1.Application of blood conservation measures with different red blood cell transfusion volumes in obstetrics and their impact on postpartum outcomes
Huimin DENG ; Fengcheng XU ; Meiting LI ; Lan HU ; Xiao WANG ; Shiyu WANG ; Xiaofei YUAN ; Jun ZHENG ; Zehua DONG ; Yuanshan LU ; Shaoheng CHEN
Chinese Journal of Blood Transfusion 2025;38(5):691-698
Objective: To evaluate the application of blood conservation measures in obstetric patients with different red blood cell transfusion volumes and to assess the impact of different transfusion volumes on postpartum outcomes. Methods: A retrospective investigation was conducted on 448 obstetric patients who received blood transfusions at the Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine from January 2016 to December 2022. Patients were divided into four groups (1-2 units group, 3-4 units group, 5-6 units group, and >6 units group) based on the volumes of red blood cells (RBCs) transfused during and within 7 days after delivery. The maternal physiological indicators, pre- and postpartum laboratory test indicators, obstetric complications, application of blood conservation measures, use of blood products, and postpartum outcomes were reviewed. The clinical characteristics, application of blood conservation measures, and their impact on postpartum outcomes were compared among different transfusion groups. Results: There were statistically significant differences in the multivariate logistic analysis of history of previous cesarean section (OR=1.781), eclampsia/pre-eclampsia/(OR=1.972) and postpartum blood loss>1 000 mL(OR=1.699)(P<0.05) among different transfusion groups. In terms of blood conservation measures, the more RBCs transfused, the higher the rate of mothers receiving blood conservation measures such as balloon occlusion, arterial ligation, autologous blood transfusion with a cell saver, and hysterectomy. With the increase in the volume of RBCs transfusion, the demand for fresh frozen plasma(FFP), cryoprecipitate, and platelet transfusions also increased. The hospitalization days for the four groups of parturients were 6.0 (4.0-9.0), 7.5 (5.0-14.8), 7.0 (4.5-13.0) and 11.0 (9.0-20.5), respectively (P<0.05) and the rates of ICU transfer were 2.0% (5/250), 9.4% (12/128),18.2% (6/33) and 51.4% (19/37), respectively (P<0.05). Both increased significantly with the increase in the volume of RBCs transfusion, and the differences between groups were statistically significant. Conclusion: Parturients who received higher volume of RBCs had multiple risks factors for bleeding before childbirth, had higher postpartum blood loss, and had a higher rate of application of various blood conservation measures. In addition, an increase in the volume of RBCs transfusion may have adverse effects on postpartum recovery.
2.Construction and verification of intelligent endoscopic image analysis system for monitoring upper gastrointestinal blind spots
Xiaoquan ZENG ; Zehua DONG ; Lianlian WU ; Yanxia LI ; Yunchao DENG ; Honggang YU
Chinese Journal of Digestive Endoscopy 2024;41(5):391-396
Objective:To construct an intelligent endoscopic image analysis system that could monitor the blind spot of the upper gastrointestinal tract, and to test its performance.Methods:A total of 87 167 upper gastrointestinal endoscopy images (dataset 1) including 75 551 for training and 11 616 for testing, and a total of 2 414 pharyngeal images (dataset 2) including 2 233 for training and 181 for testing were retrospectively collected from the Digestive Endoscopy Center of Renmin Hospital of Wuhan University between 2016 to 2020. A 27-category-classification model for blind spot monitoring in the upper gastrointestinal tract (model 1, which distinguished 27 anatomical sites such as the pharynx, esophagus, and stomach) and a 5-category-classification model for blind spot monitoring in the pharynx (model 2, which distinguished palate, posterior pharyngeal wall, larynx, left and right pyriform sinuses) were constructed. The above models were trained and tested based on dataset 1 and 2, respectively, and trained based on the EfficientNet-B4, ResNet50 and VGG16 models of the keras framework. Thirty complete upper gastrointestinal endoscopy videos were retrospectively collected from the Digestive Endoscopy Center of Renmin Hospital of Wuhan University in 2021 to test model 2 blind spot monitoring performance.Results:The cross-sectional comparison results of the accuracy of model 1 in identifying 27 anatomical sites of the upper gastrointestinal tract in images showed that the mean accuracy of EfficientNet-B4, ResNet50, and VGG16 were 90.90%, 90.24%, and 89.22%, respectively, with the EfficientNet-B4 model performance the best, and the accuracy of EfficientNet-B4 model for each site ranged from 80.49% to 97.80%. The cross-sectional comparison results of the accuracy of model 2 in identifying the 5 anatomical sites of the pharynx in the images showed that the mean accuracy of EfficientNet-B4, ResNet50, and VGG16 were 99.40%, 98.56%, and 97.01%, respectively, in which the EfficientNet-B4 model had the best performance, and the accuracy of EfficientNet-B4 model for each site ranged from 96.15% to 100.00%. The overall accuracy of model 2 in identifying the 5 anatomical sites of the pharynx in the video was 97.33% (146/150).Conclusion:The intelligent endoscopic image analysis system based on deep learning can monitor blind spots in the upper gastrointestinal tract, coupled with pharyngeal blind spot monitoring and esophagogastroduodenal blind spot monitoring functions. The system shows high accuracy in both images and videos, which is expected to have a potential role in clinical practice and assisting endoscopists to achieve full observation of the upper gastrointestinal tract.
3.An artificial intelligence system based on multi-modal endoscopic images for the diagnosis of gastric neoplasms (with video)
Xiao TAO ; Lianlian WU ; Hongliu DU ; Zehua DONG ; Honggang YU
Chinese Journal of Digestive Endoscopy 2024;41(9):690-696
Objective:To develop an artificial intelligence model based on multi-modal endoscopic images for identifying gastric neoplasms and to compare its diagnostic efficacy with traditional models and endoscopists.Methods:A total of 3 267 images of gastric neoplasms and non-neoplastic lesions under white light (WL) endoscopy and weak magnification (WM) endoscopy from 463 patients at the Digestive Endoscopy Center of Renmin Hospital of Wuhan University from March 2018 to December 2019 were utilized. Two single-modal models (WL model and WM model) were constructed based on WL and WM images separately. WL and WM images of corresponding lesions were combined into image pairs for creating a multi-modal (MM) characteristics integration model. A test set consisting of 696 images of 102 lesions from 97 patients from March 2020 to March 2021 was used to compare the diagnostic efficacy of the single-modal models and a multi-modal model for gastric neoplastic lesions at both the image and the lesion levels. Additionally, video clips of 80 lesions from 80 patients from January 2022 to June 2022 were employed to compare diagnostic efficacy of the WM model, the MM model and 7 endoscopists at the lesion level for gastric neoplasms.Results:In the image test set, the sensitivity and accuracy of MM model were 84.96% (576/678), and 86.89% (1 220/1 289), respectively, for diagnosing gastric neoplasms at the image level, which were superior to 63.13% (113/179) and 80.59% (353/438) of WM model ( χ2=42.81, P<0.001; χ2=10.33, P=0.001), and also better than those of WL model [70.47% (74/105), χ2=13.52, P<0.001; 67.82% (175/258), χ2=57.27, P<0.001]. The MM model showed a sensitivity of 87.50% (28/32), a specificity of 88.57% (62/70), and an accuracy of 88.24% (90/102) at the lesion level. The specificity ( χ2=22.99, P<0.001) and accuracy ( χ2=19.06, P<0.001) were significantly higher than those of WL model; however, there was no significant difference compared with those of the WM model ( P>0.05). In the video test, the sensitivity, specificity and accuracy of the MM model at the lesion level were 95.00% (19/20), 93.33% (56/60) and 93.75% (75/80). These results were significantly better than those of endoscopists, who had a sensitivity of 77.14% (108/140), a specificity of 79.29% (333/420), and an accuracy of 78.75% (441/560), with significant differences ( χ2=18.62, P<0.001; χ2=35.07, P<0.001; χ2=53.12, P<0.001), and was higher than the sensitivity of advanced endoscopists [83.33% (50/60)] with significant difference ( χ2=4.23, P=0.040). Conclusion:The artificial intelligence model based on multi-modal endoscopic images for the diagnosis of gastric neoplasms shows high efficacy in both image and video test sets, outperforming the average diagnostic performance of endoscopists in the video test.
4.Artificial intelligence-assisted diagnosis system of Helicobacter pylori infection based on deep learning
Mengjiao ZHANG ; Lianlian WU ; Daqi XING ; Zehua DONG ; Yijie ZHU ; Shan HU ; Honggang YU
Chinese Journal of Digestive Endoscopy 2023;40(2):109-114
Objective:To construct an artificial intelligence-assisted diagnosis system to recognize the characteristics of Helicobacter pylori ( HP) infection under endoscopy, and evaluate its performance in real clinical cases. Methods:A total of 1 033 cases who underwent 13C-urea breath test and gastroscopy in the Digestive Endoscopy Center of Renmin Hospital of Wuhan University from January 2020 to March 2021 were collected retrospectively. Patients with positive results of 13C-urea breath test (which were defined as HP infertion) were assigned to the case group ( n=485), and those with negative results to the control group ( n=548). Gastroscopic images of various mucosal features indicating HP positive and negative, as well as the gastroscopic images of HP positive and negative cases were randomly assigned to the training set, validation set and test set with at 8∶1∶1. An artificial intelligence-assisted diagnosis system for identifying HP infection was developed based on convolutional neural network (CNN) and long short-term memory network (LSTM). In the system, CNN can identify and extract mucosal features of endoscopic images of each patient, generate feature vectors, and then LSTM receives feature vectors to comprehensively judge HP infection status. The diagnostic performance of the system was evaluated by sensitivity, specificity, accuracy and area under receiver operating characteristic curve (AUC). Results:The diagnostic accuracy of this system for nodularity, atrophy, intestinal metaplasia, xanthoma, diffuse redness + spotty redness, mucosal swelling + enlarged fold + sticky mucus and HP negative features was 87.5% (14/16), 74.1% (83/112), 90.0% (45/50), 88.0% (22/25), 63.3% (38/60), 80.1% (238/297) and 85.7% (36 /42), respectively. The sensitivity, specificity, accuracy and AUC of the system for predicting HP infection was 89.6% (43/48), 61.8% (34/55), 74.8% (77/103), and 0.757, respectively. The diagnostic accuracy of the system was equivalent to that of endoscopist in diagnosing HP infection under white light (74.8% VS 72.1%, χ2=0.246, P=0.620). Conclusion:The system developed in this study shows noteworthy ability in evaluating HP status, and can be used to assist endoscopists to diagnose HP infection.
5.Evaluation of an assistant diagnosis system for gastric neoplastic lesions under white light endoscopy based on artificial intelligence
Junxiao WANG ; Zehua DONG ; Ming XU ; Lianlian WU ; Mengjiao ZHANG ; Yijie ZHU ; Xiao TAO ; Hongliu DU ; Chenxia ZHANG ; Xinqi HE ; Honggang YU
Chinese Journal of Digestive Endoscopy 2023;40(4):293-297
Objective:To assess the diagnostic efficacy of upper gastrointestinal endoscopic image assisted diagnosis system (ENDOANGEL-LD) based on artificial intelligence (AI) for detecting gastric lesions and neoplastic lesions under white light endoscopy.Methods:The diagnostic efficacy of ENDOANGEL-LD was tested using image testing dataset and video testing dataset, respectively. The image testing dataset included 300 images of gastric neoplastic lesions, 505 images of non-neoplastic lesions and 990 images of normal stomach of 191 patients in Renmin Hospital of Wuhan University from June 2019 to September 2019. Video testing dataset was from 83 videos (38 gastric neoplastic lesions and 45 non-neoplastic lesions) of 78 patients in Renmin Hospital of Wuhan University from November 2020 to April 2021. The accuracy, the sensitivity and the specificity of ENDOANGEL-LD for image testing dataset were calculated. The accuracy, the sensitivity and the specificity of ENDOANGEL-LD in video testing dataset for gastric neoplastic lesions were compared with those of four senior endoscopists.Results:In the image testing dataset, the accuracy, the sensitivity, the specificity of ENDOANGEL-LD for gastric lesions were 93.9% (1 685/1 795), 98.0% (789/805) and 90.5% (896/990) respectively; while the accuracy, the sensitivity and the specificity of ENDOANGEL-LD for gastric neoplastic lesions were 88.7% (714/805), 91.0% (273/300) and 87.3% (441/505) respectively. In the video testing dataset, the sensitivity [100.0% (38/38) VS 85.5% (130/152), χ2=6.220, P=0.013] of ENDOANGEL-LD was higher than that of four senior endoscopists. The accuracy [81.9% (68/83) VS 72.0% (239/332), χ2=3.408, P=0.065] and the specificity [ 66.7% (30/45) VS 60.6% (109/180), χ2=0.569, P=0.451] of ENDOANGEL-LD were comparable with those of four senior endoscopists. Conclusion:The ENDOANGEL-LD can accurately detect gastric lesions and further diagnose neoplastic lesions to help endoscopists in clinical work.
6.Application of an artificial intelligence-assisted endoscopic diagnosis system to the detection of focal gastric lesions (with video)
Mengjiao ZHANG ; Ming XU ; Lianlian WU ; Junxiao WANG ; Zehua DONG ; Yijie ZHU ; Xinqi HE ; Xiao TAO ; Hongliu DU ; Chenxia ZHANG ; Yutong BAI ; Renduo SHANG ; Hao LI ; Hao KUANG ; Shan HU ; Honggang YU
Chinese Journal of Digestive Endoscopy 2023;40(5):372-378
Objective:To construct a real-time artificial intelligence (AI)-assisted endoscepic diagnosis system based on YOLO v3 algorithm, and to evaluate its ability of detecting focal gastric lesions in gastroscopy.Methods:A total of 5 488 white light gastroscopic images (2 733 images with gastric focal lesions and 2 755 images without gastric focal lesions) from June to November 2019 and videos of 92 cases (288 168 clear stomach frames) from May to June 2020 at the Digestive Endoscopy Center of Renmin Hospital of Wuhan University were retrospectively collected for AI System test. A total of 3 997 prospective consecutive patients undergoing gastroscopy at the Digestive Endoscopy Center of Renmin Hospital of Wuhan University from July 6, 2020 to November 27, 2020 and May 6, 2021 to August 2, 2021 were enrolled to assess the clinical applicability of AI System. When AI System recognized an abnormal lesion, it marked the lesion with a blue box as a warning. The ability to identify focal gastric lesions and the frequency and causes of false positives and false negatives of AI System were statistically analyzed.Results:In the image test set, the accuracy, the sensitivity, the specificity, the positive predictive value and the negative predictive value of AI System were 92.3% (5 064/5 488), 95.0% (2 597/2 733), 89.5% (2 467/ 2 755), 90.0% (2 597/2 885) and 94.8% (2 467/2 603), respectively. In the video test set, the accuracy, the sensitivity, the specificity, the positive predictive value and the negative predictive value of AI System were 95.4% (274 792/288 168), 95.2% (109 727/115 287), 95.5% (165 065/172 881), 93.4% (109 727/117 543) and 96.7% (165 065/170 625), respectively. In clinical application, the detection rate of local gastric lesions by AI System was 93.0% (6 830/7 344). A total of 514 focal gastric lesions were missed by AI System. The main reasons were punctate erosions (48.8%, 251/514), diminutive xanthomas (22.8%, 117/514) and diminutive polyps (21.4%, 110/514). The mean number of false positives per gastroscopy was 2 (1, 4), most of which were due to normal mucosa folds (50.2%, 5 635/11 225), bubbles and mucus (35.0%, 3 928/11 225), and liquid deposited in the fundus (9.1%, 1 021/11 225).Conclusion:The application of AI System can increase the detection rate of focal gastric lesions.
7.Expert consensus for the clinical application of autologous bone marrow enrichment technique for bone repair (version 2023)
Junchao XING ; Long BI ; Li CHEN ; Shiwu DONG ; Liangbin GAO ; Tianyong HOU ; Zhiyong HOU ; Wei HUANG ; Huiyong JIN ; Yan LI ; Zhonghai LI ; Peng LIU ; Ximing LIU ; Fei LUO ; Feng MA ; Jie SHEN ; Jinlin SONG ; Peifu TANG ; Xinbao WU ; Baoshan XU ; Jianzhong XU ; Yongqing XU ; Bin YAN ; Peng YANG ; Qing YE ; Guoyong YIN ; Tengbo YU ; Jiancheng ZENG ; Changqing ZHANG ; Yingze ZHANG ; Zehua ZHANG ; Feng ZHAO ; Yue ZHOU ; Yun ZHU ; Jun ZOU
Chinese Journal of Trauma 2023;39(1):10-22
Bone defects caused by different causes such as trauma, severe bone infection and other factors are common in clinic and difficult to treat. Usually, bone substitutes are required for repair. Current bone grafting materials used clinically include autologous bones, allogeneic bones, xenografts, and synthetic materials, etc. Other than autologous bones, the major hurdles of rest bone grafts have various degrees of poor biological activity and lack of active ingredients to provide osteogenic impetus. Bone marrow contains various components such as stem cells and bioactive factors, which are contributive to osteogenesis. In response, the technique of bone marrow enrichment, based on the efficient utilization of components within bone marrow, has been risen, aiming to extract osteogenic cells and factors from bone marrow of patients and incorporate them into 3D scaffolds for fabricating bone grafts with high osteoinductivity. However, the scientific guidance and application specification are lacked with regard to the clinical scope, approach, safety and effectiveness. In this context, under the organization of Chinese Orthopedic Association, the Expert consensus for the clinical application of autologous bone marrow enrichment technique for bone repair ( version 2023) is formulated based on the evidence-based medicine. The consensus covers the topics of the characteristics, range of application, safety and application notes of the technique of autologous bone marrow enrichment and proposes corresponding recommendations, hoping to provide better guidance for clinical practice of the technique.
8.Correction to: MiR-139-5p inhibits migration and invasion of colorectal cancer by downregulating AMFR and NOTCH1.
Mingxu SONG ; Yuan YIN ; Jiwei ZHANG ; Binbin ZHANG ; Zehua BIAN ; Chao QUAN ; Leyuan ZHOU ; Yaling HU ; Qifeng WANG ; Shujuan NI ; Bojian FEI ; Weili WANG ; Xiang DU ; Dong HUA ; Zhaohui HUANG
Protein & Cell 2021;12(8):668-670
9.Influence of artificial intelligence on endoscopists′ performance in diagnosing gastric cancer by magnifying narrow banding imaging
Jing WANG ; Yijie ZHU ; Lianlian WU ; Xinqi HE ; Zehua DONG ; Manling HUANG ; Yisi CHEN ; Meng LIU ; Qinghong XU ; Honggang YU ; Qi WU
Chinese Journal of Digestive Endoscopy 2021;38(10):783-788
Objective:To assess the influence of an artificial intelligence (AI) -assisted diagnosis system on the performance of endoscopists in diagnosing gastric cancer by magnifying narrow banding imaging (M-NBI).Methods:M-NBI images of early gastric cancer (EGC) and non-gastric cancer from Renmin Hospital of Wuhan University from March 2017 to January 2020 and public datasets were collected, among which 4 667 images (1 950 images of EGC and 2 717 of non-gastric cancer)were included in the training set and 1 539 images (483 images of EGC and 1 056 of non-gastric cancer) composed a test set. The model was trained using deep learning technique. One hundred M-NBI videos from Beijing Cancer Hospital and Renmin Hospital of Wuhan University between 9 June 2020 and 17 November 2020 were prospectively collected as a video test set, 38 of gastric cancer and 62 of non-gastric cancer. Four endoscopists from four other hospitals participated in the study, diagnosing the video test twice, with and without AI. The influence of the system on endoscopists′ performance was assessed.Results:Without AI assistance, accuracy, sensitivity, and specificity of endoscopists′ diagnosis of gastric cancer were 81.00%±4.30%, 71.05%±9.67%, and 87.10%±10.88%, respectively. With AI assistance, accuracy, sensitivity and specificity of diagnosis were 86.50%±2.06%, 84.87%±11.07%, and 87.50%±4.47%, respectively. Diagnostic accuracy ( P=0.302) and sensitivity ( P=0.180) of endoscopists with AI assistance were improved compared with those without. Accuracy, sensitivity and specificity of AI in identifying gastric cancer in the video test set were 88.00% (88/100), 97.37% (37/38), and 82.26% (51/62), respectively. Sensitivity of AI was higher than that of the average of endoscopists ( P=0.002). Conclusion:AI-assisted diagnosis system is an effective tool to assist diagnosis of gastric cancer in M-NBI, which can improve the diagnostic ability of endoscopists. It can also remind endoscopists of high-risk areas in real time to reduce the probability of missed diagnosis.
10.The main causes for the missed and delayed diagnosis of endometrial carcinoma
Journal of Chinese Physician 2015;17(4):494-497
Objective To investigate the main causes of the missed and delayed diagnosis of endometrial carcinomas.Methods Endometrial carcinoma and missed and delayed diagnosis were used as key words to search in the Chinese National Knowledge Infrastructure and Wanfang Data.Results There were 37 cases with details.Among these,10 cases were caused by false negative D&C (27.0% of the total);14 cases were caused by misdiagnosis as uterine benign disease (37.8% of the total);13 cases were caused by the overlooking of the primary symptoms because of the advanced diseases.Conclusions Paying more attention to the symptoms of endometrial carcinomas is necessary to reduce the missed and delayed diagnosis of endometrial carcinoma.

Result Analysis