1.Predictive value of controlling nutritional status score in the prognosis of patients with advanced diffuse large B-cell lymphoma
Huirong SHAN ; Xicheng CHEN ; Hao ZHANG ; Yuqing MIAO ; Fei WANG ; Yuye SHI ; Ling WANG ; Jingjing YE ; Ziyuan SHEN ; Wei SANG ; Hongfeng GE
Journal of Leukemia & Lymphoma 2024;33(2):104-109
Objective:To investigate the predictive value of controlling nutritional status (CONUT) score in the prognosis of patients with advanced diffuse large B-cell lymphoma (DLBCL).Methods:A retrospective case series study was performed. The clinical data of 654 patients newly diagnosed with advanced DLBCL diagnosed in 7 medical centers in Huaihai Lymphoma Working Group from October 2009 to January 2022 were retrospectively collected. All the patients received rituximab-based immune chemotherapy regimens. The patients were randomly assigned to the training set (458 cases) and the validation set (196 cases) in a 7:3 ratio. The clinicopathological data of patients were collected, and the CONUT score was calculated based on albumin, lymphocyte count, and total cholesterol. The optimal critical value of CONUT scote was determined by using MaxStat method. Kaplan-Meier method was used to draw survival curves; Cox proportional hazards model was used to make univariate analysis and multivariate analysis on the factors influencing overall survival (OS). The efficacy of CONUT score in combination with the International prognostic index (IPI) and an enhanced IPI (NCCN-IPI) in predicting OS was evaluated by using receiver operating characteristic (ROC) curves.Results:The median follow-up time of 654 patients was 38.1 months (95% CI: 35.3 months- 40.9 months), and the 5-year OS rate was 49.2%. According to the MaxStat method, the optimal critical value for CONUT score was determined to be 6 points. All the patients were classified into the normal nutritional status group (CONUT score ≤ 6 points, 489 cases) and the poor nutritional status group (CONUT score > 6 points, 165 cases). The results of the multivariate analysis showed that CONUT score > 6 points, male, lactate dehydrogenase >240 U/L, high white blood cell count, low hemoglobin level and age > 60 years were independent risk factors for OS of patients with advanced DLBCL (all P < 0.05). Patients in the poor nutritional status group (CONUT score > 6 points) had worse OS compared with that in the normal nutritional status group in the overall cohort of advanced DLBCL. Subgroup analysis revealed that among patients with Eastern Cooperative Oncology Group-performance status (ECOG PS) score < 2 points, IPI low-intermediate risk, IPI intermediate-high risk, NCCN-IPI low-intermediate risk, and NCCN-IPI intermediate-high risk, the patients in the poor nutritional status group (CONUT score > 6 points) had worse OS compared with that in the normal nutritional status group (CONUT score ≤ 6 points) (all P < 0.05). Conclusions:CONUT score has a certain value in the assessment of the prognosis of patients with advanced DLBCL, and its predictive efficacy is further improved when combined with IPI and NCCN-IPI.
2.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Effects of transdermal meridian-targeted drug delivery of Pelvic Inflammation No.1 formula on IL-10,IL-6,MMP-9 and immune function in patients with chronic pelvic inflammatory disease
Qiang FENG ; Hongmei CHEN ; Ruilian TANG ; Yuqing WU ; Yongyan YU ; Jiping YE
Chinese Journal of Immunology 2024;40(8):1735-1739
Objective:To investigate the application value of Pelvic Inflammation No.1 formula of transdermal meridian point-targeted drug delivery therapy in the treatment of patients with chronic pelvic inflammatory disease(damp-heat stasis type).Methods:All patients with chronic pelvic inflammatory disease(damp-heat stasis type)visited Danzhou Hospital of Traditional Chinese Medi-cine from August 2017 to March 2021 and were randomly grouped,57 patients in the control group were treated with simple Western medicine,and 57 patients in the observation group were combined with Pelvic Inflammation No.1 formula transdermal meridian target-ed transdermal medication,and the therapeutic efficacies were compared after 3 months of treatment.Results:After treatment,serum matrix metalloproteinase-9(MMP-9),D dimer(D-D),IL-6 and other indexes in the observation group were lower than those in the control group,and IL-10 was higher than that in the control group,the difference was statistically significant(P<0.05).After treat-ment,the carbohydrate antigen CA125 in the observation group was lower than that in the control group,and the CD4+/CD8+and CD4+cells in the observation group were higher than those in the control group(P<0.05).After treatment,the score of summary of health status surveys(SF-36)in the observation group was higher than that in the control group,and the total score of TCM symptoms was lower than that in the control group(P<0.05).The total effective rate in the observation group was 96.49%(55/57),which was higher than 82.46%(46/57)in the control group(P<0.05).Conclusion:For patients with chronic pelvic inflammatory disease(damp-heat stagnation type),combined with Pelvic Inflammation No.1 formula transdermal via acupoints targeted drug therapy can help to regu-late inflammatory factors,regulate immune function,and improve clinical efficacy.
7.Recent advance in immune inflammatory response mechanism in Japanese encephalitis
Yuanyuan LIU ; Yanzong ZHAO ; Jing YANG ; Yuqing TAN ; Shangyun ZHANG ; Jianing YE ; Handan XIAO ; Weitao WANG ; Tianhong WANG
Chinese Journal of Neuromedicine 2024;23(4):427-432
Japanese encephalitis is an acute central nervous system infectious disease caused by Japanese encephalitis virus (JEV) with brain parenchyma inflammation, characterized by high fever, headache, positive meningeal irritation, impaired consciousness, convulsion, and respiratory failure, with mortality rate as high as 20%-30%, and with neurological sequelae in 30%-50% of survivors. The mechanism of brain damage caused by JEV infection is still unclear, and some studies imply its close relation with immune-inflammatory response. This article reviews the research progress on immune-inflammatory response mechanism of Japanese encephalitis to help to understand its pathogenesis.
8.Association between smoking and ankylosing spondylitis: a Mendelian randomization study
Hong YANG ; Wei LIU ; Peiyang LUO ; Jie SONG ; Yuqing JIANG ; Zhixing HE ; Ding YE ; Yingying MAO
Journal of Preventive Medicine 2023;35(1):1-5
Objective:
To evaluate the association of smoking with the risk of ankylosing spondylitis (AS) using a Mendelian randomization (MR) approach.
Methods:
A total of 16 383 186 AS-associated single nucleotide polymorphisms (SNPs), 378 smoking initiation associated SNPs and 126 lifetime smoking score-associated SNPs were collected from three large-scale genome-wide association studies (GWAS). The association of smoking phenotypes with the risk of AS was examined using inverse-variance weighted (IVW) with AS as a outcome variable, smoking initiation and lifetime smoking score as exposure factors and SNPs with strong associations with smoking as instrumental variables, and sensitivity analyses were performed with maximum likelihood-based method, MR pleiotropy residual sum and outlier (MR-PRESSO) test and MR-Egger regression analysis.
Results:
A 33.5% increased risk of AS was found among genetically predicted smokers relative to non-smokers (OR=1.335, 95%CI: 1.059-1.682), and an increase in predicted lifetime smoking by per standard deviation resulted in a 101.4% increased risk of AS (OR=2.014, 95%CI: 1.341-3.024). The maximum likelihood-based method and MR-PRESSO test showed consistent correlated effect estimations and MR-Egger regression analysis identified no evidence of pleiotropy.
Conclusion
It is genetically predicted that smoking is associated with an increased risk of AS.
9.Predictive value of combined detection of serum HCG,D-dimer and G-CSF for pregnancy outcome in patients with recurrent implantation failure
Xuxin YE ; Zhao ZHANG ; Yuqing YUAN
International Journal of Laboratory Medicine 2023;44(24):3041-3044,3049
Objective To investigate the predictive value of serum human chorionic gonadotropin(HCG),D-dimer and granulocyte colony-stimulating factor(G-CSF)levels for pregnancy outcome in patients with re-current implantation failure(RIF).Methods A total of 80 RIF patients who underwent in vitro fertilization-embryo transfer in this hospital from May 2019 to May 2022 were selected as the research objects.According to the occurrence of adverse pregnancy outcomes,they were divided into a good pregnancy outcome group(48 cases)and a poor pregnancy outcome group(32 cases).The levels of serum HCG,D-dimer and G-CSF in RIF patients at different pregnancy stages(the day of pregnancy test,the first trimester,the second trimester and the third trimester)were detected.Spearman correlation was used to analyze the correlation between serum levels of HCG,D-dimer,and G-CSF and pregnancy outcomes.Multivariate Logistic regression was used to an-alyze the influencing factors of pregnancy outcome in patients with RIF.Receiver operating characteristic(ROC)curve was used to analyze the predictive value of serum HCG,D-dimer and G-CSF levels for pregnancy outcome in patients with RIF.Results Adverse pregnancy occurred in 32 cases of 80 patients with RIF,and preterm birth and intrauterine distress were the most common adverse pregnancy outcomes.The RIF patients with different stages of pregnancy serum HCG levels gradually decreased,serum D-dimer,G-CSF level in-creased(P<0.05).At different stages of pregnancy,the level of serum HCG in the poor pregnancy outcome group was lower than that in the good pregnancy outcome group(P<0.05),and the levels of serum D-dimer and G-CSF were higher than those in the good pregnancy outcome group(P<0.05).The level of serum HCG was negatively correlated with the adverse pregnancy outcome(r=-0.506,P<0.05),and the levels of ser-um D-dimer and G-CSF were positively correlated with the adverse pregnancy outcome(r=0.498,0.542,P<0.05).Multivariate Logistic regression analysis showed that HCG,D-dimer and G-CSF levels were the influ-encing factors of poor pregnancy outcome in patients with RIF(P<0.05).Serum HCG,D-dimer,G-CSF pa-tients with single and combined forecast RIF area under the curve of the pregnancy outcomes were 0.877,0.947,0.911 and 0.971,the sensitivity were 88.10%,88.10%,90.48%and 95.24%respectively,the specific-ity were 81.58%,97.37%,76.32%and 89.47%,respectively.The combined detection of the three markers could improve the prediction efficiency(P<0.05).Conclusion The combined detection of serum HCG,D-di-mer and G-CSF levels can effectively predict the pregnancy outcome of patients with RIF.
10.Electroacupuncture improves inflammatory reactions through HIF-1α/MDM2/p53 Signaling Pathway in Adjuvant Arthritis Rats
Yuqing JIANG ; Chengguo SU ; Haiyan ZHOU ; Jianzhen JIANG ; Jiangnan YE ; Fang LUO ; Jun ZHU
World Science and Technology-Modernization of Traditional Chinese Medicine 2023;25(10):3413-3419
Objective To observe the protective effect of electroacupuncture(EA)on ankle joint synovitis and HIF-1 α/MDM2/p53 signaling pathway in adjuvant arthritis(AA)rats.Methods SD rats were randomly divided into control group,model group,sham EA group,agonist group,EA group,EA+antagonist group,antagonist group,with 10 rats in each group.Preparation of AA rat model by injecting Freund's complete adjuvant into bilateral foot pads of rats.EA(2 Hz,3 V)was applied to bilateral ST36 and GB39 or two control points(5 mm left to ST36 and GB39)for 15 min,once every other day for a total of 8 times.HIF-1 α agonists and antagonists were injected into the tail vein of rats in the corresponding groups.The inflammatory conditions of the ankle joint were observed by HE staining,and the contents of serum HIF-1 α was assayed by ELISA.mRNA expression of HIF-1α,VEGF,MDM2 and p53 were detected by RT-PCR,protein expression of HIF-1α,VEGF,MDM2 and p53 were detected by Western blot in synovium of AA rats.Results The results of HE staining showed that compared with the control group,the synovial cells in the model group had significant proliferation and inflammatory cell infiltration(P<0.01);Compared with the model group,the arthritic reaction of the rats in the EA group,the EA+antagonist group and the antagonist group was significantly reduced(P<0.01),while the arthritic reaction of the rats in the sham EA group and the agonist group was still serious(P>0.05).The results of ELISA showed that compared with the control group,the serum HIF-1αexpression of the model group rats was significantly increased(P<0.01);Compared with model group,serum HIF-1αexpression of rats in EA group,EA+ antagonist group and antagonist group was significantly decreased(P<0.01);There was no significant difference in serum HIF-1αexpression among the model group,sham EA group and agonist group(P>0.05).RT-PCR results showed that compared with the control group,the mRNA expression of HIF-1α,VEGF,MDM2 and p53 of model group rats increased significantly;Compared with model group,the mRNA expression of HIF-1α,VEGF and MDM2 of rats in EA group,EA+antagonist group and antagonist group decreased significantly,while the mRNA expression of p53 increased significantly.Western blot results showed that compared with the control group,the protein expression of HIF-1α,VEGF,MDM2 and p53 of model group rats increased significantly;Compared with model group,the mRNA expression of HIF-1α,VEGF and MDM2 of rats in EA group,EA+antagonist group and antagonist group decreased significantly,while the mRNA expression of p53 increased significantly.Conclusion Electroacupuncture intervention has significant protective effect on ankle inflammation in AA rats,HIF-1 α/MDM2/p53 signaling pathway plays a key role in this process.


Result Analysis
Print
Save
E-mail