1.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
2.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
3.The KAPARD guidelines for atopic dermatitis in children and adolescents:Part II. Systemic treatment, novel therapeutics, and adjuvant therapy
Hwan Soo KIM ; Eun LEE ; Kyunghoon KIM ; Taek Ki MIN ; Dong In SUH ; Yoon Ha HWANG ; Sungsu JUNG ; Minyoung JUNG ; Young A PARK ; Minji KIM ; In Suk SOL ; You Hoon JEON ; Sung-Il WOO ; Yong Ju LEE ; Jong Deok KIM ; Hyeon-Jong YANG ; Gwang Cheon JANG ;
Allergy, Asthma & Respiratory Disease 2025;13(1):3-11
Atopic dermatitis is the most common chronic inflammatory skin disease in children and adolescents. The Korean Academy of Pediatric Allergy and Respiratory Disease published the Atopic Dermatitis Treatment Guideline in 2008, which has been helpful in atopic dermatitis treatment until now. Various reports on the development and effectiveness of new drugs have suggested that there is a need to develop and revise old treatment guidelines. Part 1 aimed to provide evidence-based recommendations for skin care management and topical treatment for atopic dermatitis. Part 2 focuses on systemic treatment, novel therapeutics, and adjuvant therapy. The goal of this guideline is intended to assist front-line doctors treating pediatric and adolescent atopic dermatitis patients make safer, more effective, and more rational decisions regarding systemic treatment, novel therapeutics, and adjuvant therapy by providing evidence-based recommendations with a clear level of evidence and benefit regarding treatment.
4.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
5.The relationship between self-rating of subjective oral health, oral hygiene behaviors, and objective oral health status: a retrospective study
Hye-Won SEO ; Young-Taek KIM ; Bo-Ah LEE
Journal of Korean Academy of Oral Health 2025;49(1):12-17
Objectives:
To investigate the relationship between self-rating of subjective oral health, oral hygiene behaviors, and objective oral health status, and to identify factors that determine self-rating for subjective oral health.
Methods:
This retrospective study examined data from 1,128 patients who underwent panoramic radiography and oral examination based on national health checkups between 2009 and 2015. Oral hygiene behavior was validated using a questionnaire, and the presence of oral diseases was validated through oral examination and panoramic radiographs. The effect of oral hygiene behaviors on the presence of oral diseases or dental treatment was evaluated using univariate regression analysis. Oral hygiene behaviors and the prevalence of oral disease were compared, according to selfrated subjective oral health, using the chi-square test. Factors affecting self-rating of subjective oral health were determined using multivariate regression analysis.
Results:
Patients who brushed their teeth less than three times per day had a higher risk of dental caries, periodontitis, and missing teeth (P<0.05). The percentage of patients performing oral hygiene behaviors differed significantly according to the self-rating of subjective oral health. The factors affecting the self-rating of subjective oral health were pain and the presence of restored teeth.The presence of gingivitis, periodontitis, and the number of dental caries had no significant effect on the self-rating of oral health.
Conclusions
Self-rating of oral health was determined by treatment experience rather than objective oral health status and it affected oral hygiene behavior.
6.The relationship between self-rating of subjective oral health, oral hygiene behaviors, and objective oral health status: a retrospective study
Hye-Won SEO ; Young-Taek KIM ; Bo-Ah LEE
Journal of Korean Academy of Oral Health 2025;49(1):12-17
Objectives:
To investigate the relationship between self-rating of subjective oral health, oral hygiene behaviors, and objective oral health status, and to identify factors that determine self-rating for subjective oral health.
Methods:
This retrospective study examined data from 1,128 patients who underwent panoramic radiography and oral examination based on national health checkups between 2009 and 2015. Oral hygiene behavior was validated using a questionnaire, and the presence of oral diseases was validated through oral examination and panoramic radiographs. The effect of oral hygiene behaviors on the presence of oral diseases or dental treatment was evaluated using univariate regression analysis. Oral hygiene behaviors and the prevalence of oral disease were compared, according to selfrated subjective oral health, using the chi-square test. Factors affecting self-rating of subjective oral health were determined using multivariate regression analysis.
Results:
Patients who brushed their teeth less than three times per day had a higher risk of dental caries, periodontitis, and missing teeth (P<0.05). The percentage of patients performing oral hygiene behaviors differed significantly according to the self-rating of subjective oral health. The factors affecting the self-rating of subjective oral health were pain and the presence of restored teeth.The presence of gingivitis, periodontitis, and the number of dental caries had no significant effect on the self-rating of oral health.
Conclusions
Self-rating of oral health was determined by treatment experience rather than objective oral health status and it affected oral hygiene behavior.
7.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
8.The KAPARD guidelines for atopic dermatitis in children and adolescents:Part II. Systemic treatment, novel therapeutics, and adjuvant therapy
Hwan Soo KIM ; Eun LEE ; Kyunghoon KIM ; Taek Ki MIN ; Dong In SUH ; Yoon Ha HWANG ; Sungsu JUNG ; Minyoung JUNG ; Young A PARK ; Minji KIM ; In Suk SOL ; You Hoon JEON ; Sung-Il WOO ; Yong Ju LEE ; Jong Deok KIM ; Hyeon-Jong YANG ; Gwang Cheon JANG ;
Allergy, Asthma & Respiratory Disease 2025;13(1):3-11
Atopic dermatitis is the most common chronic inflammatory skin disease in children and adolescents. The Korean Academy of Pediatric Allergy and Respiratory Disease published the Atopic Dermatitis Treatment Guideline in 2008, which has been helpful in atopic dermatitis treatment until now. Various reports on the development and effectiveness of new drugs have suggested that there is a need to develop and revise old treatment guidelines. Part 1 aimed to provide evidence-based recommendations for skin care management and topical treatment for atopic dermatitis. Part 2 focuses on systemic treatment, novel therapeutics, and adjuvant therapy. The goal of this guideline is intended to assist front-line doctors treating pediatric and adolescent atopic dermatitis patients make safer, more effective, and more rational decisions regarding systemic treatment, novel therapeutics, and adjuvant therapy by providing evidence-based recommendations with a clear level of evidence and benefit regarding treatment.
9.The KAPARD guidelines for atopic dermatitis in children and adolescents:Part II. Systemic treatment, novel therapeutics, and adjuvant therapy
Hwan Soo KIM ; Eun LEE ; Kyunghoon KIM ; Taek Ki MIN ; Dong In SUH ; Yoon Ha HWANG ; Sungsu JUNG ; Minyoung JUNG ; Young A PARK ; Minji KIM ; In Suk SOL ; You Hoon JEON ; Sung-Il WOO ; Yong Ju LEE ; Jong Deok KIM ; Hyeon-Jong YANG ; Gwang Cheon JANG ;
Allergy, Asthma & Respiratory Disease 2025;13(1):3-11
Atopic dermatitis is the most common chronic inflammatory skin disease in children and adolescents. The Korean Academy of Pediatric Allergy and Respiratory Disease published the Atopic Dermatitis Treatment Guideline in 2008, which has been helpful in atopic dermatitis treatment until now. Various reports on the development and effectiveness of new drugs have suggested that there is a need to develop and revise old treatment guidelines. Part 1 aimed to provide evidence-based recommendations for skin care management and topical treatment for atopic dermatitis. Part 2 focuses on systemic treatment, novel therapeutics, and adjuvant therapy. The goal of this guideline is intended to assist front-line doctors treating pediatric and adolescent atopic dermatitis patients make safer, more effective, and more rational decisions regarding systemic treatment, novel therapeutics, and adjuvant therapy by providing evidence-based recommendations with a clear level of evidence and benefit regarding treatment.
10.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.

Result Analysis
Print
Save
E-mail