1.Four new sesquiterpenoids from the roots of Atractylodes macrocephala
Gang-gang ZHOU ; Jia-jia LIU ; Ji-qiong WANG ; Hui LIU ; Zhi-Hua LIAO ; Guo-wei WANG ; Min CHEN ; Fan-cheng MENG
Acta Pharmaceutica Sinica 2025;60(1):179-184
The chemical constituents in dried roots of
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Biomechanical difference of different fixation methods in bone healing of distal tibial comminuted fractures analyzed by finite element method
Huadong YAN ; Zhong ZHANG ; Gang ZHAO ; Jie LI ; Hua SONG ; Jianhua SUN ; Zhi LIU ; Mingming WANG
Chinese Journal of Tissue Engineering Research 2024;28(24):3814-3821
BACKGROUND:The treatment of distal tibial comminuted fractures with soft tissue injury has always been challenging.The new retrograde tibial nailing and supercutaneous locking plate are important treatment methods,but their strain and stress shielding at the fracture end during different periods of fracture healing and different load conditions have not been reported. OBJECTIVE:To explore the biomechanical stability of retrograde tibial nailing and supercutaneous locking plate in different periods of fracture healing by finite element analysis to offer a scientific foundation for clinical application and rehabilitation exercise. METHODS:The finite element model of distal tibial comminuted fracture was established by utilizing the CT data of the tibia from a 40-year-old healthy male.Retrograde tibial nailing,supercutaneous locking plate,and callus models were assembled in accordance with the principle of fracture fixation.The finite element analysis was performed using ANSYS software to compare the displacement of the fracture end,the stress shielding of the tibia,the stress of the callus,and the stress distribution of the tibia and the fixation device during different periods of fracture healing. RESULTS AND CONCLUSION:(1)The relative displacement of the tibial fracture decreased gradually with the healing of the fracture,and the displacement decreased significantly after 3 months.At 0 and 1 months after operation,the vertical displacement and total displacement of the supercutaneous locking plate group were higher than those in the retrograde intramedullary nail group.The Z-axis displacement(horizontal medial and lateral displacement)of the two fixation methods was more obvious than the X-axis and Y-axis,and the Z-axis displacement of supercutaneous locking plate group was the most obvious.The maximum Z-axis displacement of the two fixation methods was located on the outside of the tibia,and the minimum displacement was located on the inside of the tibia.(2)The stress shielding rate at different periods of fracture healing gradually decreased with time.The stress shielding rate of the retrograde intramedullary nail was higher than that of the supercutaneous locking plate at different stages of fracture healing.After 3 months,the stress shielding rate of the supercutaneous locking plate was reduced to about 4%,and the stress shielding rate of the retrograde intramedullary nail was reduced to about 40%.(3)The stress of the stress concentration site of the callus in the two fixation methods increased with the increase of the load,and the stress of the callus in the supercutaneous locking plate group was always greater than that in the retrograde intramedullary nail group.The maximum stress distribution of the callus was approximately equally distributed among the two modes of fixation,both in the lateral portion of the tibia.(4)As the fracture healed,the maximum stress of the tibia in the two groups decreased gradually,and the stress in the supercutaneous locking plate group was always greater than that in the retrograde intramedullary nail group.The average stress of the maximum stress area of the tibia in the supercutaneous locking plate group under 1 500 N load was 285 MPa,while that in the retrograde intramedullary nail group was 26 MPa.(5)As the fracture healed,the stress of the fixation device in the two groups decreased gradually,and the stress in the supercutaneous locking plate group was significantly higher than that in the retrograde intramedullary nail group.After 3 months,the stress of the two fixation devices decreased significantly.(6)It is indicated that in the early stage of fracture healing,the strain on the fracture end in the retrograde intramedullary nail group is small,and the maximum stress of the tibia is moderate,allowing early loaded.The fractured ends in the supercutaneous locking plate group had too large strain and too large maximum stress of the tibia,which needed to be partially loaded under protection and could not be fully loaded.In the middle and late stages of fracture healing,the tibial retrograde intramedullary nail and the supercutaneous locking plate could be completely loaded,and the stress shielding rate of the supercutaneous locking plate was significantly lower than the tibial retrograde intramedullary nail.
8.Construction and application of a mixed-reality distance teaching model in neurosurgery
Rui HUI ; Hulin ZHAO ; Gang CHENG ; Wei LIU ; Zhi WANG ; Jianning ZHANG
Chinese Journal of Medical Education Research 2024;23(3):428-432
Objective:To explore the application effects of a neurosurgical mixed-reality distance teaching (NMDT) model in standardized residency training in neurosurgery.Methods:We built an NMDT system using mixed-reality technology and remote interaction technology, and designed the implementation procedure according to the teaching objectives. After the teaching activities were completed, a teaching satisfaction questionnaire survey was conducted among 20 neurosurgery resident trainees, in which they provided satisfaction scores for the same teaching content with different teaching models (i.e., the NMDT model and traditional teaching model). SPSS 22.0 software was used to perform the t test for data analysis. Results:There were significant differences between the NMDT model and the traditional teaching model in key indicators including the score for "completion of teaching objectives" (9.20±0.68 vs. 8.25±0.70, P<0.001) and the score for "satisfaction with learning gains" score (8.95±0.67 vs. 8.05±0.92, P=0.001). The NMDT model also outperformed the traditional teaching model in the other individual scores and the total score. Conclusions:The NMDT model can improve teaching quality, increase training efficiency, and enrich teaching content, which is worthy of promotion.
9.A Case Report of Multidisciplinary Diagnosis and Treatment of a Patient with Tuberous Sclerosis Complex and Multi-Organ Involvement
Hua ZHENG ; Yunfei ZHI ; Lujing YING ; Lan ZHU ; Mingliang JI ; Ze LIANG ; Jiangshan WANG ; Haifeng SHI ; Weihong ZHANG ; Mengsu XIAO ; Yushi ZHANG ; Kaifeng XU ; Zhaohui LU ; Yaping LIU ; Ruiyi XU ; Huijuan ZHU ; Li WEN ; Yan ZHANG ; Gang CHEN ; Limeng CHEN
JOURNAL OF RARE DISEASES 2024;3(1):79-86
Tuberous sclerosis complex(TSC)is a rare genetic disease that can lead to benign dysplasia in multiple organs such as the skin, brain, eyes, oral cavity, heart, lungs, kidneys, liver, and bones. Its main symptoms include epilepsy, intellectual disabilities, skin depigmentation, and facial angiofibromas, whilst incidence is approximately 1 in 10 000 to 1 in 6000 newborns. This case presents a middle-aged woman who initially manifested with epilepsy and nodular depigmentation. Later, she developed a lower abdominal mass, elevated creatinine, and severe anemia. Based on clinical features and whole exome sequencing, the primary diagnosis was confirmed as TSC. Laboratory and imaging examinations revealed that the lower abdominal mass originated from the uterus. CT-guided biopsy pathology and surgical pathology suggested a combination of leiomyoma and abscess. With the involvement of multiple organs and various complications beyond the main diagnosis, the diagnostic and therapeutic process for this patient highlights the importance of rigorous clinical thinking and multidisciplinary collaboration in the diagnosis and treatment of rare and challenging diseases.
10.STM2457 Inhibits METTL3-Mediated m6A Modification of miR-30c to Alleviate Spinal Cord Injury by Inducing the ATG5-Mediated Autophagy
Gang CHEN ; Zhitao SHANGGUAN ; Xiaoqing YE ; Zhi CHEN ; Jiandong LI ; Wenge LIU
Neurospine 2024;21(3):925-941
Objective:
The study aimed to investigate the role of N6-methyladenosine (m6A) modification in spinal cord injury (SCI) and its underlying mechanism, focusing on the interplay between m6A methyltransferase-like 3 (METTL3), miR-30c, and autophagy-related proteins.
Methods:
An SCI model was established in rats, and changes in autophagy-related proteins, m6A methylation levels, and miR-30c levels were analyzed. Hydrogen peroxide (H2O2)-stimulated spinal cord neuron cells (SCNCs) were used to assess the impact of METTL3 overexpression. The effects of STM2457, an antagonist of METTL3, were evaluated on cell viability, apoptosis, and autophagy markers in H2O2-stimulated SCNCs.
Results:
In the SCI model, decreased levels of autophagy markers and increased m6A methylation, miR-30c levels, and METTL3 were observed. Overexpression of METTL3 in SCNCs led to reduced cell viability, increased apoptosis, and suppressed autophagy. Conversely, co-overexpression of autophagy-related protein 5 (ATG5) or miR-30c inhibition reversed these effects. Knocking out METTL3 yielded opposite results. STM2457 treatment improved cell viability, reduced apoptosis, and upregulated autophagy markers in SCNCs, which also enhanced functional recovery in rats as measured by the Basso-Beattie-Bresnahan score and inclined plate test.
Conclusion
STM2457 alleviated SCI by suppressing METTL3-mediated m6A modification of miR-30c, which in turn induces ATG5-mediated autophagy. This study provides insights into the role of m6A modification in SCI and suggests a potential therapeutic approach through targeting METTL3.

Result Analysis
Print
Save
E-mail