1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.A Case Report of Multidisciplinary Diagnosis and Treatment of a Patient with Tuberous Sclerosis Complex and Multi-Organ Involvement
Hua ZHENG ; Yunfei ZHI ; Lujing YING ; Lan ZHU ; Mingliang JI ; Ze LIANG ; Jiangshan WANG ; Haifeng SHI ; Weihong ZHANG ; Mengsu XIAO ; Yushi ZHANG ; Kaifeng XU ; Zhaohui LU ; Yaping LIU ; Ruiyi XU ; Huijuan ZHU ; Li WEN ; Yan ZHANG ; Gang CHEN ; Limeng CHEN
JOURNAL OF RARE DISEASES 2024;3(1):79-86
Tuberous sclerosis complex(TSC)is a rare genetic disease that can lead to benign dysplasia in multiple organs such as the skin, brain, eyes, oral cavity, heart, lungs, kidneys, liver, and bones. Its main symptoms include epilepsy, intellectual disabilities, skin depigmentation, and facial angiofibromas, whilst incidence is approximately 1 in 10 000 to 1 in 6000 newborns. This case presents a middle-aged woman who initially manifested with epilepsy and nodular depigmentation. Later, she developed a lower abdominal mass, elevated creatinine, and severe anemia. Based on clinical features and whole exome sequencing, the primary diagnosis was confirmed as TSC. Laboratory and imaging examinations revealed that the lower abdominal mass originated from the uterus. CT-guided biopsy pathology and surgical pathology suggested a combination of leiomyoma and abscess. With the involvement of multiple organs and various complications beyond the main diagnosis, the diagnostic and therapeutic process for this patient highlights the importance of rigorous clinical thinking and multidisciplinary collaboration in the diagnosis and treatment of rare and challenging diseases.
7.Application of China-made Toumai? Robot in laparoscopic radical prostatectomy
Zhi-Feng WEI ; Yu-Hao CHEN ; Ze-Peng ZHU ; Qi JIANG ; Yu XIONG ; Feng-Feng LU ; Zhen-Qian SONG ; Bin JIANG ; Xiao-Feng ZHU ; Tian-Hao FENG ; Xiao-Feng XU ; Gang YANG ; Wu WEI ; Ai-Bing YAO ; Jing-Ping GE
National Journal of Andrology 2024;30(8):696-700
Objective:To evaluate the safety and efficiency of China-made Toumai Robot-assisted laparoscopic radical prosta-tectomy(LRP).Methods:This study included 40 cases of PCa treated from January 2023 to May 2023 by robot-assisted LRP with preservation of the bladder neck and maximal functional urethral length,15 cases with the assistance of Toumai Robot(the TMR group)and the other 25 with the assistance of da Vinci Robot as controls(the DVR group).We recorded the docking time,laparo-scopic surgery time,vesico-urethral anastomosis time,intraoperative blood loss and postoperative urinary continence,and compared them between the two groups.Results:Operations were successfully completed in all the cases.No statistically significant differ-ences were observed between the TMR and DVR groups in the docking time(6 min vs 5 min,P>0.05)or intraoperative blood loss(200 ml vs 150 ml,P>0.05).The TMR group,compared with the DVR group,showed a significantly longer median laparoscopic surgery time(146 min vs 130 min,P<0.05)and median vesico-urethral anastomosis time(19 min vs 16 min,P<0.05).There were no statistically significant differences between the TMR and DVR groups in the rates of urinary continence recovery immediately af-ter surgery(60.0%[9/15]vs 64.0%[16/25],P>0.05)or at 1 month(80.0%[12/15])vs(76.0%[19/25],P>0.05),3 months(93.3%[14/15])vs(92.0%[23/25],P>0.05)and 6 months postoperatively(100%[15/15])vs(96%[24/25],P>0.05).Conclusion:China-made Toumai? Robot surgical system is safe and reliable for laparoscopic radical prosta-tectomy,with satisfactory postoperative recovery of urinary continence.
8.Chemical constituents from the flower buds of Magnolia biondii and their in vitro acetylcholinesterase inhibitory activities
Yan-Gang CAO ; Jian-Chao WANG ; Meng-Na WANG ; Yu-Huan HE ; Hong-Wei LI ; Zhi-You HAO ; Xiao-Ke ZHENG ; Wei-Sheng FENG
Chinese Traditional Patent Medicine 2024;46(7):2278-2283
AIM To study the chemical constituents from flower buds of Magnolia biondii Pamp.and their in vitro acetylcholinesterase inhibitory activities.METHODS The 50% acetone extract from the flower buds of M.biondii was isolated and purified by Diaion HP-20,Toyopearl HW-40C,ODS and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.The in vitro acetylcholinesterase inhibitory activities of these compounds were determined according to previous method established by research group.RESULTS Seventeen compounds were isolated and identified as crassifolioside(1),magnoloside B(2),rutin(3),isoquercitrin(4),quercetin(5),northalifoline(6),cordysinin B(7),thymidine(8),indazole(9),dihydrodehydrodiconiferyl alcohol(10),aesculetin(11),C-veratroylglycol(12),3,4-dihydroxyphenylethanol(13),3-methoxy-4-hydroxyphenylethanol(14),3,4-dihydroxybenzoic acid(15),2,4,6-trimethoxyphenol(16),syringic acid(17).CONCLUSION Compounds 1-17 are isolated from this plant for the first time,none of which show acetylcholinesterase inhibitory activities at the concentration of 20 μmol/L.
9.Synthesis and characterization of matrix metalloproteinase-responsive BDNF controlled-release materials
Jun-Ru HEI ; Cui WANG ; Meng-Wen SONG ; Sheng-Qiang XIE ; Bing-Xian WANG ; Xiao-Juan LAN ; Han-Bo ZHANG ; Gang CHENG ; Zhi-Qiang LIU ; Xi-Qin YANG ; Jian-Ning ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(11):1319-1326
Objective To develop a matrix metalloproteinase(MMP)-responsive hyaluronic acid(HA)-based controlled-release material for brain-derived neurotrophic factor(BDNF)to provide a novel therapeutic strategy for intervention and repair of traumatic brain injury(TBI).Methods HA was modified with amination,followed by condensation with Suflo-SMCC carboxyl group to form amide,and then linked with glutathione(GSH)to synthesize HA-GSH.The recombinant glutathione S-transferase(GST)-tissue inhibitor of metalloproteinase(TIMP)-BDNF(GST-TIMP-BDNF)expression plasmid was constructed using molecular cloning technique with double enzyme digestion by Bam H Ⅰ and Eco R Ⅰ.The recombinant GST-TIMP-BDNF protein was expressed in the Escherichia coli prokaryotic expression system,and purified by ion exchange chromatography,confirmed by Western blotting.MMP diluents were supplemented with PBS,MMP inhibitor marimastat,and varing concentrations(0.4,0.6,0.8 mg/ml)of GST-TIMP-BDNF or GST-BDNF.MMP-2 activity was analyzed using an MMP activity detection kit to evaluate the inhibitory effect of the recombinant protein on MMP.Primary rat neurons were extracted and cultured to establish an iron death model induced by RSL3.The effect of recombinant protein GST-TIMP-BDNF on neuronal injury was detected by immunofluorescence staining.Results MRI hydrogen spectrum identification confirmed the successful synthesis of HA-GSH.Western blotting results showed the successful expression of the recombinant protein GST-TIMP-BDNF containing the GST tag using the E.coli prokaryotic expression system.MMP activity detection results indicated that the recombinant protein GST-TIMP-BDNF had a superior inhibitory effect on MMP-2 activity compared to GST-BDNF(P<0.05).Immunofluorescence staining results showed a significant increase in fluorescence intensity in rat neurons treated with GST-TIMP-BDNF after RSL3 induction(P<0.05).Conclusion A MMP-responsive HA-based BDNF controlled-release material has been successfully developed,exhibiting a protective effect on neuron damage.
10.IgA nephropathy with mesangial type Ⅲ collagen deposition:2 cases report
Jie-Bo HUANG ; Xiao-Fan CAI ; Zhong-Hua ZHAO ; Zhi-Gang ZHANG ; Qiang SHEN ; Hao WANG ; Hui-Juan WU
Fudan University Journal of Medical Sciences 2024;51(3):426-430
As interstitial collagen,type Ⅲ collagen(Col Ⅲ)does not express in normal glomeruli.However,in Col Ⅲ nephropathy,a large amount of Col Ⅲ deposit in the mesangial and subendothelial area of the glomeruli.IgA nephropathy with Col Ⅲ deposition was extremely rare.In this article,we reported two cases of such disease.After treating with immunosuppressive agents or traditional Chinese medicine decoction,the renal function of the two patients remained stable and the urinary protein levels reduced significantly.

Result Analysis
Print
Save
E-mail