1.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
		                        		
		                        			 Purpose:
		                        			This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard. 
		                        		
		                        			Methods:
		                        			This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses. 
		                        		
		                        			Results:
		                        			TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710). 
		                        		
		                        			Conclusion
		                        			QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups. 
		                        		
		                        		
		                        		
		                        	
2.Effect of the Community-Based Chronic Disease Management Service Using Information and Communication Technology
Eun Jin PARK ; Yun Su LEE ; Tae Yon KIM ; Seung Hee YOO ; Hye Ran JIN ; Noor Afif MAHMUDAH ; MinSu OCK ; Tae-Yoon HWANG ; Yeong Mi KIM ; Jung Jeung LEE
Journal of Agricultural Medicine & Community Health 2024;49(3):257-270
		                        		
		                        			 Objective:
		                        			This study aimed to empirically evaluate the effectiveness of chronic disease management services utilizing ICT for patients with chronic illnesses. 
		                        		
		                        			Methods:
		                        			From May to December, 2023, 452 people who were diagnosed with hypertension and diabetes at 9 participating public health centers were provided with customized health care services for 24 weeks, and 15 performance indicators were analyzed to evaluate their effectiveness. 
		                        		
		                        			Results:
		                        			Health behavior indicators and health risk factors decreased before and after participation in the project, blood pressure control rate, hypertension and diabetes management rate, medication compliance, weight, BMI, BP, WC, FBG, and HDL-cholesterol improved(p<0.001).Service factors that influence the improvement of health behaviors included the number of activity monitor transmissions(p=0.049), confirmed concentrated consultations on physical activity(p=0.003) and nutrition(p=0.005), and the adherence to medication missions for hypertension(p=0.020).As for service factors influencing chronic disease management, the improvement in blood pressure regulation rate was due to the number of times the blood pressure monitor was linked(p=0.004), and the number of confirmed intensive consultations on physical activity(p=0.026), and nutrition(p=0.049); the improvement in hypertension control rate was due to the number of times the activity monitor and blood pressure monitor were linked(p<0.001), and the number of hypertension medication missions carried out (p=0.004); and the improvement in diabetes control rate was due to the number of times the blood pressure monitor(p=0.022) and blood sugar system were linked(p=0.017). 
		                        		
		                        			Conclusion
		                        			Although this study has limitations as a comparative study before and after the service, it has proved that chronic disease management using ICT has a positive effect on improvement of health behavior indicator, reduction of health risk factors, hypertension, diabetes management index, weight, BMI, TG, BP, FBG improvement. 
		                        		
		                        		
		                        		
		                        	
3.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
		                        		
		                        			 Purpose:
		                        			This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard. 
		                        		
		                        			Methods:
		                        			This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses. 
		                        		
		                        			Results:
		                        			TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710). 
		                        		
		                        			Conclusion
		                        			QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups. 
		                        		
		                        		
		                        		
		                        	
4.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
		                        		
		                        			 Purpose:
		                        			This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard. 
		                        		
		                        			Methods:
		                        			This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses. 
		                        		
		                        			Results:
		                        			TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710). 
		                        		
		                        			Conclusion
		                        			QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups. 
		                        		
		                        		
		                        		
		                        	
5.Effect of the Community-Based Chronic Disease Management Service Using Information and Communication Technology
Eun Jin PARK ; Yun Su LEE ; Tae Yon KIM ; Seung Hee YOO ; Hye Ran JIN ; Noor Afif MAHMUDAH ; MinSu OCK ; Tae-Yoon HWANG ; Yeong Mi KIM ; Jung Jeung LEE
Journal of Agricultural Medicine & Community Health 2024;49(3):257-270
		                        		
		                        			 Objective:
		                        			This study aimed to empirically evaluate the effectiveness of chronic disease management services utilizing ICT for patients with chronic illnesses. 
		                        		
		                        			Methods:
		                        			From May to December, 2023, 452 people who were diagnosed with hypertension and diabetes at 9 participating public health centers were provided with customized health care services for 24 weeks, and 15 performance indicators were analyzed to evaluate their effectiveness. 
		                        		
		                        			Results:
		                        			Health behavior indicators and health risk factors decreased before and after participation in the project, blood pressure control rate, hypertension and diabetes management rate, medication compliance, weight, BMI, BP, WC, FBG, and HDL-cholesterol improved(p<0.001).Service factors that influence the improvement of health behaviors included the number of activity monitor transmissions(p=0.049), confirmed concentrated consultations on physical activity(p=0.003) and nutrition(p=0.005), and the adherence to medication missions for hypertension(p=0.020).As for service factors influencing chronic disease management, the improvement in blood pressure regulation rate was due to the number of times the blood pressure monitor was linked(p=0.004), and the number of confirmed intensive consultations on physical activity(p=0.026), and nutrition(p=0.049); the improvement in hypertension control rate was due to the number of times the activity monitor and blood pressure monitor were linked(p<0.001), and the number of hypertension medication missions carried out (p=0.004); and the improvement in diabetes control rate was due to the number of times the blood pressure monitor(p=0.022) and blood sugar system were linked(p=0.017). 
		                        		
		                        			Conclusion
		                        			Although this study has limitations as a comparative study before and after the service, it has proved that chronic disease management using ICT has a positive effect on improvement of health behavior indicator, reduction of health risk factors, hypertension, diabetes management index, weight, BMI, TG, BP, FBG improvement. 
		                        		
		                        		
		                        		
		                        	
6.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
		                        		
		                        			 Purpose:
		                        			This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard. 
		                        		
		                        			Methods:
		                        			This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses. 
		                        		
		                        			Results:
		                        			TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710). 
		                        		
		                        			Conclusion
		                        			QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups. 
		                        		
		                        		
		                        		
		                        	
7.Effect of the Community-Based Chronic Disease Management Service Using Information and Communication Technology
Eun Jin PARK ; Yun Su LEE ; Tae Yon KIM ; Seung Hee YOO ; Hye Ran JIN ; Noor Afif MAHMUDAH ; MinSu OCK ; Tae-Yoon HWANG ; Yeong Mi KIM ; Jung Jeung LEE
Journal of Agricultural Medicine & Community Health 2024;49(3):257-270
		                        		
		                        			 Objective:
		                        			This study aimed to empirically evaluate the effectiveness of chronic disease management services utilizing ICT for patients with chronic illnesses. 
		                        		
		                        			Methods:
		                        			From May to December, 2023, 452 people who were diagnosed with hypertension and diabetes at 9 participating public health centers were provided with customized health care services for 24 weeks, and 15 performance indicators were analyzed to evaluate their effectiveness. 
		                        		
		                        			Results:
		                        			Health behavior indicators and health risk factors decreased before and after participation in the project, blood pressure control rate, hypertension and diabetes management rate, medication compliance, weight, BMI, BP, WC, FBG, and HDL-cholesterol improved(p<0.001).Service factors that influence the improvement of health behaviors included the number of activity monitor transmissions(p=0.049), confirmed concentrated consultations on physical activity(p=0.003) and nutrition(p=0.005), and the adherence to medication missions for hypertension(p=0.020).As for service factors influencing chronic disease management, the improvement in blood pressure regulation rate was due to the number of times the blood pressure monitor was linked(p=0.004), and the number of confirmed intensive consultations on physical activity(p=0.026), and nutrition(p=0.049); the improvement in hypertension control rate was due to the number of times the activity monitor and blood pressure monitor were linked(p<0.001), and the number of hypertension medication missions carried out (p=0.004); and the improvement in diabetes control rate was due to the number of times the blood pressure monitor(p=0.022) and blood sugar system were linked(p=0.017). 
		                        		
		                        			Conclusion
		                        			Although this study has limitations as a comparative study before and after the service, it has proved that chronic disease management using ICT has a positive effect on improvement of health behavior indicator, reduction of health risk factors, hypertension, diabetes management index, weight, BMI, TG, BP, FBG improvement. 
		                        		
		                        		
		                        		
		                        	
8.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
		                        		
		                        			 Purpose:
		                        			This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard. 
		                        		
		                        			Methods:
		                        			This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses. 
		                        		
		                        			Results:
		                        			TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710). 
		                        		
		                        			Conclusion
		                        			QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups. 
		                        		
		                        		
		                        		
		                        	
9.Trauma Exposure and Suicidal Ideation among Korean Male Firefighters: Examining the Moderating Roles of Organizational Climate
Chi-Yun BACK ; Dae-Sung HYUN ; Sei-Jin CHANG ; Da-Yee JEUNG
Safety and Health at Work 2023;14(1):71-77
		                        		
		                        			 Background:
		                        			This study investigated the relationship between trauma exposure and suicidal ideation. Moreover, this study examines the moderating roles of organizational climate on the association between trauma exposure and suicidal ideation in Korean male firefighters. 
		                        		
		                        			Methods:
		                        			A total of 15,104 male firefighters who completed a questionnaire were analyzed. The data were obtained using an online self-administered questionnaire from the Firefighter Research on Enhancement of Safety and Health Study. Poisson regression analysis was performed to determine the effects of trauma exposure on suicidal ideation and the moderating effect of organizational climate. 
		                        		
		                        			Results:
		                        			The results showed that 389 firefighters (2.6%) responded that they had experienced suicidal ideation. In the final model, trauma exposure was positively related to suicidal ideation (adjusted risk ratio [aRR], 1.076; 95% confidence interval [CI]: 1.051–1.103), and organizational climate was negatively associated with suicidal ideation (aRR, 0.772; 95% CI: 0.739–0.806). Additionally, the interaction term (trauma exposure × organizational climate) was related to suicidal ideation (aRR, 1.016; 95% CI: 1.009–1.023). 
		                        		
		                        			Conclusions
		                        			This study suggests that trauma exposure might play a significant role in developing suicidal ideation and that positive organizational climate moderates the negative effects of trauma exposure on suicidal ideation among firefighters. It is necessary to perform a follow-up study of various intervention strategies to maintain a healthy organizational climate or work environment. Such interventions should promote lasting trust within teams, provide social support and belonging, and nurture job value. 
		                        		
		                        		
		                        		
		                        	
10.Intranasal Vaccination with OuterMembrane Protein of Orientia tsutsugamushi induces Protective Immunity Against Scrub Typhus
Sung-Moo PARK ; Min Jeong GU ; Young-Jun JU ; In Su CHEON ; Kyu-Jam HWANG ; Byoungchul GILL ; Byoung-Shik SHIM ; Hang-Jin JEONG ; Young Min SON ; Sangho CHOI ; Woonhee JEUNG ; Seung Hyun HAN ; Hyuk CHU ; Cheol-Heui YUN
Immune Network 2021;21(2):e14-
		                        		
		                        			
		                        			 Scrub typhus develops after the individual is bitten by a trombiculid mite infected with Orientia tsutsugamushi. Since it has been reported that pneumonia is frequently observed in patients with scrub typhus, we investigated whether intranasal (i.n.) vaccination with the outer membrane protein of O. tsutsugamushi (OMPOT) would induce a protective immunity against O. tsutsugamushi infection. It was particular interest that when mice were infected with O. tsutsugamushi, the bacteria disseminated into the lungs, causing pneumonia. The i.n. vaccination with OMPOT induced IgG responses in serum and bronchoalveolar lavage (BAL) fluid. The anti-O. tsutsugamushi IgA Abs in BAL fluid after the vaccination showed a high correlation of the protection against O. tsutsugamushi. The vaccination induced strong Ag-specific Th1 and Th17 responses in the both spleen and lungs. In conclusion, the current study demonstrated that i.n. vaccination with OMPOT elicited protective immunity against scrub typhus in mouse with O. tsutsugamushi infection causing subsequent pneumonia. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail