1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Toxicokinetics of MDMA and Its Metabolite MDA in Rats
Wei-Guang YU ; Qiang HE ; Zheng-Di WANG ; Cheng-Jun TIAN ; Jin-Kai WANG ; Qian ZHENG ; Fei REN ; Chao ZHANG ; You-Mei WANG ; Peng XU ; Zhi-Wen WEI ; Ke-Ming YUN
Journal of Forensic Medicine 2024;40(1):37-42
Objective To investigate the toxicokinetic differences of 3,4-methylenedioxy-N-methylamphetamine(MDMA)and its metabolite 4,5-methylene dioxy amphetamine(MDA)in rats af-ter single and continuous administration of MDMA,providing reference data for the forensic identifica-tion of MDMA.Methods A total of 24 rats in the single administration group were randomly divided into 5,10 and 20 mg/kg experimental groups and the control group,with 6 rats in each group.The ex-perimental group was given intraperitoneal injection of MDMA,and the control group was given intraperi-toneal injection of the same volume of normal saline as the experimental group.The amount of 0.5 mL blood was collected from the medial canthus 5 min,30 min,1 h,1.5 h,2 h,4 h,6 h,8 h,10 h,12 h after administration.In the continuous administration group,24 rats were randomly divided into the experi-mental group(18 rats)and the control group(6 rats).The experimental group was given MDMA 7 d by continuous intraperitoneal injection in increments of 5,7,9,11,13,15,17 mg/kg per day,respectively,while the control group was given the same volume of normal saline as the experimental group by in-traperitoneal injection.On the eighth day,the experimental rats were randomly divided into 5,10 and 20 mg/kg dose groups,with 6 rats in each group.MDMA was injected intraperitoneally,and the con-trol group was injected intraperitoneally with the same volume of normal saline as the experimental group.On the eighth day,0.5 mL of blood was taken from the medial canthus 5 min,30 min,1 h,1.5 h,2 h,4 h,6 h,8 h,10 h,12 h after administration.Liquid chromatography-triple quadrupole tandem mass spectrometry was used to detect MDMA and MDA levels,and statistical software was employed for data analysis.Results In the single-administration group,peak concentrations of MDMA and MDA were reached at 5 min and 1 h after administration,respectively,with the largest detection time limit of 12 h.In the continuous administration group,peak concentrations were reached at 30 min and 1.5 h af-ter administration,respectively,with the largest detection time limit of 10 h.Nonlinear fitting equations for the concentration ratio of MDMA and MDA in plasma and administration time in the single-administration group and continuous administration group were as follows:T=10.362C-1.183,R2=0.974 6;T=7.397 3C-0.694,R2=0.961 5(T:injection time;C:concentration ratio of MDMA to MDA in plasma).Conclusions The toxicokinetic data of MDMA and its metabolite MDA in rats,obtained through single and continuous administration,including peak concentration,peak time,detection time limit,and the relationship between concentration ratio and administration time,provide a theoretical and data foundation for relevant forensic identification.
7.Blocking performance test method of disposable check valves for infusion equipment
Xi-Yun DANG ; Su-Hua XU ; Xue BAI ; Jun KE ; Zhi TANG ; Shan FENG ; Shuo-Han LIN
Chinese Medical Equipment Journal 2024;45(9):78-83
YY 0585.4-2009 and ISO 8536-12:2021 standards were compared in terms of the blocking performance test method of disposable check valves for infusion equipment.The affecting factors and possible errors were analyzed when the blocking performance test was carried out according to YY 0585.4-2009,and it's pointed out ISO 8536-12:2021 gained advantages over YY 0585.4-2009 in the blocking performance test method of check valves.References and guidance were provided for standard revision and actual operation.[Chinese Medical Equipment Journal,2024,45(9):78-83]
8.Chemical constituents from the leaves of Citrus reticulata and their anti-inflammatory activities
Fa-Ke YANG ; Xing YANG ; Zhi-Bi ZHANG ; Rui YIN ; Hong-Chuan ZHANG ; Xu-Li DENG ; Wei-Mao DONG ; Yi-Mou WANG ; Hong-Ping HE ; Fa-Wu DONG
Chinese Traditional Patent Medicine 2024;46(9):2972-2979
AIM To study the chemical constituents from the leaves of Citrus reticulata Blanco and their anti-inflammatory activities.METHODS The 85%ethanol extract from the leaves of C.reticulata was isolated and purified by silica gel,D101 macroporous resin,MCI,ODS and Sephadex LH-20,then the structures of obtained compounds were identified by physicochemical properties and spectral data.The Griess method was used to determine their inhibitory activities on lipopolysaccharide-induced NO production in macrophages RAW 264.7 cells.The mice foot swelling inflammation model induced by carrageenan was established,and the levels of IL-1β,TNF-α were detected.RESULTS Twelve compounds were isolated and identified as nobiletin(1),tangeretin(2),5-demethylinoblitin(3),5,4'-dihydroxy-6,7,8,3'-tetramethoxy flavone(4),5-hydroxy-7,8,3',4'-trimethoxyflavanone(5),3,5,6,7,8,3',4'-heptamethoxyflavanone(6),hesperetin(7),5-hydroxy-6,7,3',4'-tetramethoxyphenone(8),β-balsam alcohol(9),stigmaster-5-en-3β-alcohol(10),p-hydroxybenzaldehyde(11),vanillin(12).Compounds 1,4,6,7,10 and 12 had strong inhibitory activites on NO release in LPS-induced RAW 264.7 cells,and the IC50 values were(25.21±2.10),(37.77±0.50),(38.19±1.58),(21.89±1.73),(43.81±1.18),(47.98±2.55),(41.23±1.11),(43.80±1.43)μmol/mL,respectively.Compounds 2-3 reduced IL-1β and TNF-α levels(P<0.05,P<0.01).CONCLUSION Compounds 6-7,9 are isolated from this plant for the first time.Compounds 1-4,8 exhibit strong in vitro anti-inflammatory activities,and compounds 2-3 exhibit significant in vivo anti-inflammatory activities.
9. Structural distribution and mechanism of elastic fibers and collagen fibers in ventricular interstitium of aged rats
Ya-Ping XU ; Yue-Xin YU ; Ke-Ke WANG ; Zhi-Kun GUO ; Jin-Fu CHEN ; Zhi-Kun GUO
Acta Anatomica Sinica 2023;54(6):716-721
Objective To investigate the structural distribution features and mechanism of elastic fibers and collagen fibers in ventricular interstitium of aged rats. Methods Five young SD rats (24 weeks) and five old SD rats (104 weeks) were used,and their cardiac function was examined by echocardiography. Modified Weigert elastic fiber staining, immunohistochemistry, immunofluorescence and Western blotting techniques were used to detect the expression changes of type I and IH collagen fibers and their proteins, elastic fibers and their proteins, matrix metalloproteinase 2 (MMP-2), matrix metalloproteinase 9 (MMP-9) and tissue inhibitor of metalloproteinase 2 (TIMP-2), respectively. Results The type I and type IH collagen in the ventricular interstitium of aged rats was very sufficient and wrapped around the cardiomyocytes. Compared with the young rats, the content of collagen protein in the ventricular interstitium of the aged rats significantly increased (P<0. 05). Elastic fibers in the ventricular interstitium of the aged rats were and widely distributed. Compared with the young rats, the number of elastic fibers and the level of elastin in the ventricular interstitium of the aged rats significantly decreased (P<0. 05), and the expression levels of MMP-2 and MMP-9 in ventricular muscle of aged rats increased, and the)' were correlated with the level of elastin. The level of TIMP-2 in ventricular muscle of aged rats decreased with age. Conclusion The number of collagen fibers and elastic fibers in ventricular interstitium of aged rats is fluctuated with each other. With the increase of age, the contents of TIMP-2 and elastic fibers in the ventricular interstitium gradually decreased, and the ratio of collagen fibers to elastic fibers is out of balance.
10. Six body indexes and typing characteristics of Xibe adults
Guo-Chang XU ; Zhi-Guo CHEN ; Guo-Chang XU ; Zhi-Guo CHEN ; Ke-Lei GUO ; You-Feng WEN ; Dong JIANG
Acta Anatomica Sinica 2023;54(4):477-483
[Abstract] Objective To explore the body index and typing characteristics of Xibe nationality. Methods According to Anthropomatric Methods, height, chest circumference, sitting height, shoulder width, pelvic width and body mass morphological indexes were collected from 588 Xibe people in Yili area and 420 Xibe people over 18 years old in Shenyang area. After data collation, body index and typing were calculated and analyzed statistically. Results Except for Xibe male stature-shoulder breadth index and Caup’ s index in Yili area and female stature-shoulder breadth index in Shenyang area, there were differences among age groups in other indexes (P < 0. 05). Except for male stature-chest circumference index, stature-crista iliaca index, female stature-chest circumference index, stature-sitting height index, Manouvrier’s skelic index, there were differences among regions (P<0. 05). The adult body shape of Xibe nationality was mainly of wide chest, wide shoulder, long trunk, wide pelvis, medium leg and sub-long leg (male), sub-short leg and medium leg (female), and overweight. Conclusion There are regional and age differences in the body index and typing of Xibe adults. Compared with other ethnic minorities, Xibe nationality’s stature-chest circumference index, stature-shoulder breadth index, stature-crista iliaca index, Caup’s index are at a higher level. The proportion of legs and body of Xibe nationality is in the middle level, while the proportion of trunk is slightly shorter for men and slightly longer for women.

Result Analysis
Print
Save
E-mail