1.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
2.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
3.Resveratrol attenuates aging-induced mitochondrial dysfunction and mitochondria-mediated apoptosis in the rat heart
Youngju CHOI ; Mi-Hyun NO ; Jun-Won HEO ; Eun-Jeong CHO ; Dong-Ho PARK ; Ju-Hee KANG ; Chang-Ju KIM ; Dae Yun SEO ; Jin HAN ; Hyo-Bum KWAK
Nutrition Research and Practice 2025;19(2):186-199
RESULTS:
Resveratrol significantly reduced cardiac hypertrophy and remodeling in aging hearts. In addition, resveratrol significantly ameliorated aging-induced mitochondrial dysfunction (e.g., decreased oxygen respiration and increased hydrogen peroxide emission) and mitochondria-dependent apoptotic signaling (the Bax/Bcl-2 ratio, mitochondrial permeability transition pore opening sensitivity, and cleaved caspase-3 protein levels).Resveratrol also significantly attenuated aging-induced apoptosis (determined via cleaved caspase-3 staining and TUNEL-positive myonuclei) in cardiac muscles.
CONCLUSION
This study demonstrates that resveratrol treatment has a beneficial effect on aging-induced cardiac remodeling by ameliorating mitochondrial dysfunction and inhibiting mitochondria-mediated apoptosis in the heart.
4.Clinical evaluation and management of endometriosis: 2024 guideline for Korean patients from the Korean Society of Endometriosis
Hyun Joo LEE ; Sang-Hee YOON ; Jae Hoon LEE ; Youn-Jee CHUNG ; So Yun PARK ; Sung Woo KIM ; Yeon Hee HONG ; Sung Eun KIM ; Youjin KIM ; Sungwook CHUN ; Yong Jin NA
Obstetrics & Gynecology Science 2025;68(1):43-58
Endometriosis, a prevalent but debilitating condition affecting women, poses significant challenges in diagnosis and management. The current 2024 guideline, developed by the Korean Society of Endometriosis (KSE), builds upon the 2018 KSE guideline. This guideline aims to provide customized recommendations tailored to Korea’s unique clinical aspects and medical environment, and addresses key areas such as diagnosis, medical and surgical management, considerations for special populations, and its complex relationship with cancer.
5.The impact of the laboratory quality management program on colorectal cancer screening using immunochemical fecal occult blood tests in Korea
Hye Ryun LEE ; Sollip KIM ; Hyeongsu KIM ; Yeo-Min YUN ; Ho Jin JEONG ; Minje HAN ; Myeong Hee KIM ; Tae-Hyun UM ; You Kyoung LEE ; Byung Ryul JEON ; Kunsei LEE ; Sail CHUN
Journal of the Korean Medical Association 2025;68(5):338-347
Purpose:
Immunochemical fecal occult blood tests (iFOBT) have been utilized as the primary method for colorectal cancer screening within Korea's National Cancer Screening Program. This study aimed to evaluate the impact of the accreditation program for clinical laboratories and external quality assessment (EQA) programs on colorectal cancer screening.
Methods:
We analyzed the false-positive rates of iFOBT in colorectal cancer screening from 2016 to 2020 according to participation and performance in the Outstanding Laboratory Accreditation Program (OLAP) conducted by the Laboratory Medicine Foundation, and the External Quality Assessment programs run by the Korean Association of External Quality Assessment Service.
Results:
False-positive rates of iFOBT were lower among institutions accredited by OLAP (2.35%) compared with non-accredited (3.04%) and non-participating institutions (5.60%). Similarly, institutions participating in the EQA program exhibited lower false-positive rates (3.79%) compared to non-participants (7.04%). Within the iFOBT-specific EQA program, institutions that passed demonstrated the lowest false-positive rate (3.37%), while failing institutions showed the highest rate (9.07%), surpassing even non-participating institutions (6.44%).
Conclusion
Participation in quality management programs such as OLAP and EQA was associated with lower false-positive rates in iFOBT for colorectal cancer screening. These findings suggest that quality management initiatives can increase the accuracy of iFOBT, potentially improving the effectiveness of colorectal cancer screening programs, and reducing unnecessary follow-up procedures and associated healthcare costs.
6.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
7.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
8.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
9.Validation of the Korean Version of the Huntington’s Disease Quality of Life Battery for Carers
Hee Jin CHANG ; Eungseok OH ; Won Tae YOON ; Chan Young LEE ; Kyum-Yil KWON ; Yun Su HWANG ; Chaewon SHIN ; Jee-Young LEE
Journal of Movement Disorders 2025;18(2):160-164
Objective:
The Huntington’s Disease Quality of Life Battery for Carers (HDQoL-C) is used to evaluate caregiver quality of life. This study aimed to develop and validate the Korean version of the HDQoL-C (K-HDQoL-C) to assess the burden on Korean caregivers of Huntington’s disease (HD) patients.
Methods:
A total of 19 HD caregivers (7 females, mean age 55.4±14.6 years) participated in this study. The K-HDQoL-C, a translation of the English version, consisted of demographic information, caring aspects, life satisfaction, and feelings about life. It was administered twice, 2 weeks apart. Internal consistency was evaluated using Cronbach’s α, and test-retest reliability was assessed with intraclass correlation coefficients. The relationship with the Zarit Burden Interview-12 (ZBI-12) was analyzed.
Results:
The internal consistencies of the K-HDQoL-C were 0.771 (part 2), 0.938 (part 3), and 0.891 (part 4). The test-retest reliability ranged from 0.908 to 0.936. Part 3 was negatively correlated with the ZBI-12, and part 4 was positively correlated with the ZBI-12 (r=-0.780, 0.923; p<0.001).
Conclusion
The K-HDQoL-C effectively evaluates the challenges faced by HD caregivers, particularly in terms of care aspects and life satisfaction.
10.Effects of Anti-Obesity Strategies on Bone Mineral Density: A Comprehensive Meta-Analysis of Randomized Controlled Trials
Myung Jin KIM ; Seonok KIM ; Han Na JUNG ; Chang Hee JUNG ; Woo Je LEE ; Yun Kyung CHO
Journal of Obesity & Metabolic Syndrome 2025;34(1):41-53
Background:
Although an appropriate weight management strategy is essential for obese individuals, weight loss can have adverse effects on bone mineral density (BMD). We conducted a systematic review of randomized controlled trials to evaluate changes in BMD after the implementation of various weight loss strategies.
Methods:
The PubMed, Embase, Web of Science, and Cochrane Library databases were searched to find articles published from database inception until June 2023. Randomized controlled trials of various treatments for obese patients that reported changes in BMD were selected. The primary outcome was BMD of the whole body, lumbar spine, and total hip, measured using dual X-ray absorptiometry.
Results:
Eighteen randomized controlled trials involving 2,510 participants with obesity were included in the analysis. At follow-up examination, the BMD of the lumbar spine decreased significantly after metabolic surgery (mean difference [MD]= –0.40 g/cm2 ; 95% confidence interval [CI], –0.73 to –0.07; I2 = 0%); lifestyle and pharmacological interventions did not result in a significant decrease in BMD at any location. Metabolic surgery also produced the most substantial difference in weight, with an MD of –3.14 (95% CI, –3.82 to –2.47).
Conclusion
This meta-analysis is the first to examine the effects of all categories of anti-obesity strategies, including the use of anti-obesity medications, on BMD. Bariatric metabolic surgery can have adverse effects on BMD. Moreover, medications can be used as a treatment for weight loss without compromising bone quality.

Result Analysis
Print
Save
E-mail