1.External review of the recommendations of the Guidelines for Evidence-based Use of Biological Agents for the Clinical Treatment of Osteoporosis: a cross-sectional survey
Lingling YU ; Shuang LIU ; Zaiwei SONG ; Qiusha YI ; Yu ZHANG ; Liyan MIAO ; Zhenlin ZHANG ; Chunli SONG ; Yaolong CHEN ; Lingli ZHANG ; Rongsheng ZHAO
China Pharmacy 2025;36(9):1025-1029
OBJECTIVE To assess the scientific rigor, clarity and feasibility of the recommendations of the Guidelines for Evidence-based Use of Biological Agents for the Clinical Treatment of Osteoporosis (hereinafter referred to as the Guideline) through external review, in order to further revise and improve the Guideline recommendations. METHODS This study employed a cross-sectional survey research design, a convenience sampling method was adopted to select frontline medical workers in the field of osteoporosis (including clinical doctors, clinical pharmacists, and nurses) as well as patients or their family members. External review was conducted through a combination of closed-ended and open-ended electronic questionnaires to get feedback from them on the appreciation,clarity and feasibility of the 32 preliminary recommendations in the Guideline. RESULTS A total of 90 external review subjects from 15 hospitals were collected, including 45 clinical doctors, 15 clinical pharmacists, 15 nurses and 15 patients or their family members. The overall appreciation degree of recommendations was 99.38%, the overall clarity degree of recommendations was 98.92%, and the overall feasibility degree of recommendations was 99.65%. At the same time, 111 subjective suggestions were collected, which provided an important reference for the further improvement of the Guideline recommendations. Based on the above feedback, the Guideline steering committee and core expert group revised the wording of 12 draft recommendations without deletion, and finally determined 32 recommendations. CONCLUSIONS The external review provides an important basis for the final formation of the Guideline, further improves the scientific rigor, clarity and feasibility of the recommendations, and ensures the standardization, practicality and implementability of the Guideline.
2.Sputum metabolomics study in patients with occupational coal workers′ pneumoconiosis
Yiming ZHANG ; Qiufang QU ; Qingnan ZHOU ; Shuhan GUO ; Le LIU ; Yuke WANG ; Zhenlin HE ; Sanqiao YAO
China Occupational Medicine 2025;52(3):241-248
Objective To investigate the sputum metabolic profiles of patients with occupational coal workers' pneumoconiosis (CWP) by an untargeted metabolomics method, and to identify relevant differential metabolic pathways and potential biomarkers. Methods A total of 12 male patients with stage Ⅰ CWP were selected as the CWP group, and 16 healthy male individuals were selected as the control group, using a judgmental sampling method. Sputum metabolites of individuals in both groups were detected to perform non-targeted metabolomic analysis using the ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. Differential metabolites (DMs) and their pathways were screened using principal component analysis, partial least squares discriminant analysis, and Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analysis. Potential biomarkers were analyzed and identified via the receiver operating characteristic curve (ROC). Results There were apparent metabolic alterations observed in sputum of CWP patients compared with healthy controls. In the positive ion mode, a total of 42 DMs were identified in sputum from CWP patients, including 19 downregulated and 23 upregulated metabolites. In the negative ion mode, a total of 25 DMs were identified in sputum from CWP patients, including 16 downregulated and 9 upregulated metabolites. KEGG enrichment analysis of sputum from CWP patients showed that seven DMs pathways were enriched in ABC transporters, histidine metabolism, phenylalanine metabolism, arachidonic acid metabolism, linoleic acid metabolism, purine metabolism, and oxidative phosphorylation, involving 26 DMs. ROC analysis indicated that 16(R)-hydroxyarachidonic acid, pyrophosphate, and 2-hydroxyphenylacetate of these 26 DMs may serve as potential biomarkers for CWP. Conclusion Sputum metabolomic profiles were altered in CWP patients compared with healthy controls. The potential biomarkers of CWP prevention and treatment are 16(R)-hydroxyarachidonic acid, pyrophosphate, and 2-hydroxyphenylacetate.
3.A study on the consistency of myocardial extracellular volume quantification in the systole and diastole phases using dual-layer detector spectral CT
Zixuan LIU ; Yu ZHANG ; Yanjun LI ; Yong CHENG ; Tao SHUAI ; Ziwei WANG ; Zhenlin LI
Chinese Journal of Radiology 2024;58(2):165-171
Objective:To investigate the consistency of myocardial extracellular volume between systole and diastole using dual-layer detector spectral CT.Methods:This was a cross-sectional study. Thirty-five patients who underwent cardiac spectral CT examination in West China Hospital of Sichuan University from April 2022 to December 2022 were retrospectively collected. Hematocrit was collected within 3 days before the CT scan. The delayed phases holographic spectral images in systole (45%) and diastole (75%) were obtained using dual-layer spectral CT. CT data were processed using a spectral post-processing workstation, and the extracellular volume (ECV) based on iodine density images, referred as CT-ECV, in systolic and diastolic phases were calculated, respectively. According to the American Heart Association′s 16-segment model of left ventricular, the standard short-axis images were constructed, and the myocardium was standardized into 16 segments at the basal, mid-cavity, and apical levels of the left ventricle. Two radiologists performed a subjective evaluation in the image quality of the CT-ECV images of the whole heart and the three sections in systole and diastole using a "five-point" scale. The ECV of the 16 segments and the whole heart in systole and diastole was calculated. The consistency of subjective evaluations between systole and diastole was assessed using Kappa statistics. Wilcoxon signed-rank tests were used to compare the differences in scores between systole and diastole. Paired sample t-test was used to compare the differences in CT-ECV scores between systole and diastole. The intraclass correlation coefficient was used to test the intra-and inter-observer consistency of CT-ECV measurements between two radiologists. P<0.05 was statistically significant. Results:There was good agreement between the two radiologists on subjective scores of CT-ECV image quality between systole and diastole ( Kappa>0.80), and there was no statistical difference in image quality among the basal, mid-cavity, and apical levels of the left ventricle and whole heart between systole and diastole ( P>0.05). The systolic and diastolic CT-ECV for the entire heart obtained through the delay phase were (33.29±3.46)% and (33.50±3.39)%, respectively, with no statistically significant difference ( t=-0.78, P=0.442). CT-ECV in systole and diastole were (34.15±3.94)% and (35.30±3.99)% for segment 8, (34.03±3.76)% and (35.46±3.74)% for segment 9, and (33.98±3.32)% and (35.05±3.98)% for segment 14, respectively. The mean values of the systolic CT-ECV of segments 8, 9 and 14 were significantly lower than those of diastolic CT-ECV ( t=-2.65, -3.26, -2.42, P=0.012, 0.003, 0.022, respectively). The ICCs for CT-ECV measurements of 16 segments by the two radiologists were greater than 0.90 in both systolic and diastolic, indicating good agreement. Conclusions:There is no significant difference in whole heart CT-ECV values between systolic and diastolic myocardial ECV based on dual-layer spectral CT. However, minor differences (less than 2%) are found between systolic and diastolic myocardial CT-ECV for some segments. Myocardial CT-ECV measurement should be performed on the same segment during the same phase to obtain stable and accurate ECV values.
4.Repair protocol of intraoperative CSF leak after endoscopic endonasal clival malignancy resection
Wei WEI ; Qiuhang ZHANG ; Bo YAN ; Yan QI ; Fanyue MENG ; Li WANG ; Junqi LIU ; Xiaotong YANG ; Zhenlin WANG
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2024;59(11):1152-1158
Objective:To evaluate the repair protocols for intraoperative cerebrospinal fluid (CSF) leaks after endoscopic endonasal clival malignancy resection (EECR) and to analyze the risk factors of surgical complication.Methods:The clinical data of patients who underwent EECR and had intraoperative CSF leaks in XuanWu Hospital, Capital Medical University between January 2012 and January 2024 were reviewed. The pathological results, imaging data, location of the dural defect, degree of intraoperative CSF leaks, repair materials, complications such as postoperative central nervous system (CNS) infections, types of antibiotics used, bacterial culture and drug sensitivity results, secondary repair, and follow-up results were collected. IBM SPSS 26 software was used to evaluate the effectiveness of the repair. Additionally, statistical analysis was conducted on perioperative complications such as CNS infections.Results:Twenty-eight patients underwent 31 EECR and 36 skull base reconstructions. There were 14 females and 14 males, aged from 4 to 70 years old, with a median of 53 years. For the repair, autologous materials such as free turbinate flap, free nasoseptal flap, pedicled nasoseptal flap, and fascia lata combined with mashed muscle were used. Initial reconstruction was successful in 26 cases, while 5 patients required a second repair, which was also successful. Postoperatively CNS infections occurred in 4 patients, and all of whom were cured. Follow-up ranged from 3 to 146 months, with no delayed CSF leak reported. The infection rate was significantly higher in patients whose first repair failed compared to those whose repair was successful (Fisher exact test, P<0.001). Conclusions:The use of different autologous materials based on the patient′s condition can effectively repair CSF leakage that occurs during EECR. Howerver, the success rate of initial repair requires improvement, as the risk of CNS infection significantly increases after a failed repair..
5.Clinical experience of extraperitoneal laparoscopic radical cystectomy in 340 cases
Ke WANG ; Zhaofeng LI ; Zongliang ZHANG ; Kai ZHAO ; Xinbao YIN ; Guanqun ZHU ; Zhenlin WANG ; Han YANG ; Xueyu LI ; Xuechuan YAN ; Qinglei WANG ; Zaiqing JIANG
Journal of Modern Urology 2024;29(9):762-765
Radical cystectomy combined with pelvic lymph node dissection is the standard procedure for the treatment of muscle invasive bladder cancer and complex non-muscle invasive bladder cancer.Our department has routinely carried out laparoscopic radical cystectomy(ELRC)through the extraperitoneal approach in 340 cases.This article summarizes the establishment of the peritoneal space,the expansion of the peritoneal space,the operation steps of bladder resection and lymph node dissection through the peritoneal channel,and how to shorten the operation time and reduce the difficulty of the operation.During the surgery,the bladder is removed periperitoneally without destroying the peritoneum to preserve the functions of peritoneum support,secretion,protection and lubrication,which has little impact on the abdominal organs,reduces the incidence of complications,and provides favorable conditions for subsequent treatment.
6.Feasibility of deep learning combined with compressed sensing technology to improve breath-hold three-dimensional magnetic resonance cholangiopancreatography image quality
Ye YUAN ; Yu ZHANG ; Hanyu LI ; Dao'en ZHANG ; Tingting YANG ; Zhenlin LI ; Chunchao XIA
Chinese Journal of Radiology 2024;58(9):935-940
Objective:To explore the improvement of image quality of different acceleration factors in breath-hold three-dimensional magnetic resonance cholangiopancreatography (3D MRCP) using deep learning (DL) and compressed sensing (CS) technology.Methods:A total of 68 patients who underwent upper abdominal 3D MRCP examination at West China Hospital of Sichuan University from March to August 2023 were prospectively included. The patients were subdivided into three groups randomly with the following paramters: CS group with an acceleration factor of 24 (CS-24); DL-CS group with acceleration factors 24 (DL-CS-24) and 33 (DL-CS-33) respectively. The signal-to-noise ratio (SNR), contrast ratio (CR) and contrast-to-noise ratio (CNR) of the three sets of images were measured, and the overall image quality, background suppression, artifacts, and visibility of bile ducts and pancreatic ducts at all levels were subjectively evaluated. Chi-square test and Friedman test were used to perform statistical analysis on the number of unsatisfactory diagnostic images and subjective and objective indicators of the three groups of sequences respectively.Results:The scanning time of the DL-CS-33 group (9 s) was 30% shorter than that of the CS-24 group and DL-CS-24 group (13s). The images of DL-CS-33 group from 68 patients all met the clinical diagnostic requirements and statistically differences were found between the images from CS-24 group and DL-CS-24 group (all P<0.05). There were no statistically differences in SNR, CR, CNR, overall image quality, artifacts, and visibility scores of bile ducts and pancreatic ducts at all levels between the DL-CS-33 group and the CS-24 group (all P>0.05). The SNR, CR, CNR, intrahepatic bile duct, main pancreatic duct and overall image quality of the DL-CS -24 group were better than those of the CS-24 group (all P<0.05). Conclusions:DL-CS technology could improves breath-hold 3D MRCP image quality with the 24 acceleration factor with no additioanl scanning time. DL-CS technology combined with a high acceleration factor of 33 further reduces scanning time while ensuring overall image quality, providing a fast breath-hold scanning solution.
7.Research on the application of artificial intelligence compressed sensing technology in three-dimensional proton density weighted imaging of the unilateral hip joint
Daoen ZHANG ; Xu XU ; Hanyu LI ; Sixian HU ; Ye YUAN ; Gaofeng ZHANG ; Xiaoyong ZHANG ; Chunchao XIA ; Zhenlin LI
Chinese Journal of Radiology 2024;58(12):1431-1436
Objective:To explore the impact of artificial intelligence compressed sensing technology (CS-AI) on image quality in three-dimensional proton density weighted imaging (3D PDWI) of the unilateral hip joint.Methods:High-resolution unilateral hip imaging was conducted on 67 healthy volunteers at West China Hospital of Sichuan University from January to July 2023. Imaging was performed by using CS-AI 3D PDWI sequence with acceleration factors (AF) of 4, 6, 8, and 10, respectively. According to the AF, all subjects were divided into 4 groups: CS-AI 4, CS-AI 6, CS-AI 8 and CS-AI 10, with CS-AI 4 serving as a reference. Recording the scan time, the signal and noise intensity of the femoral head, muscle, and subcutaneous fat were measured by a senior radiologist and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were then calculated. Additionally, two observers provided ratings for overall image quality and artifacts in the 4 groups, and statistical analysis was performed using the Friedman rank-sum test.Results:The acquisition times for CS-AI 4, CS-AI 6, CS-AI 8, and CS-AI 10 were 5 min 49 s, 3 min 54 s, 2 min 56 s and 2 min 22 s, respectively. Compared to CS-AI 4, the scanning time for CS-AI 6, CS-AI 8, CS-AI 10 were reduced by 32.95%, 50.14%, 59.31%, respectively. The objective evaluation revealed that the SNR and CNR of the femoral head and muscle in groups CS-AI 6, CS-AI 8, and CS-AI 10 were slightly lower than those in group CS-AI 4 ( P<0.05), and the differences were statistically significant. However, no statistically significant differences were found among the 3 groups ( P>0.05). The subjective evaluation indicated that the overall image quality scores of group CS-AI 8 [3 (3,4)] did not significantly differ from those of group CS-AI 4 and CS-AI 6( P>0.05); The mean scores of group CS-AI 4 and CS-AI 6 were 4 (4, 4); Scores of group CS-AI 10 was 3(3, 3), which statistically significant differ from those of the other groups ( P<0.05). The artifacts rating for groups CS-AI 4, CS-AI 6, CS-AI 8 and CS-AI 10 were 4 (4, 4), 4 (4, 4), 3 (3, 4), and 2 (2, 3) respectively. When AF was set to 10, the images exhibited the most severe artifacts ( P<0.05). For other AF values, artifact ratings did not differ significantly ( P>0.05). Conclusion:The CS-AI 3D-PDWI sequence with acceleration factor 8 can acquire high-resolution images of the unilateral hip joint that meet clinical diagnostic requirements while reducing scanning time.
8.Research progress on adenosine and its receptors in bone metabolism
Xu LOU ; Zhenlin ZHANG ; Hua YUE
Chinese Journal of Endocrinology and Metabolism 2024;40(5):450-454
Bone metabolism refers to the dynamic process in which osteoblast-mediated bone formation and osteoclast-mediated bone resorption are coupled, playing a crucial role in maintaining bone homeostasis. Adenosine, as an important component of purinergic signaling pathway, has multiple effects such as inhibition of inflammation, promotion of neovascularization, and modulation of osteoblast proliferation and osteoclast differentiation. The application of adenosine receptor agonists or targeted delivery of adenosine may present a novel approach for addressing clinical challenges such as osteoporosis and poor fracture healing. The purinergic signaling pathway activated by extracellular adenosine has been identified as a key signaling pathway for regulating bone tissue function and homeostasis. This article reviews the regulation of physiological bone metabolism by adenosine and its receptors, as well as the relationship between adenosine and metabolic bone diseases in pathological conditions, aiming to provide reference and direction for understanding the significance of adenosine pathway in the field of bone metabolism, and offer new insights for the treatment of metabolic bone diseases.
9.Feasibility study on second-generation dual-layer detector spectral CT abdominal VNC in diagnosing fatty liver
Yong CHENG ; Jiehao DING ; Yu ZHANG ; Chenghao CAO ; Zhuo ZHENG ; Li PENG ; Xiaodi ZHANG ; Zhenlin LI
Chongqing Medicine 2024;53(18):2804-2809,2814
Objective To explore the feasibility of second-generation dual-layer detector spectral CT ab-dominal virtual non-contrast(VNC) for diagnosing fatty liver.Methods The imaging data of 128 patients with second-generation dual-layer detector spectral CT abdominal enhanced CT in West China Hospital of Si-chuan University from June 2022 to December 2022 were retrospectively analyzed.The CT values of the left lobe,right anterior lobe,right posterior lobe and spleen of all patients were measured on TNC,arterial stage VNC (A-VNC) and venous stage VNC (V-VNC) images.The difference value (L-S) and ratio value (L/S) between the CT value of liver and CT value of spleen were calculated.According to the threshold value of TNC image diagnosis of fatty liver in previous studies,the included cases were divided into two groups:fatty liver group and non-fatty liver group.The Mann-Whitney U test was used to compare the difference of quanti-tative parameters between the fatty liver group and non-fatty liver group.The efficiency of VNC in the diagno-sis of fatty liver was evaluated by the receiver operating characteristic (ROC) curve,and the difference be-tween ROC curves was compared with DeLong's test.The intra-group and inter-group correlation coefficient (ICC) values were used to evaluate the consistency of data measurement.Results The ICC values of intra-group and inter-group consistency of data ranged (0.835-0.986) and (0.810-0.978),respectively (P<0.05).The mean value of left lobe,right anterior lobe,right posterior lobe and triple lobe of liver and CT val-ue of spleen in A-VNC and V-VNC images were lower than those of TNC images,and the differences were statistically significant (P<0.05).The CT values of TNC,A-VNC,V-VNC,(L-S) values and (L/S) values of the non-fatty liver group were higher than those of the fatty liver group,and the differences were statistical-ly significant (P<0.05).The CT value,(L-S) value and (L/S) value of TNC,A-VNC and V-VNC images in the non-fatty liver group were higher than those in the fatty liver group,and the differences were statistically significant (P<0.05).The area under the curve (AUC) of CT values of A-VNC and V-VNC for the diagnosis of fatty liver all were 0.997,and their efficiencies for diagnosing fatty liver had no statistical difference (Z=0.407,P=0.684).AUC of A-VNC (L-S) and V-VNC (L-S) in the diagnosis of fatty liver was 1.000 and 0.981,respectively,and their efficiencies for diagnosing fatty liver had no statistical difference (Z=1.790,P=0.074).AUC of A-VNC (L/S) and V-VNC (L/S) in the diagnosis of fatty liver was 0.992 and 0.987,respec-tively,and their efficiencies for diagnosing fatty liver also had no statistical difference (Z=0.665,P=0.506). Conclusion The CT values of liver and spleen in VNC images reconstructed by second-generation dual-layer detector spectral CT are lower than TNC,but it is still feasible to diagnose fatty liver based on VNC images.
10.Extraskeletal effects and related mechanisms of Vitamin D
Wendi YANG ; Tian XU ; Zhenlin ZHANG ; Hua YUE
Chinese Journal of General Practitioners 2024;23(6):675-680
Vitamin D regulates calcium and phosphorus homeostasis, promotes bone growth, development and mineralization, therefore plays an important role in maintaining bone health. In recent years, the extraskeletal effects of vitamin D have received increasing attention with further research. Studies have shown that vitamin D is involved in the occurrence and development of various diseases, and vitamin D deficiency may lead to increased disease risk. However, there is still controversy over whether supplementing vitamin D brings definitely clinical benefits. This article reviews the extraskeletal effects and related mechanisms of vitamin D in obesity, diabetes, cardiovascular diseases, immunoregulation, oncogenesis and sarcopenia, providing information for further study on its biological activities and clinical applications.

Result Analysis
Print
Save
E-mail