1.Correlation Analysis Between Microbial Community Changes and Medicinal Quality Formation During Processing of Angelicae Dahuricae Radix
Xiaoyan CHEN ; Xinglong ZHU ; Qingxia GAN ; Jiahao WANG ; Guangqin AN ; Qinghua WU ; Jin PEI ; Yuntong MA
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(4):198-207
ObjectiveTo compare the differences in color, odor, coumarin content and microbial community composition of Angelicae Dahuricae Radix(ADR) during different drying processes, and to explore the correlation between changes in microbial community composition and changes in quality indexes of ADR. MethodsThe fresh ADR was processed at three drying temperatures(50, 70, 100 ℃) by drying and steaming cutting, semi-fresh cutting and drying, fresh cutting and drying, and sulfur fumigation methods. The color values of samples were extracted by Adobe Photoshop 2022 software and subjected to principal component analysis(PCA), electronic nose was used to identify the odor information of medicinal powders and subjected to loadings analysis, PCA, and linear discriminant analysis(LDA), and high performance liquid chromatography(HPLC) was used to determine the contents of five coumarins(bergapten, oxypeucedanin, imperatorin, phellopterin, isoimperatorin). The samples for microbial detection were taken from fresh dried samples, 50 ℃(dried and steamed cut, sulfur fumigated) samples, and 100 ℃(dried and steamed cut) samples when the water content was 50% and 14%, respectively. And the changes of microbial community composition during processing were determined by high-throughput sequencing method. The relationship between the changes of microbial community composition and the changes of odor, color and active component content of ADR during drying process was analyzed by Pearson correlation analysis. ResultsThe color quantification results showed that an increase in drying temperature led to the decrease of brightness value(L), and the increases of red-green value(a) and yellow-blue value(b), and the change of processing method had no obvious effect on the color of medicinal materials. The results of odor quantification showed that W1S, W2S, W5S, W2W and W1W sensor were sensitive to the odor changes of ADR and could be used to distinguish ADR decoction pieces from different processing methods. The results of HPLC showed that the coumarin content of ADR decreased with the increase of drying temperature and the delay of processing time, the optimal processing method was drying and steaming cutting method, and the optimal temperature was 50 ℃. High-throughput sequencing results showed that the dominant bacteria in ADR during processing were Achromobacter, Agrobacterium, Nocardioides, Mycobacterium and Enterobacter, the dominant fungi were Coprinopsis, Meyerozyma and Apiotrichum. The results of correlation analysis showed that the quality indexes of ADR were positively correlated with Agrobacterium, Mycobacterium in bacteria, Candida in fungi, and negatively correlated with Bacillus in bacteria. ConclusionThere are significant differences in the color, odor, coumarin content and microbial community composition of ADR in different drying processes, and the best drying method is drying and steaming cutting at 50 ℃. The relative abundance changes of 9 bacterial genera and 4 fungal genera are closely related to the quality formation of ADR during the drying process.
2.X-ray imaging characteristics of calcaneus in adult patients with osteoarticular diseases and its impact on disease diagnosis
Yuntong MA ; Dongyu HU ; Shengfeng SUN ; Qingquan WU ; Guangxiang LI
Chinese Journal of Endemiology 2024;43(8):666-669
Objective:To analyze the X-ray imaging characteristics of calcaneus in adult patients with osteoarticular diseases and its impact on disease diagnosis.Methods:Totally 78 patients (156 ankle joints) with osteoarticular diseases admitted to the Affiliated Hospital of Jining Medical University from June 2019 to June 2022 were selected as research subjects, including 72 cases of osteoarthritis and 6 cases of Kashin-Beck disease. Another 50 volunteers who underwent health examination in this hospital during the same period were selected as control group, all of them underwent calcaneal X-ray examination. Receiver operating characteristic (ROC) curve was used to analyze the diagnostic efficacy of calcaneal X-ray parameters in predicting adult osteoarticular diseases.Results:Among 72 patients with osteoarthritis, 63 cases (87.50%) showed joint surface sclerosis in the calcaneal X-ray changes. Forty-seven cases (65.28%) had narrowing of the subtalar joint space; 14 cases showed disappearance of the subtalar joint space, accounting for 19.44%. Among the 6 patients with Kashin-Beck disease, the X-ray changes of the calcaneus showed joint surface sclerosis in 6 cases, narrowing of the subtalar joint space in 4 cases, and disappearance of the subtalar joint space in 2 cases. The length, height, Bohler angle, Gissane angle, and inclination angle of the calcaneus in patients with Kashin-Beck disease were all smaller than those in the osteoarthritis group and the control group, the height to length ratio of the calcaneus was higher than that in the osteoarthritis group and the control group, and the difference was statistically significant ( P < 0.05). The length, height, Bohler angle, Gissane angle, and inclination angle of the calcaneus in patients of the osteoarthritis group were all smaller than those in the control group, and the height to length ratio of the calcaneus was higher than that in control group, and the difference was statistically significant ( P < 0.05). ROC curve analysis showed that the sensitivity of Bohler angle, Gissane angle, and the height to length ratio of the calcaneus in predicting osteoarticular diseases (72 patients with osteoarthritis) were 92.5%, 87.6% and 80.4%, respectively, with specificity of 73.0%, 68.8% and 63.1%, respectively. Conclusion:The calcaneal X-ray manifestations of adult patients with osteoarticular diseases vary greatly, among which Bohler angle, Gissane angle, and height to length ratio of the calcaneus have certain accuracy in diagnosis of osteoarthritis.
3.Preliminary application of volumetric-modulated arc therapy dosimetry verification system based on three-dimensional dose reconstruction of patient anatomical structures
Yangguang MA ; Rizhen MAI ; Yuntong PEI ; Yuexin GUO
Chinese Journal of Radiation Oncology 2022;31(2):170-175
Objective:To perform testing and clinical application of a volumetric-modulated arc therapy (VMAT) dosimetry verification system based on three-dimensional dose reconstruction of patient anatomical structures.Methods:ArcCheck array calibration was performed. Then, 200 MU was delivered with a 10 cm×10 cm field when the source to center of ArcCheck was 100 cm to calibrate the absolute dose and the dose was simultaneously measured by a FC65-G detector in the center of the ArcCheck. The absolute dose calibration value or the CT value of ArcCheck was adjusted to minimize the differences between the planning and measurement values of FC65-G, reconstructed value by 3DVH and reconstructed percent depth dose by 3DVH. 10 lung and 10 cervical cancer VMAT cases were selected and measured by ArcCheck and FC65-G under the delivery of a TrueBeam LINAC. The three-dimensional doses of all cases were reconstructed by 3DVH and compared with the planning and measurement values.Results:Different array calibration files of ArcCheck exerted different effect upon the two-dimensional dose measured by ArcCheck and three-dimensional dose reconstructed by 3DVH. The optimal reconstructed dose was obtained when self-calibration file was adopted and 249.96 cGy was regarded as the absolute dose calibration value. The deviations of the mean dose (D mean) and D 95% of the target were within ±4.2% and parameters of some organs at risk significantly differed compared with the reconstructed and planning dose for all cases. A negative mean point dose difference was obtained and the reconstructed dose was closer to the measured value. The γ-passing rate of the target for some cases was low, the proportion of regions irradiated by 50% prescription dose was slightly higher and the proportion of other organs was relatively high. Conclusion:The 3DVH model can be accurately established and tested with the acceptance test method in the present study, which can provide detailed information for dose verification.
4.The application and correlation study of γ rule and DVH evaluation for VMAT dose verification evaluation of cervical cancer patients
YangGuang MA ; Rizhen MAI ; Yuntong PEI ; Fangna WANG ; Lele LIU ; Yuexin GUO
Chinese Journal of Radiation Oncology 2022;31(5):450-455
Objective:To evaluate the volumetric modulated arc therapy (VMAT) dose verification of cervical cancer based on γ rule and dose volume histogram (DVH) and to perform correlation analysis between the evaluation results and the dose differences.Methods:Twenty cervical cancer VMAT plans were selected and performed on TrueBeam Linac. The delivered point and surface dose was measured by FC-65 G and ArcCheck and the results were compared to those calculated by Eclipse. The dose of patients was reconstructed by 3DVH. Then, differences between the reconstructed and plan value of D mean, D 95%, D 98% and D 2% of PTV, V 20Gy of left and right femoral head, V 40Gy of rectum, D 1cm 3 of cord, D 98%, D 2% and D 50% of the 50% prescription iso-dose volume (IDV), were evaluated and 3-dimensional (3D) γ was assessed for each organ. Lastly, Pearson’s correlation coefficient was used to analyze the relationship between point dose difference, 2D γ pass-rate (γ%), γ mean and 3D γ% of each organ and the dose difference. Results:Small differences were found between the point dose measured, reconstructed and the plan value. Differences between D mean of PTV, all dose parameters of IDV and plan values were all within 3% and V 40Gy of rectum showed the largest difference. As for the 3D γ%, the maximum pass rate was found for the left and right femoral head and the maximum variance for cord D 1cm 3. There was a moderate correlation between measured and reconstructed point dose deviation and dose difference of each organ, while no significant correlation was found for 2D γ%. Strong correlation was found between 3D γ% of target and D 50% of PTV/IDV and no correlation was found for other organs. Conclusion:The performance of both γ-and DVH-based evaluation can reveal dose error for dose verification, but both of them have some limitations and should be combined in clinical practice.
5.Evaluation the combined effect of three dose reconstruction systems on VMAT dosimetry verification of lung cancer
Yangguang MA ; Rizhen MAI ; Yuntong PEI ; Jinyan HU ; Fanyang KONG ; Xuemin WANG ; Yuexin GUO
Chinese Journal of Radiation Oncology 2021;30(1):76-80
Objective:To evaluate the combined effect of an trajectory log field based(LBF)and two commercial dose reconstruction systems on volume-modulated arc therapy(VMAT)dose verification of lung cancer.Methods:An in-house program was developed to introduce errors in trajectory log of TrueBeam to the origin plan and recalculate the dose of the error plan in treatment planning system(TPS). A total of 18 lung cancer cases treated by two-arc VMAT were selected to perform on LINAC and measured by ArcCheck simultaneously. Then, the reconstructed doses were obtained by 3DVH. The mode of reconstruction was calculated by LFB and Compass. Five of the 18 cases were performed on LINAC two times in four hours and measured by ArcCheck to evaluate the stability of the TrueBeam performance. The 18 plans were recalculated and performed on LINAC with a solid water phantom with 5 cm build-up, 4 cm back scattering thickness and a FC65-G detector in the center. The measured dose by detector was compared with the reconstructed dose by three systems.Results:TheTruebeam performance was stable. For all of the 18 cases, the point dose measured by FC65-G and reconstructed by three systems had a deviation of less than 2% to the TPS calculated. For all of the organs reconstructed by LBF and most organs reconstructed by 3DVH and Compass, the γ pass rate between them and TPS all exceeded 90% under all criteria, as well as the ArcCheck measured results. For all the organ dose difference between reconstructed and TPS, LBF system had the smallest difference, followed by the Compass system except the lung, and the 3DVH had the highest difference.Conclusions:LBF, 3DVH and Compass can reflect the VMAT dose verification results of lung cancer from different perspectives. The combined application of three systems can demonstrate the verification results in an intuitive manner, which is beneficial for subsequent analysis.
6.An integrated spectroscopic strategy to trace the geographical origins of emblic medicines:Application for the quality assessment of natural medicines
Luming QI ; Furong ZHONG ; Yang CHEN ; Shengnan MAO ; Zhuyun YAN ; Yuntong MA
Journal of Pharmaceutical Analysis 2020;10(4):356-364
Emblic medicine is a popular natural source in the world due to its outstanding healthcare and therapeutic functions. Our preliminary results indicated that the quality of emblic medicines might have an apparent regional variation. A rapid and effective geographical traceability system has not been designed yet. To trace the geographical origins so that their quality can be controlled, an integrated spectroscopic strategy including spectral pretreatment, outlier diagnosis, feature selection, data fusion, and machine learning algorithm was proposed. A featured data matrix (245 × 220) was successfully generated, and a carefully adjusted RF machine learning algorithm was utilized to develop the geographical traceability model. The results demonstrate that the proposed strategy is effective and can be generalized. Sensitivity (SEN), specificity (SPE) and accuracy (ACC) of 97.65%, 99.85% and 97.63% for the calibrated set, as well as 100.00% predictive efficiency, were obtained using this spectroscopic analysis strategy. Our study has created an integrated analysis process for multiple spectral data, which can achieve a rapid, nondestructive and green quality detection for emblic medicines originating from seventeen geographical origins.
7. A quantitative evaluation on the image-quality parameters and quality assurance thresholds setting of accelerator on-board imaging system
Jinyan HU ; Yuntong PEI ; Yangguang MA ; Haiyang WANG ; Lele LIU ; Yuexin GUO
Chinese Journal of Radiation Oncology 2019;28(12):919-923
Objective:
To achieve quantitative analysis of image quality parameters and establish warning and action thresholds for the on-board imaging (OBI) system of linear accelerator.
Methods:
The Catphan604 phantom was repeatedly scanned in the Full-Fan and Half-Fan CBCT scanning modes on a Varian EDGE linear accelerator, and the software based on Python language development in-house was utilized to analyze image quality parameters, such as CT number linearity, geometric consistency, slice thickness, spatial resolution, uniformity and low-contrast resolution. The quantitative analysis results of each image quality parameter obtained from 16 times of scanning within 16 months were normalized to the mean and the standard deviations were recorded. A run chart analysis was created to determine the warnings and action thresholds.
Results:
The software built in-house can quantitatively analyze the image parameters of the two scanning modes of OBI system. The low-contrast resolution of Half-Fan was better than that of Full-Fan, whereas the spatial resolution of Full-Fan was superior to that of Half-Fan. One standard deviation (1σ) was set as the warning threshold and 2 standard deviations (2σ) as the action threshold, respectively. The tolerance level of Half-Fan was smaller than that of Full-Fan.
Conclusion
Self-developed software enables quantitative analysis of accelerator image quality parameters, establishes warning and action tolerance of quality assurance and provides guidance for image quality assurance under image-guided radiotherapy specification.
8.A comparative analysis of Matrixx and EPID for dosimetric verification of intensity-modulated radiotherapy
Yuexin GUO ; Yuntong PEI ; Yangguang MA ; Fei JIA ; Haiyang WANG
Chinese Journal of Radiation Oncology 2017;26(6):657-660
Objective To compare the dosimetric verification results of Varian Portal Dosimetry and Matrixx,and to assess the reliability of the clinical application of electronic portal imaging device (EPID) verification.Methods Varian TrueBeam linear accelerator,which was equipped with a 120-leaf multileaf collimator and an amorphous silicon EPID,as well as portal dose prediction software.IBA I′mRT Matrixx ion chamber array was used.EPID algorithm configuration,dose calibration,and testing before use were performed.The sliding-window protocol was used.There were 77 patients with tumors involving the head and neck (mainly nasopharyngeal carcinoma),mediastinum,abdomen,and pelvic cavity were selected.The verification plan of the portal dose was created with a source-detector distance of 100 cm,and the gantry angle was kept the same as the treatment plan.The verification plan was carried out in the TrueBeam machine,and the data were collected at the same time by EPID.Comparison between the measured and calculated dose images was performed,and the evaluation standard was gamma index (3%/3 mm).The paired t-test was used for difference analysis.Results For the 77 patients,the Gamma passing rates of both methods were above 97%.Except for head and neck carcinoma were a significant difference between the results of dosimetric results using EPID and Matrixx in intensity-modulated radiotherapy (P=0.018) other remaining all P> 0.05.Conclusions The dosimetric verification results of EPID are consistent with those of Matrixx.EPID can be used for dosimetric verification,and Matrixx ion chamber array can be used only in case of a low Gamma passing rate.
9.Optimization of MSAP Reaction System forCyathula officinalisKuan and Primers Screening
Jing WEN ; Yuntong MA ; Xin CHEN ; Biqian ZHOU ; Wentao WANG ; Feng HUANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2015;(9):1860-1865
This study was aimed to establish and optimize the reaction system of MSAP for analysis on DNA methylation inCyathula officinalis Kuan of Sichuanmedicinal. The tender leaves ofC. officinalisKuan were used as materials. Orthogonal method was used in the study of main factors which affected the system quality of MSAP. The results showed that the optimal reaction systems of MSAP included: enzyme digestion (20μL), 300 ng DNA, 1.5μL EcoRI, 1.5μL HpaII or 1.5μL MspI (HpaII); ligation (25μL): 15μL digestion products, 1μL EcoR I adaptor, 1μL Hpa II/Msp I adaptor, 0.2μL T4 ligase; pre-amplication mixture (25μL): ligation products 1μL, rTaq polymerase 1 U, each primer 1.5μL, dNTP 2μL; selective amplification mixture (25μL): pre-amplification product was diluted 50 times, rTaq polymerase 1 U, each primer 1.5μL, dNTP 3μL. The optimal MSAP reaction system was used to screen for 6 pairs of effective primers from 256 pairs of primers of MSAP. It was concluded that the optimized system ensured the stable and clear bands and the screened 6 pairs of primers were with good specificity. It provided useful references for further studies of epigenetic onC. officinalisKuan DNA methylation and MSAP analysis for other medicinal plants.
10.Quality Standard for Highland Barley Monascus
Youli TAN ; Yuntong MA ; Qi LIU ; Wentao WANG ; Feng HUANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2015;17(3):614-619
This article is aimed to establish the method of quality standards for highland barley Monascus.Microscopic and TLC were adopted to identify Araliataibaiensis. Referring the relevant method in Chinese Pharmacopoeia (2010 edition) for the determination of its moisture, total ash, acid insoluble ash and extracts,lovastatin in acid and lactone form was determined using high performance liquid chromatography. The characteristics of highland barley Monascus in microscopic and TLC were obvious and specific. The contents in barley red yeast are: water 6.04%-8.78%, total ash 2.15%-2.92%, acid insoluble ash 0.23%-0.29%, water extracts 27.99%-30.17%; alcohol extracts 14.12%-18.51%. The ranges of lovastatin in acid and lactone form are 0.11%-0.29% and 0.02%-0.08%, respectively. The established method is simple, accurate, reliable and duplicable, and can be used to control the quality of highland barley Monascus.

Result Analysis