1.Aspiration Patterns Observed in Patients With Free Flap Reconstruction Following T3 and T4 Tongue and Oropharyngeal Cancer Surgery: A Fiberoptic Endoscopic Evaluation of Swallowing
Bo Hae KIM ; Eun-Jae CHUNG ; Young-Soo RHO
Korean Journal of Otolaryngology - Head and Neck Surgery 2022;65(3):157-163
Background and Objectives:
The objectives of this study were to investigate the aspiration patterns in patients with T3 and T4 oral and oropharyngeal cancers after free flap reconstruction following primary tumor resection and determine the effect of tongue base resection on aspiration patterns in these patients.Subjects and Method The aspiration pattern was evaluated via fiberoptic endoscopic evaluation of swallowing and classified into three groups based on the timing of aspiration in relation to the swallowing process. More than two types of aspiration patterns observed simultaneously in a patient suggested combined aspiration pattern.
Results:
The major pattern of aspiration in 31 patients with oral cavity cancer was aspiration after swallowing in the group with base of tongue (BOT) preserved (83.3%, 10/12) and combined aspiration in the group with BOT resection (63.2%, 12/19), showing a significant difference in aspiration pattern between the two groups (p<0.001). In oropharyngeal malignancies, the major pattern of aspiration was aspiration after swallowing in both BOT-preserving (87.5%, 21/24) and BOT-resecting groups (75.0%, 9/12), showing a significant difference in aspiration pattern between the two groups (p=0.031).
Conclusion
The most common pattern observed in the advanced T stage tongue cancer patients after glossectomy was aspiration after swallowing. Resection of BOT greater than 25% in the tongue and oropharyngeal cancer was a significant factor causing the combined type of aspiration.
2.Comparison of the Optimized Intraocular Lens Constants Calculated by Automated and Manifest Refraction for Korean
Youngsub EOM ; Dong Hui LIM ; Dong Hyun KIM ; Yong-Soo BYUN ; Kyung Sun NA ; Seong-Jae KIM ; Chang Rae RHO ; So-Hyang CHUNG ; Ji Eun LEE ; Kyong Jin CHO ; Tae-Young CHUNG ; Eun Chul KIM ; Young Joo SHIN ; Sang-Mok LEE ; Yang Kyung CHO ; Kyung Chul YOON ; In-Cheon YOU ; Byung Yi KO ; Hong Kyun KIM ; Jong Suk SONG ; Do Hyung LEE
Journal of the Korean Ophthalmological Society 2022;63(9):747-753
Purpose:
To derive the optimized intraocular lens (IOL) constants from automated and manifest refraction after cataract surgery in Korean patients, and to evaluate whether there is a difference in optimized IOL constants according to the refraction method.
Methods:
This retrospective multicenter cohort study enrolled 4,103 eyes of 4,103 patients who underwent phacoemulsification and in-the-bag IOL implantation at 18 institutes. Optimized IOL constants for the SRK/T, Holladay, Hoffer Q, and Haigis formulas were calculated via autorefraction or manifest refraction of samples using the same biometry and IOL. The IOL constants derived from autorefraction and manifest refraction were compared.
Results:
Of the 4,103 eyes, the majority (62.9%) were measured with an IOLMaster 500 followed by an IOLMaster 700 (15.2%). A total of 33 types of IOLs were used, and the Tecnis ZCB00 was the most frequently used (53.0%). There was no statistically significant difference in IOL constants derived from autorefraction and manifest refraction when IOL constants were optimized with a large number of study subjects. On the other hand, optimized IOL constants derived from autorefraction were significantly smaller than those from manifest refraction when the number of subjects was small.
Conclusions
It became possible to use the IOL constants optimized from Koreans to calculate the IOL power. However, if the IOL constant is optimized using autorefraction in a small sample group, the IOL constant tends to be small, which may lead to refractive error after surgery.
3.Descemet Membrane Endothelial Keratoplasty after Penetrating Keratoplasty Graft Failure
Woo Young SON ; Min Ji HA ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Chang Rae RHO ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2021;62(6):848-854
Purpose:
To report a case of a successful secondary Descemet membrane endothelial keratoplasty in failed penetrating keratoplasty. Case summary: A 46-year-old male with keratoconus in both of his eyes underwent penetrating keratoplasty in his right eye 30 years ago and in his left eye 14 years ago. From one and a half year ago, the patient’s visual acuity decreased in his left eye due to graft failure. For treatment, secondary Descemet membrane endothelial keratoplasty was performed. Partial detachment of Descemet membrane was observed at 13 days after the operation, and an additional air injection was performed. At 8 months after the operation, the patient’s uncorrected visual acuity improved to 0.5 and the cornea maintained its clearance without rejection.
Conclusions
Secondary Descemet membrane endothelial keratoplasty was successfully performed in a patient with failed penetrating keratoplasty.
4.Descemet Membrane Endothelial Keratoplasty after Penetrating Keratoplasty Graft Failure
Woo Young SON ; Min Ji HA ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Chang Rae RHO ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2021;62(6):848-854
Purpose:
To report a case of a successful secondary Descemet membrane endothelial keratoplasty in failed penetrating keratoplasty. Case summary: A 46-year-old male with keratoconus in both of his eyes underwent penetrating keratoplasty in his right eye 30 years ago and in his left eye 14 years ago. From one and a half year ago, the patient’s visual acuity decreased in his left eye due to graft failure. For treatment, secondary Descemet membrane endothelial keratoplasty was performed. Partial detachment of Descemet membrane was observed at 13 days after the operation, and an additional air injection was performed. At 8 months after the operation, the patient’s uncorrected visual acuity improved to 0.5 and the cornea maintained its clearance without rejection.
Conclusions
Secondary Descemet membrane endothelial keratoplasty was successfully performed in a patient with failed penetrating keratoplasty.
5.Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels
Yon-Kwon IHN ; Bum-soo KIM ; Hae Woong JEONG ; Sang Hyun SUH ; Yoo Dong WON ; Young-Jun LEE ; Dong Joon KIM ; Pyong JEON ; Chang-Woo RYU ; Sang-il SUH ; Dae Seob CHOI ; See Sung CHOI ; Sang Heum KIM ; Jun Soo BYUN ; Jieun RHO ; Yunsun SONG ; Woo Sang JEONG ; Noah HONG ; Sung Hyun BAIK ; Jeong Jin PARK ; Soo Mee LIM ; Jung-Jae KIM ; Woong YOON
Neurointervention 2021;16(3):240-251
Purpose:
To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL).
Materials and Methods:
Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution.
Results:
Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group.
Conclusion
Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs.
6.Retrospective anesthetic evaluation of non-obstetric surgery during pregnancy: single center experience.
Jun Rho YOON ; Eun Yong CHUNG ; Yee Suk KIM ; Young Hye KIM ; Jung Soo YEON ; Tae Kwan KIM
Anesthesia and Pain Medicine 2018;13(2):165-172
BACKGROUND: Laparoscopic procedures and ultrasonography are now commonly used in the obstetric field, and more non-obstetric procedures are being performed. However, little domestic data has been published on the topic. This present retrospective study investigated the clinical information and the effect on perinatal outcomes of non-obstetric surgery during pregnancy. METHODS: This retrospective study was performed using data of all adult pregnant women that underwent non-obstetric surgery at our institute between from July 2009 to December 2016. Data was collected from the institutional computerized database. The causes, types, and the gestational ages at surgery were collected as our primary outcomes. Basic characteristics of patients, operation times, anesthesia times, anesthetic methods, anesthetic agents, and adverse perinatal outcomes such as abortion or preterm delivery were evaluated as secondary outcomes. RESULTS: During the study period, there were 2,421 deliveries and 60 cases of non-obstetric surgery, an operation rate of 2.48%. The most common cause of non-obstetric surgery was abdominal surgery, followed by orthopedic surgery and neurosurgery. Most of abdominal surgeries were performed laparoscopically during the first trimester. The incidence of adverse perinatal outcomes was increased in the first trimester, was not related with anesthesia. CONCLUSIONS: The rate of non-obstetric surgery was found to be 2.48%, which was higher than those reported in previous domestic studies. This increase seems to have resulted from early diagnosis by ultrasonography and non-invasive surgery using laparoscopy. Adverse perinatal outcomes are not related with age, surgery and anesthetic-related factors but seem to be associated with surgery exposure stage, especially the first trimester.
Adult
;
Anesthesia
;
Anesthesia, Obstetrical
;
Anesthetics
;
Early Diagnosis
;
Female
;
Gestational Age
;
Humans
;
Incidence
;
Laparoscopy
;
Neurosurgery
;
Orthopedics
;
Patient Outcome Assessment
;
Pregnancy Trimester, First
;
Pregnancy*
;
Pregnant Women
;
Retrospective Studies*
;
Ultrasonography
7.The Characteristics and Safety of Previous Fillers in Secondary Rhinoplasty.
Bong Il RHO ; Seok Min YOON ; Eun Soo PARK ; Syeo Young WEE
Archives of Aesthetic Plastic Surgery 2018;24(2):49-54
BACKGROUND: Filler injection into the soft tissue of the nose is a useful technique for rhinoplasty. The individual characteristics of fillers determine which is best suited for a patient's specific circumstances. The objective of this study was to identify the characteristics of various fillers and to determine which fillers should be used for primary rhinoplasty in order to yield optimal long-term results. METHODS: Excluding patients treated with hyaluronic acid fillers, we reviewed 17 patients who underwent surgical rhinoplasty due to dissatisfaction with an injection using a different filler. After removing the previously injected filler, rhinoplasty was performed as part of the same procedure using a silicone or Surgiform® prosthesis. RESULTS: Various previous fillers were used in the cohort. During the process of filler removal, skin perforation occurred in 2 cases and infection was observed in 1 case. In the other cases, rhinoplasty using a prosthesis was performed at the time of filler removal and no complications were observed. CONCLUSIONS: We found that if surrounding tissue had been maintained stably, a simultaneous secondary operation using implants produced ideal results in most cases without any complications, despite the presence of residual remnant filler material.
Cohort Studies
;
Humans
;
Hyaluronic Acid
;
Nose
;
Prostheses and Implants
;
Rhinoplasty*
;
Silicon
;
Silicones
;
Skin
8.Value of the Post-Operative CT in Predicting Delayed Flap Failures Following Head and Neck Cancer Surgery.
Bitna KIM ; Dae Young YOON ; Young Lan SEO ; Min Woo PARK ; Kee Hwan KWON ; Young Soo RHO ; Chul Hoon CHUNG
Korean Journal of Radiology 2017;18(3):536-542
OBJECTIVE: To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. MATERIALS AND METHODS: We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. RESULTS: CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p < 0.05), intra- or peri-flap air collection > 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. CONCLUSION: A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery.
Fistula
;
Head and Neck Neoplasms*
;
Head*
;
Humans
;
Reconstructive Surgical Procedures
;
Retrospective Studies
;
Skin
;
Surgical Flaps
;
Tomography, X-Ray Computed
9.Report on the Project for Establishment of the Standardized Korean Laboratory Terminology Database, 2015.
Bo Kyeung JUNG ; Jeeyong KIM ; Chi Hyun CHO ; Ju Yeon KIM ; Myung Hyun NAM ; Bong Kyung SHIN ; Eun Youn RHO ; Sollip KIM ; Heungsup SUNG ; Shinyoung KIM ; Chang Seok KI ; Min Jung PARK ; Kap No LEE ; Soo Young YOON
Journal of Korean Medical Science 2017;32(4):695-699
The National Health Information Standards Committee was established in 2004 in Korea. The practical subcommittee for laboratory test terminology was placed in charge of standardizing laboratory medicine terminology in Korean. We aimed to establish a standardized Korean laboratory terminology database, Korea-Logical Observation Identifier Names and Codes (K-LOINC) based on former products sponsored by this committee. The primary product was revised based on the opinions of specialists. Next, we mapped the electronic data interchange (EDI) codes that were revised in 2014, to the corresponding K-LOINC. We established a database of synonyms, including the laboratory codes of three reference laboratories and four tertiary hospitals in Korea. Furthermore, we supplemented the clinical microbiology section of K-LOINC using an alternative mapping strategy. We investigated other systems that utilize laboratory codes in order to investigate the compatibility of K-LOINC with statistical standards for a number of tests. A total of 48,990 laboratory codes were adopted (21,539 new and 16,330 revised). All of the LOINC synonyms were translated into Korean, and 39,347 Korean synonyms were added. Moreover, 21,773 synonyms were added from reference laboratories and tertiary hospitals. Alternative strategies were established for mapping within the microbiology domain. When we applied these to a smaller hospital, the mapping rate was successfully increased. Finally, we confirmed K-LOINC compatibility with other statistical standards, including a newly proposed EDI code system. This project successfully established an up-to-date standardized Korean laboratory terminology database, as well as an updated EDI mapping to facilitate the introduction of standard terminology into institutions.
10.Risk Factors of and Treatments for Pharyngocutaneous Fistula Occurring after Oropharynx and Hypopharynx Reconstruction.
Su Bin DO ; Chul Hoon CHUNG ; Yong Joon CHANG ; Byeong Jun KIM ; Young Soo RHO
Archives of Plastic Surgery 2017;44(6):530-538
BACKGROUND: A pharyngocutaneous fistula is a common and difficult-to-manage complication after head and neck reconstruction. It can lead to serious complications such as flap failure, carotid artery rupture, and pharyngeal stricture, and may require additional surgery. Previous radiotherapy, a low serum albumin level, and a higher T stage have been proposed as contributing factors. We aimed to clarify the risk factors for pharyngocutaneous fistula in patients who underwent flap reconstruction and to describe our experiences in treating pharyngocutaneous fistula. METHODS: Squamous cell carcinoma cases that underwent flap reconstruction after cancer resection from 1995 to 2013 were analyzed retrospectively. We investigated several significant clinical risk factors. The treatment modality was selected according to the size of the fistula and the state of the surrounding tissue, with options including conservative management, direct closure, flap surgery, and pharyngostoma formation. RESULTS: A total of 127 cases (18 with fistulae) were analyzed. A higher T stage (P=0.048) and tube-type reconstruction (P=0.007) increased fistula incidence; other factors did not show statistical significance (P>0.05). Two cases were treated with conservative management, 1 case with direct closure, 4 cases with immediate reconstruction using a pectoralis major musculocutaneous flap, and 11 cases with direct closure (4 cases) or additional flap surgery (7 cases) after pharyngostoma formation. CONCLUSIONS: Pharyngocutaneous fistula requires global management from prevention to treatment. In cases of advanced-stage cancer and tube-type reconstruction, a more cautious approach should be employed. Once it occurs, an accurate diagnosis of the fistula and a thorough assessment of the surrounding tissue are necessary, and aggressive treatment should be implemented in order to ensure satisfactory long-term results.
Carcinoma, Squamous Cell
;
Carotid Arteries
;
Constriction, Pathologic
;
Cutaneous Fistula
;
Diagnosis
;
Fistula*
;
Free Tissue Flaps
;
Head
;
Humans
;
Hypopharynx*
;
Incidence
;
Myocutaneous Flap
;
Neck
;
Oropharynx*
;
Postoperative Complications
;
Radiotherapy
;
Retrospective Studies
;
Risk Factors*
;
Rupture
;
Serum Albumin

Result Analysis
Print
Save
E-mail