1.Based on LC-MS technology explored the metabolomics of Agrimonia pilosa intervening in non-small cell lung cancer A549 cells
Ze-hua TONG ; Wen-jun GUO ; Han-rui ZOU ; Li-wei XU ; Ya-juan XU ; Wei-fang WANG
Acta Pharmaceutica Sinica 2024;59(3):704-712
The objective of this study was to analyze the effects on cell viability, apoptosis, and cell cycle of non-small cell lung cancer (NSCLC) A549 cells after intervention with
2.The impact of programming optimization for atrioventricular synchrony after Micra AV leadless pacemakers implantation
Ze ZHENG ; Yu-Chen SHI ; Song-Yuan HE ; Shao-Ping WANG ; Shi-Ying LI ; Shu-Juan CHENG ; Jing-Hua LIU
Chinese Journal of Interventional Cardiology 2024;32(2):71-75
Objective To analyze the atrioventricular synchronization rate after implantation of Micra AV leadless pacemaker,and the impact of postoperative programming optimization on atrioventricular synchronization rate.Methods A prospective cohort study was conducted to select patients with complete atrioventricular block who underwent Micra AV leadless pacemaker implantation at Beijing Anzhen Hospital from August 2022 to June 2023.Programming optimization were performed at 1 week,1 month,and 3 months postoperatively,and atrioventricular synchronization rate,electrical parameters,and echocardiography were recorded.Results A total of 68 patients with complete atrioventricular block implanted with Micra AV were selected,with an average age of(68.2±9.7)years,including 47 males(69.1%).All patients were successfully implanted with Micra AV,and there were no serious postoperative complications;The average threshold,sense,and impedance parameters were stable during 1 week,1 month,and 3 months after the procedure;There was no significant difference in the EF value of postoperative echocardiography(P=0.162);The average atrioventricular synchronization rates at 1 week,1 month,and 3 months postoperatively were(75.2%vs.83.8%vs.91.6%,P=0.001).Conclusions As an mechanical atrial sensing,Micra AV requires personalized adjustment of relevant parameters;Postoperative follow-up programming optimization plays an important role in the atrioventricular synchronization and comfort level in patients with complete atrioventricular block after implantation of Micra AV leadless pacemaker.
3.A Case Report of Multidisciplinary Diagnosis and Treatment of a Patient with Tuberous Sclerosis Complex and Multi-Organ Involvement
Hua ZHENG ; Yunfei ZHI ; Lujing YING ; Lan ZHU ; Mingliang JI ; Ze LIANG ; Jiangshan WANG ; Haifeng SHI ; Weihong ZHANG ; Mengsu XIAO ; Yushi ZHANG ; Kaifeng XU ; Zhaohui LU ; Yaping LIU ; Ruiyi XU ; Huijuan ZHU ; Li WEN ; Yan ZHANG ; Gang CHEN ; Limeng CHEN
JOURNAL OF RARE DISEASES 2024;3(1):79-86
Tuberous sclerosis complex(TSC)is a rare genetic disease that can lead to benign dysplasia in multiple organs such as the skin, brain, eyes, oral cavity, heart, lungs, kidneys, liver, and bones. Its main symptoms include epilepsy, intellectual disabilities, skin depigmentation, and facial angiofibromas, whilst incidence is approximately 1 in 10 000 to 1 in 6000 newborns. This case presents a middle-aged woman who initially manifested with epilepsy and nodular depigmentation. Later, she developed a lower abdominal mass, elevated creatinine, and severe anemia. Based on clinical features and whole exome sequencing, the primary diagnosis was confirmed as TSC. Laboratory and imaging examinations revealed that the lower abdominal mass originated from the uterus. CT-guided biopsy pathology and surgical pathology suggested a combination of leiomyoma and abscess. With the involvement of multiple organs and various complications beyond the main diagnosis, the diagnostic and therapeutic process for this patient highlights the importance of rigorous clinical thinking and multidisciplinary collaboration in the diagnosis and treatment of rare and challenging diseases.
4.Research progress of lower extremity alignment in total knee arthroplasty
Zhi-Wen YIN ; Zui TIAN ; Ze-Hua WANG ; Chuan XIANG
China Journal of Orthopaedics and Traumatology 2024;37(2):214-218
Knee osteoarthritis has become one of the common diseases of the elderly,total knee arthroplasty(TKA)is the most effective treatment for end-stage knee osteoarthritis at present.In TKA,the effective restoration of the lower extremity alignment is one of the key factors for the success of the operation,which greatly affects the postoperative clinical effect and prosthesis survival rate of patients.Mechanical alignment is a TKA alignment method which is first proposed,recognized and widely used in TKA.In recent years,with the in-depth research on the lower limb alignment and the rapid development of com-puter technology,the alignment technology in TKA has realized the transformation from"unified"to"individualized",two-di-mensional to three-dimensional.New alignment methods,such as adjusted mechanical alignment,anatomic alignment,kine-matic alignment,inverse kinematic alignment,restricted kinematic alignment and functional alignment have been proposed to provide surgeons with more choices.However,there is no conclusion on which alignment method is the best choice.This paper summarizes the current research status,advantages and disadvantages of various alignment methods in TKA,and aims to pro-vide some reference for the selection of alignment methods in TKA.
5.Study on the influencing factors related with the size of vestibular schwannomas
Wen-Zhuang LI ; Ze-Ning WANG ; Guo-Hua ZHU ; Yan-Dong LI ; Dangmurenjiafu GENG
Journal of Regional Anatomy and Operative Surgery 2024;33(5):416-419
Objective To preliminarily investigate the related factors influencing the size of vestibular schwannomas.Methods The clinical data of patients with vestibular schwannomas who underwent retrosigmoid approach surgery at the department of neurosurgery of First Affiliated Hospital of Xinjiang Medical University from June 2013 to June 2023 were retrospectively analyzed.The tumor size of the patients was evaluated based on their preoperative imaging data.Univariate and multiple linear regression analyses were performed to explore the factors affecting the size of vestibular schwannomas.Results The tumor size of patients was ranging from 0.63 to 6.60 cm,with a median size of 2.97(2.20,3.80)cm.Univariate analysis showed that gender(P=0.010),ethnicity(P=0.001),age(P=0.049)and cystic solid tumor(P<0.001)were related to the size of vestibular schwannomas.Large-sized vestibular schwannomas were most commonly cystic-solid,and small and medium-sized vestibular schwannomas were most commonly solid.BMI,surgical side and place of residence were not correlated with the size of vestibular schwannomas(P>0.05).Multiple linear regression results showed that male(B=0.390,P=0.001)and Uyghur(B=0.611,P<0.001)patients were more likely to develop large tumors;with every 1-year increase in age,the maximum diameter of the tumor was reduced by an average of 0.011 cm(B=-0.011,P=0.027).Conclusion The gender,age,and ethnicity of patients are correlated with the size of vestibular schwannomas,and male,Uyghur,or younger patients were at higher risk of developing larger vestibular schwannomas.
6.Advances in actuation technology of wearable exoskeletons
Yi-Fei PENG ; Hua-Jun WANG ; Ze-Feng WANG ; PEYRODIE LAURENT ; Zhao ZHANG ; Xia HAN
Chinese Medical Equipment Journal 2024;45(4):104-110
The research status of the actuation technology of wearable exoskeletons was introduced.Kinds of actuation technologies and actuators were analyzed in terms of advantage,disadvantage and applicable scenario.It's pointed out the actuation technology of wearable exoskeletons should be oriented to high-performance micro-motors,new actuators,actuation modularity and intellectualization.[Chinese Medical Equipment Journal,2024,45(4):104-110]
7.Application research of R language-based autoregressive integrated moving average model for predicting short-term consumption of medical consumables
Ze-Hua LIU ; Hong-Tao LU ; Wei LI ; Fei WEI ; Si-Si WANG ; Xiao-Ning FU ; Xin-Ming DONG
Chinese Medical Equipment Journal 2024;45(10):84-87
Objective To explore the effect of a R language-based autoregressive integrated moving average(ARIMA)model for predicting the consumption of medical consumables.Methods The monthly consumption data of a certain type of pre-filled flush syringe from July 2018 to June 2023 was selected as the sample data,which underwent smoothness test and difference operation with R language.An ARIMA model was established and the optimal model was determined according to the Akaike and Bayesian information criteria.The corresponding data of the third quarter of 2023 was used as the validation set to predict the consumption,and the prediction result was compared with the actual values to evaluate the prediction effect of the ARIMA model.Results The ARIMA model with the best fitting was ARIMA(0,1,1)(1,0,0)12,all the predicted data were within 95%confidence interval,and its mean absolute percentage error MAPE was 9.92%.P-value proved to be higher than 0.05 when the residual series were tested using the Ljung-Box statistics,which meant the prediction result was satisfactory.Conclusion The R language-based ARIMA model behaves well in predicting the consumption of medical consumables,and provides references for demand planning,budgeting,purchasing and management of medical consumables.[Chinese Medical Equipment Journal,2024,45(10):84-87]
8.Research status of hand rehabilitation robots
Ge-Ge ZHANG ; Lian-Xin HU ; Ze-Feng WANG ; Shi-Jia HU ; Dan WANG ; Xin-Xin NI ; Hua-Jun WANG ; Shan-Qi GU
Chinese Medical Equipment Journal 2024;45(11):88-96
The current research status of different structures,driving modes and training modes of hand rehabilitation robots at home and abroad was introduced.The disadvantages of the existing hand rehabilitation robots were analyzed.It's pointed out hand rehabilitation robots in the future would involve in the combination of rigid and flexible wearing,new intelligent driving mode and multi-mode rehabilitation training.[Chinese Medical Equipment Journal,2024,45(11):88-96]
9.Bioequivalence study of rasagiline mesylate tablets in Chinese healthy subjects
Gang CHEN ; Xiao-Lin WANG ; Si-Qi ZANG ; Ze-Juan WANG ; Xiao-Na LIU ; Ai-Hua DU ; Min LI ; Ya-Nan ZHANG ; Dan ZHANG ; Li-Na ZHANG ; Jin WANG
The Chinese Journal of Clinical Pharmacology 2024;40(19):2885-2890
Objective To study the pharmacokinetics and bioequivalence of two formulations of rasagiline mesylate tablets in healthy subjects under fasting and fed conditions.Methods The two-period,two-sequence,crossover study design was adopted in the fasting study.Thirty-six subjects were enrolled and given either test preparation or reference preparation 1 mg respectively in two periods.After collecting plasma samples,the plasma concentration of rasagiline was determined by liquid chromatography-tandem mass spectrometry(LC-MS/MS)and the bioequivalence was evaluated using the average bioequivalence(ABE)method.The four-period,two-sequence,fully replicate crossover study design was adopted in the fed study.Forty-eight subjects were enrolled and given the test preparation or the reference preparation at a dose of 1 mg twice respectively in four periods.According to the degree of intra-individual variation of Cmax,AUC0-t and AUC0-∞,the equivalence was evaluated using the reference-scaled average bioequivalence and ABE method,respectively.Results In the fasting study,the pharmacokinetic parameters of rasagiline of the test and reference preparation were as follow:Cmax were(9.70±3.14)and(9.62±3.85)ng·mL-1,AUC0-t were(6.03±1.47)and(6.02±1.95)ng·h·mL-1,AUC0-∞ were(6.13±1.51)and(6.12±1.97)ng·h·mL-1.The 90%confidence interval(CI)of the geometric mean ratio(GMR)were 94.11%-118.06%,99.22%-107.74%and 99.16%-107.44%for Cmax,AUC0-t and AUC0-∞,respectively,which were within the acceptance criteria of 80.00%-125.00%.In the fed study,the pharmacokinetic parameters of rasagiline of the test and reference preparation were as follow:Cmax were(3.00±1.92)and(3.52±1.77)ng·mL-1,AUC0_t were(5.02±1.20)and(5.06±1.20)ng·h·mL-1,AUC0-∞ were(5.11±1.23)and(5.14±1.22)ng·h·mL-1.The 90%CI of GMR were 96.99%-101.19%and 97.17%-101.41%for AUC0-t and AUC0-∞,which were within the acceptance criteria of 80.00%-125.00%.The 95%upper confidence bound of Cmax for were less than"0",and the point estimate of GMR were within the acceptance criteria of 80.00%-125.00%.The incidence of adverse events in fasting and fed studies was 22.86%and 22.92%,respectively,and all adverse events were moderate to mild.Conclusion The two rasagiline mesylate tablets were bioequivalent,and both the formulations were well tolerated.
10.Transurethral resection of the prostate versus transurethral columnar balloon dilatation of the prostate in the treatment of benign prostatic hyperplasia
Zi-Peng ZHOU ; Yue-Hua DONG ; Cong-Bo WANG ; Xing-Bo ZHOU ; Ze-Man SU
National Journal of Andrology 2024;30(7):620-626
Objective:To compare the effects of transurethral resection of the prostate(TURP)and transurethral columnar bal-loon dilatation of the prostate(TUCBDP)in the treatment of BPH.Methods:This study included 218 BPH patients treated in Qin-huangdao Workers'Hospital from July 2021 to November 2022,109 by TURP and the other 109 by TUCBDP.We followed up the patients for 12 months,observed their postoperative recovery,complications,serum pain,inflammatory index,cytokine level,urodynamic index,symptom improvement and quality of life(QOL)and compared the data obtained between the two groups of patients.Results:At 12 months after surgery,the total effectiveness rate was significantly higher in the TUCBDP than in the TURP group(93.58%vs 84.40%,P<0.05),and the postoperative recovery was better in the former than in the latter(P<0.05).Compared with the baseline,the lev-els of serum prostaglandin E2(PGE2),substance P,tumor necrosis factor-alpha(TNF-α)and high sensitive C-reactive protein(hs-CRP)were remarkably increased in both of the groups on the first day after surgery(P<0.05),more significantly in the TURP than in the TUCBDP group(P<0.05),while the levels of serum PSA and E2 decreased and the T level elevated in all the patients at 3 months postoperatively(P<0.05),more significantly in the TUCBDP than in the TURP group(P<0.05).Before and at 3 and 12 months af-ter operation,the postvoid residual urine volume(PVR)and NIH-CPSI,IPSS and QOL scores showed a decreasing trend,while the maximum urinary flow rate(Qmax),maximum cystometric capacity(MCC)and maximum urethral closure pressure(MUCP)exhibited an increasing trend in both of the two groups,even more significantly in the TUCBDP than in the TURP group(P<0.05).Conclu-sion:TUCBDP is advantageous over TURP in promoting postoperative recovery,improving QOL,reducing postoperative pain,inflamma-tion and complications,regulating the levels of serum cytokines,and improving urodynamics and clinical symptoms in BPH patients.However,with the extension of postoperative time,the two strategies are basically comparable in improving the urodynamics,symptoms and QOL of the patients.

Result Analysis
Print
Save
E-mail