Purpose:
The purpose of this study was to develop an approach to alleviate the discomfort caused by sandbag compression after a bone marrow examination. This research examined the effects of applying a pressure hemostasis band on bleeding, pain, and discomfort at the bone marrow examination site.
Methods:
This study was conducted with a nonequivalent control group non-synchronized design. For 74 patients under evaluation who underwent bone marrow examination, sandbag compression was applied to the examination site in the control group (n=37), and a pressure hemostasis band was applied to the intervention group (n=37). In both groups, absolute bed rest was performed for two hours, and bleeding, pain, and discomfort at the examination site were measured.
Results:
After two hours of the bone marrow examination, there was no difference in bleeding on the gauze between the two groups (F=0.59, p=.444). Bleeding occurred in three patients in the intervention group and six in the control group (χ 2 =1.14, p=.479), with no cases of hematoma detected in either group. One hour post-examination, the control group experienced significantly higher pain (F=5.45, p=.022) and discomfort (F=5.68, p=.020) than the intervention group. However, pain and discomfort levels were similar between groups after two hours.
Conclusion
Compared to the sandbag compression group, the band application group showed no difference in bleeding and experienced less pain and discomfort at the examination site. This confirms that the pressure hemostasis band is a suitable alternative to sandbag compression in post-examination care.
2.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
3.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
4.Effects of Pressure Hemostasis Band Application on Bleeding, Pain, and Discomfort after Bone Marrow Examination
Jin Hee JUNG ; Bo-Eun KIM ; Ji Sook JU ; Mi RYU ; So Young CHOE ; Jong Hee CHOI ; Soo-Mee BANG ; Jeong-Ok LEE ; Ji Yun LEE ; Sang-A KIM
Asian Oncology Nursing 2025;25(1):17-27
Purpose:
The purpose of this study was to develop an approach to alleviate the discomfort caused by sandbag compression after a bone marrow examination. This research examined the effects of applying a pressure hemostasis band on bleeding, pain, and discomfort at the bone marrow examination site.
Methods:
This study was conducted with a nonequivalent control group non-synchronized design. For 74 patients under evaluation who underwent bone marrow examination, sandbag compression was applied to the examination site in the control group (n=37), and a pressure hemostasis band was applied to the intervention group (n=37). In both groups, absolute bed rest was performed for two hours, and bleeding, pain, and discomfort at the examination site were measured.
Results:
After two hours of the bone marrow examination, there was no difference in bleeding on the gauze between the two groups (F=0.59, p=.444). Bleeding occurred in three patients in the intervention group and six in the control group (χ 2 =1.14, p=.479), with no cases of hematoma detected in either group. One hour post-examination, the control group experienced significantly higher pain (F=5.45, p=.022) and discomfort (F=5.68, p=.020) than the intervention group. However, pain and discomfort levels were similar between groups after two hours.
Conclusion
Compared to the sandbag compression group, the band application group showed no difference in bleeding and experienced less pain and discomfort at the examination site. This confirms that the pressure hemostasis band is a suitable alternative to sandbag compression in post-examination care.
5.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
6.Effects of Pressure Hemostasis Band Application on Bleeding, Pain, and Discomfort after Bone Marrow Examination
Jin Hee JUNG ; Bo-Eun KIM ; Ji Sook JU ; Mi RYU ; So Young CHOE ; Jong Hee CHOI ; Soo-Mee BANG ; Jeong-Ok LEE ; Ji Yun LEE ; Sang-A KIM
Asian Oncology Nursing 2025;25(1):17-27
Purpose:
The purpose of this study was to develop an approach to alleviate the discomfort caused by sandbag compression after a bone marrow examination. This research examined the effects of applying a pressure hemostasis band on bleeding, pain, and discomfort at the bone marrow examination site.
Methods:
This study was conducted with a nonequivalent control group non-synchronized design. For 74 patients under evaluation who underwent bone marrow examination, sandbag compression was applied to the examination site in the control group (n=37), and a pressure hemostasis band was applied to the intervention group (n=37). In both groups, absolute bed rest was performed for two hours, and bleeding, pain, and discomfort at the examination site were measured.
Results:
After two hours of the bone marrow examination, there was no difference in bleeding on the gauze between the two groups (F=0.59, p=.444). Bleeding occurred in three patients in the intervention group and six in the control group (χ 2 =1.14, p=.479), with no cases of hematoma detected in either group. One hour post-examination, the control group experienced significantly higher pain (F=5.45, p=.022) and discomfort (F=5.68, p=.020) than the intervention group. However, pain and discomfort levels were similar between groups after two hours.
Conclusion
Compared to the sandbag compression group, the band application group showed no difference in bleeding and experienced less pain and discomfort at the examination site. This confirms that the pressure hemostasis band is a suitable alternative to sandbag compression in post-examination care.
7.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
8.Combi-Elastography versus Transient Elastography for Assessing the Histological Severity of Metabolic Dysfunction-Associated Steatotic Liver Disease
Yun Kyu LEE ; Dong Hyeon LEE ; Sae Kyung JOO ; Heejoon JANG ; Young Ho SO ; Siwon JANG ; Dong Ho LEE ; Jeong Hwan PARK ; Mee Soo CHANG ; Won KIM ;
Gut and Liver 2024;18(6):1048-1059
Background/Aims:
Combi-elastography is a B-mode ultrasound-based method in which two elastography modalities are utilized simultaneously to assess metabolic dysfunction-associated steatotic liver disease (MASLD). However, the performance of combi-elastography for diagnosing metabolic dysfunction-associated steatohepatitis (MASH) and determining fibrosis severity is unclear. This study compared the diagnostic performances of combi-elastography and vibrationcontrolled transient elastography (VCTE) for identifying hepatic steatosis, fibrosis, and high-risk MASH.
Methods:
Participants who underwent combi-elastography, VCTE, and liver biopsy were selected from a prospective cohort of patients with clinically suspected MASLD. Combi-elastographyrelated parameters were acquired, and their performances were evaluated using area under the receiver-operating characteristic curve (AUROC) analysis.
Results:
A total of 212 participants were included. The diagnostic performance for hepatic steatosis of the attenuation coefficient adjusted by covariates from combi-elastography was comparable to that of the controlled attenuation parameter measured by VCTE (AUROC, 0.85 vs 0.85; p=0.925). The performance of the combi-elastography-derived fibrosis index adjusted by covariates for diagnosing significant fibrosis was comparable to that of liver stiffness measured by VCTE (AUROC, 0.77 vs 0.80; p=0.573). The activity index from combi-elastography adjusted by covariates was equivalent to the FibroScan-aspartate aminotransferase score in diagnosing high-risk MASH among participants with MASLD (AUROC, 0.72 vs 0.74; p=0.792).
Conclusions
The performance of combi-elastography is similar to that of VCTE when evaluating histology of MASLD.
9.Combi-Elastography versus Transient Elastography for Assessing the Histological Severity of Metabolic Dysfunction-Associated Steatotic Liver Disease
Yun Kyu LEE ; Dong Hyeon LEE ; Sae Kyung JOO ; Heejoon JANG ; Young Ho SO ; Siwon JANG ; Dong Ho LEE ; Jeong Hwan PARK ; Mee Soo CHANG ; Won KIM ;
Gut and Liver 2024;18(6):1048-1059
Background/Aims:
Combi-elastography is a B-mode ultrasound-based method in which two elastography modalities are utilized simultaneously to assess metabolic dysfunction-associated steatotic liver disease (MASLD). However, the performance of combi-elastography for diagnosing metabolic dysfunction-associated steatohepatitis (MASH) and determining fibrosis severity is unclear. This study compared the diagnostic performances of combi-elastography and vibrationcontrolled transient elastography (VCTE) for identifying hepatic steatosis, fibrosis, and high-risk MASH.
Methods:
Participants who underwent combi-elastography, VCTE, and liver biopsy were selected from a prospective cohort of patients with clinically suspected MASLD. Combi-elastographyrelated parameters were acquired, and their performances were evaluated using area under the receiver-operating characteristic curve (AUROC) analysis.
Results:
A total of 212 participants were included. The diagnostic performance for hepatic steatosis of the attenuation coefficient adjusted by covariates from combi-elastography was comparable to that of the controlled attenuation parameter measured by VCTE (AUROC, 0.85 vs 0.85; p=0.925). The performance of the combi-elastography-derived fibrosis index adjusted by covariates for diagnosing significant fibrosis was comparable to that of liver stiffness measured by VCTE (AUROC, 0.77 vs 0.80; p=0.573). The activity index from combi-elastography adjusted by covariates was equivalent to the FibroScan-aspartate aminotransferase score in diagnosing high-risk MASH among participants with MASLD (AUROC, 0.72 vs 0.74; p=0.792).
Conclusions
The performance of combi-elastography is similar to that of VCTE when evaluating histology of MASLD.
10.Combi-Elastography versus Transient Elastography for Assessing the Histological Severity of Metabolic Dysfunction-Associated Steatotic Liver Disease
Yun Kyu LEE ; Dong Hyeon LEE ; Sae Kyung JOO ; Heejoon JANG ; Young Ho SO ; Siwon JANG ; Dong Ho LEE ; Jeong Hwan PARK ; Mee Soo CHANG ; Won KIM ;
Gut and Liver 2024;18(6):1048-1059
Background/Aims:
Combi-elastography is a B-mode ultrasound-based method in which two elastography modalities are utilized simultaneously to assess metabolic dysfunction-associated steatotic liver disease (MASLD). However, the performance of combi-elastography for diagnosing metabolic dysfunction-associated steatohepatitis (MASH) and determining fibrosis severity is unclear. This study compared the diagnostic performances of combi-elastography and vibrationcontrolled transient elastography (VCTE) for identifying hepatic steatosis, fibrosis, and high-risk MASH.
Methods:
Participants who underwent combi-elastography, VCTE, and liver biopsy were selected from a prospective cohort of patients with clinically suspected MASLD. Combi-elastographyrelated parameters were acquired, and their performances were evaluated using area under the receiver-operating characteristic curve (AUROC) analysis.
Results:
A total of 212 participants were included. The diagnostic performance for hepatic steatosis of the attenuation coefficient adjusted by covariates from combi-elastography was comparable to that of the controlled attenuation parameter measured by VCTE (AUROC, 0.85 vs 0.85; p=0.925). The performance of the combi-elastography-derived fibrosis index adjusted by covariates for diagnosing significant fibrosis was comparable to that of liver stiffness measured by VCTE (AUROC, 0.77 vs 0.80; p=0.573). The activity index from combi-elastography adjusted by covariates was equivalent to the FibroScan-aspartate aminotransferase score in diagnosing high-risk MASH among participants with MASLD (AUROC, 0.72 vs 0.74; p=0.792).
Conclusions
The performance of combi-elastography is similar to that of VCTE when evaluating histology of MASLD.