1.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
2.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
4.A practical guide for enteral nutrition from the Korean Society for Parenteral and Enteral Nutrition: Part I. prescribing enteral nutrition orders
Ye Rim CHANG ; Bo-Eun KIM ; In Seok LEE ; Youn Soo CHO ; Sung-Sik HAN ; Eunjung KIM ; Hyunjung KIM ; Jae Hak KIM ; Jeong Wook KIM ; Sung Shin KIM ; Eunhee KONG ; Ja Kyung MIN ; Chi-Min PARK ; Jeongyun PARK ; Seungwan RYU ; Kyung Won SEO ; Jung Mi SONG ; Minji SEOK ; Eun-Mi SEOL ; Jinhee YOON ; Jeong Meen SEO ;
Annals of Clinical Nutrition and Metabolism 2025;17(1):3-8
Purpose:
This study aimed to develop a comprehensive practical guide for enteral nutrition (EN) designed to enhance patient safety and reduce complications in Korea. Under the leadership of the Korean Society for Parenteral and Enteral Nutrition (KSPEN), the initiative sought to standardize EN procedures, improve decision-making, and promote effective multidisciplinary communication.
Methods:
The KSPEN EN committee identified key questions related to EN practices and organized them into seven sections such as prescribing, delivery route selection, formula preparation, administration, and quality management. Twenty-one experts, selected based on their expertise, conducted a thorough literature review to formulate evidence-based recommendations. Drafts underwent peer review both within and across disciplines, with final revisions completed by the KSPEN Guideline Committee. The guide, which will be published in three installments, addresses critical elements of EN therapy and safety protocols.
Results:
The practical guide recommends that EN orders include detailed elements and advocates the use of electronic medical records for communication. Standardized prescription forms and supplementary safety measures are outlined. Review frequency is adjusted according to patient condition—daily for critically ill or unstable patients and as dictated by institutional protocols for stable patients. Evidence indicates that adherence to these protocols reduces mortality, complications, and prescription errors.
Conclusion
The KSPEN practical guide offers a robust framework for the safe delivery of EN tailored to Korea’s healthcare context. It emphasizes standardized protocols and interdisciplinary collaboration to improve nutritional outcomes, patient safety, and operational efficiency. Rigorous implementation and monitoring of adherence are critical for its success.
5.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
6.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
7.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
8.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
9.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail