1.Cross lag analysis of cumulative ecological risk and future orientation with health risk behaviors among higher vocational college students
ZENG Zhi, FU Gang, LI Ke, WANG Meifeng, WU Lian, ZHANG Tiancheng, ZHANG Fulan
Chinese Journal of School Health 2025;46(3):348-352
Objective:
To explore the causal link of cumulative ecological risk and future orientation with health risk behaviors among higher vocational college students, so as to provide reference for reducing and preventing health risk behaviors among higher vocational college students.
Methods:
A longitudinal follow up study was conducted on 612 students using convenience sampling from 2 vocational colleges in Hunan Province. The Cumulative Ecological Risk Scale, Future Orientation Scale, and Health Risk Behavior Scale were used during three follow up visits (T1: September 2022, T2: June 2023, T3: March 2024), and a cross lagged panel model was constructed to examine the longitudinal causal relationship of cumulative ecological risk, future orientation and health risk behaviors. Analysis of longitudinal intermediary effect between variables by Bootstrap.
Results:
The cumulative ecological risk scores of T1, T2 and T3 among higher vocational college students were (2.94±1.44,2.99±1.63,3.02±1.54), future orientation scores (40.49±4.71,41.51±5.72,41.06±4.35) and health risk behavior scores (3.73±2.01,3.49±2.00,3.23±2.00). The results of repeated measures ANOVA showed that the future orientation score of T2 was higher than that of T1, and the main effect of measurement time was statistically significant ( F=5.09,P<0.01,η 2=0.02). The health risk behavior score of T1 was higher than that of T2, and the health risk behavior score of T2 was higher than that of T3, and the main effect of measurement time was statistically significant ( F=10.12,P<0.01,η 2=0.03).The cross lagged model showed good adaptability, with χ 2/df =7.20 ( P <0.01), relative fitting indicators GFI=0.98, CFI=0.99, TLI=0.96, IFI=0.99, NFI =0.99, and absolute fitting indicator RMSEA =0.06. Among them, the T1, T2 cumulative ecological risk showed negatively predictive effects on T2, T3 future orientation ( β =-0.24, -0.47 ), and T1, T2 cumulative ecological risk positively predicted T2, T3 health risk behavior ( β =0.20, 0.24), while T1, T2 future orientation negatively predicted T2, T3 health risk behavior ( β =-0.25, -0.18) ( P <0.01). Bootstrap test analysis found that T2 future orientation had a longitudinal mediating effect ( β=0.04, P <0.01) on the T1 cumulative ecological risk and T3 health risk behavior.
Conclusions
The accumulation of ecological risk among higher vocational college students can positively predict health risk behaviors, while future orientation can negatively predict healthrisk behaviors. Moreover, future orientation plays a longitudinal mediating role between accumulated ecological risks and health risk behaviors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Determination of the Contents of Three Lignans in Dendrobium fimbriatum Hook
Ying-Hua HUANG ; Lin ZHANG ; Jin-Yan LI ; Zhi-Bin LI ; Zhi-Yun LIANG ; Li-E YANG ; Gang WEI ; Yue-Chun HUANG
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(1):207-212
Objective To establish the method for content determination of three lignans of Dendrobium Fimbriatum Hook..Methods The lignans in Dendrobium tasselii were identified by high-performance liquid chromatography/multi-stage mass spectrometry(HPLC-ESI/MSn)coupled with ultraviolet absorption spectrometry(UV)coupled with retention time localization of high-performance liquid chromatography(HPLC).The separation was carried out on a Kromasil 100-5 C18 column(4.6 mm×250 mm,5 μm)using a gradient elution of acetonitrile-0.1%formic acid solution as the mobile phase,the volume flow rate was 0.8 mL·min-1 and the column temperature was 35℃,and the mass spectrometry was performed using an ESI ion source with the data collected in the negative ion mode.The HPLC content was determined on the same column as that of MS analysis,with the mobile phase methanol + acetonitrile(V/V=1∶1)-0.01 mol/L ammonium acetate solution,gradient elution,flow rate of 0.8 mL·min-1,column temperature of 40℃,and detection wavelength of 215 nm.Results Syringaresinol di-O-glucoside and(-)-Syringaresinol 4-O-β-D-glucopyranoside and DL-Syringaresinol were identified from Dendrobium fimbriatum Hook.,and the results of content determination showed that the linear ranges of above three components were respectively 0.1701-3.4020,0.1020-2.0400,0.0403-0.8060 μg(r≥0.9995),the average recoveries were in the range of 97.71%-101.67%,and the relative standard deviations(RSDs)were all less than 3.0%.The contents of Syringaresinol di-O-glucoside and(-)-Syringaresinol 4-O-β-D-glucopyranoside and DL-Syringaresinol in the 10 batches of samples were 0.7779-1.3852,0.0734-0.1966,0.0295-0.1882 mg·g-1.Conclusion This research method can provide a reference basis for the quality evaluation method of Dendrobium fimbriatum Hook..
8.Application of droplet digital PCR in etiological diagnosis of severe acute pancreatitis patients with suspected bloodstream infection
Xin-Yu WANG ; Gang LI ; Wen-Jian MAO ; Jie YANG ; Jing-Zhu ZHANG ; Lu KE ; Wei-Qin LI ; Zhi-Hui TONG
Chinese Journal of Infection Control 2024;23(1):9-15
Objective To explore the value of droplet digital polymerase chain reaction(ddPCR)in the etiological diagnosis of severe acute pancreatitis(SAP)patients with suspected bloodstream infection(BSI).Methods SAP patients admitted to the department of critical care medicine in a hospital July to September 2022 were enrolled.When BSI was suspected,venous blood was collected for both ddPCR detection and blood culture(BC)with antimi-crobial susceptibility testing(AST)simultaneously.The time required for two detection methods was recorded,and the detection results of ddPCR and BC were compared.The etiological diagnostic efficacy of ddPCR was calculated,and the correlation between the value of pathogen load detected by ddPCR and the level of infection parameters was explored.Results A total of 22 patients were included in the analysis,and 52 venous blood specimens were collec-ted for detection.BC revealed 17 positive specimens(32.7%)and 29 pathogenic strains,while ddPCR showed 41 positive specimens(78.8%)and 73 pathogenic strains.Detection time required for ddPCR was significantly lower than that of BC([0.16±0.03]days vs[5.92±1.20]days,P<0.001).Within the detection range of ddPCR and taking BC results as the gold standard,the sensitivity and specificity of ddPCR were 80.0%and 28.6%,respective-ly.With the combined assessment of BSI based on non-blood specimen microbial evidence within a week,the sensi-tivity and specificity of ddPCR detection increased to 91.9%and 76.9%,respectively.ddPCR detected resistance genes of blaKPC,blaNDM/IMP,VanA/VanM,and mecA from 19,9,6,and 5 specimens,respectively.Correlation analysis showed a positive correlation between pathogen load and levels of C-reactive protein as well as procalcitonin(r=0.347,0.414,P<0.05).Conclusion As a supplementary detection method for BC in BSI diagnosis,ddPCR has the advantages of higher sensitivity and shorter detection time,and is worthy of further exploration in clinical application.
9.Real-time Analysis of Organic Composition of Oral and Nasal Breath Air by High Resolution Mass Spectrometry
Kang-Yi WANG ; Chen TAO ; Xin LUO ; Zhi-Feng TANG ; Te BAI ; Hang LI ; Li-Gang HU ; Wei ZHANG ; Xue LI
Chinese Journal of Analytical Chemistry 2024;52(1):72-79,中插14-中插37
Human exhaled breath has great application prospects,e.g.,monitoring pharmacokinetics,disease diagnosis,due to its advantages such as non-invasive and high-frequency sampling.Breath samples can be collected from the oral and nasal cavity.However,the oral and nasal environment affect the chemical composition of breath sample.Therefore,the investigation on the chemical composition of mouth-exhaled breath and nose-exhaled breath is crucial for selection of appropriate sampling strategy for individual studies.In this work,secondary electrospray ionization-high resolution mass spectrometry(SESI-HRMS)was applied to analysis of respiratory metabolomics in real time.A quantitative analysis approach was established for 9 kinds of volatile organic compounds(VOCs)e.g.2-butanone,2-pentanone,ethyl acetate,methyl methacrylate,toluene,styrene,mesitylene,isoprene and limonene.The limit of detection was 2.3?240.8 ng/m3.The intra-day(n=6)and inter-day(n=18)relative standard deviations were 0.6%?4.6%and 4.3%?12.2%,respectively.Nine healthy subjects were recruited to investigate the chemical composition of mouth-exhaled and nose-exhaled breath.The results showed the good performance in quantitative analysis of 9 VOCs in breath air.It was found that the number of unique component(m/z)detected in mouth-exhaled breath(167)was 2.2 times greater than that detected in nose-exhaled breath(76),which might result from the complex environment in oral cavity.The signal intensity of commun component(163)was significantly different between mouth-exhaled breath and nose-exhaled breath.Additionally,the elemental composition analysis showed that the proportion of polar compounds detected in nose-exhaled breath was higher than that in mouth-exhaled breath.This study demonstrated that there was significant differences in the chemical composition between mouth-exhaled and nose-exhaled breath,which provided a theoretical basis for selection of exhalation mode.
10.Biomechanical difference of different fixation methods in bone healing of distal tibial comminuted fractures analyzed by finite element method
Huadong YAN ; Zhong ZHANG ; Gang ZHAO ; Jie LI ; Hua SONG ; Jianhua SUN ; Zhi LIU ; Mingming WANG
Chinese Journal of Tissue Engineering Research 2024;28(24):3814-3821
BACKGROUND:The treatment of distal tibial comminuted fractures with soft tissue injury has always been challenging.The new retrograde tibial nailing and supercutaneous locking plate are important treatment methods,but their strain and stress shielding at the fracture end during different periods of fracture healing and different load conditions have not been reported. OBJECTIVE:To explore the biomechanical stability of retrograde tibial nailing and supercutaneous locking plate in different periods of fracture healing by finite element analysis to offer a scientific foundation for clinical application and rehabilitation exercise. METHODS:The finite element model of distal tibial comminuted fracture was established by utilizing the CT data of the tibia from a 40-year-old healthy male.Retrograde tibial nailing,supercutaneous locking plate,and callus models were assembled in accordance with the principle of fracture fixation.The finite element analysis was performed using ANSYS software to compare the displacement of the fracture end,the stress shielding of the tibia,the stress of the callus,and the stress distribution of the tibia and the fixation device during different periods of fracture healing. RESULTS AND CONCLUSION:(1)The relative displacement of the tibial fracture decreased gradually with the healing of the fracture,and the displacement decreased significantly after 3 months.At 0 and 1 months after operation,the vertical displacement and total displacement of the supercutaneous locking plate group were higher than those in the retrograde intramedullary nail group.The Z-axis displacement(horizontal medial and lateral displacement)of the two fixation methods was more obvious than the X-axis and Y-axis,and the Z-axis displacement of supercutaneous locking plate group was the most obvious.The maximum Z-axis displacement of the two fixation methods was located on the outside of the tibia,and the minimum displacement was located on the inside of the tibia.(2)The stress shielding rate at different periods of fracture healing gradually decreased with time.The stress shielding rate of the retrograde intramedullary nail was higher than that of the supercutaneous locking plate at different stages of fracture healing.After 3 months,the stress shielding rate of the supercutaneous locking plate was reduced to about 4%,and the stress shielding rate of the retrograde intramedullary nail was reduced to about 40%.(3)The stress of the stress concentration site of the callus in the two fixation methods increased with the increase of the load,and the stress of the callus in the supercutaneous locking plate group was always greater than that in the retrograde intramedullary nail group.The maximum stress distribution of the callus was approximately equally distributed among the two modes of fixation,both in the lateral portion of the tibia.(4)As the fracture healed,the maximum stress of the tibia in the two groups decreased gradually,and the stress in the supercutaneous locking plate group was always greater than that in the retrograde intramedullary nail group.The average stress of the maximum stress area of the tibia in the supercutaneous locking plate group under 1 500 N load was 285 MPa,while that in the retrograde intramedullary nail group was 26 MPa.(5)As the fracture healed,the stress of the fixation device in the two groups decreased gradually,and the stress in the supercutaneous locking plate group was significantly higher than that in the retrograde intramedullary nail group.After 3 months,the stress of the two fixation devices decreased significantly.(6)It is indicated that in the early stage of fracture healing,the strain on the fracture end in the retrograde intramedullary nail group is small,and the maximum stress of the tibia is moderate,allowing early loaded.The fractured ends in the supercutaneous locking plate group had too large strain and too large maximum stress of the tibia,which needed to be partially loaded under protection and could not be fully loaded.In the middle and late stages of fracture healing,the tibial retrograde intramedullary nail and the supercutaneous locking plate could be completely loaded,and the stress shielding rate of the supercutaneous locking plate was significantly lower than the tibial retrograde intramedullary nail.


Result Analysis
Print
Save
E-mail