1.Effect of VEGF on the expression of genes related to ovarian steroid synthesis in mice and its mechanism
Zhi-Hui ZHANG ; Hong-Xia GAO ; Guo-Qing WANG ; Wei HOU ; Chang ZOU ; Xiao-Dan LU
Medical Journal of Chinese People's Liberation Army 2024;49(6):679-685
Objective To investigate the effect of vascular endothelial growth factor(VEGF)on the expression of genes related to ovarian steroid synthesis in mice and its underlying mechanism.Methods A transgenic mouse model with tetracycline-reversible regulation of VEGF expression was used,and the genotype of mice was identified by polymerase chain reaction(PCR).Twenty mice were divided into normal VEGF expression group(Dox+,n=10)and VEGF expression inhibition group(Dox-,n=10)by feeding them doxycycline.Western blotting was used to detect the expression of VEGF protein in ovarian tissues.Fluorescence quantitative PCR was used to detect the mRNA expression of VEGF,KDR and genes known to play roles in follicle development,such as follicle-stimulating hormone(FSH)and inhibin B(INHBB).HE staining was used to observe changes in ovarian tissue.Total RNA was extracted from mouse ovarian tissues for transcriptome sequencing,and the relevant differential genes were analyzed by FPKM and log2FC values.Results Compared with the Dox+group,the mRNA and protein levels of VEGF in the Dox-group significantly reduced,and the mRNA levels of KDR also significantly decreased(P<0.05).HE staining results showed that compared with the Dox+group,follicular development was impaired and atresia follicles appeared in the Dox-group.Sequencing analysis identified that significant differences in follicular development-related genes and steroid synthesis-related genes between the two groups(P<0.05).Enrichment analysis showed that VEGF in mouse ovaries mainly regulates ovarian steroidogenesis and other pathways.Fluorescence quantitative PCR results demonstrated that compared with the Dox+group,the follicular development-related genes(INHBB and FSHR)in the ovarian tissues of the Dox-group were significantly up-regulated(P<0.05),whereas the key genes of steroid synthesis(StAR,CYP11A1,3β-HSD)were significantly down-regulated(P<0.05).The quantitative results were basically consistent with the sequencing results.Conclusion Mice with inhibited VEGF exhibited ovarian follicular dysplasia,potentially due to the mechanism whereby VEGF inhibition downregulated the expression of genes associated with steroid synthesis,such as FSH and INHBB,thereby obstructing cholesterol metabolism.
2.Roles of intestinal mucosa,intestinal immunity and microbiota in entero-genic Candida albicans infection
Hui-Ting CHEN ; Jia-Sheng LI ; Zhi-Chang XU ; Ding-Mei QIN ; Yi ZHANG ; Rui-Rui WANG
Chinese Journal of Infection Control 2024;23(5):631-637
Enterogenic Candida albicans(C.albicans)infection refers to the translocation of intestinal colonized C.albicans under certain conditions,breaking through the intestinal tract,causing tissue infection or even invasive C.albicans infection.As the first contact point of Candida,the intestinal mucosa is the first line defending coloni-zation or invasion of C.albicans,often inhibiting infection by physical barrier and activating host immunity.As an-other defense mechanism,the intestinal microbiota jointly resists the invasive infection of C.albican through regula-ting pH,secreting antimicrobial peptides,and competing for adhesion points.This review summarizes the roles of three key factors,namely intestinal mucosa,intestinal immunity and microbiota,in enterogenic C.albicans infec-tion,providing new ideas for scientific research on invasive candidiasis caused by intestinal colonization.
3.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
4.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
5.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
6.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
7.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
8.Performance of screening of contacts of COVID-19 cases in same flight.
Dan LI ; Ying QIN ; Si Meng FAN ; Zhi Bin PENG ; Hui GE ; Zhao Rui CHANG ; Rui ZHANG ; Xiao Kun YANG ; Hong Ting ZHAO ; Jian Dong ZHENG ; Shi Cheng YU ; Hui WANG ; Jun YAN ; Zhong Jie LI
Chinese Journal of Epidemiology 2023;44(5):713-719
Objective: To understand the performance of 2019-nCoV nucleic acid detection in screening of contacts of COVID-19 cases in same flights and provide evidence for the effective screening of persons at high risk for the infection in domestic flights. Methods: The information of passengers who took same domestic flights with COVID-19 cases in China from April 1, 2020 to April 30, 2022 were retrospectively collected,and χ2 test was used to analyze positive nucleic acid detection rates in the passengers in different times before the onsets of the index cases, in different seat rows and in epidemic periods of different 2019-nCoV variants. Results: During the study period, a total of 433 index cases were identified among 23 548 passengers in 370 flights. Subsequently, 72 positive cases of 2019-nCoV nucleic acid were detected in the passengers, in whom 57 were accompanying persons of the index cases. Further analysis of the another 15 passengers who tested positive for the nucleic acid showed that 86.67% of them had onsets or positive detections within 3 days after the diagnosis of the index cases, and the boarding times were all within 4 days before the onsets of the index cases. The positive detection rate in the passengers who seated in first three rows before and after the index cases was 0.15% (95%CI: 0.08%-0.27%), significantly higher than in the passengers in other rows (0.04%, 95%CI: 0.02%-0.10%, P=0.007),and there was no significant difference in the positive detection rate among the passengers in each of the 3 rows before and after the index cases (P=0.577). No significant differences were found in the positive detection rate in the passengers, except the accompanying persons, among the epidemics caused by different 2019-nCoV variants (P=0.565). During the Omicron epidemic period, all the positive detections in the passengers, except the accompanying persons, were within 3 days before the onset of the index cases. Conclusions: The screening test of 2019-nCoV nucleic acid can be conducted in the passengers took the same flights within 4 days before the onsets of the index cases on board. Passengers who seated within 3 rows from the index cases can considered as the close contacts at high risk for 2019-nCoV, for whom screening should be conducted first and special managements are needed. The passengers in other rows can be classified as general risk persons for screening and management.
Humans
;
COVID-19
;
Retrospective Studies
;
SARS-CoV-2
;
China
;
Nucleic Acids
9.Clinical analysis of inflatable video-assisted mediastinoscopic transhiatal esophagectomy combined with laparoscopy.
Zhi Ning HUANG ; Chang Qing LIU ; Ming Fa GUO ; Mei Qing XU ; Xiao Hui SUN ; Gao Xiang WANG ; Ming Ran XIE
Chinese Journal of Surgery 2023;61(1):48-53
Objective: To examine the safety and effectiveness of inflatable video-assisted mediastinoscopic transhiatal esophagectomy (IVMTE). Methods: Totally 269 patients admitted to the Anhui Provincial Hospital of Anhui Medical University who underwent IVMTE (IVMTE group, n=47) or thoracoscopy combined with minimally invasive Mckeown esophageal cancer resection (MIME group, n=222) from September 2017 to December 2021 were analyzed retrospectively. There were 31 males and 16 females in IVMTE group, aged (68.6±7.5) years (range: 54 to 87 years). There were 159 males and 63 females in MIME group, aged (66.8±8.8) years (range: 42 to 93 years). A 1∶1 match was performed on both groups by propensity score matching, with 38 cases in each group. The intraoperative conditions and postoperative complication rates of the two groups were compared by t test, Wilcoxon rank, χ2 test, or Fisher exact probability method. Results: Patients in IVMTE group had less intraoperative bleeding ((96.0±39.2) ml vs. (123.8±49.3) ml, t=-2.627, P=0.011), shorter operation time ((239.1±47.3) minutes vs. (264.2±57.2) minutes, t=-2.086, P=0.040), and less drainage 3 days after surgery (85(89) ml vs. 675(573) ml, Z=-7.575, P<0.01) compared with that of MIME group. There were no statistically significant differences between the two groups in terms of drainage tube-belt time, postoperative hospital stay, and lymph node dissection stations and numbers (all P>0.05). The incidence of Clavien-Dindo grade 1 to 2 pulmonary infection (7.9%(3/38) vs. 31.6%(12/38), χ²=6.728, P=0.009), total complications (21.1%(8/38) vs. 47.4%(18/38), χ²=5.846, P=0.016) and total lung complications (13.2%(5/38) vs. 42.1%(16/38), χ²=7.962, P=0.005) in the IVMTE group were significantly lower. Conclusion: Inflatable video-assisted mediastinoscopic transhiatal esophagectomy combined with laparoscopic esophagectomy is safe and feasible, which can reach the same range of oncology as thoracoscopic surgery.
Male
;
Female
;
Humans
;
Retrospective Studies
;
Esophagectomy/methods*
;
Treatment Outcome
;
Laparoscopy
;
Thoracoscopy
;
Lymph Node Excision/methods*
;
Esophageal Neoplasms/surgery*
;
Postoperative Complications
10.Application and value of intravascular ultrasound for excimer laser ablation combined with drug-coated balloon in the treatment of lower limb arteriosclerotic obliterans.
Guan Yu QIAO ; Xiao Lang JIANG ; Bin CHEN ; Jun Hao JIANG ; Tao MA ; Chang Po LIN ; Gang FANG ; Da Qiao GUO ; Xin XU ; Zhi Hui DONG ; Wei Guo FU
Chinese Journal of Surgery 2023;61(2):150-155
Objective: To examine the value of intravascular ultrasound (IVUS) for excimer laser ablation (ELA) combined with drug-coated balloon (DCB) in treating lower limb arteriosclerotic obliterans (ASO). Methods: As a prospective case series study, patients who underwent ELA combined with DCB for lower limb ASO with the guidance of IVUS from September 2021 to March 2022 at Department of Vascular Surgery, Zhongshan Hospital, Fudan University were enrolled prospectively. Lesion characteristics, procedure-related outcomes and complications were collected. The therapy outcomes were compared with baseline data by paired t test. Results: There were 8 males and 2 females, aged (72.0±5.9) years (range: 61 to 81 years). Of all the 11 lesions, there were 8 lesions in superficial femoral artery and 3 in popliteal artery. The lesion length was (7.0±2.4) cm (range: 3.2 to 9.8 cm). There were 4 chronic totally occlusion and 7 severe stenosis. All patients underwent the operation successfully. The technical success rate was 10/11. Bailout stenting was performed in one lesion because of flow-limiting dissection. Four lesions were grade 3 to 4 in peripheral artery calcium score system, and 9 lesions with calcification arc≥180°. Larger diameter drug-coated balloons were selected in 5 lesions after measurement of intravascular ultrasound. The follow-up time was (6.0±1.9) months (range: 3 to 9 months). The ankle-brachial index of the patient was significantly improved immediately after surgery (0.97±0.13 vs. 0.48±0.18, t=-7.60, P<0.01) and at 3 months after surgery (0.95±0.12 vs. 0.48±0.18, t=-7.17, P<0.01). The 3-month primary patency rate was 11/11, the target lesion reintervention was 0 and ulcer healing rate was 3/4. Conclusion: IVUS assisted ELA in the treatment of lower limb artery lesions is safe and effective in early stage.
Female
;
Male
;
Humans
;
Laser Therapy
;
Lower Extremity
;
Ultrasonography
;
Femoral Artery
;
Ultrasonography, Interventional

Result Analysis
Print
Save
E-mail