1.Application of endoscopic papillary balloon dilatation in the treatment of patients with non-dilated small choledocholithiasis
Zhenlong WANG ; Yusheng ZHANG ; Junxing YANG ; Boyi CHEN ; Yunjing DAI ; Xiaofeng LUO ; Guo-Rong DENG ; Yong YU
Chinese Journal of Hepatobiliary Surgery 2023;29(12):906-910
Objective:To study the efficacy of endoscopic papillary balloon dilatation (EPBD) in the treatment of non-dilated small choledocholithiasis.Methods:Clinical data of 142 patients with non-dilated small choledocholithiasis admitted to Zhanjiang Central People's Hospital from April 2021 to March 2023 were retrospectively analyzed, including 63 males and 79 females, aged (55.1±15.4) years old. Patients were divided into the EPBD group ( n=63) and endoscopic sphincterotomy (EST) group ( n=79). Blood amylase, liver enzymology, liver metabolism, and blood routine were monitored before and 48 hours after treatment. The occurrences of intraoperative bleeding, perforation, post-ERCP pancreatitis (PEP), and cholangitis were compared between the groups. Patients were followed up and screened for stone recurrence by outpatient review 3 to 12 months from discharge. Results:Compared to preoperative data, the white blood cell count, alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, total bili-rubin, and direct bilirubin decreased 48 hours after treatment (all P<0.05). The operation time in EPBD group was slightly longer than that in EST group [(43.1±5.9) min vs. (38.5±4.5) min, P=0.064] without statistical significance. There were no case of perforation in both groups. The incidences of intraopera-tive bleeding [3.17%(2/63) vs. 6.33%(5/79)], PEP [17.46%(11/63) vs. 10.53%(8/79)], and postoperative cholangitis [4.76%(3/63) vs. 1.27%(1/79)] were comparable between the groups (all P>0.05). Conclusion:EPBD could be feasible for non-dilated small choledocholithiasis, which does not increase the operation time and incidence of adverse events compared to EST.
2.Integrated database-based Screening Cohort for Asian Nomadic descendants in China (Scan-China): Insights on prospective ethnicity-focused cancer screening
Yuelin YU ; Liying QIAO ; Jing HAN ; Weiwei WANG ; Weiwei KANG ; Yunjing ZHANG ; Shu SHANG ; Ruogu MENG ; Lin ZHUO ; Siyan ZHAN ; Yunfeng XI ; Shengfeng WANG
Epidemiology and Health 2023;45(1):e2023048-
Established in 2017, the Screening Cohort for Asian Nomadic descendants in China (Scan-China) has benefited over 180,000 members of a multi-ethnic population, particularly individuals of Mongolian descent compared with the general population (Han ethnicity), in the Inner Mongolia Autonomous Region, China. This cohort study aims to evaluate the effectiveness of cancer screening and serve as a real-world data platform for cancer studies. The 6 most prevalent cancers in China are considered—namely, breast, lung, colorectal, gastric, liver and esophageal cancer. After baseline cancer risk assessments and screening tests, both active and passive follow-up (based on the healthcare insurance database, cancer registry, the front page of hospital medical records, and death certificates) will be conducted to trace participants’ onset and progression of cancers and other prevalent chronic diseases. Scan-China has preliminarily found a disproportionately lower screening participation rate and higher incidence/mortality rates of esophageal and breast cancer among the Mongolian population than among their Han counterparts. Further research will explore the cancer burden, natural history, treatment patterns, and risk factors of the target cancers.
3.Application effect of modified installing method of high flexion rotating platform prosthesis trial model in double compartment knee arthroplasty
Zibiao ZHAO ; Junfu DUAN ; Xuguang CHENG ; Chao SUN ; Yunjing LI ; Zilu QIN ; Bo WANG
Journal of Xinxiang Medical College 2023;40(12):1136-1139
Objective To explore the application effect of modified installing method of high flexion rotating platform prosthesis trial model in double compartment knee arthroplasty.Methods A total of 20 patients(26 knees)with severe knee osteoarthritis admitted to Hebi People's Hospital from January 2021 to April 2022 and required double compartment knee arthroplasty were selected as the research subjects.Patients were divided into the control group(10 knees)and the observation group(16 knees)based on the installing method of high flexion rotating platform prosthesis trial model.The patients in the control group used the conventional installing method of high flexion rotating platform prosthesis test model(placing the tibial side test model,the femoral side test model and finally the pad test model),while patients in the observation group used the modified installing method of high flexion rotating platform prosthesis test model(matching the femoral test model,pad and tibial test model when the patient flexed 60° to 90°,and placing them together into the knee joint osteotomy groove).The intraoperative bleeding volume and surgical time of patients in the two groups were recorded.Before surgery,2 weeks after surgery and 18 months after surgery,the knee joint function of patients was evaluated by the American hospital for special surgery(HSS)scoring system,and the range of motion(ROM)of knee joint of patients was measured by protractor.Results The intraopera-tive bleeding volume of patients in the observation group was significantly less than that in the control group,and the surgical time was significantly shorter than that in the control group(P<0.05).There was no statistically significant difference in preoperative HSS score and ROM of knee joint of patients between the two groups(P>0.05).At 2 weeks and 18 months after surgery,the HSS score and ROM of knee joint of patients in the observation group were significantly higher than those in the control group(P<0.05).Conclusion Compared with the conventional installing method of high flexion rotating platform prosthesis trial method,the modified installing method of high flexion rotating platform prosthesis trial model in double compart-ment knee arthroplasty for patients with severe knee osteoarthritis can effectively improve surgical efficiency,reduce intraopera-tive bleeding,improve knee function and increase ROM of knee joint.
4.The effects of deep-learning image reconstruction algorithm on image quality of lower extremity CT angiography with low kV and reverse flow direction scanning
Yilin CHEN ; Yuanfen LIU ; Lili WANG ; Xiongxin YE ; Yunjing XUE
Chinese Journal of Radiology 2022;56(11):1188-1194
Objective:To investigate impacts of a deep learning image reconstruction (DLIR) algorithm on image quality of lower extremity CTA with low kVp and reverse flow direction scanning.Methods:From January 2021 to March 2021, fifty patients with suspected lower extremities diseases and received lower extremity CTA with low kVp and reverse flow direction scanning in Union Hospital affiliated to Fujian Medical University were retrospectively collected in this study. Six groups of CT images were reconstructed at the thickness of 0.625 mm using two algorithms including ASIR-V of three blending ratios (ASIR-V 20%, ASIR-V 50% and ASIR-V 80%) and DLIR of three strengths (DLIR-H, DLIR-M and DLIR-L). Regions of interest (ROIs) were placed on proximal abdominal aorta (AA), distal AA, left and right common iliac arteries, left and right femoral arteries (upper segment), left and right superficial femoral arteries (middle segment), left and right popliteal arteries. The CT value and SD value were measured for each group; the signal-noise ratio (SNR) and contrast-noise ratio (CNR) were calculated. The lower extremity CTA was divided into four segments, and the subjective evaluation was independently performed on noise and sharpness using 4 points scales by two radiologists. One-way analysis of variance was utilized to evaluate the differences in subjective scoring and objective parameters among the six groups.Results:For all arteries segments, with the increase of blending ratios for ASIR-V and reconstruction strength of DLIR, the SD values were reduced while SNR and CNR were increased (all P<0.05). Among the six groups, DLIR-H and ASIR-V80% images had lowest SD as well as highest SNR and CNR (all P<0.05). In comparison to ASIR-V20% and ASIR-V50% images, DLIR-H images showed lower SD, higher SNR and CNR values (all P<0.05). There were no statistical differences between ASIR-V80% and DLIR-H images in SD, SNR and CNR values (all P>0.05). Subjective scoring results showed that the DLIR-H images displayed the best noise performance for the entire lower extremity arteries from AA to the foot artery, and the sharpness scores of DLIR-H images were also significantly higher than ASIR-V80% (all P<0.05). Conclusion:DLIR can significantly reduce the image noise and improve the image quality in CTA for abdominal aorta to lower extremity arteries. DLIR-H showed the greatest noise reduction ability and the best effect balancing noise and sharpness, providing highest image quality.
5.Analysis to early warning of blood growth differentiation factor-15 in high intensity training
Yunjing SHENG ; Qinrui XING ; Tingli WANG ; Shangqing CHANG ; Haiyan ZHU
Chinese Journal of Emergency Medicine 2021;30(6):685-688
Objective:To explore the early warning of blood growth differentiation factor-15 (GDF15) as a new stress indicator.Methods:A total of 53 armed police soldiers selected to participate in high-intensity training, measuring the soldiers' serum GDF15, high-sensitivity C-reactive protein (S-CRP), and C-reactive protein (CRP) before and after the high-intensity training , Interleukin-6 (IL-6), Procalcitonin (PCT) levels, compare the coefficient of variation of each index; use SPSS 24 software for statistical analysis, measurement data are expressed as mean ± standard deviation (Mean±SD), The comparison of measurement data adopts group t test. Results:The GDF15 level of fighters after high-intensity training was (176.28±97.45) pg/mL, which was higher than (120.35±69.87) pg/mL before high-intensity training. The difference was very significant ( P <0.001). After high-intensity training, IL-6 and CRP levels were lower than before high-intensity training, the difference was statistically significant ( P<0.05); there was no statistically significant difference in S-CRP and PCT before and after high-intensity training ( P>0.05). The coefficient of variation of GDF15 index is smaller than S-CRP, CRP, IL-6, PCT. Conclusion:Blood growth differentiation factor-15 (GDF15) is of great significance in warning the stress state after high-intensity training. It has higher sensitivity than other conventional stress indicators like S-CRP, CRP, IL-6 and PCT.
6.The value of growth differentiation factor 15 in early diagnosis of acute chest pain
Shangqing CHANG ; Yunjing SHENG ; Qinrui XING ; Kaidi YANG ; Tingli WANG ; Xiangqian GUO ; Haiyan ZHU
Chinese Journal of Emergency Medicine 2021;30(6):694-698
Objective:To explore the value of growth differentiation factor 15 (GDF15) in the early diagnosis of acute chest pain.Methods:A total of 96 patients with acute chest pain admitted to the Emergency Department of Hainan Hospital of PLA General Hospital from January to November 2020 were retrospectively collected. The sex, age, troponin T, creatine kinase, creatine kinase isoenzyme, GDF15 and B-type natriuretic peptide of patients within 30 min after admission were recorded, and the differences of each index in different groups were compared. ROC curve was drawn to evaluate the diagnostic value of GDF15 and TNT/BNP in acute coronary syndrome (ACS). The Gensini score, left ventricular ejection fraction, length of stay in hospital and the number of stents were calculated, and the correlation between these indexes and GDF15 concentration was evaluated.Results:The general trend of acute chest pain was more male than female (72.92% vs. 27.08%) , the oldest group was the UA group (64.67 ± 13.87) years old , the youngest group was cardiac arrest group (47.29 ± 9.99) years old . There were higher rates of hypertension in the STEMI group, NSTEMI group and UA group, and none of the groups showed significant advantage in diabetes. The GDF15 concentration was higher in ACS related chest pain group [(2.360 ± 1.710) ng/mL vs. (1.380 ± 1.040) ng/mL, P<0.01]. The area under the Receiver Operating Characteristic Curve (AUC) of GDF15 combined with TNT was up to 0.863. GDF15 concentration was negatively correlated with ejection fraction, positively correlated with Gensini score, positively correlated with the number of stents implanted, and positively correlated with the length of hospital stay. Conclusions:GDF15 is valuable in the diagnosis and prognosis of acute chest pain. The combination of GDF15 and TNT can improve the diagnostic rate of ACS.
7.Coexistence of ankylosing spondylitis and Beh?et's disease associated with antiphospholipid syndrome: a case report and literature review
Yajuan YAO ; Xiaoying WANG ; Yunjing BAI ; Fan WU ; Xiaohua XU ; Dexun JIANG
Chinese Journal of Rheumatology 2020;24(9):622-625
Objective:To explore the clinical features and diagnosis of coexistence of ankylosing spondylitis (AS) and Beh?et's disease associated with antiphospholipid syndrome (APS).Methods:We analyzed a case of coexistence of ankylosing spondylitis and Beh?et's disease associated with APS in Seventh Medical Center of Chinese PLA General Hospital in 2016, and the related literature were reviewed.Results:A 26-year-old male patient suffered from inflammatory low back pain, arthralgia and iritis. A His CT imaging revealed bilateral grade Ⅱ of bilateral sacroiliac arthritis. He was diagnosed as AS. He also had recurrent oral ulceration, iritis, vascular disorders and positive acupuncture pathergy test. He was diagnosed as Beh?et's disease. He suffered from recurrentpeated venous thrombosis. Laboratory tests revealed positive antiphospholipid antibodies. He was diagnosed as secondary APS complicated with Beh?et's disease. After he was treated with of glucocorticosteroid, cyclophosphamide, adalimumab and dabigatran, his condition improved significantly.Conclusion:There are some cases reported of AS with Beh?et's disease, or Beh?et's disease with APS, or AS with APS. The relationship between them is complex. The possibility of coexistence of AS and Beh?et's disease and APS should not be ignored, in order to avoid misdiagnosis.
8. Comparison of gemstone spectral curve and CT value of gastric cancer with different pathological types and differentiation degrees
Lihong CHEN ; Yunjing XUE ; Qing DUAN ; Xinming HUANG ; Lili WANG ; Guangliang CHEN
Chinese Journal of Oncology 2019;41(5):363-367
Objective:
To investigate the differences of gemstone spectral curve and CT value of gastric cancer with different pathological types and differentiation degrees.
Methods:
91 cases of preoperative gemstone CT images with gastric cancer were collected, including 24 cases of mucinous carcinoma, 67 cases of non-mucinous carcinoma, 16 cases of signet ring cell carcinoma, 8 cases of mucinous adenocarcinoma, 32 cases of moderately differentiated adenocarcinoma and 35 cases of poorly differentiated adenocarcinoma. Gemstone CT spectral imaging was performed preoperatively, and the spectral curve of the lesion in venous phase was obtained by using GSI Viewer software, the slope of the curve was calculated, and 11 monoenergetic CT values of 40~140 keV (10 keV interval) were measured. The gemstone spectral curves and CT values of gastric cancer with different pathological types and differentiation degrees are compared.
Results:
The curve slopes of non-mucinous carcinoma, signet ring cell carcinoma and poorly differentiated adenocarcinoma were -1.92±0.53, -1.73±0.37 and -2.14±0.54, respectively. The absolute values were higher than those of mucinous carcinoma (-1.45±0.54), mucinous adenocarcinoma (-0.90±0.34) and moderately differentiated adenocarcinoma (-1.67±0.41), and the differences were all statistically significant (
9.Comparison of gemstone spectral curve and CT value of gastric cancer with different pathological types and differentiation degrees
Lihong CHEN ; Yunjing XUE ; Qing DUAN ; Xinming HUANG ; Lili WANG ; Guangliang CHEN
Chinese Journal of Oncology 2019;41(5):363-367
Objective To investigate the differences of gemstone spectral curve and CT value of gastric cancer with different pathological types and differentiation degrees. Methods 91 cases of preoperative gemstone CT images with gastric cancer were collected, including 24 cases of mucinous carcinoma, 67 cases of non?mucinous carcinoma, 16 cases of signet ring cell carcinoma, 8 cases of mucinous adenocarcinoma, 32 cases of moderately differentiated adenocarcinoma and 35 cases of poorly differentiated adenocarcinoma. Gemstone CT spectral imaging was performed preoperatively, and the spectral curve of the lesion in venous phase was obtained by using GSI Viewer software, the slope of the curve was calculated, and 11 monoenergetic CT values of 40~140 keV (10 keV interval) were measured. The gemstone spectral curves and CT values of gastric cancer with different pathological types and differentiation degrees are compared. Results The curve slopes of non?mucinous carcinoma, signet ring cell carcinoma and poorly differentiated adenocarcinoma were -1.92±0.53,-1.73±0.37 and -2.14±0.54, respectively. The absolute values were higher than those of mucinous carcinoma (-1.45±0.54), mucinous adenocarcinoma (-0.90± 0.34) and moderately differentiated adenocarcinoma (-1.67±0.41), and the differences were all statistically significant (P<0.05). There were significant differences in monoenergetic CT values between mucinous and non?mucinous carcinomas at 40?140 keV ( all P<0.05). The former was lower than the latter in different degrees, and the lower the energy, the greater the difference was. There were significant differences in monoenergetic CT values between signet ring cell carcinoma and mucinous adenocarcinoma at 40?100 keV (all P<0.05); monoenergetic CT values between poorly differentiated adenocarcinoma and moderately differentiated adenocarcinoma at 40?90 keV showed statistically significant differences ( P < 0. 05 ). Conclusions Gastric cancer with different pathological types and differentiation degrees have their characteristic spectral curves in venous phase, and the monoenergetic CT values are significantly different at low energy. The spectral curve of gemstone CT may be helpful to evaluate the pathological type and differentiation degree of gastric cancer before operation.
10.Comparison of gemstone spectral curve and CT value of gastric cancer with different pathological types and differentiation degrees
Lihong CHEN ; Yunjing XUE ; Qing DUAN ; Xinming HUANG ; Lili WANG ; Guangliang CHEN
Chinese Journal of Oncology 2019;41(5):363-367
Objective To investigate the differences of gemstone spectral curve and CT value of gastric cancer with different pathological types and differentiation degrees. Methods 91 cases of preoperative gemstone CT images with gastric cancer were collected, including 24 cases of mucinous carcinoma, 67 cases of non?mucinous carcinoma, 16 cases of signet ring cell carcinoma, 8 cases of mucinous adenocarcinoma, 32 cases of moderately differentiated adenocarcinoma and 35 cases of poorly differentiated adenocarcinoma. Gemstone CT spectral imaging was performed preoperatively, and the spectral curve of the lesion in venous phase was obtained by using GSI Viewer software, the slope of the curve was calculated, and 11 monoenergetic CT values of 40~140 keV (10 keV interval) were measured. The gemstone spectral curves and CT values of gastric cancer with different pathological types and differentiation degrees are compared. Results The curve slopes of non?mucinous carcinoma, signet ring cell carcinoma and poorly differentiated adenocarcinoma were -1.92±0.53,-1.73±0.37 and -2.14±0.54, respectively. The absolute values were higher than those of mucinous carcinoma (-1.45±0.54), mucinous adenocarcinoma (-0.90± 0.34) and moderately differentiated adenocarcinoma (-1.67±0.41), and the differences were all statistically significant (P<0.05). There were significant differences in monoenergetic CT values between mucinous and non?mucinous carcinomas at 40?140 keV ( all P<0.05). The former was lower than the latter in different degrees, and the lower the energy, the greater the difference was. There were significant differences in monoenergetic CT values between signet ring cell carcinoma and mucinous adenocarcinoma at 40?100 keV (all P<0.05); monoenergetic CT values between poorly differentiated adenocarcinoma and moderately differentiated adenocarcinoma at 40?90 keV showed statistically significant differences ( P < 0. 05 ). Conclusions Gastric cancer with different pathological types and differentiation degrees have their characteristic spectral curves in venous phase, and the monoenergetic CT values are significantly different at low energy. The spectral curve of gemstone CT may be helpful to evaluate the pathological type and differentiation degree of gastric cancer before operation.

Result Analysis
Print
Save
E-mail