1.Study on the Application of A New Type of Anhydrous Thoracic Negative Pressure Drainage Device in Patients after Thoracic Surgery.
Wenfeng YU ; Liang PAN ; Jieping ZHANG ; Peng YE ; Zhengliang TU ; Wang LV ; Jian HU
Chinese Journal of Lung Cancer 2020;23(6):509-513
BACKGROUND:
After general thoracic surgery, a chest tube is usually placed for closed drainage to expel gas accumulation in the thoracic cavity and fluid accumulation to promote lung re-expansion. It can also be observed whether there is active bleeding after the operation and whether there is a pulmonary leak. The conventional drainage of the chest cavity is connected with a water-sealed drainage bottle, and the patient condition is judged by observing the drainage situation and the fluctuation of the water column, which is a very classic method. However, the water-sealed bottle has the disadvantages of being easy to overturn and inconvenient to carry, which is not conducive to the early activities of patients. Under the concept of accelerated rehabilitation, our center applied a new type of anhydrous thorax negative pressure drainage device and achieved good results. The purpose of this study was to observe the effect of a new type of anhydrous thoracic negative pressure drainage device in patients after thoracic surgery.
METHODS:
Retrospective analysis of patients who underwent lung surgery in the First Affiliated Hospital of Zhejiang University Medical College from January 2018 to December 2019, patients were divided into two groups. One group of patients used a traditional closed-chest drainage water-sealed bottle as a control group, and the other group used a new type of anhydrous negative-pressure drainage bottle as an experimental group. Patients' gender, age, hypertension, diabetes, smoking history, surgical incisions and surgical methods, and the length of hospital stay and postoperative hospital stay were calculated.
RESULTS:
There were no statistical differences in age, gender, comorbidities (hypertension, diabetes, smoking history), scope of surgery, and duration of surgery between the two groups of patients, but there were statistical differences in surgical incisions between the two groups of patients (P=0.01). We found that patients using the new waterless negative pressure drainage device were shorter than patients with water negative pressure drainage device in terms of postoperative hospital stay and total hospitalization time, and the difference was statistically significant (P=0.02, P=0.04).
CONCLUSIONS
The new type of anhydrous thoracic negative pressure drainage device has a good effect on the rapid recovery and advancement after thoracic surgery.
2.Distribution and correlation of 20 kinds of inorganic elements in Jiawei Xiaoyao Formula
Yali ZHANG ; Wei SUN ; Lei ZHANG ; Zhengliang YE
Drug Evaluation Research 2017;40(3):329-334
Objective To study the distribution and correlation of 20 kinds of inorganic elements (Na,Mg,A1,V,Cr,Co,Fe,Ni,Cu,Zn,Mn,As,Se,Cd,Cs,Sr,Ag,Hg,Pb,and U) in Jiawei Xiaoyao Formula (JXF).Methods The levels of 20 inorganic elements in 10 kinds of herbal substances were determined by ICP-MS with microwave digestion for sample preparation,and the results were analyzed with SPSS22.0.Results There were some correlations among the inorganic elements in JXF;Four main factors were selected by principal component analysis (PCA).The PCA results showed that Na,Mg,A1,V,Ni,Cu,Se,Sr,Cs,Mn,Hg,and Fe might be the characteristic elements in JXF;There were Mg,A1,Mn,and Fe elements in 10 herbal drugs,the contents of inorganic elements in herbal drug were different because the medicinal parts were different,and the decreasing order was roots and rhizomes,skin type,all grass,fruit seeds,and fungi.Conclusion Contents of inorganic elements can not only characterize the stability of extraction process,and can provide experimental evidence for the study of traditional Chinese medicine compound compatibility law.
3.Comparison of forensic parameters between length-based and sequence-based STR models
Peng ZHAO ; Guangfeng ZHANG ; Jing LIU ; Zhengliang YU ; Zhen XU ; Jian YE ; Anquan JI ; Le WANG
Chinese Journal of Forensic Medicine 2017;32(6):642-644,648
Capillary electrophoresis-based STR genotyping is accepted as the gold standard for human individual identification. Next generation sequencing (NGS) allows for the full resolution of STR base composition, and has the potential to be widely used in the field of forensics. Compared with length polymorphism, STR sequencing could provide more information, and quantitatively calculating the forensic parameters is necessary. In this paper, we established simple models for length-based and sequence-based STRs, and calculated the forensic parameters for both models. The results showed that for a single STR locus, compared with length polymorphism, STR sequence polymorphism could provide higher power of discrimination and power of exclusion, indicating sequence-based STR marker have stronger ability for identifying unrelated individuals and exclude non biological father. By combining 15 non-linkage loci for forensic DNA analysis, the cumulative matching probability values for length-based and sequence-based STR models are at 10-18and 10-26levels, respectively. Only 10 non-linkage sequence-based STR is required to reach a cumulative matching probability of as high as 15 length-based STR loci. It is hoped that these simulated models and calculations can provide a reference for the forensic application of NGS-based STR genotyping.
4.Compatibility Stability of Salvianolic Acid for Injection Combined with 8 Kinds of Common Solvents
Yan ZHOU ; Dekun LI ; Dazheng ZHOU ; Yuewu YANG ; Aichun JU ; Xiaoyi WANG ; Zhengliang YE
China Pharmacy 2017;28(17):2350-2356
OBJECTIVE:To investigate the compatibility stability of Salvianolic acid for injection (SAFI) combined with 8 kinds of common solvents. METHODS:Referring to package inserts,SAFI was collected and combined with 0.9% Sodium chlo-ride injection,5% Glucose injection,10% Glucose injection,Compound sodium chloride injection,Mannitol injection,Glycerol fructose and sodium chloride injection,Sodium lactate Ringer's injection,Glucose and sodium chloride injection,250 mL each re-spectively,and then sealed in the dark at the room temperature. The appearance of mixtures were observed,pH value,the number of insoluble particles,maximal absorption wavelength and maximal absorbance were detected,and the contents of salvianolic acid B,rosmarinic acid,lithospermic acid and salvianolic acid Y in mixtures were determined by HPLC at 0,1,2,4,8 h after mix-ing. RESULTS:Under above condition,no obvious change was found in appearance or pH values of the mixtures within 8 h. Maxi-mal absorption wavelength ranged 284.5-286.0 nm. After mixed with Mannitol injection,the number of particles≥10μm(1-8 h af-ter mixing)and particles ≥25 μm(4-8 h after mixing)exceeded the scope of Chinese Pharmacopoeia(2015 edition);the maxi-mal absorbance changed significantly(RSD=9.17%,n=5);the relative content of salvianolic acid B,rosmarinic acid,lithosper-mic acid and salvianolic acid Y decreased by more than 10%(RSD=14.65%,6.45%,8.97%,12.49%,n=5);after mixed with Sodium lactate Ringer's injection,the relative content of rosmarinic acid and lithospermic acid changed greatly (RSD=14.57%, 7.28%,n=5);after mixed with 5% Glucose injection(4-8 h after mixing)and Glycerol fructose and sodium chloride injection(8 h after mixing),the relative content of rosmarinic acid were less than 90%(RSD=6.30%,4.86%,n=5);and the number of particles ≥25μm exceeded the scope of phamcopoeia after mixing with Glycerol fructose and sodium injection(0 h). The number of insoluble particles in other mixtures were in line with the standard of pharmacopoeia;maximal absorbance had no significant change(RSD<5%,n=5),and the relative content change of analytes were all less than 10%. CONCLUSIONS:Clinical appli-cation of SAFI combined with Mannitol injection,Sodium lactate Ringe's injection and Glycerol fructose and sodium injecrion should be avoided. After mixed with 5% Glucose injection,SAFI should be used within 4 h. SAFI can be compatible with 0.9%Sodium chloride injection,10% Glucose injection,Compound sodium chloride injection and Glucose and sodium chloride injec-tion.
5.Research progress in fingerprint of Compound Danshen Dripping Pills and its raw materials
Juanjuan ZHANG ; Wei SUN ; Lei ZHANG ; Zhengliang YE
Drug Evaluation Research 2017;40(6):859-865
Compound Danshen Dripping Pills has curative effect of angina pectoris,coronary heart disease,and other cardiovascular and cerebrovascular diseases,which is widely used in clinic.With the development of basic research and clinical pharmacology,it is particularly important to carry out more comprehensive and systematic quality control.At present,fingerprint technology is developing rapidly and has been recognized by many countries.In this article,we summarized the research situation of Compound Danshen Dropping Pills and its raw materials from two aspects of chromatography and spectroscopy (such as LC,CE,IR,NMR and so on).It will provide reference or the further establishment of a reasonable quality control method.
6.Effect of determination of metals in Cardeniajasminoides Ellis by ICP-MS from online internal standard solution
Yali ZHANG ; Wei SUN ; Lei ZHANG ; Mingpeng MAO ; Zhengliang YE
Drug Evaluation Research 2017;40(4):500-505
Objective To provide a proper concentration of Internal Standard Solution by comparing five different degrees to the simultaneous analysis of 10 metals including V,Cr,Mn,Fe,Ni,Cu,As,Cd,Pb and Hg in Cardeniajasminoides.Method An Inductively Coupled Plasma-Mass Spectrometry method with Microwave-Assisted Digestion was developed with10,50,200,500,1 000 μg/L of Ge,In,Bi as internal standard.Result The degree of 500 μg/L concentration of internal stand solution can both correct the matrix effect and alleviate the contamination as the 1 000 μg/L.Conclusion With excellent detection limits,high sensitivity and wide linear range,the 500 μg/L internal standard may serve as reference in the determination of elements in other traditional Chinese medicine (TCM).
7.Study on Contents Determination and Transport Rates of 18 Toxic Elements from 10 Ingredients of Modi-fied Xiaoyao Formula and Their Extracts
Yali ZHANG ; Wei SUN ; Lei ZHANG ; Mingpeng MAO ; Zhengliang YE
China Pharmacy 2017;28(18):2564-2568
OBJECTIVE:To establish a method for simultaneous determination of 18 toxic elements from 10 ingredients of Modified xiaoyao formula and their extracts,and to study transport rates of above elements. METHODS:Microwave digestion-in-ductively coupled plasma mass (ICP-MS) was used to determine above elements. Radio-frequency power was 1.50 kW,atomiza-tion pressure was 720 kPa,sampling depth was 7 mm,plasma gas flow rate was 15.0 L/min,carrier gas flow rate was 1.00 L/min, spray chamber temperature was 2℃,He flow rate was 4.5 mL/min under collision mode,measurement points/peak was 3,data ac-quisition mode was jump mode. RESULTS:The linear ranges of As,Pb,Cu,Hg,Cd,Mo,V,Cr,Mn,Fe,Ni,Zn,Ru,Rh, Pd,Os,Ir,Pt was 0-500.17 ppb(r was 0.9994-09999);LOD was 0.0004-5.3410 ng/g;RSD of repeatability tests was all lower than 5.0%;average recoveries were 82.0%-117.9%(RSD=0.2%-5.7%,n=9). Ru,Rh,Pd,Os,Ir,Pt,Hg had not been detect-ed. The transfer rates of 11 metals in the extracts ranged 1.46%-31.90%. CONCLUSIONS:The method is simple,precise,stable and repeatable,and can be used for simultaneous determination of 18 toxic elements in 10 ingredients of Modified xiaoyao formula and their extracts. The contents of toxic elements are decreased during the preparation of Modified xiaoyao formula extract to guar-antee the safety of drug use to certain extent.
8.Rapid Determination of Multi-maker Ingredients in Salvia miltiorrhiza by Near Infrared Diffused Reflection Spectroscopy
Zhen LI ; Lihong ZHOU ; Gongjun YANG ; Zhengliang YE
China Pharmacy 2017;28(30):4247-4251
OBJECTIVE:To establish the method for rapid determination of nuezhenoside in Salvia miltiorrhiza.METHODS:The contents of salvianolic acid B,rosmarinic acid,lithospermic acid and tanshinone (tanshinone Ⅱ A+tanshinone Ⅰ +cryptotanshinone) were determined by HPLC (as reference value).Quantitative model for the contents of above components was established by partial least square (PLS)-NIR spectra.According to the reference value,143 samples were collected and the spectrum was pretreated by first-order derivative.The optimal range of wave band for salvianolic acid B,rosmarinic acid,oxalic acid and tanshinone were 6 773.98-3 981.12,6 670.85-3 996.54,8 544.66-3 936.28,8 188.06-3 875.31 cm-1.RESULTS:The methodology for the content determination of salvianolic acid B,rosmarinic acid,oxalic acid and tanshinone were in line with the requirement.The coefficient (R2) of internal cross validation for quantitative correction model of salvianolic acid B,rosmarinic acid,oxalic acid and tanshinone were 0.919 0,0.832 2,0.821 5,0.925 6.The deviation of corrected mean square roots were 4.46,0.48,1.34,0.71,respectively.The R2 values of external validation were 0.852 6,0.957 3,0.819 3,0.953 1,respectively;and mean square root of prediction error (RMSEP)were 9.77,0.28,0.94,0.63,respectively.CONCLUSIONS:The method is rapid,accurate,simple and pollution-free,and can be used for rapid determination of multi-maker ingredients in S.miltiorrhiza.
9.Research of the Variation Rule and Influencing Factors of 5-hydroxymethylfurfural in the Extraction Pro-cess of Schisandra chinensis
Yue LI ; Shengjun MU ; Dekun LI ; Yuewu YANG ; Boyang YU ; Zhengliang YE ; Aichun JU
China Pharmacy 2015;(28):3980-3982,3983
OBJECTIVE:To explore the content variation rule and influencing factors of 5-hydroxymethylfurfural(5-HMF)in the extraction process of the herbs Schisandra chinensis and improve the quality of monitoring the extract of Schisandra chinensis. METHODS:High performance liquid chromatography was adopted to determine the contents of 5-HMF in the extracts during the extraction process (decoction,vacuum concentration,alcohol precipitation,vacuum drying,alkali adjustment),and the content variation rule was found out. For vacuum drying during which the content of 5-HMF reduced obviously,the effects of the tempera-ture and time of drying on the content of 5-HMF were studied,and the effects of vacuum drying and freeze drying on the 5-HMF contents were compared. RESULTS:The content variation trend in the extraction process of Schisandra chinensis was as follows as a large amount of 5-HMF was produced in the herbs decoction process;the content of 5-HMF increased during concentration,re-duced during the alcohol precipitation and the vacuum drying of the extracts by three times concentrate,and maintained substantial-ly unchanged during alkali adjustment. In the process of vacuum drying,the content of 5-HMF decreased with temperature rise and time extension. Freeze drying had no effect as good as that of vacuum drying in the reduction in the content of 5-HMF. CON-CLUSIONS:It is suggested that the vacuum drying of the extracts by three times concentrate at higher temperature,which may pro-duce the extract of Schisandra chinensis with lower content of 5-HMF and thus improve the quality of Schisandra chinensis extract.
10.Evaluation methods for quality volatility about yiqi fumai freeze-dried powder used for injection based on bio-thermodynamics exosyndrome.
Yan YAN ; Dan YAN ; Ping ZHANG ; Zhengliang YE ; Dazheng ZHOU ; Xiaohe XIAO
China Journal of Chinese Materia Medica 2012;37(1):41-45
Yiqi Fumai freeze-dried powder for injection was used as a model drug to establish an evaluation method mainly based on bio-thermodynamics profile detection. Fischer function was used to analyze the chemical and biological data In general, chemical chromatogram can distinguish the expired sample and thermal spectrum of biological activity can distinguish special samples exactly. Thus, we established the evaluation method regarding the quality volatility of Yiqi Fumai freeze-dried powder for injection. The method can be used as a useful supplement in quality control as, and it could provide some technical information for quality control of other varieties of traditional Chinese medicine for injection.
Biological Assay
;
methods
;
Chromatography, High Pressure Liquid
;
methods
;
Drug Therapy
;
Drugs, Chinese Herbal
;
chemistry
;
pharmacology
;
standards
;
Escherichia coli
;
chemistry
;
drug effects
;
growth & development
;
Humans
;
Kinetics
;
Powders
;
chemistry
;
pharmacology
;
standards
;
Quality Control
;
Thermodynamics

Result Analysis
Print
Save
E-mail