1.Assessment of the implementation of Radiation shielding requirements for radiotherapy room—Part 4: Radiotherapy room of 252Cf neutron afterloading (GBZ/T 201.4-2015)
Yuze YANG ; Hongfang WANG ; Haoxian YANG ; Quan WU ; Mingsheng LI ; Bala HARI ; Yongzhong MA ; Zechen FENG ; Bin BAI ; Jie GAO ; Wei ZHOU ; Weixu HUANG ; Zhengjie SHI ; Hezheng ZHAI
Chinese Journal of Radiological Health 2025;34(5):660-665
Objective To track and evaluate the implementation and application of the occupational health standard Radiation shielding requirements for radiotherapy room—Part 4: Radiotherapy room of 252Cf neutron afterloading (GBZ/T 201.4-2015) by radiation health technical service agencies, medical institutions, health supervision agencies, and radiotherapy facility design units, and to provide a scientific basis for the further revision and implementation of this standard. Methods Following the Guideline for health standards tracking evaluation (WS/T 536-2017) and the project implementation plan, relevant practitioners were randomly selected for a questionnaire survey. The survey primarily focused on their awareness, standard training, application, and revision suggestions of GBZ/T 201.4-2015. The results were summarized and analyzed. Results A total of 168 evaluation questionnaires were collected from relevant practitioners in 28 provinces. Only 31.6% of the respondents reported being “well familiar” or “ familiar” with the standard, 27.4% of the respondents believed that the standard was widely used, and 45.2% of the respondents believed that the standard could meet the needs of their work. Only 14.9% of the respondents had received relevant training on the standard, more than half of the respondents had not applied the standard within the past 10 years, and 45.2% of the respondents believed that the standard "needs to be revised". Conclusion Due to the small number of californium-252 neutron afterloading radiotherapy devices in operation on the market, the overall awareness of the standard is low, suggesting that relevant authorities need to strengthen training and publicity of the standard, and that certain sections of the standard need to be revised or merged.
2.Yiqi Wenyang Prescription inhibits autophagy and protects ZO-1 and occludin in nasal mucosal cells of an allergic rhinitis murine model
Wenzhe GU ; Jun SHI ; Daonan YAN ; Zhengjie SHEN
Journal of Beijing University of Traditional Chinese Medicine 2024;47(3):364-373
Objective We aimed to (i) observe the therapeutic effect of Yiqi Wenyang Prescription (YQWYP, which consists of milkvetch root, tangshen, dried ginger, cassig twig, ephedra, biond magnolia flower-bud, Chinese magnoliavine fruit, earthworm, and liquorice root) on an allergic rhinitis (AR) murine model and the protective effect on the tight junction (TJ) key proteins zonula occludens-1 (ZO-1) and occludin and (ii) elucidate whether YQWYP exerts these effects by inhibiting autophagy in nasal mucosal cells.Methods Thirty C57BL/6 mice were randomly divided into six groups with 5 mice per group: (i) the blank group, (ii) the model group, (iii-v) the YQWYP low-dose, mid-dose, and high-dose groups(7, 14, 28 g/kg), and (vi) the cetirizine group(1.667 mg/kg). The model was established by intraperitoneal injection and nasal stimulation of ovalbumin. 1 hour before the nasal stimulation, mice in the blank group or in the model group were given normal saline by gavage, mice in the YQWYP groups and those in the cetirizine group were given the corresponding medicines solution by gavage. After 7 days, mice behavior was scored. After that, the mice were sacrificed and the nasal mucosa tissues were harvested. The inflammatory reaction of the nasal mucosa was observed by HE staining, the proliferation of goblet cells in the nasal mucosa was observed by PAS staining, the IgE content in nasal lavage fluid was determined by ELISA, the expression levels of ZO-1 and occludin were analyzed by immunohistochemistry, and the expression levels of LC3B, P62, and Beclin1 in the nasal mucosa of the blank group, model group, and YQWYP high-dose group were analyzed by Western blotting.Results After the successful establishment of the AR model, compared with the blank group, the symptom scores of nose scratching, sneezing, and runny nose in the model group were higher, while the total scores was significantly higher(P<0.01). In the model group, the nasal mucosal epithelium was disrupted and destroyed, a large number of inflammatory cells were infiltrated, goblet cells showed hyperplasia, mucus production was increased, mucosal swelling was obvious, the amount of IgE in nasal lavage fluid was increased (P<0.01). The protein expression levels of ZO-1 and occludin were decreased (P<0.05), the protein expression levels of LC3BⅡ/Ⅰ and Beclin1 were increased (P<0.05), P62 protein expression was decreased (P<0.05). After medication intervention, compared with the model group, in the YQWYP high-dose group and the cetirizine group, the total score were reduced (P<0.01), the swelling of the nasal mucosa was reduced, the infiltration of inflammatory cells was inhibited, the number of goblet cells was decreased, the amount of IgE in nasal lavage fluid was reduced(P<0.01), the protein expression of ZO-1 and occludin were increased (P<0.05), the protein levels of LC3BII/I and Beclin1 were decreased (P<0.05), P62 protein expression was increased (P<0.05). Conclusion YQWYP has a good therapeutic effect on AR mice, and its mechanism may be related to the promotion of nasal mucosal repair by inhibiting autophagy of nasal mucosal cells.
3.Medicine+information: Exploring patent applications in precision therapy in cardiac surgery
Zhengjie WANG ; Qi TONG ; Tao LI ; Nuoyangfan LEI ; Yiwen ZHANG ; Huanxu SHI ; Yiren SUN ; Jie CAI ; Ziqi YANG ; Qiyue XU ; Fan PAN ; Qijun ZHAO ; Yongjun QIAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(09):1246-1250
Currently, in precision cardiac surgery, there are still some pressing issues that need to be addressed. For example, cardiopulmonary bypass remains a critical factor in precise surgical treatment, and many core aspects still rely on the experience and subjective judgment of cardiopulmonary bypass specialists and surgeons, lacking precise data feedback. With the increasing elderly population and rising surgical complexity, precise feedback during cardiopulmonary bypass becomes crucial for improving surgical success rates and facilitating high-complexity procedures. Overcoming these key challenges requires not only a solid medical background but also close collaboration among multiple interdisciplinary fields. Establishing a multidisciplinary team encompassing professionals from the medical, information, software, and related industries can provide high-quality solutions to these challenges. This article shows several patents from a collaborative medical and electronic information team, illustrating how to identify unresolved technical issues and find corresponding solutions in the field of precision cardiac surgery while sharing experiences in applying for invention patents.
4.Prediction and risk factors of recurrence of atrial fibrillation in patients with valvular diseases after radiofrequency ablation based on machine learning
Huanxu SHI ; Peiyu HE ; Qi TONG ; Zhengjie WANG ; Tao LI ; Yongjun QIAN ; Qijun ZHAO ; Fan PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(07):840-847
bjective To use machine learning technology to predict the recurrence of atrial fibrillation (AF) after radiofrequency ablation, and try to find the risk factors affecting postoperative recurrence. Methods A total of 300 patients with valvular AF who underwent radiofrequency ablation in West China Hospital and its branch (Shangjin Hospital) from January 2017 to January 2021 were enrolled, including 129 males and 171 females with a mean age of 52.56 years. We built 5 machine learning models to predict AF recurrence, combined the 3 best performing models into a voting classifier, and made prediction again. Finally, risk factor analysis was performed using the SHApley Additive exPlanations method. Results The voting classifier yielded a prediction accuracy rate of 75.0%, a recall rate of 61.0%, and an area under the receiver operating characteristic curve of 0.79. In addition, factors such as left atrial diameter, ejection fraction, and right atrial diameter were found to have an influence on postoperative recurrence. Conclusion Machine learning-based prediction of recurrence of valvular AF after radiofrequency ablation can provide a certain reference for the clinical diagnosis of AF, and reduce the risk to patients due to ineffective ablation. According to the risk factors found in the study, it can provide patients with more personalized treatment.
5.Percutaneous screw fixation assisted by an orthopedic robot for pelvic and acetabular fractures
Shi HONG ; Zhengjie WU ; Xue LI ; Yuanrong CHEN ; Xiaokang CHEN ; Bo PENG
Chinese Journal of Orthopaedic Trauma 2019;21(1):16-21
Objective To analyze the effectiveness and safety of percutaneous screw fixation assisted by an orthopedic robot for treatment of pelvic and acetabular fractures.Methods Fifteen patients with fresh closed pelvic or acetabular fracture were hospitalized from September to December 2017 at Department of Orthopaedics,Foshan Hospital of Traditional Chinese Medicine.They were 10 men and 5 women,from 22 to 69 years of age (average,65.2 years).There were 9 pelvic fractures (5 cases of Tile type B and 4 ones of Tile type C) and 6 acetabular fractures (3 anterior column fractures,2 posterior column fractures and one transverse fracture).All patients underwent percutaneous transpedicular screw fixation with the assistance of an orthopaedic robot.Fluoroscopic frequency,number of guide needle adjustment and deviation between initial planning and the final screw position were recorded intraoperatively.Postoperative CT was performed to evaluate screw positions and incidence of adverse events.Functional recovery in the patients was evaluated in regular follow-ups.Results A total of 26 screws were implanted in the operation.The fluoroscopic frequency ranged from 12 to 49 times,with a mean value of 17.3 times per screw;the number of needle adjustment ranged from 0 to 2 times(mean,0.3 times);the deviation of the actual path from its initial planning ranged from 0.82 to 1.42 mm (mean,1.06 mm).No surgery-related neurovascular injury occurred in any patient.Postoperative CT examination revealed that no screws cut out of cortical bone,yielding a 100% rate of excellent and good screw positions.Two patients were lost to the follow-up,and the remaining 13 patients were followed up for 12 to 14 months (mean,12.6 months).Their Majeed functional scores at the final follow-up averaged 88.6 points (from 68 to 96 points).No neurological symptoms were observed during follow-up.Conclusion Since percutaneous screw fixation assisted by an orthopaedic robot is accurate and safe and needs less fluoroscopic frequency,it will became a major minimally invasive surgical technique for pelvic and acetabular fractures.
7.Optimization of the Extraction Technology of Zishen Yangyin Granules by Orthogonal Experiment
Zhanli CHEN ; Aiping SUN ; Runbo SHI ; Zhiyao LI ; Xuejun WEI ; Zhengjie LI
China Pharmacy 2005;0(15):-
OBJECTIVE:To optimize the extraction technology of Zishen yangyin granules.METHODS:The yield of the extractum and the content of the extraction using 80% alcohol as solvent were used as indexes to optimize the extraction technology of Zishen yangyin granules by orthogonal experiment with the times of extraction,the extraction time and the amount of water added as factors.RESULTS:The optimal extraction conditions were as follows:the extraction was carried out for 3 times by adding water at an amount of 9 times,6 times and 6 times,respectively that of solid substance with decoction time of 3 h,2 h and 1 h,respectively.CONCLUSION:The optimal extraction process was proved to be time-saving and energy-saving and suitable for large production.

Result Analysis