1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Development and Clinical Application of Multifunctional Inflation-Free Lumpectomy Aid
Mengxiang QIAO ; Gongsheng JIN ; Xianfu LIU ; Yansong CHEN ; Xiaojing ZHANG ; Hao ZHANG ; Yanfeng SUN ; Yuqing CHEN ; Ru BAI
Chinese Journal of Medical Instrumentation 2024;48(1):99-103
To investigate the value of self-developed air-free laparoscopic auxiliary instruments in the clinical application of thyroid diseases.The clinical data of 70 transaxillary and 45 transareolar air-free laparoscopic surgeries for thyroid cancer and 40 conventional open surgeries were retrospectively compared.The transaxillary and transareolar laparoscopic groups had significantly longer operative times than the open group,while the postoperative satisfaction was higher in the endoscopic group than in the open group.This set of instruments has advantage of novel design,scientific structure,safe application.It can be compatible with a variety of thyroid and breast air-free laparoscopic procedures,which can promote the development and popularization of laparoscopic technology.
6.Medium to long-term efficacy of tension-free vaginal tape procedure in the treatment of female recurrent stress urinary incontinence
Yuqing LI ; Biao WANG ; Peng QIAO ; Wei WANG ; Xing GUAN
Journal of Peking University(Health Sciences) 2024;56(4):600-604
Objective:To investigate the effectiveness and clinical efficacy of tension-free vaginal tape(TVT)surgery in treating female recurrent stress urinary incontinence(rSUI).Methods:A retrospec-tive analysis was conducted on 24 patients who experienced recurrence of mid-urethral sling failure and were treated with TVT surgery at Beijing Chao-Yang Hospital from January 2016 to June 2020.Basic pa-tient information was collected.The International Consultation on Incontinence questionnaire-short form(ICI-Q-SF)was used to record urinary incontinence symptom scores preoperatively,1-year postoperative-ly,and more than three years postoperatively.The changes in various ICI-Q-SF scores and total scores were compared.Additionally,clinical symptom severity of urinary incontinence was recorded and com-pared preoperatively and more than three years postoperatively.Results:Among the 24 patients included in the follow-up,one patient was lost to follow-up due to death from a cerebrovascular accident one year postoperatively,leaving 23 patients with a follow-up period ranging from 3.9 to 7.3 years,with an ave-rage follow-up time of(5.2±1.1)years.Preoperatively,the median ICI-Q-SF total score was 20.0(16.0,21.0);at the 1-year follow-up,the median ICI-Q-SF total score was 5.0(1.5,7.8)(P<0.001);at an average follow-up of five years,the median ICI-Q-SF total score was 6.0(3.0,9.0),still showing a statistically significant difference compared with preoperative scores(P<0.001).The in-dividual ICI-Q-SF scores were significantly lower at the 1-year and average five-year follow-ups compared with preoperative scores(P<0.001).Regarding the severity of urinary incontinence,all the patients had moderate to severe urinary incontinence preoperatively;Five years postoperatively,87.0%(20/23)of the patients had no or only mild urinary incontinence,and 13.0%(3/23)had recurrent moderate to severe urinary incontinence(P<0.001).Conclusion:TVT surgery is effective in treating female recur-rent stress urinary incontinence,with an average 5-year cure and improvement rate of 87.0%.
7.Advances in the genetics of childhood obesity
Ziwen ZHU ; Lin YOU ; Yuqing WANG ; Jing QIAO
International Journal of Pediatrics 2024;51(7):452-456
Childhood obesity is an escalating public health concern,with its prevalence rising year by year.This condition can lead to a series of metabolic disorders such as type 2 diabetes mellitus,hypertension,hyperlipidemia,and hyperuricemia.While various factors contribute to obesity,genetics plays a significant role,accounting for 40% to 70% of childhood obesity cases.Most of the identified loci harbor genes are involved in pathways affecting neuro-circuits that regulate appetite and satiety,insulin secretion and action,adipogenesis,and lipid metabolism.To date,using genome-wide association studies,over 1 100 obesity susceptibility loci have been identified,with notable examples being leptin,leptin receptor,and melanocortin-4 receptor gene.In this review,the correlation between genetic factors and childhood obesity and the possible mechanisms are elaborated to provide potential directions for its clinical management.
8.The expression changes of lncRNA in patients with systemic lupus erythematosus and its correlation with regulatory T cells
Yiqi WANG ; Jia AN ; Jun QIAO ; Ru FAN ; Yuqing LIU ; Xiaorong HU ; Fen ZHANG ; Ting CHENG ; Shengxiao ZHANG ; Junwei CHEN
Chinese Journal of Rheumatology 2022;26(9):583-589,C9-1,C9-2
Objective:To explore the link between the differentially expressed long non-coding RNAs (lncRNAs) and the number of regulatory T cells (Tregs) by detecting the lncRNAs expression profiles in patients with systemic lupus erythematosus (SLE), then analyze the correlation between Tregs and lncRNAs and the clinical features of SLE patients. We also predict the mechanism by which lncRNAs regulate the differentiation and development of Tregs, and provid new approach for the treatment of SLE.Methods:Peripheral blood of 9 active SLE patients was collected and mononuclear cells (PBMCs) were extracted. The lncRNAs expression profiles of PBMCs was analyzed by whole transcriptome sequencing. Nine healthy people served as controls to screen the differentially expressed lncRNAs, and to analyze the correlation between lncRNAs and Tregs number. Pearson test was used to analyze the correlation between lncRNA and the number of Tregs, and the correlation between Treg-associated lncRNAs and systemic lupus erythematosus disease activity index(SLEDAI) score, erythrocyte sedimentation rate (ESR), C3, C4 in SLE patients. The targeted genes of Treg asso-ciated lncRNAs were predicted with miRcode and Targetscan databases and co-expression network.Results:There were 240 differentially expressed lncRNAs in SLE patients compared with healthy controls, including 134 highly expressed lncRNAs ( P<0.05) and 106 low expressed lncRNAs ( P<0.05). The expression of ANKRD44-AS1 ( r=0.74, P=0.022), LINC00200 ( r=0.70, P=0.037), AP001363.2 ( r=0.78, P=0.014) and LINC02824 (r=0.79, P=0.011) were positively correlated with the number of Tregs, and the expression of AP000640.1 ( r=-0.72, P=0.028), AC124248.1 ( r=-0.77, P=0.016), LINC00482 ( r=-0.83, P=0.005) and MIR503HG ( r=-0.96, P<0.001) were negatively correlated with the number of Tregs. Among these eight Tregs associated lncRNAs, the expression of LINC00482 ( r=-0.73, P<0.001) and MIR503HG ( r=-0.76, P<0.001) were negatively correlated with C3. LINC00200, ANKRD44-AS1 and AP000640.1 related to Tregs regulated the expression of STAT5, PLD1, HOPX and RUNX3 through competitively binding of miRNA or transregulatory mechanism, thereby regulating the differentiation and development of Tregs. Conclusion:The lncRNAs expression profiles are changed in SLE patients, the differentially expressed lncRNAs are associated with abnormal number and function of Tregs in SLE patients, and Treg associated lncRNAs are associated with SLE disease activity, which may affect the expression of STAT5, PLD1, HOPX, RUNX3 and regulate Tregs function and participate in the pathogenesis and progression of SLE by competitively binding to miRNAs or trans-regulatory mechanism.
9.A review on cell-based models of human liver disease in vitro.
Ting LIU ; Yuqing GE ; Min YUAN ; Qiao XIONG ; Jianlong ZHAO
Journal of Biomedical Engineering 2021;38(1):178-184
Unhealthy diet, habits and drug abuse cause a variety of liver diseases, including steatohepatitis, liver fibrosis, liver cirrhosis and liver cancer, which seriously affect human health. The fabrication of highly simulated cell models in vitro is important in the treatment of liver diseases and drug development. This article summarized the common strategies for the construction of liver pathology models
Animals
;
Disease Models, Animal
;
Humans
;
Liver
;
Liver Cirrhosis/pathology*
;
Liver Neoplasms/pathology*
;
Non-alcoholic Fatty Liver Disease/pathology*
10. Advances in Study on Endoscopic Diagnosis of Helicobacter pylori Infection
Chinese Journal of Gastroenterology 2019;24(10):619-622
Helicobacter pylori (Hp) infection is closely related to many digestive tract diseases such as chronic gastritis, peptic ulcer, gastric adenocarcinoma and gastric mucosa-associated lymphoid tissue lymphoma, and early eradication of Hp can effectively improve the prognosis of these diseases. Compared with the commonly used clinical diagnostic methods, endoscopy can determine whether there is Hp infection while examining the primary disease, which is more visualized and immediate. This article reviewed the advances in study on endoscopic diagnosis of Hp infection, including standard endoscopy, magnifying endoscopy and some new technologies, such as narrow-band imaging, Fuji intelligent chromoendoscopy, I-Scan, blue laser imaging, linked color imaging, confocal laser endomicroscopy, artificial intelligence and so on.

Result Analysis
Print
Save
E-mail