1.Group B Streptococcus Detection Rate and Clindamycin Resistance Among Reproductive-Age Women in Korea During 2003–2022
Areum SHIN ; Doo Ri KIM ; Ji-Hee SUNG ; Jinyoung YANG ; Suk-Joo CHOI ; Cheong-Rae ROH ; Tae Yeul KIM ; Hee Jae HUH ; Nam Yong LEE ; Soo-young OH ; Yae-Jean KIM
Journal of Korean Medical Science 2025;40(15):e29-
		                        		
		                        			 Background:
		                        			Group B Streptococcus (GBS) is one of the leading causes of neonatal earlyonset sepsis, resulting in high mortality and significant comorbidity. Intrapartum penicillin prophylaxis is recommended for pregnant women with GBS colonization to prevent vertical transmission. For pregnant women at high risk of anaphylaxis to penicillin, clindamycin is recommended only if the susceptibility of GBS isolates has been identified. We retrospectively examined the GBS detection rate and clindamycin resistance among Korean women of reproductive age over the last 20 years. 
		                        		
		                        			Methods:
		                        			Microbiologic studies using vaginal, vaginal–rectal or vaginal–perianal swabs from female patients 15–49 years of age during 2003–2022 were reviewed. Annual GBS detection rates and clindamycin resistance rates were calculated. The study period was divided into two periods (period 1, 2003–2015; period 2, 2016–2022) based on the introduction of universal culture-based GBS screening in our center in 2016. GBS detection rates and clindamycin resistance rates were compared between the periods using χ2 tests. 
		                        		
		                        			Results:
		                        			A total of 14,571 women were tested 16,879 times and GBS was isolated in 1,054 tests (6.2%), with 423 clindamycin-resistant isolates (40.1%). The GBS detection rate increased from 3.4% (301/8,869) in period 1 to 9.4% (2,753/8,010) in period 2 (P < 0.001). Even during period 1, the GBS detection rate was higher in 2009–2015 compared to 2003–2008 (P < 0.001). Clindamycin resistance rates have remained at similar levels since 2009, which were 39.5% (199/301) in period 1 and 40.2% (303/753) in period 2 (P = 0.833). 
		                        		
		                        			Conclusion
		                        			This study demonstrated that GBS detection rates in Korean women of reproductive age significantly increased almost three times during the twenty years of the study period, with a persistently high clindamycin resistance rate of up to 40%. 
		                        		
		                        		
		                        		
		                        	
2.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
		                        		
		                        			 Objective:
		                        			To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck. 
		                        		
		                        			Materials and Methods:
		                        			Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale. 
		                        		
		                        			Results:
		                        			FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE. 
		                        		
		                        			Conclusion
		                        			DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance. 
		                        		
		                        		
		                        		
		                        	
3.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
		                        		
		                        		
		                        		
		                        	
4.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
		                        		
		                        			 Objective:
		                        			To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck. 
		                        		
		                        			Materials and Methods:
		                        			Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale. 
		                        		
		                        			Results:
		                        			FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE. 
		                        		
		                        			Conclusion
		                        			DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance. 
		                        		
		                        		
		                        		
		                        	
5.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
		                        		
		                        			 Objective:
		                        			To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck. 
		                        		
		                        			Materials and Methods:
		                        			Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale. 
		                        		
		                        			Results:
		                        			FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE. 
		                        		
		                        			Conclusion
		                        			DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance. 
		                        		
		                        		
		                        		
		                        	
6.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
		                        		
		                        		
		                        		
		                        	
7.Group B Streptococcus Detection Rate and Clindamycin Resistance Among Reproductive-Age Women in Korea During 2003–2022
Areum SHIN ; Doo Ri KIM ; Ji-Hee SUNG ; Jinyoung YANG ; Suk-Joo CHOI ; Cheong-Rae ROH ; Tae Yeul KIM ; Hee Jae HUH ; Nam Yong LEE ; Soo-young OH ; Yae-Jean KIM
Journal of Korean Medical Science 2025;40(15):e29-
		                        		
		                        			 Background:
		                        			Group B Streptococcus (GBS) is one of the leading causes of neonatal earlyonset sepsis, resulting in high mortality and significant comorbidity. Intrapartum penicillin prophylaxis is recommended for pregnant women with GBS colonization to prevent vertical transmission. For pregnant women at high risk of anaphylaxis to penicillin, clindamycin is recommended only if the susceptibility of GBS isolates has been identified. We retrospectively examined the GBS detection rate and clindamycin resistance among Korean women of reproductive age over the last 20 years. 
		                        		
		                        			Methods:
		                        			Microbiologic studies using vaginal, vaginal–rectal or vaginal–perianal swabs from female patients 15–49 years of age during 2003–2022 were reviewed. Annual GBS detection rates and clindamycin resistance rates were calculated. The study period was divided into two periods (period 1, 2003–2015; period 2, 2016–2022) based on the introduction of universal culture-based GBS screening in our center in 2016. GBS detection rates and clindamycin resistance rates were compared between the periods using χ2 tests. 
		                        		
		                        			Results:
		                        			A total of 14,571 women were tested 16,879 times and GBS was isolated in 1,054 tests (6.2%), with 423 clindamycin-resistant isolates (40.1%). The GBS detection rate increased from 3.4% (301/8,869) in period 1 to 9.4% (2,753/8,010) in period 2 (P < 0.001). Even during period 1, the GBS detection rate was higher in 2009–2015 compared to 2003–2008 (P < 0.001). Clindamycin resistance rates have remained at similar levels since 2009, which were 39.5% (199/301) in period 1 and 40.2% (303/753) in period 2 (P = 0.833). 
		                        		
		                        			Conclusion
		                        			This study demonstrated that GBS detection rates in Korean women of reproductive age significantly increased almost three times during the twenty years of the study period, with a persistently high clindamycin resistance rate of up to 40%. 
		                        		
		                        		
		                        		
		                        	
8.Group B Streptococcus Detection Rate and Clindamycin Resistance Among Reproductive-Age Women in Korea During 2003–2022
Areum SHIN ; Doo Ri KIM ; Ji-Hee SUNG ; Jinyoung YANG ; Suk-Joo CHOI ; Cheong-Rae ROH ; Tae Yeul KIM ; Hee Jae HUH ; Nam Yong LEE ; Soo-young OH ; Yae-Jean KIM
Journal of Korean Medical Science 2025;40(15):e29-
		                        		
		                        			 Background:
		                        			Group B Streptococcus (GBS) is one of the leading causes of neonatal earlyonset sepsis, resulting in high mortality and significant comorbidity. Intrapartum penicillin prophylaxis is recommended for pregnant women with GBS colonization to prevent vertical transmission. For pregnant women at high risk of anaphylaxis to penicillin, clindamycin is recommended only if the susceptibility of GBS isolates has been identified. We retrospectively examined the GBS detection rate and clindamycin resistance among Korean women of reproductive age over the last 20 years. 
		                        		
		                        			Methods:
		                        			Microbiologic studies using vaginal, vaginal–rectal or vaginal–perianal swabs from female patients 15–49 years of age during 2003–2022 were reviewed. Annual GBS detection rates and clindamycin resistance rates were calculated. The study period was divided into two periods (period 1, 2003–2015; period 2, 2016–2022) based on the introduction of universal culture-based GBS screening in our center in 2016. GBS detection rates and clindamycin resistance rates were compared between the periods using χ2 tests. 
		                        		
		                        			Results:
		                        			A total of 14,571 women were tested 16,879 times and GBS was isolated in 1,054 tests (6.2%), with 423 clindamycin-resistant isolates (40.1%). The GBS detection rate increased from 3.4% (301/8,869) in period 1 to 9.4% (2,753/8,010) in period 2 (P < 0.001). Even during period 1, the GBS detection rate was higher in 2009–2015 compared to 2003–2008 (P < 0.001). Clindamycin resistance rates have remained at similar levels since 2009, which were 39.5% (199/301) in period 1 and 40.2% (303/753) in period 2 (P = 0.833). 
		                        		
		                        			Conclusion
		                        			This study demonstrated that GBS detection rates in Korean women of reproductive age significantly increased almost three times during the twenty years of the study period, with a persistently high clindamycin resistance rate of up to 40%. 
		                        		
		                        		
		                        		
		                        	
9.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
		                        		
		                        		
		                        		
		                        	
10.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
		                        		
		                        			 Objective:
		                        			To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck. 
		                        		
		                        			Materials and Methods:
		                        			Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale. 
		                        		
		                        			Results:
		                        			FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE. 
		                        		
		                        			Conclusion
		                        			DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail