1.Cyclocarya paliurus Polysaccharide Inhibits Benign Prostatic Hyperplasia by Reducing 5α-Reductase 2
Qinhui DAI ; Mengxia YAN ; Chen WANG ; Chenjun SHEN ; Chenying JIANG ; Bo YANG ; Huajun ZHAO ; Zhihui ZHU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):107-114
ObjectiveTo investigate the effect and mechanism of polysaccharide in water extract of Cyclocarya paliurus (CPWP) in inhibiting benign prostatic hyperplasia (BPH). MethodsCPWP was obtained by heating reflux, aqueous extraction, alcohol precipitation, and freeze drying. The chemical composition and structural properties of CPWP were analyzed by high performance liquid chromatography with 1-pheny-3-methyl-5-pyrazolone pre-column derivatization and infrared spectroscopy. Male SD rats were randomly assigned into control, model, finasteride (ig 5 mg·kg-1), and low-, medium-, and high-dose (ig 50, 75, 100 mg·kg-1) CPWP groups, with 8 rats in each group. The BPH model was established by subcutaneously injecting propionate testosterone in castrated rats. The rats in the drug intervention groups were administrated with corresponding drugs, and those in the control group were administrated with an equal volume of normal saline each day. After 30 consecutive days, the rats were sacrificed, and the prostate tissue was separated and weighed. The effects of drug interventions on the body weight, prostate wet weight, and prostate index of rats were examined. The prostate tissue was stained with hematoxylin-eosin (HE) for observation of pathological changes. Enzyme-linked immunosorbent assay was employed to measure the level of dihydrotestosterone (DHT), and immunohistochemical staining was used to detect the expression of steroid 5 alpha-reductase 2 (SRD5A2) and Ki67 in the prostate tissue. ResultsCPWP was identified as a saccharide, with characteristic absorption peaks of saccharides. CPWP showed the total sugar content of 44.15% and molecular weight within the range of 5.5-78.8 kDa, being composed of mannose, rhamnose, galacturonic acid, glucose, galactose, xylose, and arabinose. Compared with the control group, the model group had significantly increased prostate wet weight and prostate index (P<0.01), thick and tall prostate epithelial cells, increased internal wrinkles, papillary expansion into the cavity, an elevation in DHT level in the serum, and up-regulated expression of SRD5A2 and Ki67 in the prostate tissue (P<0.05, P<0.01). Compared with the model group, both the finasteride and CPWP groups showed decreases in prostate wet weight and prostate index (P<0.05, P<0.01), thinned prostate epithelial cells, with only a small portion of internal wrinkles and papillary expansion into the cavity, shortened papillary protrusions, lowered DHT level in the serum, and down-regulated expression of SRD5A2 and Ki67 in the prostate tissue (P<0.01). Moreover, CPWP exerted effects in a dose-dependent manner. ConclusionCPWP inhibits BPH by regulating the expression of SRD5A2.
2.Updates and amendments of the Chinese Pharmacopoeia 2025 Edition (Volume Ⅰ)
LI Hao ; SHEN Mingrui ; ZHANG Pang ; ZHAI Weimin ; NI Long ; HAO Bo ; ZHAO Yuxin ; HE Yi ; MA Shuangcheng ; SHU Rong
Drug Standards of China 2025;26(1):017-022
The Chinese Pharmacopoeia is the legal technical standard which should be followed during the research, production, use, and administration of drugs. At present, the new edition of the Chinese Pharmacopoeia is planned to be promulgated and implemented. This article summarizes and analyzes the main characteristics and the content of updates and amendments of the Chinese Pharmacopoeia 2025 Edition(Volume Ⅰ), to provide a reference for the correct understanding and accurate implementation the new edition of the pharmacopoeia.
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Developing Syllabus for Rare Breast Diseases Using the Integrated Multimodality of Case-/Problem-/Resource-Based Learning
Ru YAO ; Jiahui ZHANG ; Jie LIAN ; Yang QU ; Xinyue ZHANG ; Xin HUANG ; Lu GAO ; Jun ZHAO ; Li HUANG ; Yingzi JIANG ; Linzhi LUO ; Songjie SHEN ; Feng MAO ; Qiang SUN ; Bo PAN ; Yidong ZHOU
JOURNAL OF RARE DISEASES 2024;3(3):391-399
Objective This study aims at establishing a teaching catalog and content for breast rare dis-eases and developing the syllabus for the breast rare disease using integrated multimodality of case-/problem-/resource-based learning(CBL+PBL+RBL).Methods By conducting bibliometrics co-occurrence analysis,we collected 6291 articles on breast rare disease published from January,1975 to June,2024.Additionally,we re-trieved the Textbook on Rare Diseases,the Catalog of Chinese Rare Disease,and Second Batch of Rare Dis-ease Catalog and then decided the teaching content.Results From 16,387 keywords,1000(6.1%)keywords were identified through co-occurrence analysis,including 50(0.3%)candidate diseases.These were classified into three categories:rare primary breast diseases,rare genetic mutation-related diseases associated with breast cancer,and rare systemic multi-system diseases involving the breast.From the candidate list,20(0.1%)rare primary breast diseases were further selected for their notable clinical teaching significance,and significant multi-systemic diseases affecting the breast,whether related to gene mutations or not.Teaching plans were draf-ted using a diversified parallel teaching approaches,taking into account the characteristics of different diseases and the focus of different teaching methods.Conclusions This study initiated the development of the teaching content for breast rare diseases and developed the teaching syllabus using the CBL+PBL+RBL integrated multi teaching model and targeting each rare breast disease for the critical point for teaching.
7.Comparison of clinically relevant factors in bipolar disorder patients with different age of onset
Yan MA ; Xiaoyi TIAN ; Yueqin HUANG ; Zhaorui LIU ; Yongyan DENG ; Liang ZHOU ; Yan LIU ; Bo LIU ; Jie ZHANG ; Yuandong GONG ; Xiang FU ; Qiongxian ZHAO ; Jin LU ; Wannian SHA ; Hao HE ; Zonglin SHEN ; Tingting ZHANG ; Wenming CHEN
Chinese Mental Health Journal 2024;38(1):42-49
Objective:To compare clinical characteristics,treatment patterns and physiological indicators in bipolar disorder(BD)patients with different age of onset.Methods:Totally 380 patients with DSM-5 BD were se-lected in this study.Psychiatrists diagnosed the patients using the Mini International Neuropsychiatric Interview.The clinical information questionnaire and the Global Assessment of Functioning scale were utilized to collected clinical characteristics,treatment status,and physiological indicators.The onset age of BD was divided into 21 and 35 years as cut-off points.Multivariate logistic regression and linear regression were used to analyze related factors.Results:Among the 380 patients with BD,199 cases were early-onset group(52.4%),121 cases were middle-onset group(31.8%),and 60 cases were late-onset group(15.8%).There were 26.6%of patients in the early-onset group in-itially diagnosed as depression,23.1%in the middle-onset group,and 11.7%in the late-onset group.Multivariate analysis revealed that compared to the early-onset group of BD,the middle-onset(OR=2.22)and late-onset(OR=4.99)groups had more risk to experience depressive episodes,and the late-onset group(OR=6.74)had 6.74 times of risk to suffer from bipolar Ⅱ disorder.Additionally,patients in the middle-onset(β=-1.52)and late-on-set(β=-4.29)groups had shorter durations of delayed treatment,and those in the middle-onset(β=-1.62)and late-onset(β=-3.14)groups had fewer hospitalizations.Uric acid levels were lower in both the middle-onset(β=-28.39)and late-onset(β=-31.47)groups,and total cholesterol level was lower in the middle-onset group(β=-0.23).Conclusion:Patients with BD in different age of onset show significant differences in clinical charac-teristics,treatment conditions and physiological indicators.
8.IgA nephropathy with mesangial type Ⅲ collagen deposition:2 cases report
Jie-Bo HUANG ; Xiao-Fan CAI ; Zhong-Hua ZHAO ; Zhi-Gang ZHANG ; Qiang SHEN ; Hao WANG ; Hui-Juan WU
Fudan University Journal of Medical Sciences 2024;51(3):426-430
As interstitial collagen,type Ⅲ collagen(Col Ⅲ)does not express in normal glomeruli.However,in Col Ⅲ nephropathy,a large amount of Col Ⅲ deposit in the mesangial and subendothelial area of the glomeruli.IgA nephropathy with Col Ⅲ deposition was extremely rare.In this article,we reported two cases of such disease.After treating with immunosuppressive agents or traditional Chinese medicine decoction,the renal function of the two patients remained stable and the urinary protein levels reduced significantly.
9.Application of transesophageal echocardiography in the assessment of left atrial ear volume and function changes in patients with patent foramen ovale and atrial fibrillation
Junwei WANG ; Lijun DU ; Xu WANG ; Ling ZENG ; Zhao SHEN ; Bo HOU
Journal of Clinical Medicine in Practice 2024;28(9):20-24
Objective To investigate the application of transesophageal echocardiography in the evaluation of left atrial ear volume and function changes in patients with patent foramen ovale and atrial fibrillation. Methods Eighty patients with patent foramen ovale were selected as the study objects, and were divided into atrial fibrillation group (


Result Analysis
Print
Save
E-mail