1.A Comparative Study on the Clinical Effects of Short-term and Long-term Spinal Cord Stimulation in Patients with Prolonged Disorders of Consciousness
Fengqiao SUN ; Hongchuan NIU ; Yi YANG ; Jianghong HE ; Yuanli ZHAO
Medical Journal of Peking Union Medical College Hospital 2025;16(2):307-313
To compare the therapeutic effects of short-term spinal cord stimulation (stSCS) and long-term spinal cord stimulation (ltSCS) on patients with prolonged disorders of consciousness(pDoC). Clinical data of patients with pDoC who underwent SCS surgery at Peking University International Hospital from January 2020 to December 2021 were retrospectively included. Patients were divided into the stSCS group and the ltSCS group based on the surgical approach. The Coma recovery scale-revised (CRS-R) was used to assess the level of consciousness before and 3 months after SCS treatment. Based on CRS-R scores, the clinical diagnosis of the patient's level of consciousenss was categorized into four levels: vegetative state, minimally conscious state minus (MCS-), MCS plus (MCS+), and emergence from the minimally conscious state(EMCS). Improvement in the clinical diagnostic level of consciousness was defined as effective treatment, and the therapeutic outcomes of the stSCS and ltSCS groups were compared. 44.8% of patients with pDoC showed improvement in their clinical diagnostic level of consciousness after SCS treatment. Compared to preoperative scores, the CRS-R scores at 3 months postoperatively were significantly increased in both the stSCS and ltSCS groups (both Both stSCS and ltSCS can significantly improve the level of consciousness in patients with pDoC. Compared to ltSCS, stSCS may achieve comparable short-term therapeutic outcomes.
2.Development status analysis and suggestions of TCM pharmacists in Chinese public TCM hospitals
Baojuan XUE ; Ning WU ; Yang ZHAO ; Junshu GE ; Yi WANG ; Zheyuan LIU ; Zhaoheng YANG ; Ying SUN
China Pharmacy 2025;36(8):903-907
OBJECTIVE To understand the development status and existing problems of traditional Chinese medicine(TCM) pharmacists in public TCM hospitals in China, aiming to provide suggestions for the competent departments to formulate management policies for TCM pharmacists and promote the healthy development of TCM. METHODS The data on the number and professional titles of TCM pharmacists in public TCM hospitals in China from 2019 to 2023 were collected. Descriptive analysis was employed to analyze the number, distribution and professional titles of TCM pharmacists in public TCM hospitals across the country, and to measure the quantity shortfalls of the number of TCM pharmacists in these hospitals. RESULTS From 2019 to 2023, the number of TCM pharmacists in public TCM hospitals in China grew slowly, with an average annual growth rate of 2.56%. However, the proportion of TCM pharmacists to the total number of pharmacists in public TCM hospitals gradually decreased, with an average annual growth rate of -0.65%. In terms of hospital grades, the number of TCM pharmacists in tertiary public TCM hospitals showed positive growth, while those in secondary and primary public TCM hospitals showed negative growth. In terms of hospital types, the average annual growth rate of TCM pharmacists in TCM hospitals was 2.22%, in integrated Chinese and Western medicine hospitals it was 7.97%, and in ethnic minority medicine hospitals it was 2.74%. The development of TCM pharmacists in different provinces was uneven. The annual growth rate of TCM pharmacists in Guizhou exceeded 10%, while the growth rate in Hunan and Heilongjiang was negative. In 2023, the number of TCM pharmacists per thousand population in public TCM hospitals was 0.03, indicating a relatively low staffing level. The professional titles of TCM pharmacists in public TCM hospitals were mainly primary and E-mail:601907549@qq.com intermediate, with a total of 67.33%. According to the calculation that the proportion of TCM pharmacists to pharmacists was not less than 60%, public TCM hospitals and hospitals of integrated TCM and Western medicine should be reconfigured with TCM pharmacists 6 212 and 1 288 people, respectively. CONCLUSIONS The number of TCM pharmacists in public TCM hospitals is growing slowly, with insufficient staffing levels, relatively low professional titles, and uneven distribution and development across provinces. It is suggested that relevant competent departments strengthen policy guidance, increase the attention given by the state level to TCM pharmacists, strengthen the construction of the talent team for TCM pharmacists, improve the quality and optimize the allocation of TCM pharmacist talents in order to promote the high-quality development of TCM services.
3.Research on BP Neural Network Method for Identifying Cell Suspension Concentration Based on GHz Electrochemical Impedance Spectroscopy
An ZHANG ; A-Long TAO ; Qi-Hang RAN ; Xia-Yi LIU ; Zhi-Long WANG ; Bo SUN ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2025;52(5):1302-1312
ObjectiveThe rapid advancement of bioanalytical technologies has heightened the demand for high-throughput, label-free, and real-time cellular analysis. Electrochemical impedance spectroscopy (EIS) operating in the GHz frequency range (GHz-EIS) has emerged as a promising tool for characterizing cell suspensions due to its ability to rapidly and non-invasively capture the dielectric properties of cells and their microenvironment. Although GHz-EIS enables rapid and label-free detection of cell suspensions, significant challenges remain in interpreting GHz impedance data for complex samples, limiting the broader application of this technique in cellular research. To address these challenges, this study presents a novel method that integrates GHz-EIS with deep learning algorithms, aiming to improve the precision of cell suspension concentration identification and quantification. This method provides a more efficient and accurate solution for the analysis of GHz impedance data. MethodsThe proposed method comprises two key components: dielectric property dataset construction and backpropagation (BP) neural network modeling. Yeast cell suspensions at varying concentrations were prepared and separately introduced into a coaxial sensor for impedance measurement. The dielectric properties of these suspensions were extracted using a GHz-EIS dielectric property extraction method applied to the measured impedance data. A dielectric properties dataset incorporating concentration labels was subsequently established and divided into training and testing subsets. A BP neural network model employing specific activation functions (ReLU and Leaky ReLU) was then designed. The model was trained and tested using the constructed dataset, and optimal model parameters were obtained through this process. This BP neural network enables automated extraction and analytical processing of dielectric properties, facilitating precise recognition of cell suspension concentrations through data-driven training. ResultsThrough comparative analysis with conventional centrifugal methods, the recognized concentration values of cell suspensions showed high consistency, with relative errors consistently below 5%. Notably, high-concentration samples exhibited even smaller deviations, further validating the precision and reliability of the proposed methodology. To benchmark the recognition performance against different algorithms, two typical approaches—support vector machines (SVM) and K-nearest neighbor (KNN)—were selected for comparison. The proposed method demonstrated superior performance in quantifying cell concentrations. Specifically, the BP neural network achieved a mean absolute percentage error (MAPE) of 2.06% and an R² value of 0.997 across the entire concentration range, demonstrating both high predictive accuracy and excellent model fit. ConclusionThis study demonstrates that the proposed method enables accurate and rapid determination of unknown sample concentrations. By combining GHz-EIS with BP neural network algorithms, efficient identification of cell concentrations is achieved, laying the foundation for the development of a convenient online cell analysis platform and showing significant application prospects. Compared to typical recognition approaches, the proposed method exhibits superior capabilities in recognizing cell suspension concentrations. Furthermore, this methodology not only accelerates research in cell biology and precision medicine but also paves the way for future EIS biosensors capable of intelligent, adaptive analysis in dynamic biological research.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Clinical efficacy of valve surgery for infective endocarditis in 343 patients: A retrospective study in a single center
Shuanglei ZHAO ; Zhou LIU ; Bin WANG ; Zhaoqing SUN ; Mingxiu WEN ; Qianxian LI ; Yi HU ; Wenjian JIANG ; Jie HAN ; Jiangang WANG ; Ming GONG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1133-1139
Objective To analyze the clinical efficacy of valve surgeries for infective endocarditis and the affecting factors, and compare the early- and long-term postoperative outcomes of different surgery approaches. Methods The patients with infective endocarditis who underwent valve replacement/valvuloplasty in our hospital from 2010 to 2022 were retrospectively collected. The clinical data of the patients were analyzed. Results A total of 343 patients were enrolled, including 197 patients with mechanical valve replacement, 62 patients with bioprosthetic valve replacement, and 84 patients with valvuloplasty. There were 238 males and 105 females with an average age of (44.2±14.8) years. Single-valve endocarditis was present in 200 (58.3%) patients, and multivalve involvement was present in 143 (41.7%) patients. Sixty (17.5%) patients had suffered thrombosis before surgery, including cerebral embolisms in 32 patients. The mean follow-up time was (60.6±43.8) months. Early mortality within one month after the surgery occurred in 17 (5.0%) patients, while later mortality occurred in 19 (5.5%) patients. Eight (2.3%) patients underwent postoperative dialysis, 13 (3.8%) patients suffered postoperative stroke, 6 patients underwent reoperation, and 3 patients suffered recurrence of infective endocarditis. Smoking (P=0.002), preoperative embolisms (P=0.001), duration of surgery (P=0.001), and postoperative dialysis (P=0.001) were risk factors for early mortality, and left ventricular ejection fraction ≥60% (P=0.022) was protective factor for early mortality. New York Heart Association classification Ⅲ-Ⅳ (P=0.010) and ≥3 valve procedures (P=0.028) were risk factors for late mortality. The rate of composite endpoint events was significantly lower in the valvuloplasty group than that in the valve replacement group. Conclusion For patients with infective endocarditis, smoking and preoperative embolisms are associated with high postoperative mortality, multiple-valve surgery is associated with a poorer prognosis, and valvuloplasty has advantages over valve replacement and should be attempted in the surgical management of patients with infective endocarditis.
10.Modified Lianpoyin Formula Treats Hp-associated Gastritis by Regulating Mitochondrial Autophagy and NLRP3 Inflammasome Signaling Pathway
Siyi ZHANG ; Haopeng DANG ; Wenliang LYU ; Wentao ZHOU ; Wei GUO ; Lin LIU ; Lan ZENG ; Yujie SUN ; Luming LIANG ; Yi ZHAO
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(21):178-187
ObjectiveTo explore the effect of modified Lianpoyin formula (LPYJWF) in the treatment of Helicobacter pylori (Hp)-associated gastric mucosal damage based on mitochondrial autophagy and NLRP3 inflammasome signaling pathway. MethodsA total of 60 eight-week-old Balb/c male mice were assigned via the random number table method into control, model, high-dose LPYJWF (LPYJWF-H, 27.3 g·kg-1·d-1), medium-dose LPYJWF (LPYJWF-M, 13.65 g·kg-1·d-1), low-dose LPYJWF (LPYJWF-L, 6.83 g·kg-1·d-1), and quadruple therapy groups. Except the control group, other groups were modeled for Hp infection. Mice were administrated with LPYJWF at corresponding doses by gavage. Quadruple therapy group was given omeprazole (6.06 mg·kg-1·d-1) + amoxicillin (303 mg·kg-1·d-1) + clarithromycin (151.67 mg·kg-1·d-1) + colloidal pectin capsules (30.3 mg·kg-1·d-1) by gavage. The control group was given an equal volume of 0.9% NaCl for 14 days. Hematoxylin-eosin (HE) staining was used to observe the pathological changes of gastric mucosa, and Warthin-Starry (W-S) silver staining was used to detect Hp colonization. Transmission electron microscopy was employed to observe the mitochondrial ultrastructure of the gastric tissue, and immunofluorescence co-localization assay was adopted to detect the expression of mitochondrial transcription factor A (TFAM) and translocase of the outer mitochondrial membrane member 20 (TOMM20). The water-soluble tetrazolium salt method and thiobarbituric acid method were used to determine the levels of superoxide dismutase (SOD) and malondialdehyde (MDA), respectively, in the gastric tissue. Western blot was employed to measure the protein levels of PTEN-induced kinase 1 (PINK1), Parkin, p62, microtubule-associated protein 1 light chain 3 (LC3), NOD-like receptor protein 3 (NLRP3), apoptosis-associated speck-like protein containing a CARD (ASC), interleukin-1β (IL-1β), and interleukin-18 (IL-18). Real-time quantitative PCR was employed to assess the mRNA levels of PINK1, Parkin, p62, and LC3. ResultsCompared with the control group, the model group presented obvious gastric mucosal damage, colonization of a large number of Hp, severe mitochondrial damage, vacuolated structures due to excessive autophagy, reduced TOMM20 and TFAM co-expression in the gastric mucosal tissue, and reduced SOD and increased MDA (P<0.01). In addition, the gastric tissue in the model group showed up-regulated protein and mRNA levels of PINK1, Parkin, and LC3 and down-regulated protein and mRNA levels of p62 (P<0.01, as well as increased expression of inflammasome-associated proteins NLRP3, ASC, IL-1β, and IL-18 (P<0.01). Compared with the model group, the LPYJWF and quadruple therapy groups showed alleviated pathological damage of gastric mucosa, reduced Hp colonization, mitigated mitochondrial damage, and increased co-expression of TOMM20 and TFAM. The SOD level was elevated in the LPYJWF-L group (P<0.01), and the MDA levels became lowered in the LPYJWF and quadruple therapy groups (P<0.05, P<0.01). Furthermore, the LPYJWF and quadruple therapy groups showed down-regulated mRNA levels of PINK1, Parkin, and LC3 and protein levels of PINK1 and Parkin, and up-regulated mRNA level of p62 (P<0.01). The LPYJWF-M, LPYJWF-H, and quadruple therapy groups showcased down-regulated LC3 Ⅱ/LC3 Ⅰ level (P<0.05, P<0.01) and up-regulated protein level of p62 (P<0.01). The expression of inflammasome-associated proteins NLRP3, ASC, IL-1β, and IL-18 were reduced in the LPYJWF and quadruple therapy groups (P<0.05, P<0.01). ConclusionLPYJWF ameliorates gastric mucosal damage and exerts mucosa-protective effects in Hp-infected mice, which may be related to the inhibition of excessive mitochondrial autophagy, thereby inhibiting the activation of the NLRP3 inflammasome pathway.

Result Analysis