1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Real-time Analysis of Organic Composition of Oral and Nasal Breath Air by High Resolution Mass Spectrometry
Kang-Yi WANG ; Chen TAO ; Xin LUO ; Zhi-Feng TANG ; Te BAI ; Hang LI ; Li-Gang HU ; Wei ZHANG ; Xue LI
Chinese Journal of Analytical Chemistry 2024;52(1):72-79,中插14-中插37
Human exhaled breath has great application prospects,e.g.,monitoring pharmacokinetics,disease diagnosis,due to its advantages such as non-invasive and high-frequency sampling.Breath samples can be collected from the oral and nasal cavity.However,the oral and nasal environment affect the chemical composition of breath sample.Therefore,the investigation on the chemical composition of mouth-exhaled breath and nose-exhaled breath is crucial for selection of appropriate sampling strategy for individual studies.In this work,secondary electrospray ionization-high resolution mass spectrometry(SESI-HRMS)was applied to analysis of respiratory metabolomics in real time.A quantitative analysis approach was established for 9 kinds of volatile organic compounds(VOCs)e.g.2-butanone,2-pentanone,ethyl acetate,methyl methacrylate,toluene,styrene,mesitylene,isoprene and limonene.The limit of detection was 2.3?240.8 ng/m3.The intra-day(n=6)and inter-day(n=18)relative standard deviations were 0.6%?4.6%and 4.3%?12.2%,respectively.Nine healthy subjects were recruited to investigate the chemical composition of mouth-exhaled and nose-exhaled breath.The results showed the good performance in quantitative analysis of 9 VOCs in breath air.It was found that the number of unique component(m/z)detected in mouth-exhaled breath(167)was 2.2 times greater than that detected in nose-exhaled breath(76),which might result from the complex environment in oral cavity.The signal intensity of commun component(163)was significantly different between mouth-exhaled breath and nose-exhaled breath.Additionally,the elemental composition analysis showed that the proportion of polar compounds detected in nose-exhaled breath was higher than that in mouth-exhaled breath.This study demonstrated that there was significant differences in the chemical composition between mouth-exhaled and nose-exhaled breath,which provided a theoretical basis for selection of exhalation mode.
7.Characteristics of abnormal coronary aorta origin in adults and cause analysis of missed diagnosis by transthoracic echocardiography
Si-Yang ZUO ; Sen LI ; You-Xiang KANG ; Xiao-Ling ZHAO ; Li-Xing WANG ; Rui CHEN ; Zhi-Yu FENG
Chinese Medical Equipment Journal 2024;45(1):71-75
Objective To analyze the characteristics of adult anomalous aortic origin of coronary artery(AAOCA)and the causes of missed diagnosis by transthoracic echocardiography(TTE)so as to facilitate TTE in diagnosing adult AAOCA.Methods A total of 37 adult patients with AAOCA diagnosed by non-invasive coronary CT angiography(CCTA)and/or invasive coronary angiography(ICA)were selected as research samples at some hospital from January 2019 to December 2022,and their clinical symptoms and the findings of 12-lead electrocardiogram,cardiac enzymes and TTE were summarized;the patients were typed according to the site of origin of coronary artery anomalies,and the causes for the missed diagnosis of TTE were eplored.Chi-square test was used to compare the differences in TTE missed diagnoses.Results Of the 37 patients,31 ones had no or only mild symptoms;most ones had negative results in terms of 12-lead electrocardiography,cardiac enzymes,changes in the size of the cardiac chambers,segmental ventricular wall motion abnormalities and left ventricular systolic function.The patients with anomalous origin of the right coronary artery from left sinus(ARCA-L)gained the largest proportion of 59.45%(22/37);21 patients were diagnosed with anomalous origin of coronary artery arising from the opposite sinus(ACAOS)in the two examinations of TTE,of whom there were 19 cases of ARCA-L,and the detection rate of ACAOS by TTE was 87.5%;all the 13 patients origins in branches and high-grade openings were missed by TTE.The detection rate of ACAOS by TTE was significantly higher than that of coronary artery anomalies originating in branches and in high openings,and the difference was statistically significant(21/24 vs 0/13,P<0.001).Conclusion Most adult AAOCA patients lack specificity in symptoms and related examination results.TTE has a high detection rate of ACAOS,while it is easy to miss the diagnosis of coronary artery anomalies originating from branches and high openings.Ultrasonographers have to identify false negative AAOCA by multi-section and multi-angle scanning and color Doppler flow imaging in order to reduce the rate of missed diagnosis.[Chinese Medical Equipment Journal,2024,45(1):71-75]
8.The Effect of Mitochondrial Damage in Chondrocytes on Osteoarthritis
Zhen-Wei LI ; Jing-Yu HOU ; Yu-Ze LIN ; Zhi-Qi ZHANG ; Shang-Yi LIU ; Xiao-Wen LIU ; Kang-Quan SHOU
Progress in Biochemistry and Biophysics 2024;51(7):1576-1588
The pathogenesis of osteoarthritis (OA) is related to a variety of factors such as mechanical overload, metabolic dysfunction, aging, etc., and is a group of total joint diseases characterized by intra-articular chondrocyte apoptosis, cartilage fibrillations, synovial inflammation, and osteophyte formation. At present, the treatment methods for osteoarthritis include glucosamine, non-steroidal anti-inflammatory drugs, intra-articular injection of sodium hyaluronate, etc., which are difficult to take effect in a short period of time and require long-term treatment, so the patients struggle to adhere to doctor’s advice. Some methods can only provide temporary relief without chondrocyte protection, and some even increase the risk of cardiovascular disease and gastrointestinal disease. In the advanced stages of OA, patients often have to undergo joint replacement surgery due to pain and joint dysfunction. Mitochondrial dysfunction plays an important role in the development of OA. It is possible to improve mitochondrial biogenesis, quality control, autophagy balance, and oxidative stress levels, thereby exerting a protective effect on chondrocytes in OA. Therefore, compared to traditional treatments, improving mitochondrial function may be a potential treatment for OA. Here, we collected relevant literature on mitochondrial research in OA in recent years, summarized the potential pathogenic factors that affect the development of OA through mitochondrial pathways, and elaborated on relevant treatment methods, in order to provide new diagnostic and therapeutic ideas for the research field of osteoarthritis.
9.Epimedin B exhibits pigmentation by increasing tyrosinase family proteins expression,activity,and stability
Chen HONG ; Yifan ZHANG ; Lili YANG ; Haoyang XU ; Kang CHENG ; Zhi LV ; Kaixian CHEN ; Yiming LI ; Huali WU
Journal of Pharmaceutical Analysis 2024;14(1):69-85
Epimedin B(EB)is one of the main flavonoid ingredients present in Epimedium brevicornum Maxim.,a traditional herb widely used in China.Our previous study showed that EB was a stronger inducer of melanogenesis and an activator of tyrosinase(TYR).However,the role of EB in melanogenesis and the mechanism underlying the regulation remain unclear.Herein,as an extension to our previous investi-gation,we provide comprehensive evidence of EB-induced pigmentation in vivo and in vitro and eluci-date the melanogenesis mechanism by assessing its effects on the TYR family of proteins(TYRs)in terms of expression,activity,and stability.The results showed that EB increased TYRs expression through microphthalmia-associated transcription factor-mediated p-Akt(referred to as protein kinase B(PKB))/glycogen synthase kinase 3β(GSK3β)/β-catenin,p-p70 S6 kinase cascades,and protein 38(p38)/mitogen-activated protein(MAP)kinase(MAPK)and extracellular regulated protein kinases(ERK)/MAPK pathways,after which EB increased the number of melanosomes and promoted their maturation for melanogenesis in melanoma cells and human primary melanocytes/skin tissues.Furthermore,EB exerted repigmentation by stimulating TYR activity in hydroquinone-and N-phenylthiourea-induced TYR inhibitive models,including melanoma cells,zebrafish,and mice.Finally,EB ameliorated monobenzone-induced depigmentation in vitro and in vivo through the enhancement of TYRs stability by inhibiting TYR misfolding,TYR-related protein 1 formation,and retention in the endoplasmic reticulum and then by downregulating the ubiquitination and proteolysis processes.These data conclude that EB can target TYRs and alter their expression,activity,and stability,thus stimulating their pigmentation function,which might provide a novel rational strategy for hypopigmentation treatment in the pharmaceutical and cosmetic industries.
10.Advances in crystal nucleation for amorphous drugs
Jie ZHANG ; Kang LI ; Zi-qing YANG ; Zi-han DING ; Sai-jun XIAO ; Zhi-ming YUE ; Li-mei CAI ; Jia-wen LI ; Ding KUANG ; Min-zhuo LIU ; Zhi-hong ZENG
Acta Pharmaceutica Sinica 2024;59(7):1962-1969
Amorphous solid dispersion (ASD) is one of the most effective formulation approaches to enhance the water solubility and oral bioavailability of poorly water-soluble drugs. However, maintenance of physical stability of amorphous drug is one of the main challenges in the development of ASD. Crystallization is a process of nucleation and crystal growth. The nucleation is the key factor that influences the physical stability of the ASD. However, a theoretical framework to describe the way to inhibit the nucleation of amorphous drug is not yet available. We reviewed the methods and theories of nucleation for amorphous drug. Meanwhile, we also summarized the research progress on the mechanism of additives influence on nucleation and environmental factors on nucleation. This review aims to enhance the better understanding mechanism of nucleation of amorphous drug and controlling over the crystal nucleation during the ASD formulation development.

Result Analysis
Print
Save
E-mail