1.Correlation between insomnia,gastrointestinal symptoms,and glycated hemoglobin in patients with type 2 diabetes:a cross-sectional study based on the co-management platform of three disciplines of diabetes
Bo LI ; Qi YUAN ; Yongfa WANG ; Youjian FENG ; Guimiao WANG ; Weidong NIAN ; Yi ZHOU ; Tianchi HU ; Sisi MA ; Liyan JIA ; Zhihai ZHANG ; Jin LI ; Bing YAN ; Nengjiang ZHAO ; Shuyu YANG
Journal of Beijing University of Traditional Chinese Medicine 2024;47(7):989-997
		                        		
		                        			
		                        			Objective To investigate the relationship between insomnia,gastrointestinal symptoms,and glycosylated hemoglobin(HbA1c)levels in individuals diagnosed with type 2 diabetes mellitus(T2DM),as well as the related influencing factors.Methods A total of 910 T2DM patients treated in our multicenter from January 2022 to December 2022 were enrolled in this study.General information(gender,age,smoking and drinking history,exercise,course of disease,treatment and complications),HbA1c,Athens Insomnia Scale(AIS)scores and Gastrointestinal Symptoms Rating Scale(GSRS)scores of patients were collected.The differences of sleep and gastrointestinal symptoms between groups were analyzed,and the correlation between the differences and HbA1c was analyzed.Furthermore,the risk factors for non-standard HbA1c were analyzed.Results The AIS score and GSRS score in the HbA1c control group were less than those in the non-standard group(P<0.01).Insomnia was reported by 37.0%of T2DM patients,and the HbA1c level in the insomnia group was significantly higher than that in the non-insomnia group(10.00%±2.38%vs.8.26%±1.73%,P<0.01).Gastrointestinal symptoms were present in 57.5%of T2DM patients,and the HbA1c levels in the group with gastrointestinal symptoms were significantly higher than those in the group without gastrointestinal symptoms(9.26%±2.23%vs.8.43%±1.98%,P<0.01).Furthermore,26.3%of T2DM patients experienced both insomnia and gastrointestinal symptoms.Remarkably,the HbA1c levels in the group with both insomnia and gastrointestinal symptoms were significantly higher than those in the group without either condition(10.18%±2.44%vs.8.45%±1.86%,P<0.01).Correlation analysis demonstrated a significant association between sleep quality,gastrointestinal function,and HbA1c levels(P<0.01).The logistic regression analysis result revealed that age,GSRS score,AIS score,and the presence of insomnia combined with gastrointestinal symptoms were independent risk factors for predicting HbA1c≥6.5%(P<0.01).Having both insomnia and gastrointestinal symptoms concurrently was the strongest risk factor for substandard HbA1c control,and the risk of blood sugar control may increase about 5 times when both appear together.Conclusion Insomnia and gastrointestinal symptoms are common comorbidities in T2DM patients,showing a cross-interfering relationship,and they appear together with poor blood sugar control,interact causally,and amplify each other.
		                        		
		                        		
		                        		
		                        	
2.A trial of arbidol hydrochloride in adults with COVID-19
Jingya ZHAO ; Jinnong ZHANG ; Yang JIN ; Zhouping TANG ; Ke HU ; Hui SUN ; Mengmeng SHI ; Qingyuan YANG ; Peiyu GU ; Hongrong GUO ; Qi LI ; Haiying ZHANG ; Chenghong LI ; Ming YANG ; Nian XIONG ; Xuan DONG ; Juanjuan XU ; Fan LIN ; Tao WANG ; Chao YANG ; Bo HUANG ; Jingyi ZHANG ; Shi CHEN ; Qiong HE ; Min ZHOU ; Jieming QU
Chinese Medical Journal 2022;135(13):1531-1538
		                        		
		                        			
		                        			Background::To date, there is no effective medicine to treat coronavirus disease 2019 (COVID-19), and the antiviral efficacy of arbidol in the treatment for COVID-19 remained equivocal and controversial. The purpose of this study was to evaluate the efficacy and safety of arbidol tablets in the treatment of COVID-19.Methods::This was a prospective, open-label, controlled and multicenter investigator-initiated trial involving adult patients with confirmed severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Patients were stratified 1:2 to either standard-of-care (SOC) or SOC plus arbidol tablets (oral administration of 200 mg per time, three times a day for 14 days). The primary endpoint was negative conversion of SARS-CoV-2 within the first week. The rates and 95% confidential intervals were calculated for each variable.Results::A total of 99 patients with laboratory-confirmed SARS-CoV-2 infection were enrolled; 66 were assigned to the SOC plus arbidol tablets group, and 33 to the SOC group. The negative conversion rate of SARS-CoV-2 within the first week in patients receiving arbidol tablets was significantly higher than that of the SOC group (70.3% [45/64] vs. 42.4% [14/33]; difference of conversion rate 27.9%; 95% confidence interval [CI], 7.7%-48.1%; P = 0.008). Compared to those in the SOC group, patients receiving arbidol tablets had a shorter duration of clinical recovery (median 7.0 days vs. 12.0 days; hazard ratio [HR]: 1.877, 95% CI: 1.151-3.060, P = 0.006), symptom of fever (median 3.0 days vs. 12.0 days; HR: 18.990, 95% CI: 5.350-67.410, P < 0.001), as well as hospitalization (median 12.5 days vs. 20.0 days; P < 0.001). Moreover, the addition of arbidol tablets to SOC led to more rapid normalization of declined blood lymphocytes (median 10.0 days vs. 14.5 days; P > 0.05). The most common adverse event in the arbidol tablets group was the elevation of transaminase (5/200, 2.5%), and no one withdrew from the study due to adverse events or disease progression. Conclusions::SOC plus arbidol tablets significantly increase the negative conversion rate of SARS-CoV-2 within the first week and accelerate the recovery of COVID-19 patients. During the treatment with arbidol tablets, we find no significant serious adverse events.Trial registration::Chinese Clinical Trial Registry, NCT04260594, www.clinicaltrials.gov/ct2/show/NCT04260594?term= NCT04260594&draw=2&rank=1
		                        		
		                        		
		                        		
		                        	
3.Efficacy and safety of Shenyankangfu Tablet, a Chinese patent medicine, for primary glomerulonephritis: A multicenter randomized controlled trial.
Jie WU ; Shu-Wei DUAN ; Hong-Tao YANG ; Yue-Yi DENG ; Wei LI ; Ya-Ni HE ; Zhao-Hui NI ; Yong-Li ZHAN ; Shan LIN ; Zhi-Yong GUO ; Jun ZHU ; Jing-Ai FANG ; Xu-Sheng LIU ; Li-Hua WANG ; Rong WANG ; Nian-Song WANG ; Xiao-Hong CHENG ; Li-Qun HE ; Ping LUO ; Shi-Ren SUN ; Ji-Feng SUN ; Ai-Ping YIN ; Geng-Ru JIANG ; Hong-Yu CHEN ; Wen-Hu LIU ; Hong-Li LIN ; Meng LIANG ; Lu MA ; Ming CHEN ; Li-Qun SONG ; Jian CHEN ; Qing ZHU ; Chang-Ying XING ; Yun LI ; Ji-Ning GAO ; Rong-Shan LI ; Ying LI ; Hao ZHANG ; Ying LU ; Qiao-Ling ZHOU ; Jun-Zhou FU ; Qiang HE ; Guang-Yan CAI ; Xiang-Mei CHEN
Journal of Integrative Medicine 2021;19(2):111-119
		                        		
		                        			BACKGROUND:
		                        			Shenyankangfu Tablet (SYKFT) is a Chinese patent medicine that has been used widely to decrease proteinuria and the progression of chronic kidney disease.
		                        		
		                        			OBJECTIVE:
		                        			This trial compared the efficacy and safety of SYKFT, for the control of proteinuria in primary glomerulonephritis patients, against the standard drug, losartan potassium.
		                        		
		                        			DESIGN, SETTING, PARTICIPANTS AND INTERVENTION:
		                        			This was a multicenter, double-blind, randomized, controlled clinical trial. Primary glomerulonephritis patients, aged 18-70 years, with blood pressure ≤ 140/90 mmHg, estimated glomerular filtration rate (eGFR) ≥ 45 mL/min per 1.73 m
		                        		
		                        			MAIN OUTCOME MEASURES:
		                        			The primary outcome was change in the 24-hour proteinuria level, after 48 weeks of treatment.
		                        		
		                        			RESULTS:
		                        			A total of 735 participants were enrolled. The percent decline of urine protein quantification in the SYKFT group after 48 weeks was 8.78% ± 2.56% (P = 0.006) more than that in the losartan 50 mg group, which was 0.51% ± 2.54% (P = 1.000) less than that in the losartan 100 mg group. Compared with the losartan potassium 50 mg group, the SYKFT plus losartan potassium 50 mg group had a 13.39% ± 2.49% (P < 0.001) greater reduction in urine protein level. Compared with the losartan potassium 100 mg group, the SYKFT plus losartan potassium 100 mg group had a 9.77% ± 2.52% (P = 0.001) greater reduction in urine protein. With a superiority threshold of 15%, neither was statistically significant. eGFR, serum creatinine and serum albumin from the baseline did not change statistically significant. The average change in TCM syndrome score between the patients who took SYKFT (-3.00 [-6.00, -2.00]) and who did not take SYKFT (-2.00 [-5.00, 0]) was statistically significant (P = 0.003). No obvious adverse reactions were observed in any group.
		                        		
		                        			CONCLUSION:
		                        			SYKFT decreased the proteinuria and improved the TCM syndrome scores of primary glomerulonephritis patients, with no change in the rate of decrease in the eGFR. SYKFT plus losartan potassium therapy decreased proteinuria more than losartan potassium therapy alone.
		                        		
		                        			TRIAL REGISTRATION NUMBER
		                        			NCT02063100 on ClinicalTrials.gov.
		                        		
		                        		
		                        		
		                        	
4.Forensic Analysis of Sudden Death Associated with Sexual Activity.
Shu-Quan ZHAO ; Fang HUANG ; Wei-Nian DENG ; Long-da MA ; Zi-Hao LIU ; Qing SHI ; Yi-Wu ZHOU
Journal of Forensic Medicine 2021;37(6):832-835
		                        		
		                        			OBJECTIVES:
		                        			To analyze the characteristics of sudden death associated with sexual activity to provide recommendations for forensic identification.
		                        		
		                        			METHODS:
		                        			A retrospective analysis was conducted on autopsy cases accepted by Forensic Identification Center of Huazhong University of Science and Technology from 1998 to 2018, and a total of 15 cases of sudden death associated with sexual activity were screened out. The general information, case data and pathological changes of 15 cases were collected to find the relationship between sexual activity and sudden death.
		                        		
		                        			RESULTS:
		                        			The ratio of male to female was 1.5∶1. The average age of males was 50.1 years and that of females was 35.0 years. Coronary artery diseases and brain diseases accounted for most of the cases (12/15). Sexual partners were associated with locations of deaths and body dumping behaviors.
		                        		
		                        			CONCLUSIONS
		                        			Sudden death associated with sexual activity, although rare, may occur in people over 30 years old with pre-existing heart or brain diseases, which should be paid attention to in forensic practice.
		                        		
		                        		
		                        		
		                        			Adult
		                        			;
		                        		
		                        			Cause of Death
		                        			;
		                        		
		                        			Death, Sudden/pathology*
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Forensic Medicine
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Sexual Behavior
		                        			
		                        		
		                        	
5.Not Available.
Zi hao LIU ; Shu quan ZHAO ; Jian yi CHEN ; Wei nian DENG ; Qing SHI ; Yi wu ZHOU
Journal of Forensic Medicine 2021;37(5):718-720
6.A rapid identification of authenticity and specifications of Chinese medicine Fritillariae Cirrhosae Bulbus based on E-eye technology.
Rui-Xin LIU ; Xiao-Jia HAO ; Hui-Jie ZHANG ; Lu ZHANG ; Xin-Jing GUI ; Zhao-Zhou LIN ; Chong-Nian LUO ; Liang-Yu TIAN ; Yan-Li WANG ; Wen-Hao FENG ; Jing YAO ; Xue-Lin LI
China Journal of Chinese Materia Medica 2020;45(14):3441-3451
		                        		
		                        			
		                        			The quality of traditional Chinese medicine tablets is correlated with clinical efficacy and drug safety, and plays a great role in promoting the development of traditional Chinese medicine. However, the existing traditional artificial identification and modern instrument detection in terms of accuracy and timeliness have both advantages and disadvantages. Therefore, how to quickly and accurately identify the quality of traditional Chinese medicine tablets has become a high-profile issue. The purpose of this paper is to explore the feasibility of the application of electronic eye technology in the study of rapid identification of traditional Chinese medicine quality. A total of 80 batches of samples were collected and tested by Fritillariae Cirrhosae Bulbus for traditional empirical identification(M_1) and modern pharmacopeia(M_2). The optical data was collected from electronic eyes, and the chemical metrology was used to establish suitable discrimination models(M_3). Four authenticity and commodity specification models, namely identification analysis(DA), minimum bidirectional support vector machine(LS-SVM), partial minimum two-multiplier analysis(PLS-DA), main component analysis identification analysis(PCA-DA), were established, respectively. The accuracies of the authenticity identification models were 82.5%, 90.0%, 96.2% and 93.8%, while the accuracies of the commodity specification identification models were 89.3%, 96.0%, 90.7% and 97.3%, respectively. The models were well judged, the authenticity identification was based on the final identification model of PLS-DA, and the commodity specification was based on the final identification model of PCA-DA. There was no significant difference between its accuracy and M_1, and the time of determination was much shorter than M_2(P<0.01). Therefore, electronic-eye technology could be used for the rapid identification of the quality of Fritillariae Cirrhosae Bulbus.
		                        		
		                        		
		                        		
		                        			Drugs, Chinese Herbal
		                        			;
		                        		
		                        			Fritillaria
		                        			;
		                        		
		                        			Medicine, Chinese Traditional
		                        			;
		                        		
		                        			Plant Roots
		                        			;
		                        		
		                        			Technology
		                        			
		                        		
		                        	
7.Effects of Niaoduqing Particles () on Delaying Progression of Renal Dysfunction: A Post-trial, Open-Label, Follow-up Study.
Ying ZHENG ; Nian-Song WANG ; Yu-Ning LIU ; Li-Qun HE ; Gui-Hua JIAN ; Xu-Sheng LIU ; Zhao-Hui NI ; Xiao-Hong CHENG ; Hong-Li LIN ; Wen-Hua ZHOU ; Ya-Ping WANG ; Jing-Ai FANG ; Ya-Ni HE ; Hong-Tao YANG ; Li-Juan ZHAO ; Han-Lu DING ; Li-Hua WANG ; Ren-Huan YU ; Wen-Ge LI ; Zhi-Ming YE ; Wang GUO ; Yong-Li ZHAN ; Hui-Juan MAO ; Zhao HU ; Chen YAO ; Guang-Yan CAI ; Xiang-Mei CHEN
Chinese journal of integrative medicine 2019;25(3):168-174
		                        		
		                        			OBJECTIVE:
		                        			To follow up the participants of the randomized clinical trial "Efficacy and Safety of Niaoduqing Particles () for Delaying Moderate-to-Severe Renal Dysfunction", and assess the long-term effects of Niaoduqing Particles on delaying the progression of renal dysfunction.
		                        		
		                        			METHODS:
		                        			Participants, who had previously been randomly assigned to receive Niaoduqing Particles or placebo for 24 weeks (146 cases in each group), were invited to follow-up and all were administered Niaoduqing Particles 5 g thrice daily and 10 g before bedtime for 24 weeks. The primary endpoints were changes in baseline serum creatinine (Scr) and estimated glomerular filtration rate (eGFR) after completion of the open-label treatment period.
		                        		
		                        			RESULTS:
		                        			After the double-blind period, the median (interquartile range) changes in Scr were 1.1 (-13.0-24.1) and 11.7 (-2.6-42.9) μmol/L for the Niaoduqing Particle and placebo groups, respectively (P=0.008), and the median changes in eGFRs were-0.2 (-4.3-2.7) and-2.21 (-5.7-0.8) mL•min•1.73 m, respectively (P=0.016). There were significant differences in the double-blind period changes in renal function between groups. After the open-label period, the median changes in Scr were 9.0 (-10.0-41.9) and 17.5 (-6.0-50.0) μmol/L for the Niaoduqing Particle and placebo groups according to baseline grouping, respectively (P=0.214), and the median changes in eGFRs were-2.3 (-6.4-1.9) and-3.7 (-7.5-1.1) mL•min•1.73 m, respectively (P=0.134). There were no statistical differences in the open-label period changes in renal function between groups. The eGFR reduction of participants who accepted Niaoduqing Particle treatment for 48 weeks was projected to 2.5 mL•min•1.73 m per year.
		                        		
		                        			CONCLUSION
		                        			Niaoduqing Particles appear to have long-term efficacy for patients with moderate-to-severe renal dysfunction. Although there was no statistical difference, the early use of Niaoduqing Paticles seems to ameliorate the worsening of renal function. (Trial registration No. ChiCTR-TRC-12002448).
		                        		
		                        		
		                        		
		                        			Adult
		                        			;
		                        		
		                        			Disease Progression
		                        			;
		                        		
		                        			Double-Blind Method
		                        			;
		                        		
		                        			Drugs, Chinese Herbal
		                        			;
		                        		
		                        			therapeutic use
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Follow-Up Studies
		                        			;
		                        		
		                        			Glomerular Filtration Rate
		                        			;
		                        		
		                        			drug effects
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Kidney Diseases
		                        			;
		                        		
		                        			drug therapy
		                        			;
		                        		
		                        			physiopathology
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Outcome Assessment (Health Care)
		                        			
		                        		
		                        	
8.Identification of gene mutation associated with familial dilated cardiomyopathy by whole-exome sequencing
Nian-Wei ZHOU ; Sheng-Mei QIN ; Yang LIU ; Wei-Peng ZHAO ; Jie CUI ; Cui-Zhen PAN ; Rui-Zhen CHEN ; Xiao-Lin WANG ; Xian-Hong SHU
Fudan University Journal of Medical Sciences 2018;45(2):164-168
		                        		
		                        			
		                        			Objective To identify the disease-causing gene in a Chinese pedigree with familial dilated cardiomyopathy (DCM) by whole-exome sequencing.Methods After collecting the clinical data and extracting the whole blood genomic DNA of the 5 family members form a Chinese DCM pedigree,whole-exome sequencing was performed to search the causative genes.Familial co-segregation analysis among the pedigree was subsequently confirmed by traditional Sanger sequencing.Results We performed whole exome sequencing (WES) on representative affected individuals and unaffected familial members from this pedigree.After comparison with variants identified in affected individuals and unaffected individuals,along with previously reported genetic mutations associated with DCM,we found that a heterozygous variant c.961 C>T (p.Arg321Ter) in exon 6 of the LMNA gene in affected individuals matched the criteria to be the potential disease-causing gene,which was confirmed by Sanger sequencing.This stop-gain mutation leads to only a small part of LMNA-coding protein expressed,therefore we concluded that LMNA c.961 C>T should be the causative mutation for this familial DCM case.Conclusions The nonsense mutation c.961 C> T in gene LMNA identified by whole-exome sequencing might be the pathogenic mutation in this DCM pedigree.
		                        		
		                        		
		                        		
		                        	
9.Safety, Effectiveness, and Manipulability of Peritoneal Dialysis Machines Made in China: A Randomized, Crossover, Multicenter Clinical Study.
Xue-Ying CAO ; Ya-Ni HE ; Jian-Hui ZHOU ; Shi-Ren SUN ; Li-Ning MIAO ; Wen CHEN ; Jing-Ai FANG ; Ming WANG ; Nian-Song WANG ; Hong-Li LIN ; Jian LIU ; Zhao-Hui NI ; Wen-Hu LIU ; Yu NA ; Jiu-Yang ZHAO ; Zhi-Yong GUO ; Hong-Guang ZHENG ; Wei SHI ; Geng-Ru JIANG ; Guang-Yan CAI ; Xiang-Mei CHEN
Chinese Medical Journal 2018;131(23):2785-2791
		                        		
		                        			Background:
		                        			Automated peritoneal dialysis (APD) can cater to individual needs, provide treatment while asleep, take into account the adequacy of dialysis, and improve the quality of life. Currently, independent research and development of APD machines made in China are more conducive to patients. A randomized, multicenter, crossover study was conducted by comparing an APD machine made in China with an imported machine. The safety, effectiveness, and manipulability of the two machines were compared.
		                        		
		                        			Methods:
		                        			Two hundred and sixty patients who underwent peritoneal dialysis (PD) on a regular basis in 18 centers between August 2015 and February 2016 were included. The inclusion criteria include age ≥18 years and PD ≥30 days. The exclusion criteria were as follows: hemodialysis; exit site or tunnel infection; and peritonitis ≤30 days. The patients were randomly divided into Group A, who were first treated with a FM machine made in China, then changed to an imported machine; and Group B, who were treated using the reverse sequence. APD treatment was performed with 10 L/10 h and 5 cycles of exchange. After 72 h, the daily peritoneal Kt/V, the accuracy of the injection rate, accuracy of the injection temperature, safety, and manipulability of the machine were assessed. Noninferiority test was conducted between the two groups.
		                        		
		                        			Results:
		                        			The daily peritoneal Kt/V in the APD machine made in China and the imported APD machine were 0.17 (0.14, 0.25) and 0.16 (0.13, 0.23), respectively. There was no significant difference between the groups (Z = 0.15, P = 0.703). The lower limit of the daily Kt/V difference between the two groups was 0.0069, which was greater than the noninferiority value of -0.07 in this study. The accuracy of the injection rate and injection temperature was 89.7% and 91.5%, respectively, in the domestic APD machine, which were both slightly better than the accuracy rates of 84.0% and 86.8% in the imported APD machine (89.7% vs. 84.0%, P = 0.2466; 91.5% vs. 86.8%, P = 0.0954). Therefore, the APD machine made in China was not inferior to the imported APD machine. The fuselage of the imported APD machine was space-saving, while the APD machine made in China was superior with respect to body mobility, man-machine dialog operation, alarm control, and patient information recognition.
		                        		
		                        			Conclusions:
		                        			The FM machine made in China was not inferior to the imported APD machine. In addition, the FM machine made in China had better operability.
		                        		
		                        			Trial Registration
		                        			Clinicaltrials.gov, NCT02525497; https://clinicaltrials.gov/ct2/results?cond=&term=NCT02525497&cntry=& state=&city=&dist=.
		                        		
		                        		
		                        		
		                        			Adult
		                        			;
		                        		
		                        			China
		                        			;
		                        		
		                        			Cross-Over Studies
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Multicenter Studies as Topic
		                        			;
		                        		
		                        			Peritoneal Dialysis
		                        			;
		                        		
		                        			adverse effects
		                        			;
		                        		
		                        			instrumentation
		                        			;
		                        		
		                        			methods
		                        			;
		                        		
		                        			Quality of Life
		                        			;
		                        		
		                        			Temperature
		                        			
		                        		
		                        	
10.The therapeutic effect between metal augment and impacted bone grafting in the hip revision of acetabular bone defect
Zhan-Jie CHEN ; Lei ZHANG ; Chang-Nian DING ; Li-Wu ZHOU ; Ting GUO ; Ni-Rong BAO ; Bei-Yue WANG ; Jian-Ning ZHAO
Journal of Medical Postgraduates 2018;31(4):373-376
		                        		
		                        			
		                        			Objective The application of metal augments in the revision of total hip arthroplasty(THA)has achieved re-markable results in the treatment of bone defects.However,there are limited studies compared this effective method with the traditional treatment.The purpose of this article is to investigate the curative effect of both metal augmentation and impacted bone grafting in the revision of acetabular bone defect. Methods We retrospectively analyzed 20 patients(20 hips)with bone defects after THA in Au-thority of Nanjing General Hospital of Nanjing Military Region from August 2010 to February 2017.These 20 patients were allocated into 2 groups:impacted bone grafting group(n=11,filling acetabular bone defect with autogenous iliac bone and artificial bone)and metal aug-mentation group(n=9,filling acetabular bone defect with metal aug-ment).The duration of surgery,blood loss and the hospital for special surgery knee score(HSS)were compared between these two groups and the Harris score was applied to evaluate the hip function and full weight bearing. Results The surgery duration and blood loss of impacted bone grafting group were significantly increased when compared with the metal augmentation group(44.5±7.82 min vs 36.22±5.19 min and 431.82±57.76 mL vs 333.33±72.80 mL respec-tively).there were 3 cases showed mild bone resorption in the I regions in the impacted bone grafting group, while only one case showed mild bone resorption in the II region in the metal augmentation group.The HSS scores in the metal augmentation group were higher than those in the impacted bone grafting group at the time of postoperative 2 weeks(43.89±2.76 vs 40.82±4.42), 3 months (49.89±2.03 vs 45.27±3.90)and 6 months(53.44±2.46 vs 50.55±3.67), the differences were statistically significant(P<0.001). The Harris scores in the metal augmentation group were higher than those in the impacted bone grafting group(P<0.01).The metal augmentation group had a shorter time of getting out of bed compared with the impacted bone grafting group(P<0.01). Conclusion For those patients with upper acetabular bone defect,revision surgery using metal augments can save the operation time.Meanwhile, it is also superior to the impacted bone grafting in the early prosthesis stability and bone ingrowth,and thus enables to shorten the time on getting out of bed and promote functional.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail