1.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
2.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
3.Comparison of clinical characteristics between first-episode and relapse of major depressive disorder
Xiuyan ZHENG ; Chengxia TANG ; Zhaorui LIU ; Tingting ZHANG ; Yueqin HUANG ; Liang ZHOU ; Yuandong GONG ; Yan LIU ; Bo LIU ; Jie ZHANG ; Haiming WANG ; Zhengmin FENG ; Jun GUO ; Wenming CHEN ; Linling JIANG ; Defang CAI ; Jin LU
Chinese Mental Health Journal 2024;38(1):25-32
Objective:To describe demographic,clinical and physiological characteristics,treatment between first-episode major depressive disorder(MDD)and relapse MDD,and to explore characteristics of relapse MDD.Methods:Totally 858 patients who met the diagnostic criteria for depression of the Diagnostic and Statistical Manual of Mental Disorders,Fifth Edition(DSM-5),were included by using the Mini International Neuropsychiatric Interview(MINI),Clinician-Rated Dimensions of Psychosis Symptom Severity,and Hamilton Depression Scale etc.Among them,529(58.6%)were first-episode depression and 329(36.0%)were relapsed.The differences of demographic characteristics,clinical and physiological characteristics,treatment were compared byx2test and Kruskal-Wallis rank sum test.Multivariate logistic regression was used to explore the characteristics of MDD recur-rence.Results:Compared to first-episode MDD,relapse MDD had more comorbidity(OR=2.11,95%CI:1.00-4.44),more days out of role(OR=1.26,95%CI:1.01-1.56),more history of using psychiatric drug more than one month(OR=1.41,95%CI:1.02-1.97)and electroconvulsive therapy(OR=3.23,95%CI:1.42-7.36),and higher waist-hip ratio(OR=33.88,95%CI:2.88-399.32).Conclusion:Relapse MDD has positive as-sociation with comorbidity of mental disorders,out of role,and higher waist-hip ratio.
4.Hippo pathway-manipulating neutrophil-mimic hybrid nanoparticles for cardiac ischemic injury via modulation of local immunity and cardiac regeneration.
Qiaozi WANG ; Yanan SONG ; Jinfeng GAO ; Qiyu LI ; Jing CHEN ; Yifang XIE ; Zhengmin WANG ; Haipeng TAN ; Hongbo YANG ; Ning ZHANG ; Juying QIAN ; Zhiqing PANG ; Zheyong HUANG ; Junbo GE
Acta Pharmaceutica Sinica B 2023;13(12):4999-5015
The promise of regeneration therapy for restoration of damaged myocardium after cardiac ischemic injury relies on targeted delivery of proliferative molecules into cardiomyocytes whose healing benefits are still limited owing to severe immune microenvironment due to local high concentration of proinflammatory cytokines. Optimal therapeutic strategies are therefore in urgent need to both modulate local immunity and deliver proliferative molecules. Here, we addressed this unmet need by developing neutrophil-mimic nanoparticles NM@miR, fabricated by coating hybrid neutrophil membranes with artificial lipids onto mesoporous silica nanoparticles (MSNs) loaded with microRNA-10b. The hybrid membrane could endow nanoparticles with strong capacity to migrate into inflammatory sites and neutralize proinflammatory cytokines and increase the delivery efficiency of microRNA-10b into adult mammalian cardiomyocytes (CMs) by fusing with cell membranes and leading to the release of MSNs-miR into cytosol. Upon NM@miR administration, this nanoparticle could home to the injured myocardium, restore the local immunity, and efficiently deliver microRNA-10b to cardiomyocytes, which could reduce the activation of Hippo-YAP pathway mediated by excessive cytokines and exert the best proliferative effect of miR-10b. This combination therapy could finally improve cardiac function and mitigate ventricular remodeling. Consequently, this work offers a combination strategy of immunity modulation and proliferative molecule delivery to boost cardiac regeneration after injury.
5.The applicability of Beckman PK7300 fully automatic blood group instrument for TPPA detection
Junjie JIA ; Zhengmin LIU ; Rui WANG ; Nan GAO ; Rui LIU ; Jin GUO
Chinese Journal of Blood Transfusion 2023;36(1):72-75
【Objective】 To investigate the applicability of Beckman PK7300 for TPPA testing on anti-TP reactive specimens from blood donors. 【Methods】 1) The TPPA test using Beckman PK7300 (abbreviated as instrument method) had been established and the performance was verificated by calculating the total compliance rate, positive compliance rate and negative compliance rate as compared with the manual method. The repeatability of this instrument method was also evaluated. 2) The applicability of the instrument method was evaluated by examing 555 TP-reactive samples for 6 consecutive days, so as to analyze the readable reading rate, agglutination strength distribution and other control methods. 【Results】 1) The total, positive, and negative compliance rates of TPPA detection by both instrumental and manual methods were 100% (kappa value =1). The SPC value of samples, read manually as " + + ", was less than or equal to 3 by Beckman PK7300; the SPC value of samples, read manually as " -", was greater than or equal to 20 by Beckman PK7300. The two methods were well consistent. The instrument method was repeated for 12 times for the same samples, and the accuracy rate was 100% (12 / 12), with good repeatability.2) The results of the TPPA test in 555 anti-TP reactivity specimens showed an overall readable rate of 99.82%(554/555). The SPC values of the negative and unsensitized particles of TPPA were distributed on both sides of the determination value without crossover. The control and monitor thoughout the test were carried out automatically by the instrument. 【Conclusion】 The TPPA test conducted by the Beckman PK7300 fully automatic blood group instrument is suitable for the confirmatory experiment of anti-TP reactive specimens in blood center laboratories, which could realize the automation and standardization of TPPA detection.
6.Temporal and spatial stability of the EM/PM molecular subtypes in adult diffuse glioma.
Jing FENG ; Zheng ZHAO ; Yanfei WEI ; Zhaoshi BAO ; Wei ZHANG ; Fan WU ; Guanzhang LI ; Zhiyan SUN ; Yanli TAN ; Jiuyi LI ; Yunqiu ZHANG ; Zejun DUAN ; Xueling QI ; Kai YU ; Zhengmin CONG ; Junjie YANG ; Yaxin WANG ; Yingyu SUN ; Fuchou TANG ; Xiaodong SU ; Chuan FANG ; Tao JIANG ; Xiaolong FAN
Frontiers of Medicine 2023;17(2):240-262
Detailed characterizations of genomic alterations have not identified subtype-specific vulnerabilities in adult gliomas. Mapping gliomas into developmental programs may uncover new vulnerabilities that are not strictly related to genomic alterations. After identifying conserved gene modules co-expressed with EGFR or PDGFRA (EM or PM), we recently proposed an EM/PM classification scheme for adult gliomas in a histological subtype- and grade-independent manner. By using cohorts of bulk samples, paired primary and recurrent samples, multi-region samples from the same glioma, single-cell RNA-seq samples, and clinical samples, we here demonstrate the temporal and spatial stability of the EM and PM subtypes. The EM and PM subtypes, which progress in a subtype-specific mode, are robustly maintained in paired longitudinal samples. Elevated activities of cell proliferation, genomic instability and microenvironment, rather than subtype switching, mark recurrent gliomas. Within individual gliomas, the EM/PM subtype was preserved across regions and single cells. Malignant cells in the EM and PM gliomas were correlated to neural stem cell and oligodendrocyte progenitor cell compartment, respectively. Thus, while genetic makeup may change during progression and/or within different tumor areas, adult gliomas evolve within a neurodevelopmental framework of the EM and PM molecular subtypes. The dysregulated developmental pathways embedded in these molecular subtypes may contain subtype-specific vulnerabilities.
Humans
;
Brain Neoplasms/pathology*
;
Neoplasm Recurrence, Local/metabolism*
;
Glioma/pathology*
;
Neural Stem Cells/pathology*
;
Oligodendrocyte Precursor Cells/pathology*
;
Tumor Microenvironment
7.The Clinical Characteristics of Electrolyte Disturbance in Patients with Moderate and Severe Traumatic Brain Injury Who Underwent Craniotomy and Its Influence on Prognosis
Geng Huan WANG ; Yu YAN ; He Ping SHEN ; Zhengmin CHU
Journal of Korean Neurosurgical Society 2023;66(3):332-339
Objective:
: The present study aimed to investigate the clinical characteristics of electrolyte imbalance in patients with moderate to severe traumatic brain injury (TBI) who underwent craniotomy and its influence on prognosis.
Methods:
: A total of 156 patients with moderate to severe TBI were prospectively collected from June 2019 to June 2021. All patients underwent craniotomy and intracranial pressure (ICP) monitoring. We aimed to explore the clinical characteristics of electrolyte disturbance and to analyze the influence of electrolyte disturbance on prognosis.
Results:
: A total of 156 patients with moderate and severe TBI were included. There were 57 cases of hypernatremia, accounting for 36.538%, with the average level of 155.788±7.686 mmol/L, which occurred 2.2±0.3 days after injury. There were 25 cases of hyponatremia, accounting for 16.026%, with the average level of 131.204±3.708 mmol/L, which occurred 10.2±3.3 days after injury. There were three cases of hyperkalemia, accounting for 1.923%, with the average level of 7.140±1.297 mmol/L, which occurred 5.3±0.2 days after injury. There were 75 cases of hypokalemia, accounting for 48.077%, with the average level of 3.071±0.302 mmol/L, which occurred 1.8±0.6 days after injury. There were 105 cases of hypocalcemia, accounting for 67.308%, with the average level of 1.846±0.104 mmol/L, which occurred 1.6±0.2 days after injury. There were 17 cases of hypermagnesemia, accounting for 10.897%, with the average level of 1.213±0.426 mmol/L, which occurred 1.8±0.5 days after injury. There were 99 cases of hypomagnesemia, accounting for 63.462%, with the average level of 0.652±0.061 mmol/L, which occurred 1.3±0.4 days after injury. Univariate regression analysis revealed that age, Glasgow coma scale (GCS) score at admission, pupil changes, ICP, hypernatremia, hypocalcemia, hypernatremia combined with hypocalcemia, epilepsy, cerebral infarction, severe hypoproteinemia were statistically abnormal (p<0.05), while gender, hyponatremia, potassium, magnesium, intracranial infection, pneumonia, allogeneic blood transfusion, hypertension, diabetes, abnormal liver function, and abnormal renal function were not statistically significant (p>0.05). After adjusting gender, age, GCS, pupil changes, ICP, epilepsy, cerebral infarction, severe hypoproteinemia, multivariate logistic regression analysis revealed that hypernatremia or hypocalcemia was not statistically significant, while hypernatremia combined with hypocalcemia was statistically significant (p<0.05).
Conclusion
: The incidence of hypocalcemia was the highest, followed by hypomagnesemia, hypokalemia, hypernatremia, hyponatremia and hypermagnesemia. Hypocalcemia, hypomagnesemia, and hypokalemia generally occurred in the early post-TBI period, hypernatremia occurred in the peak period of ICP, and hyponatremia mostly occurred in the late period after decreased ICP. Hypernatremia combined with hypocalcemia was associated with prognosis.
8.Analysis of reactive HCV results detected by current blood screening strategy
ZhengMin LIU ; Rui WANG ; Jin GUO ; Jing ZHANG ; Yi ZHA ; Hongwei GE ; Ling LI
Chinese Journal of Blood Transfusion 2022;35(1):53-57
【Objective】 To assess the status of HCV infection by analyzing the results of anti-HCV reactive blood samples detected by the current blood testing strategy, and discuss the viability of classified management of reactive blood donors. 【Methods】 The anti-HCV reactive samples (dual ELISA and once NAT), from May 2017 to October 2018, were divided into three groups: samples both anti-HCV and HCV RNA reactive, sole HCV RNA reactive, and sole anti-HCV reactive, and all of them were confirmed by recombinant immunoblot assay (RIBA). The positive predictive value (PPV) between groups were compared. The sensitivity, specificity and PPV for each reagent under different screening threshold (screening threshold for routine detection, optimal screening threshold, and corresponding screening threshold of the highest PPV) were analyzed. The group with low PPV were stratified by ELISA S/CO values, and PPV by different screening threshold was compared. 【Results】 There were 939 reactive samples (0.49%, 937/191 627). Confirmed by RIBA, the positive rate of anti-HCV reactive samples was 10.67%(100/937). Two samples were sole HCV RNA reactive (0.001%). Both anti-HCV+ HCV RNA reactive samples were 6.71%(63/939), with the PPV of 96.83%(61/63). Sole anti-HCV reactive samples were 93.08(874/939), with the PPV of 4.46%(39/874), among which PPV by dual and one ELISA reagent were 18.72% and 0.15%, respectively, showing statistically significant difference (P<0.05). The PPV between different S/CO values was statistically significant (P<0.05). The optimal screening thresholds of anti-HCV reagent were 9.29 and 3.97, according to the ROC curve, with significant difference noticed in PPV by different screening threshold (P<0.05). PPV in the sole anti-HCV reactive group increased from 4.46% (the routine screening threshold) to 49.35%(the optimal screening threshold), and the difference was statistically significant (P<0.05). 【Conclusion】 The blood donors with both anti-HCV and HCV RNA reactive can be determined as HCV infection and need to be permanently deferred. The S/CO value of sole anti-HCV reactive samples was positively correlated with RIBA confirmation results, and the higher the S/CO value, the greater the chances of positive confirmation are. With the current blood screening strategy, the HCV infection status of sole anti-HCV reactive blood donors can be determined by establishing a screening threshold with high PPV or adding confirmatory test.
9.Study on blood donor deferral strategy by analyzing anti-TP test results
Jing SUN ; Rui WANG ; Zhengmin LIU ; Jin GUO ; Nan GAO ; Junjie JIA ; Hongwei GE ; Ling LI
Chinese Journal of Blood Transfusion 2022;35(2):176-179
【Objective】 To discuss the reliability and applicability of the current blood deferral strategy concerning anti-TPreactive blood donors (by ELISA). 【Methods】 TPPA confirmatory test was performed on the samples routinely detected by two different anti-TP ELISA reagents(reagent 1 and reagent 2), and the test data of dual reagent reactive and one reagent reactive blood donors were analyzed to determine the possibility of true positivity. 【Results】 1 624 anti-TP reactive samples(by ELISA) were collected, among which 1 467 were dual reagent reactive, 77 were reagent 1 reactive, and 80 were reagent 2 reactive. TPPA results showed that the positive predictive value (PPV) of dual reactive samples was 85.48%. Samples with high S/CO value (reagent 1≥13 and/or reagent 2 >17) were more likely to be true positive, with the PPV at 98.56% (reagent 1) and 99.13% (reagent 2), respectively, which were significantly higher than that when the S/CO value was≥1. Among the samples reactive to one reagent, 2 were confirmed positive in reagent 1 and 3 in reagent 2, with the PPV at 2.60% and 3.75% respectively, and had no correlation with high S/CO value. 【Conclusion】 Dual-reagent reactive donors with high S/CO value showed high possibility of true positivity, therefore should be deferred. TPPA test is helpful to identify true positivity in one-reagent reactive donors. Confirmatory test and follow-up should be a supplement to the current blood donor deferral strategy to ensure blood safety.
10.Classification management of HIV reactive blood donors based on test results
Rui WANG ; Ling LI ; Zhengmin LIU ; Jin GUO ; Jinghui HU ; Jing ZHANG ; Hongwei GE ; Zhong LIU
Chinese Journal of Blood Transfusion 2022;35(3):296-300
【Objective】 To explore the viability of classification management of HIV reactive blood donors based on test results in blood screening laboratory. 【Methods】 According to the HIV test results of blood donors (including twice ELISA and once NAT), the HIV reactive blood donors were divided into three groups. Group 1 was all-test reactive (both ELISA and NAT were reactive), group 2 serological reactive (only ELISA was reactive), and group 3 NAT reactive (only NAT was reactive). The HIV test results of 191 628 blood donors from May to December 2017 were analyzed. Samples with positive RIBA results and / or the repeated reactive NAT results were determined as HIV true positive. The yielding rates of HIV true positivity in each group were analyzed. Receiver operating characteristic curve (ROC curve) was used to elevate the S/CO limit under 99% specificity as the blood donor deferral limit for ELISA. 【Results】 A total of 180 HIV reactive samples were detected out of 191 628 blood donors, including 77 positive cases in group 1, 100 in group 2 and 3 in group 3. 1) The HIV reactive results were diverse. Among the 82 true positive blood donors, 4 were early HIV infection (3 HIV antibody+ antigen window period yield, 1 HIV antibody window period yield), 2 were suspected elite controllers, and 76 cases were both serology and NAT reactive. 2) The overall yielding rate of HIV was 47.67%, with group 1 (100%) = group 3 (100%) > group 2 (2.17%), showing statistically significant (P<0.01). 3) The blood donor deferral limit for ELISA1, ELISA2 was 5.40 and 9.69 (S/CO value), respectively, with the corresponding positive expective values of 98.73% and 91.14% (P>0.05). All true positive blood donors in group 1 and group 2 could be accurately screened by using the blood donor deferral limit for ELISA1 and ELISA2 simultaneously. 【Conclusion】 The composition of HIV results among blood donors is diverse and complex. It is necessary to continuously improve the awareness of HIV prevention and control. The classification of HIV reactive blood donors is conducive to conduct fine and scientific management. The blood donors in group 1 and group 3 should be permanently deferral, and the suspected HIV elite controllers in group 2 should be paid attention to and permanently deferral.

Result Analysis
Print
Save