1.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
2.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
3.Influencing factors and network analysis of aggressive behavior among Chinese college students based on propensity score matching
ZENG Rui, ZHAO Mengxiao, HU Mengmeng, LIU Xin, CHANG Hongjuan
Chinese Journal of School Health 2025;46(3):358-363
Objective:
To explore the influencing factors and network structure of aggressive behaviors among college students based on propensity score matching (PSM), so as to provide precise targeted interventions for the prevention and improvement of aggressive behaviors among college students.
Methods:
A total of 2 652 college students were selected by convenient sampling method from three colleges in Wuhan, Hubei Province in June 2023. Questionnaire surveys were carried out by using the Buss-Warren Aggression Questionnaire (BWAQ), Ruminative Responses Scale (RRS), Cognitive Emotion Regulation Questionnaire-Chinese Version (CERQ-C), Family APGAR Index (APGAR) ,Brief Fear of Negative Evaluation Scale (BFNES).By bias score matching (PSM) for 1∶1 matching, univariate and multivariate Logistic regression analysis, and network analysis were conducted on the college students.
Results:
College students with higher levels of ruminant thinking,non adaptive emotional regulation and fear of negative appraisal were more likely to have highly aggressive behaviors( OR =1.14,1.18,1.06),and those with higher adaptive emotional regulation and family care index were more likely to have highly aggressive behaviors ( OR =0.88,0.82)( P < 0.01 ). Network structure was significantly different between the two groups ( M =0.27, P <0.05). The core affective factors of college students with high levels of aggressive behavior were brooding reflective pondering and symptom rumination( EI =3.50, 3.49, 3.48 ),low aggressive behavior college students core affective factors were adaptive emotion regulation growth and non adaptive emotion regulation( EI =4.37, 4.12, 4.08).
Conclusion
Factors affecting Chinese college students aggressive behaviors are of different characteristics on different behaviour types, and targeted interventions should be adopted to reduce aggressive behaviors of college students.
4.Research on The Construction and Application of Multiple Fluorescence Amplification System for Three Kinds of Stains
Yi-Fan BAI ; He-Miao ZHAO ; Jing CHEN ; Hong-Di LIU ; Rui-Qin YANG ; Chong WANG
Progress in Biochemistry and Biophysics 2025;52(4):982-994
ObjectiveA multiplex amplification system was constructed based on the capillary electrophoresis platform for simultaneous detection of saliva, semen, and vaginal secretions using tissue-specific RNA markers. The aim of this study is to identify the tissue origin of suspicious body fluid stains found at crime scenes and determine whether the body fluid stains at the crime scene are one or several types among saliva, semen, and vaginal secretions. MethodsThirty saliva samples, forty semen samples, and forty vaginal secretion samples (half from 2015 and half from 2024) were collected from healthy adult volunteers. Through primer designing, system formulation, and PCR condition optimization, a multiplex fluorescent amplification system was constructed. The specificity, sensitivity, and detection ability for mixed samples of this system were investigated, and it was tested using real crime scene materials. In the primer design stage, to reduce the requirements for RNA template quality, the amplification products were set within 80-300 bp. In the system formulation stage, dominant and subordinate primers were mainly considered. By reducing the concentration of dominant primers and increasing that of subordinate primers, a capillary electrophoresis spectrum with an appropriate peak height ratio was finally obtained. Additionally, gradient experiments were designed to adjust the concentrations of PCR reagents and PCR amplification conditions, and multiple versions of DNA amplification enzymes were optimized to achieve the best experimental results. ResultsThrough statistical analysis, there was no significant difference in the capillary electrophoresis of the 3 types of body fluid samples from the two years (2015 and 2024), demonstrating that the sample preservation method in this study can preserve samples for a relatively long time. The composite amplification system constructed in this study exhibited high specificity for all 3 types of body fluid, with no cross-reactions between the markers of each type of body fluid. The minimum detection thresholds for the 3 types of body fluid reached 0.002 9, 0.001 5, and 0.42 mg/L, respectively. This system also had a high degree of discrimination for mixed samples, especially for semen-saliva mixtures, where each body fluid marker could still be successfully detected when the concentration ratio of semen to saliva was 100:1. Meanwhile, in the two actual cases presented in this article, the application of this composite amplification system performed outstandingly. ConclusionThe composite amplification detection system constructed in this study can achieve the correct screening of saliva, semen, and vaginal secretions, overcoming the problems such as low specificity and sensitivity of marker tests and unbalanced RFU values of each marker in previous studies. The specificity and sensitivity meet the practical work requirements, and the operation is simple. It provides an analytical and identification method for body fluid stains in actual case and is applicable to the identification of the tissue origin of biological evidence at crime scenes involving sexual assault, indecent assault, and other criminal acts. In the future, more types of body fluid markers will be screened to expand the types of body fluids detected by the system, and body fluid-specific cSNP and cInDel genetic markers will be introduced to infer the sources (individuals and types) of mixed and complex stains more accurately.
5.A case-control study on the association of Hashimoto’s thyroiditis and anti-thyroid antibodies with oral lichen planus
LIU Yuan ; CHEN Yan ; CONG Zhaoxia ; LI Yiming ; XUE Rui ; ZHAO Jin
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(9):757-764
Objective:
This study aims to explore the association between oral lichen planus (OLP) and Hashimoto’s thyroiditis (HT) and its anti-thyroid antibodies to provide clinical evidence for thyroid disease screening in patients with OLP.
Methods:
This study was approved by the institutional ethics committee. A total of 125 clinically and histopathologically confirmed patients with OLP were enrolled as the case group, and they were matched with 125 non-OLP controls based on sex and age. Demographic data (gender, age, lesion type, and disease duration) were collected from both groups. Serum levels of thyroid peroxidase antibodies (TPOAb) and thyroglobulin antibodies (TgAb) were measured to analyze their associations with sex, age, lesion type, and disease duration in patients with OLP.
Result:
The prevalence of HT in patients with OLP was 31.20%, significantly higher than that in the control group (9.60%) (χ2=18.504, P<0.001). The prevalence of HT in female patients with OLP (39.13%) was significantly higher than that in male patients (9.09%)(χ2=10.93,P<0.001). The positivity rate of thyroid peroxidase antibodies (TPOAb) in patients with OLP (17.6%) was significantly higher than in the control group (4.0%) (χ2=10.989, P<0.001). The TPOAb positivity rate was significantly higher in female patients (22.83%) than in male patients (3.03%) (χ2=5.210, P=0.014). There was no statistically significant difference in the positivity rate of TgAb between patients with OLP (7.2%) and the control group (3.2%) (P>0.05). Patients with erosive lesions had a significantly higher TPOAb positivity rate (25.0%, 17/68) compared to those with non-erosive lesions (8.77%, 5/57), and the difference was statistically significant (χ2=4.831, P=0.028). Logistic regression analysis revealed that female patients with OLP had an 8.935-fold higher risk of being TPOAb positive compared to males (OR=8.935, 95%CI: 1.134-70.388, P=0.038). Patients with erosive OLP lesions had a 3.199-fold higher risk of TPOAb positivity compared to those with non-erosive lesions (OR=3.199, 95%CI: 1.064-9.618, P=0.038).
Conclusion
The prevalence of HT is higher in patients with OLP, with higher positivity rates of anti-thyroid antibodies observed in female patients and those with erosive OLP lesions. This suggests that thyroid disease screening should be incorporated into the clinical management of patients with OLP, especially for women and patients who present with erosive lesions.
6.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
7.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
8.Research on Regulatory Mechanism of Verbenalin on HCoV-229E-infected Macrophage Injury Based on Mitophagy
Qiyue SUN ; Lei BAO ; Zihan GENG ; Ronghua ZHAO ; Shuran LI ; Xihe CUI ; Jingsheng ZHANG ; Xian LIU ; Rui XIE ; Xiaolan CUI ; Shanshan GUO ; Jing SUN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(21):29-37
ObjectiveTo investigate the protective effect and mechanism of verbenalin on mouse mononuclear macrophage leukemia cells (RAW264.7) damaged by human coronavirus (HCoV)-229E infection, thereby providing experimental evidence for its development and application. MethodsRAW264.7 macrophages were infected with different concentrations of HCoV-229E to establish a coronavirus-induced macrophage injury model using the cell counting kit-8 (CCK-8) assay for assessing cell proliferation and viability. Cells were randomly divided into four groups: normal control, verbenalin group (125 μmol·L-1), model group (HCoV-229E), and HCoV-229E + verbenalin group (HCoV-229E + 125 μmol·L-1 verbenalin). Cell viability was measured using the CCK-8 assay, and the maximum non-toxic concentration (CC0), half-maximal cytotoxic concentration (CC50), half-maximal effective concentration (EC50), and selectivity index (SI) of verbenalin were calculated. Calcein/PI double staining was used to assess cell viability and cytotoxicity, and JC-1 staining was applied to evaluate changes in mitochondrial membrane potential (MMP). mito-Keima adenovirus labeling was used to assess mitophagy levels in each group. ResultsA macrophage infection model was successfully established by infecting RAW264.7 cells with the original concentration of HCoV-229E for 36 h. The CC0 of verbenalin was 125 μmol·L-1. The CC50 was 448.25 μmol·L-1. The EC50 against HCoV-229E-infected cells was 46.28 μmol·L-1, and the SI was 9.68. Compared with the normal group, the model group showed significantly reduced cell survival rate (P<0.01), increased cell death rate (P<0.01), decreased MMP (P<0.01), and suppressed mitophagy (P<0.01). In contrast, verbenalin treatment significantly improved cell survival rate (P<0.01), reduced cell death rate (P<0.01), alleviated MMP loss (P<0.01), and enhanced mitophagy levels (P<0.01) compared with the model group. ConclusionVerbenalin can enhance the survival rate of macrophages following HCoV-229E infection. The underlying mechanism may be associated with the activation of mitophagy, maintenance of MMP stability, and alleviation of mitochondrial damage.
9.Research on Regulatory Mechanism of Verbenalin on HCoV-229E-infected Macrophage Injury Based on Mitophagy
Qiyue SUN ; Lei BAO ; Zihan GENG ; Ronghua ZHAO ; Shuran LI ; Xihe CUI ; Jingsheng ZHANG ; Xian LIU ; Rui XIE ; Xiaolan CUI ; Shanshan GUO ; Jing SUN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(21):29-37
ObjectiveTo investigate the protective effect and mechanism of verbenalin on mouse mononuclear macrophage leukemia cells (RAW264.7) damaged by human coronavirus (HCoV)-229E infection, thereby providing experimental evidence for its development and application. MethodsRAW264.7 macrophages were infected with different concentrations of HCoV-229E to establish a coronavirus-induced macrophage injury model using the cell counting kit-8 (CCK-8) assay for assessing cell proliferation and viability. Cells were randomly divided into four groups: normal control, verbenalin group (125 μmol·L-1), model group (HCoV-229E), and HCoV-229E + verbenalin group (HCoV-229E + 125 μmol·L-1 verbenalin). Cell viability was measured using the CCK-8 assay, and the maximum non-toxic concentration (CC0), half-maximal cytotoxic concentration (CC50), half-maximal effective concentration (EC50), and selectivity index (SI) of verbenalin were calculated. Calcein/PI double staining was used to assess cell viability and cytotoxicity, and JC-1 staining was applied to evaluate changes in mitochondrial membrane potential (MMP). mito-Keima adenovirus labeling was used to assess mitophagy levels in each group. ResultsA macrophage infection model was successfully established by infecting RAW264.7 cells with the original concentration of HCoV-229E for 36 h. The CC0 of verbenalin was 125 μmol·L-1. The CC50 was 448.25 μmol·L-1. The EC50 against HCoV-229E-infected cells was 46.28 μmol·L-1, and the SI was 9.68. Compared with the normal group, the model group showed significantly reduced cell survival rate (P<0.01), increased cell death rate (P<0.01), decreased MMP (P<0.01), and suppressed mitophagy (P<0.01). In contrast, verbenalin treatment significantly improved cell survival rate (P<0.01), reduced cell death rate (P<0.01), alleviated MMP loss (P<0.01), and enhanced mitophagy levels (P<0.01) compared with the model group. ConclusionVerbenalin can enhance the survival rate of macrophages following HCoV-229E infection. The underlying mechanism may be associated with the activation of mitophagy, maintenance of MMP stability, and alleviation of mitochondrial damage.
10.Identification, expression and protein interaction analysis of Aux/IAA and ARF gene family in Senna tora L.
Zhao FENG ; Shi-peng LIU ; Rui-hua LÜ ; Rui-hua LÜ ; Xiao-chen HU ; Ming-ying ZHANG ; Ren-jun MAO ; Gang ZHANG
Acta Pharmaceutica Sinica 2024;59(3):751-763
The early response of plant auxin gene family


Result Analysis
Print
Save
E-mail