1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6. Effects of HMGB1 on phenotypes, phagocytosis and ERK/JNK/P38 MAPK signaling pathway in dendritic cells
Ying-Ying CHEN ; Zhi-Xiang MOU ; Xiao-Long HU ; Yi-Yan ZHANG ; Jiao-Qing WENG ; Tian-Jun GUAN ; Ying-Ying CHEN ; Lan CHEN ; Tian-Jun GUAN ; Lan CHEN ; Pei-Yu LYU
Chinese Pharmacological Bulletin 2024;40(2):248-255
Aim To explore the impacts of high mobility group box 1 (HMGB1) on the phenotypes, endocy-tosis and extracellular signal-regulated kinase (ERK)/ Jun N-terminal protein kinase (JNK)/P38 mitogen-ac-tivated protein kinase (MAPK) signaling pathway in indoxyl sulfate (IS) -induced dendritic cells (DCs). Methods After treatment with 30, 300 and 600 (xmol · L
7.A Rapid Non-invasive Method for Skin Tumor Tissue Early Detection Based on Bioimpedance Spectroscopy
Jun-Wen PENG ; Song-Pei HU ; Zhi-Yang HONG ; Li-Li WANG ; Kai LIU ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2024;51(5):1161-1173
ObjectiveIn recent years, with the intensification of environmental issues and the depletion of ozone layer, incidence of skin tumors has also significantly increased, becoming one of the major threats to people’s lives and health. However, due to factors such as high concealment in the early stage of skin tumors, unclear symptoms, and large human skin area, most cases are detected in the middle to late stage. Early detection plays a crucial role in postoperative survival of skin tumors, which can significantly improve the treatment and survival rates of patients. We proposed a rapid non-invasive electrical impedance detection method for early screening of skin tumors based on bioimpedance spectroscopy (BIS) technology. MethodsFirstly, we have established a complete skin stratification model, including stratum corneum, epidermis, dermis, and subcutaneous tissue. And the numerical analysis method was used to investigate the effect of dehydrated and dry skin stratum corneum on contact impedance in BIS measurement. Secondly, differentiation effect of different diameter skin tumor tissues was studied using a skin model after removing the stratum corneum. Then, in order to demonstrate that BIS technology can be used for detecting the microinvasion stage of skin tumors, we conducted a simulation study on the differentiation effect of skin tumors under different infiltration depths. Finally, in order to verify that the designed BIS detection system can distinguish between tumor microinvasion periods, we conducted tumor invasion experiments using hydrogel treated pig skin tissue. ResultsThe simulation results show that a dry and high impedance stratum corneum will bring about huge contact impedance, which will lead to larger measurement errors and affect the accuracy of measurement results. We extracted the core evaluation parameter of relaxed imaginary impedance (Zimag-relax) from the simulation results of the skin tumor model. When the tumor radius (Rtumor) and invasion depth (h)>1.5 mm, the designed BIS detection system can distinguish between tumor tissue and normal tissue. At the same time, in order to evaluate the degree of canceration in skin tissue, the degree of tissue lesion (εworse) is defined by the relaxed imaginary impedance (Zimag-relax) of normal and tumor tissue (εworse is the percentage change in virtual impedance of tumor tissue relative to that of normal tissue), and we fitted a Depth-Zimag-relax curve using relaxation imaginary impedance data at different infiltration depths, which can be applied to quickly determine the infiltration depth of skin tumors after being supplemented with a large amount of clinical data in the future. The experimental results proved that when εworse=0.492 0, BIS could identify microinvasive tumor tissue, and the fitting curve correction coefficient of determination was 0.946 8, with good fitting effect. The simulation using pig skin tissue correlated the results of real human skin simulation with the experimental results of pig skin tissue, proving the reliability of this study, and laying the foundation for further clinical research in the future. ConclusionOur proposed BIS method has the advantages of fast, real-time, and non-invasive detection, as well as high sensitivity to skin tumors, which can be identified during the stage of tumor microinvasion.
8.Effect and mechanism of Jichuan decoction on intestinal function in rats model of slow transit constipation
Gui-Bing PEI ; Bo ZHANG ; Zhi-Cheng CHEN ; Hua JIANG
The Chinese Journal of Clinical Pharmacology 2024;40(8):1189-1193
Objective To investigate the effect of Jichuan decoction on defecation in rats with slow transit constipation(STC).Methods A total of 36 SD rats were divided into model group,experimental group and control group.Except the control group,STC rat models were established in the other two groups by gavage of 2%rhein acid suspension.The experimental group was given 170%Jichuan decoction of 10 mL·kg-1 by gavage,while the control group and model group were given with 0.9%NaCl by gavage,once a day for 30 days.Fecal dry-wet weight ratio and colon transport time were observed by fecal weighing and recording of first fecal discharge time;substance P(SP)and vasoactive peptide(VIP)contents in plasma were detected by kit;changes in intestinal flora were detected by real-time fluorescent quantitative polymerase chain reaction(qRT-PCR).Results The dry-wet ratio of feces in control group,model group and experimental group were(44.86±4.40)%,(53.44±3.52)%and(44.28±4.33)%,respectively;the colon transport time were(340.17±34.91),(424.67±37.26)and(377.36±38.87)min,respectively;plasma SP were(79.86±7.56),(60.30±2.41)and(78.84±5.83)pg·mL-1,respectively;plasma VIP were(30.56±2.87),(23.38±6.62)and(28.39±2.37)pg·mL-1,respectively;the numbers of Bifidobacterium were 7.77±0.04,5.19±0.09 and 7.45±0.03,respectively;the numbers of Lactobacillus were 6.40±0.07,4.10±0.05 and 6.36±0.08,respectively.There were statistically significant differences in the above indexes between model group and control group,and between experimental group and model group(P<0.01,P<0.05).Conclusion Jichuan decoction can improve the defecation of rats with slow transit constipation.
9.Efficacy of roxallistat combined with polysaccharide iron complex and Shengxuening in the treatment of maintenance hemodialysis renal anemia with poor recombinant human erythropoietin
Rui-Feng CHEN ; Pei YU ; Zhi-Ting WANG ; Yan LI ; Rui-Xian ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(12):1704-1708
Objective To investigate the efficacy of roxallistat combined with polysaccharide iron complex and Shengxuening in the treatment of maintenance hemodialysis renal anemia with poor recombinant human erythropoiesis.Methods Maintenance hemodialysis renal anemia patients with poor recombinant human erythropoietin effect were divided into control group and treatment group according to random number table method.The control group took roxallistat orally with a body weight of>60 kg,120 mg each time,3 times a week,and 45-60 kg with 100 mg each time,3 times a week;oral polysaccharide iron complex,300 mg each time,once a day.The treatment group was given Shengxuening orally based on the control group,0.25-0.50 g each time,3 times a day.Both groups were treated for 3 months.The clinical efficacy,inflammatory factors,iron metabolism,renal function,anemia index,traditional Chinese medicine symptom score and adverse drug reaction were compared between the two groups.Results In the control group,34 cases were enrolled,1 case fell off,and finally 33 cases were included in the analysis.In the treatment group,35 cases were enrolled,1 case was shed,and 34 cases were finally included in the analysis.After treatment,the total effective rate of treatment group and control group was 97.06%(33 cases/34 cases)and 81.82%(27 cases/33 cases),respectively,and the difference was statistically significant(P<0.05).After treatment,the nuclear transcription factor kappa B(NK-κB)in treatment group and control group were(24.09±3.06)and(35.23±4.11)ng·L-1;interferon gamma(IFN-γ)were(41.39±4.13)and(50.10±5.27)ng·L-1;transferrin saturation(TAST)were(38.62±5.91)%and(31.16±4.73)%;serum ferritin(SF)were(28.13±5.77)and(22.47±4.65)μmol·L-1;serum iron(SI)were(15.66±3.76)and(13.19±2.94)μmol·L-1;urinary protein excretion rate(24 h UPE)were(1.85±0.41)and(2.91±0.62)g·24 h-1;blood urea nitrogen(BUN)were(5.16±0.67)and(6.89±0.97)mmol·L-1;hemoglobin(Hb)were(91.38±11.23)and(83.19±8.54)g·L-1;hematocrit(Hct)were(29.01±7.40)%and(24.56±5.69)%;main disease score were(5.29±1.05)and(7.15±1.53)scores;the secondary scores were(3.11±0.46)and(4.98±0.77)scores;the total scores were(8.40±1.49)and(12.13±2.30)scores,with statistical significance(all P<0.05).The total incidence of adverse drug reactions in treatment group and control group were 14.71%and 9.09%,with no statistical significance(P>0.05).Conclusion Roxallistat combined with polysaccharide and iron complex and Shengxuening have good therapeutic effect in the treatment of maintenance hemodialysis renal anemia with poor recombinant human erythropoietin effect;it can reduce inflammation,regulate iron metabolism,improve renal function,and reduce adverse drug reactions.
10.Application of the OmniLogTM microbial identification system in the detection of the host spectrum for wild-type plague phage in Qinghai Plateau
Cun-Xiang LI ; Zhi-Zhen QI ; Qing-Wen ZHANG ; Hai-Hong ZHAO ; Long MA ; Pei-Song YOU ; Jian-Guo YANG ; Hai-Sheng WU ; Jian-Ping FENG
Chinese Journal of Zoonoses 2024;40(1):21-25
The growth of three plague phages from Qinghai Plateau in two Yersinia pestis strains(plague vaccine strains EV76 and 614F)and four non-Yersinia pestis strains(Yersinia pseudotuberculosis PTB3,PTB5,Escherichia coli V517,and Yersinia enterocolitica 52302-2)were detected through a micromethod based on the OmniLogTM microbial identification system and by the drop method,to provide a scientific basis for future ecological studies and classification based on the host range.For plague vaccine strains EV76 and 614F,successful phage infection and subsequent phage growth were observed in the host bacte-rium.Diminished bacterial growth and respiration and a concomitant decrease in color were observed with the OmniLogTM mi-crobial identification system at 33 ℃ for 48 h.Yersinia pseudotuberculosis PTB5 was sensitive to Yersinia pestis phage 476,but Yersinia pseudotuberculosis PST5 was insensitive to phage 087 and 072204.Three strains of non-Yersinia pestis(Yersinia pseudotuberculosis PTB3,Escherichia coli V517,and Yersinia enterocolitica 52302-2)were insensitive to Yersinia pestis pha-ges 087,072204,and 476 showed similar growth curves.The growth of phages 476 and 087,as determined with the drop method,in two Yersinia pestis strains(plague vaccine strains EV76 and 614F)and four non-Yersinia pestis strains(Yersinia pseudotuberculosis PTB3,Escherichia coli V517,and Yersin-ia enterocolitica 52302-2)showed the same results at 37 ℃,on the basis of comparisons with the OmniLogTM microbial i-dentification system;in contrast,phages 072204 did not show plaques on solid medium at 37 ℃ with plague vaccine strains EV76 and 614F.Determination based on the OmniLogTM detection system can be used as an alternative to the traditional determination of the host range,thus providing favorable application val-ue for determining the interaction between the phage and host bacteria.

Result Analysis
Print
Save
E-mail