1.Total Arch Replacement for a Patient with Cold Agglutinin
Yuko NAKAO ; Kazuki HISATOMI ; Yutaro RYU ; Masayuki TAKURA ; Syunsuke TAGUCHI ; Hiromitsu TERATANI ; Shun NAKAJI ; Ichiro MATSUMARU ; Takashi MIURA
Japanese Journal of Cardiovascular Surgery 2025;54(1):27-30
A 74-year-old woman was scheduled for total arch replacement because of an enlarging thoracic aortic aneurysm in the aortic arch. Her preoperative blood test showed an elevated cold agglutinin with a titre of 2,048. There was concern about hemagglutination during hypothermia and hemolysis when returning to natural temperature under hypothermic circulatory arrest. We usually use moderate hypothermia (a minimum rectal temperature of 27℃) with circulatory arrest during total arch replacement. A cooling test was performed with her blood, which found no coagulation reaction in vitro at 25℃. There was a possibility that the total arch replacement would be carried out under moderate hypothermia, but it was by no means certain. After discussing the case with the hematologist, anesthetist, and clinical engineer, we decided on a minimum temperature of 30℃ during circulatory arrest because hemagglutination or hemolysis can become an issue in cardiopulmonary bypass. Coronary perfusion was maintained by infusing blood cardioplegia at 30℃ every 30 min. The intra-aortic occlusion balloon was inflated in the descending aorta, and perfusion of the spinal cord and lower body was initiated via the left femoral artery during circulatory arrest. Total selective cerebral perfusion flow was maintained at 1.5 times normal (20 ml/kg/min). There was no hemagglutination or hemolysis during the operation and no neurological complications in the postoperative period. For patients with cold agglutinin, individual cardiopulmonary bypass planning is necessary, depending on the severity of the condition and operative method.
2.A Case of Mitral Stenosis due to Pannus Formation after Mitral Valve Plasty
Tatsuya MIYANAGA ; Ichiro MATSUMARU ; Shun NAKAJI ; Kazuki HISATOMI ; Yuichi TASAKI ; Akihiko TANIGAWA ; Shunsuke TAGUCHI ; Yutaro RYU ; Yugo MURAKAMI ; Takashi MIURA
Japanese Journal of Cardiovascular Surgery 2024;53(4):203-207
A 73-year-old man had been followed up in our hospital after surgery for mitral regurgitation. At the age of 67, he underwent mitral valve plasty through a right mini-thoracotomy approach for atrial functional mitral regurgitation at our hospital. The mean trans-mitral pressure gradient was 5 mmHg after surgery but no heart failure symptoms were observed. At the age of 72, he began to notice fatigue during exertion. Transthoracic echocardiography revealed that the mitral valve regurgitation was controlled to a trace level, but the mean trans-mitral pressure gradient increased to 10 mmHg. Transesophageal echocardiography and contrast-enhanced cardiac computed tomography revealed the restricted opening of the mitral valve and pannus formation around the prosthetic ring. We thus diagnosed mitral stenosis due to pannus overgrowth. He underwent pannus excision and removal of the artificial ring. Postoperative echocardiography revealed that the mean trans-mitral pressure gradient was reduced to 3 mmHg and no residual mitral regurgitation was observed. He was discharged on postoperative day 11 with no major symptoms. He was in New York Heart Association functional class I at 1 year after the surgery and continues to be an outpatient.
3.The Utility and Feasibility of Smart Glasses in Spine Surgery: Minimizing Radiation Exposure During Percutaneous Pedicle Screw Insertion
Yoshiaki HIRANAKA ; Yoshiki TAKEOKA ; Takashi YURUBE ; Takeru TSUJIMOTO ; Yutaro KANDA ; Kunihiko MIYAZAKI ; Hiroki OHNISHI ; Tomoya MATSUO ; Masao RYU ; Naotoshi KUMAGAI ; Kohei KUROSHIMA ; Ryosuke KURODA ; Kenichiro KAKUTANI
Neurospine 2024;21(2):432-439
Objective:
Spine surgeons are often at risk of radiation exposure due to intraoperative fluoroscopy, leading to health concerns such as carcinogenesis. This is due to the increasing use of percutaneous pedicle screw (PPS) in spinal surgeries, resulting from the widespread adoption of minimally invasive spine stabilization. This study aimed to elucidate the effectiveness of smart glasses (SG) in PPS insertion under fluoroscopy.
Methods:
SG were used as an alternative screen for fluoroscopic images. Operators A (2-year experience in spine surgery) and B (9-year experience) inserted the PPS into the bilateral L1–5 pedicles of the lumbar model bone under fluoroscopic guidance, repeating this procedure twice with and without SG (groups SG and N-SG, respectively). Each vertebral body’s insertion time, radiation dose, and radiation exposure time were measured, and the deviation in screw trajectories was evaluated.
Results:
The groups SG and N-SG showed no significant difference in insertion time for the overall procedure and each operator. However, group SG had a significantly shorter radiation exposure time than group N-SG for the overall procedure (109.1 ± 43.5 seconds vs. 150.9 ± 38.7 seconds; p = 0.003) and operator A (100.0 ± 29.0 seconds vs. 157.9 ± 42.8 seconds; p = 0.003). The radiation dose was also significantly lower in group SG than in group N-SG for the overall procedure (1.3 ± 0.6 mGy vs. 1.7 ± 0.5 mGy; p = 0.023) and operator A (1.2 ± 0.4 mGy vs. 1.8 ± 0.5 mGy; p = 0.013). The 2 groups showed no significant difference in screw deviation.
Conclusion
The application of SG in fluoroscopic imaging for PPS insertion holds potential as a useful method for reducing radiation exposure.
4.Clinical Characteristics, Surgical Outcomes, and Risk Factors for Emergency Surgery in Patients With Spinal Metastases: A Prospective Cohort Study
Yutaro KANDA ; Kenichiro KAKUTANI ; Yoshitada SAKAI ; Takashi YURUBE ; Yoshiki TAKEOKA ; Kunihiko MIYAZAKI ; Hiroki OHNISHI ; Tomoya MATSUO ; Masao RYU ; Naotoshi KUMAGAI ; Kohei KUROSHIMA ; Yoshiaki HIRANAKA ; Ryosuke KURODA
Neurospine 2024;21(1):314-327
Objective:
To elucidate the patient characteristics and outcomes of emergency surgery for spinal metastases and identify risk factors for emergency surgery.
Methods:
We prospectively analyzed 216 patients with spinal metastases who underwent palliative surgery from 2015 to 2020. The Eastern Cooperative Oncology Group performance status, Barthel index, EuroQol-5 dimension (EQ5D), and neurological function were assessed at surgery and at 1, 3, and 6 months postoperatively. Multivariate analysis was performed to identify risk factors for emergency surgery.
Results:
In total, 146 patients underwent nonemergency surgery and 70 patients underwent emergency surgery within 48 hours of diagnosis of a surgical indication. After propensity score matching, we compared 61 patients each who underwent nonemergency and emergency surgery. Regardless of matching, the median performance status and the mean Barthel index and EQ5D score showed a tendency toward worse outcomes in the emergency than nonemergency group both preoperatively and 1 month postoperatively, although the surgery greatly improved these values in both groups. The median survival time tended to be shorter in the emergency than nonemergency group. The multivariate analysis showed that lesions located at T3–10 (p = 0.002; odds ratio [OR], 2.92; 95% confidence interval [CI], 1.48–5.75) and Frankel grades A–C (p < 0.001; OR, 4.91; 95% CI, 2.45–9.86) were independent risk factors for emergency surgery.
Conclusion
Among patients with spinal metastases, preoperative and postoperative subjective health values and postoperative survival are poorer in emergency than nonemergency surgery. Close attention to patients with T3–10 metastases is required to avoid poor outcomes after emergency surgery.
5.The Utility and Feasibility of Smart Glasses in Spine Surgery: Minimizing Radiation Exposure During Percutaneous Pedicle Screw Insertion
Yoshiaki HIRANAKA ; Yoshiki TAKEOKA ; Takashi YURUBE ; Takeru TSUJIMOTO ; Yutaro KANDA ; Kunihiko MIYAZAKI ; Hiroki OHNISHI ; Tomoya MATSUO ; Masao RYU ; Naotoshi KUMAGAI ; Kohei KUROSHIMA ; Ryosuke KURODA ; Kenichiro KAKUTANI
Neurospine 2024;21(2):432-439
Objective:
Spine surgeons are often at risk of radiation exposure due to intraoperative fluoroscopy, leading to health concerns such as carcinogenesis. This is due to the increasing use of percutaneous pedicle screw (PPS) in spinal surgeries, resulting from the widespread adoption of minimally invasive spine stabilization. This study aimed to elucidate the effectiveness of smart glasses (SG) in PPS insertion under fluoroscopy.
Methods:
SG were used as an alternative screen for fluoroscopic images. Operators A (2-year experience in spine surgery) and B (9-year experience) inserted the PPS into the bilateral L1–5 pedicles of the lumbar model bone under fluoroscopic guidance, repeating this procedure twice with and without SG (groups SG and N-SG, respectively). Each vertebral body’s insertion time, radiation dose, and radiation exposure time were measured, and the deviation in screw trajectories was evaluated.
Results:
The groups SG and N-SG showed no significant difference in insertion time for the overall procedure and each operator. However, group SG had a significantly shorter radiation exposure time than group N-SG for the overall procedure (109.1 ± 43.5 seconds vs. 150.9 ± 38.7 seconds; p = 0.003) and operator A (100.0 ± 29.0 seconds vs. 157.9 ± 42.8 seconds; p = 0.003). The radiation dose was also significantly lower in group SG than in group N-SG for the overall procedure (1.3 ± 0.6 mGy vs. 1.7 ± 0.5 mGy; p = 0.023) and operator A (1.2 ± 0.4 mGy vs. 1.8 ± 0.5 mGy; p = 0.013). The 2 groups showed no significant difference in screw deviation.
Conclusion
The application of SG in fluoroscopic imaging for PPS insertion holds potential as a useful method for reducing radiation exposure.
6.Clinical Characteristics, Surgical Outcomes, and Risk Factors for Emergency Surgery in Patients With Spinal Metastases: A Prospective Cohort Study
Yutaro KANDA ; Kenichiro KAKUTANI ; Yoshitada SAKAI ; Takashi YURUBE ; Yoshiki TAKEOKA ; Kunihiko MIYAZAKI ; Hiroki OHNISHI ; Tomoya MATSUO ; Masao RYU ; Naotoshi KUMAGAI ; Kohei KUROSHIMA ; Yoshiaki HIRANAKA ; Ryosuke KURODA
Neurospine 2024;21(1):314-327
Objective:
To elucidate the patient characteristics and outcomes of emergency surgery for spinal metastases and identify risk factors for emergency surgery.
Methods:
We prospectively analyzed 216 patients with spinal metastases who underwent palliative surgery from 2015 to 2020. The Eastern Cooperative Oncology Group performance status, Barthel index, EuroQol-5 dimension (EQ5D), and neurological function were assessed at surgery and at 1, 3, and 6 months postoperatively. Multivariate analysis was performed to identify risk factors for emergency surgery.
Results:
In total, 146 patients underwent nonemergency surgery and 70 patients underwent emergency surgery within 48 hours of diagnosis of a surgical indication. After propensity score matching, we compared 61 patients each who underwent nonemergency and emergency surgery. Regardless of matching, the median performance status and the mean Barthel index and EQ5D score showed a tendency toward worse outcomes in the emergency than nonemergency group both preoperatively and 1 month postoperatively, although the surgery greatly improved these values in both groups. The median survival time tended to be shorter in the emergency than nonemergency group. The multivariate analysis showed that lesions located at T3–10 (p = 0.002; odds ratio [OR], 2.92; 95% confidence interval [CI], 1.48–5.75) and Frankel grades A–C (p < 0.001; OR, 4.91; 95% CI, 2.45–9.86) were independent risk factors for emergency surgery.
Conclusion
Among patients with spinal metastases, preoperative and postoperative subjective health values and postoperative survival are poorer in emergency than nonemergency surgery. Close attention to patients with T3–10 metastases is required to avoid poor outcomes after emergency surgery.
7.The Utility and Feasibility of Smart Glasses in Spine Surgery: Minimizing Radiation Exposure During Percutaneous Pedicle Screw Insertion
Yoshiaki HIRANAKA ; Yoshiki TAKEOKA ; Takashi YURUBE ; Takeru TSUJIMOTO ; Yutaro KANDA ; Kunihiko MIYAZAKI ; Hiroki OHNISHI ; Tomoya MATSUO ; Masao RYU ; Naotoshi KUMAGAI ; Kohei KUROSHIMA ; Ryosuke KURODA ; Kenichiro KAKUTANI
Neurospine 2024;21(2):432-439
Objective:
Spine surgeons are often at risk of radiation exposure due to intraoperative fluoroscopy, leading to health concerns such as carcinogenesis. This is due to the increasing use of percutaneous pedicle screw (PPS) in spinal surgeries, resulting from the widespread adoption of minimally invasive spine stabilization. This study aimed to elucidate the effectiveness of smart glasses (SG) in PPS insertion under fluoroscopy.
Methods:
SG were used as an alternative screen for fluoroscopic images. Operators A (2-year experience in spine surgery) and B (9-year experience) inserted the PPS into the bilateral L1–5 pedicles of the lumbar model bone under fluoroscopic guidance, repeating this procedure twice with and without SG (groups SG and N-SG, respectively). Each vertebral body’s insertion time, radiation dose, and radiation exposure time were measured, and the deviation in screw trajectories was evaluated.
Results:
The groups SG and N-SG showed no significant difference in insertion time for the overall procedure and each operator. However, group SG had a significantly shorter radiation exposure time than group N-SG for the overall procedure (109.1 ± 43.5 seconds vs. 150.9 ± 38.7 seconds; p = 0.003) and operator A (100.0 ± 29.0 seconds vs. 157.9 ± 42.8 seconds; p = 0.003). The radiation dose was also significantly lower in group SG than in group N-SG for the overall procedure (1.3 ± 0.6 mGy vs. 1.7 ± 0.5 mGy; p = 0.023) and operator A (1.2 ± 0.4 mGy vs. 1.8 ± 0.5 mGy; p = 0.013). The 2 groups showed no significant difference in screw deviation.
Conclusion
The application of SG in fluoroscopic imaging for PPS insertion holds potential as a useful method for reducing radiation exposure.
8.Clinical Characteristics, Surgical Outcomes, and Risk Factors for Emergency Surgery in Patients With Spinal Metastases: A Prospective Cohort Study
Yutaro KANDA ; Kenichiro KAKUTANI ; Yoshitada SAKAI ; Takashi YURUBE ; Yoshiki TAKEOKA ; Kunihiko MIYAZAKI ; Hiroki OHNISHI ; Tomoya MATSUO ; Masao RYU ; Naotoshi KUMAGAI ; Kohei KUROSHIMA ; Yoshiaki HIRANAKA ; Ryosuke KURODA
Neurospine 2024;21(1):314-327
Objective:
To elucidate the patient characteristics and outcomes of emergency surgery for spinal metastases and identify risk factors for emergency surgery.
Methods:
We prospectively analyzed 216 patients with spinal metastases who underwent palliative surgery from 2015 to 2020. The Eastern Cooperative Oncology Group performance status, Barthel index, EuroQol-5 dimension (EQ5D), and neurological function were assessed at surgery and at 1, 3, and 6 months postoperatively. Multivariate analysis was performed to identify risk factors for emergency surgery.
Results:
In total, 146 patients underwent nonemergency surgery and 70 patients underwent emergency surgery within 48 hours of diagnosis of a surgical indication. After propensity score matching, we compared 61 patients each who underwent nonemergency and emergency surgery. Regardless of matching, the median performance status and the mean Barthel index and EQ5D score showed a tendency toward worse outcomes in the emergency than nonemergency group both preoperatively and 1 month postoperatively, although the surgery greatly improved these values in both groups. The median survival time tended to be shorter in the emergency than nonemergency group. The multivariate analysis showed that lesions located at T3–10 (p = 0.002; odds ratio [OR], 2.92; 95% confidence interval [CI], 1.48–5.75) and Frankel grades A–C (p < 0.001; OR, 4.91; 95% CI, 2.45–9.86) were independent risk factors for emergency surgery.
Conclusion
Among patients with spinal metastases, preoperative and postoperative subjective health values and postoperative survival are poorer in emergency than nonemergency surgery. Close attention to patients with T3–10 metastases is required to avoid poor outcomes after emergency surgery.
9.The Utility and Feasibility of Smart Glasses in Spine Surgery: Minimizing Radiation Exposure During Percutaneous Pedicle Screw Insertion
Yoshiaki HIRANAKA ; Yoshiki TAKEOKA ; Takashi YURUBE ; Takeru TSUJIMOTO ; Yutaro KANDA ; Kunihiko MIYAZAKI ; Hiroki OHNISHI ; Tomoya MATSUO ; Masao RYU ; Naotoshi KUMAGAI ; Kohei KUROSHIMA ; Ryosuke KURODA ; Kenichiro KAKUTANI
Neurospine 2024;21(2):432-439
Objective:
Spine surgeons are often at risk of radiation exposure due to intraoperative fluoroscopy, leading to health concerns such as carcinogenesis. This is due to the increasing use of percutaneous pedicle screw (PPS) in spinal surgeries, resulting from the widespread adoption of minimally invasive spine stabilization. This study aimed to elucidate the effectiveness of smart glasses (SG) in PPS insertion under fluoroscopy.
Methods:
SG were used as an alternative screen for fluoroscopic images. Operators A (2-year experience in spine surgery) and B (9-year experience) inserted the PPS into the bilateral L1–5 pedicles of the lumbar model bone under fluoroscopic guidance, repeating this procedure twice with and without SG (groups SG and N-SG, respectively). Each vertebral body’s insertion time, radiation dose, and radiation exposure time were measured, and the deviation in screw trajectories was evaluated.
Results:
The groups SG and N-SG showed no significant difference in insertion time for the overall procedure and each operator. However, group SG had a significantly shorter radiation exposure time than group N-SG for the overall procedure (109.1 ± 43.5 seconds vs. 150.9 ± 38.7 seconds; p = 0.003) and operator A (100.0 ± 29.0 seconds vs. 157.9 ± 42.8 seconds; p = 0.003). The radiation dose was also significantly lower in group SG than in group N-SG for the overall procedure (1.3 ± 0.6 mGy vs. 1.7 ± 0.5 mGy; p = 0.023) and operator A (1.2 ± 0.4 mGy vs. 1.8 ± 0.5 mGy; p = 0.013). The 2 groups showed no significant difference in screw deviation.
Conclusion
The application of SG in fluoroscopic imaging for PPS insertion holds potential as a useful method for reducing radiation exposure.
10.Clinical Characteristics, Surgical Outcomes, and Risk Factors for Emergency Surgery in Patients With Spinal Metastases: A Prospective Cohort Study
Yutaro KANDA ; Kenichiro KAKUTANI ; Yoshitada SAKAI ; Takashi YURUBE ; Yoshiki TAKEOKA ; Kunihiko MIYAZAKI ; Hiroki OHNISHI ; Tomoya MATSUO ; Masao RYU ; Naotoshi KUMAGAI ; Kohei KUROSHIMA ; Yoshiaki HIRANAKA ; Ryosuke KURODA
Neurospine 2024;21(1):314-327
Objective:
To elucidate the patient characteristics and outcomes of emergency surgery for spinal metastases and identify risk factors for emergency surgery.
Methods:
We prospectively analyzed 216 patients with spinal metastases who underwent palliative surgery from 2015 to 2020. The Eastern Cooperative Oncology Group performance status, Barthel index, EuroQol-5 dimension (EQ5D), and neurological function were assessed at surgery and at 1, 3, and 6 months postoperatively. Multivariate analysis was performed to identify risk factors for emergency surgery.
Results:
In total, 146 patients underwent nonemergency surgery and 70 patients underwent emergency surgery within 48 hours of diagnosis of a surgical indication. After propensity score matching, we compared 61 patients each who underwent nonemergency and emergency surgery. Regardless of matching, the median performance status and the mean Barthel index and EQ5D score showed a tendency toward worse outcomes in the emergency than nonemergency group both preoperatively and 1 month postoperatively, although the surgery greatly improved these values in both groups. The median survival time tended to be shorter in the emergency than nonemergency group. The multivariate analysis showed that lesions located at T3–10 (p = 0.002; odds ratio [OR], 2.92; 95% confidence interval [CI], 1.48–5.75) and Frankel grades A–C (p < 0.001; OR, 4.91; 95% CI, 2.45–9.86) were independent risk factors for emergency surgery.
Conclusion
Among patients with spinal metastases, preoperative and postoperative subjective health values and postoperative survival are poorer in emergency than nonemergency surgery. Close attention to patients with T3–10 metastases is required to avoid poor outcomes after emergency surgery.


Result Analysis
Print
Save
E-mail