1.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
2.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
3.Advances in oral distant targeted nanodelivery systems
Min SUN ; Chuan-sheng HUANG ; Li-ping WANG ; Xu-li RUAN ; Yun-li ZHAO ; Xin-chun WANG
Acta Pharmaceutica Sinica 2025;60(1):72-81
Due to patient compliance and convenience, oral medication is likely the most common and acceptable method of drug administration. However, traditional dosage forms such as tablets or capsules may lead to low drug bioavailability and poor therapeutic efficiency. Therefore, with advancements in material science and micro/nano manufacturing technology, various carriers have been developed to enhance drug absorption in the gastrointestinal tract. In this context, we initially discuss the key biological factors that hinder drug transport and absorption (including anatomical, physical, and biological factors). Building on this foundation, recent progress in both conventional and innovative oral drug delivery routes aimed at improving drug bioavailability and targeting is reviewed. Finally, we explore future prospects for oral drug delivery systems as well as potential challenges in clinical translation.
4.Theoretical Framework and Implementation Strategies for the Modernization of Traditional Chinese Medicine Governance System Modernization:Based on Constructivist Grounded Theory
Heling AI ; Ping HUANG ; Hailei ZHAO
Journal of Traditional Chinese Medicine 2025;66(15):1553-1558
The modernization of the governance system for traditional Chinese medicine (TCM) constitutes the institutional cornerstone for advancing the high-quality development of the TCM sector in China. Drawing on focus group discussions with TCM administrative leaders, experts, and scholars who examined the connotations, implementation pathways, problems, and challenges associated with the modernization of TCM governance and governance capacity, this study employed a constructivist grounded theory methodology. Through systematic procedures including initial coding, focused coding, axial coding, and theoretical coding, the study develops a theoretical framework for the modernization of the TCM governance system, with "governance goals - governance philosophy - collaborative governance - institutional systems" as the core. Building upon this framework, the study proposes several implementation strategies for modernizing TCM governance system, such as prioritizing people's health, fostering cultural confidence in TCM, enhancing multi-stakeholder collaboration, and comprehensively improving the institutional architecture of TCM. These findings offer theoretical insights to support the advancement of a modernized TCM governance system.
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Association between urinary metal levels and kidney stones in metal smelter workers
Yiqi HUANG ; Jiazhen ZHOU ; Yaotang DENG ; Guoliang LI ; Zhiqiang ZHAO ; Jiayi OU ; Shuirong HE ; Hecheng LI ; Xinhua LI ; Ping CHEN ; Lili LIU
Journal of Environmental and Occupational Medicine 2024;41(7):735-743
Background Arsenic, cobalt, barium, and other individual metal exposure have been confirmed to be associated with the incidence of kidney stones. However, there are few studies on the association between mixed metal exposure and kidney stones, especially in occupational groups. Objective To investigate the association between mixed metal exposure and kidney stones in an occupational population from a metal smelting plant. Methods A questionnaire survey was conducted to collect sociodemographic characteristics, medical history, and lifestyle information of
8.Based on supramolecular chemistry to explore the scientific connotation of predecocting gypsum in Maxingshigan decoction preliminarily
Yao-zhi ZHANG ; Shu-chang YAO ; Lu-ping YANG ; Yi-hang ZHAO ; An-qi XU ; Xue-mei HUANG ; Peng-long WANG
Acta Pharmaceutica Sinica 2024;59(6):1828-1840
It has gradually become a consensus in the industry that the traditional Chinese medicine gypsum should be decocted first, but the understanding of decocting method is not completely unified in the works of doctors since ancient times, and there are occasional disputes about whether it is necessary to decocting first. In this study, the phase determination, physical and chemical characterization, qualitative and quantitative analysis of inorganic and organic components of the decoctions of herbal pairs and the whole prescription Maxingshigan decoction with gypsum as the center, and the pre-decoctions and co-decoctions of them were carried out to explore the scientific connotation of the pre-decoctions of gypsum. Results show that decoction phases were different between the co-decoctions and pre-decoctions of licorice-gypsum (Gancao-Shigao, GC-SG), ephedra-gypsum (Mahuang-Shigao, MH-SG) and almond-gypsum (Xingren-Shigao, XR-SG). The results of the micromorphology, particle size and zeta potential of herbal pairs and prescription (Quanfang, QF) showed that the supramolecular particles in pre-decoctions were smaller, more uniform and more stable than the co-decoctions. The results of organic components analysis showed that different cooking methods did not change the organic composition and content. ICP-OES results showed that the content of inorganic components in pre-decoctions was higher than in co-decoctions for the same boiling time of gypsum. The IR results showed that the pre-decoctions had stronger chemical functional group effect than the co-decoctions. To sum up, compared with the co-decoction, the pre-decoction of gypsum has different phase state and chemical composition interaction, and the difference of inorganic composition is an important material basis affecting the change of phase state compared with the co-decoction. It indicates that the material basis of traditional Chinese medicine decoction is indeed different whether gypsum is decocted first or not, which can provide a basis for the clinical application of decocted gypsum.
9.Efficacy and safety of oliceridine for treatment of moderate to severe pain after surgery with general anesthesia: a prospective, randomized, double-blinded, multicenter, positive-controlled clinical trial
Gong CHEN ; Wen OUYANG ; Ruping DAI ; Xiaoling HU ; Huajing GUO ; Haitao JIANG ; Zhi-Ping WANG ; Xiaoqing CHAI ; Chunhui WANG ; Zhongyuan XIA ; Ailin LUO ; Qiang WANG ; Ruifeng ZENG ; Yanjuan HUANG ; Zhibin ZHAO ; Saiying WANG
Chinese Journal of Anesthesiology 2024;44(2):135-139
Objective:To evaluate the efficacy and safety of oliceridine for treatment of moderate to severe pain after surgery with general anesthesia in patients.Methods:The patients with moderate to severe pain (numeric pain rating scale ≥4) after abdominal surgery with general anesthesia from 14 hospitals between July 6, 2021 and November 9, 2021 were included in this study. The patients were assigned to either experiment group or control group using a random number table method. Experiment group received oliceridine, while control group received morphine, and both groups were treated with a loading dose plus patient-controlled analgesia and supplemental doses for 24 h. The primary efficacy endpoint was the drug response rate within 24 h after giving the loading dose. Secondary efficacy endpoints included early (within 1 h after giving the loading dose) drug response rates and use of rescue medication. Safety endpoints encompassed the development of respiratory depression and other adverse reactions during treatment.Results:After randomization, both the full analysis set and safety analysis set comprised 180 cases, with 92 in experiment group and 88 in control group. The per-protocol set included 170 cases, with 86 in experiment group and 84 in control group. There were no statistically significant differences between the two groups in 24-h drug response rates, rescue analgesia rates, respiratory depression, and incidence of other adverse reactions ( P>0.05). The analysis of full analysis set showed that the experiment group had a higher drug response rate at 5-30 min after giving the loading dose compared to control group ( P<0.05). The per-protocol set analysis indicated that experiment group had a higher drug response rate at 5-15 min after giving the loading dose than control group ( P<0.05). Conclusions:When used for treatment of moderate to severe pain after surgery with general anesthesia in patients, oliceridine provides comparable analgesic efficacy to morphine, with a faster onset.
10.Research Progress of IL-13 Regulating Mucus Hypersecretion in Allergic Rhinitis and the Intervention of Traditional Chinese Medicine
ZHAO Yue ; WANG Zhiwang ; HUANG Keting ; LIANG Keke ; QUAN Ping ; ZHANG Yue
Chinese Journal of Modern Applied Pharmacy 2024;41(13):1836-1843
Allergic rhinitis(AR) is an allergic inflammatory disease of the nasal mucosa in which the immune inflammatory response alters the local microenvironment of the nasal mucosa, causing mucus hypersecretion as one of the main pathological features of AR. Interleukin-13(IL-13) is the main inflammatory factor secreted by Th2 cells, it can be involved in AR mucus hypersecretion process by regulating Goblet cell proliferation and Mucin 5ac expression through various signaling pathways. Traditional Chinese medicine has obvious advantages in the treatment of AR and its mucus hypersecretion, while the IL-13-mediated signaling pathways are one of the important mechanisms in treating AR mucus hypersecretion. This article reviews the regulation of IL-13-mediated signaling pathways on AR mucus hypersecretion and the intervention effects of traditional Chinese medicine, which providing a theoretical basis for experimental research and new drug development in AR mucus hypersecretion.


Result Analysis
Print
Save
E-mail