microvascular dysfunction. This study provides reference for the application of KXA in UA patients undergoing elective PCI. (Registration No. ChiCTR2300069831).
Humans
;
Percutaneous Coronary Intervention
;
Male
;
Microcirculation/drug effects*
;
Female
;
Angina, Unstable/physiopathology*
;
Pilot Projects
;
Middle Aged
;
Aged
;
Drugs, Chinese Herbal/pharmacology*
;
Aerosols
;
Troponin I/blood*
;
Coronary Circulation/drug effects*
;
Elective Surgical Procedures
9.Analysis of Serum Metabolic Biomarkers in Adult Patients with Kashin-Beck Disease and Degenerative Osteoarthritis in Qinghai Province.
Jia le XU ; Qiang LI ; Chuan LU ; Xin ZHOU ; Yan Mei ZHAO ; Jian Ling WANG ; Ji Quan LI ; Li MA ; Zhi Jun ZHAO ; Ke Wen LI
Biomedical and Environmental Sciences 2025;38(9):1173-1177
10.Toxicokinetics of MDMA and Its Metabolite MDA in Rats
Wei-Guang YU ; Qiang HE ; Zheng-Di WANG ; Cheng-Jun TIAN ; Jin-Kai WANG ; Qian ZHENG ; Fei REN ; Chao ZHANG ; You-Mei WANG ; Peng XU ; Zhi-Wen WEI ; Ke-Ming YUN
Journal of Forensic Medicine 2024;40(1):37-42
Objective To investigate the toxicokinetic differences of 3,4-methylenedioxy-N-methylamphetamine(MDMA)and its metabolite 4,5-methylene dioxy amphetamine(MDA)in rats af-ter single and continuous administration of MDMA,providing reference data for the forensic identifica-tion of MDMA.Methods A total of 24 rats in the single administration group were randomly divided into 5,10 and 20 mg/kg experimental groups and the control group,with 6 rats in each group.The ex-perimental group was given intraperitoneal injection of MDMA,and the control group was given intraperi-toneal injection of the same volume of normal saline as the experimental group.The amount of 0.5 mL blood was collected from the medial canthus 5 min,30 min,1 h,1.5 h,2 h,4 h,6 h,8 h,10 h,12 h after administration.In the continuous administration group,24 rats were randomly divided into the experi-mental group(18 rats)and the control group(6 rats).The experimental group was given MDMA 7 d by continuous intraperitoneal injection in increments of 5,7,9,11,13,15,17 mg/kg per day,respectively,while the control group was given the same volume of normal saline as the experimental group by in-traperitoneal injection.On the eighth day,the experimental rats were randomly divided into 5,10 and 20 mg/kg dose groups,with 6 rats in each group.MDMA was injected intraperitoneally,and the con-trol group was injected intraperitoneally with the same volume of normal saline as the experimental group.On the eighth day,0.5 mL of blood was taken from the medial canthus 5 min,30 min,1 h,1.5 h,2 h,4 h,6 h,8 h,10 h,12 h after administration.Liquid chromatography-triple quadrupole tandem mass spectrometry was used to detect MDMA and MDA levels,and statistical software was employed for data analysis.Results In the single-administration group,peak concentrations of MDMA and MDA were reached at 5 min and 1 h after administration,respectively,with the largest detection time limit of 12 h.In the continuous administration group,peak concentrations were reached at 30 min and 1.5 h af-ter administration,respectively,with the largest detection time limit of 10 h.Nonlinear fitting equations for the concentration ratio of MDMA and MDA in plasma and administration time in the single-administration group and continuous administration group were as follows:T=10.362C-1.183,R2=0.974 6;T=7.397 3C-0.694,R2=0.961 5(T:injection time;C:concentration ratio of MDMA to MDA in plasma).Conclusions The toxicokinetic data of MDMA and its metabolite MDA in rats,obtained through single and continuous administration,including peak concentration,peak time,detection time limit,and the relationship between concentration ratio and administration time,provide a theoretical and data foundation for relevant forensic identification.