1.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
		                        		
		                        			 Objective:
		                        			To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation. 
		                        		
		                        			Methods:
		                        			In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.  
		                        		
		                        			Results:
		                        			The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.  
		                        		
		                        			Conclusions
		                        			Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces. 
		                        		
		                        		
		                        		
		                        	
2.Long-Term Efficacy and Safety of Denosumab: Insights beyond 10 Years of Use
Jeonghoon HA ; Youn-Ju LEE ; Jinyoung KIM ; Chaiho JEONG ; Yejee LIM ; Jeongmin LEE ; Ki-Hyun BAEK ;
Endocrinology and Metabolism 2025;40(1):47-56
		                        		
		                        			
		                        			 Osteoporosis management in post-menopausal women focuses on fracture prevention, with denosumab as a key therapeutic option. Despite its proven efficacy in reducing fracture risk and increasing bone mineral density (BMD) over 10 years, its long-term impact remains uncertain. We evaluated the literature on its efficacy and safety beyond the initial decade. Clinical trials and real-world studies confirm denosumab’s sustained efficacy, especially in lumbar spine BMD, with hip BMD stabilizing. Concerns about adverse events (AEs) like hypocalcemia and osteonecrosis of the jaw necessitate vigilant monitoring. Risks of atypical femoral fractures and malignancies also require attention, despite unclear links to treatment duration. Clinical guidelines for denosumab beyond 10 years are limited, emphasizing the need for careful monitoring. In certain scenarios, such as advanced chronic kidney disease, prolonged denosumab may be required to balance AE risks with fracture prevention benefits. Denosumab shows potential for long-term efficacy in augmenting BMD; however, monitoring for AEs is crucial to guide clinical decision-making effectively. 
		                        		
		                        		
		                        		
		                        	
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
		                        		
		                        			 Objective:
		                        			To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation. 
		                        		
		                        			Methods:
		                        			In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.  
		                        		
		                        			Results:
		                        			The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.  
		                        		
		                        			Conclusions
		                        			Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces. 
		                        		
		                        		
		                        		
		                        	
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
		                        		
		                        			 Objective:
		                        			To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation. 
		                        		
		                        			Methods:
		                        			In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.  
		                        		
		                        			Results:
		                        			The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.  
		                        		
		                        			Conclusions
		                        			Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces. 
		                        		
		                        		
		                        		
		                        	
5.Long-Term Efficacy and Safety of Denosumab: Insights beyond 10 Years of Use
Jeonghoon HA ; Youn-Ju LEE ; Jinyoung KIM ; Chaiho JEONG ; Yejee LIM ; Jeongmin LEE ; Ki-Hyun BAEK ;
Endocrinology and Metabolism 2025;40(1):47-56
		                        		
		                        			
		                        			 Osteoporosis management in post-menopausal women focuses on fracture prevention, with denosumab as a key therapeutic option. Despite its proven efficacy in reducing fracture risk and increasing bone mineral density (BMD) over 10 years, its long-term impact remains uncertain. We evaluated the literature on its efficacy and safety beyond the initial decade. Clinical trials and real-world studies confirm denosumab’s sustained efficacy, especially in lumbar spine BMD, with hip BMD stabilizing. Concerns about adverse events (AEs) like hypocalcemia and osteonecrosis of the jaw necessitate vigilant monitoring. Risks of atypical femoral fractures and malignancies also require attention, despite unclear links to treatment duration. Clinical guidelines for denosumab beyond 10 years are limited, emphasizing the need for careful monitoring. In certain scenarios, such as advanced chronic kidney disease, prolonged denosumab may be required to balance AE risks with fracture prevention benefits. Denosumab shows potential for long-term efficacy in augmenting BMD; however, monitoring for AEs is crucial to guide clinical decision-making effectively. 
		                        		
		                        		
		                        		
		                        	
6.Long-Term Efficacy and Safety of Denosumab: Insights beyond 10 Years of Use
Jeonghoon HA ; Youn-Ju LEE ; Jinyoung KIM ; Chaiho JEONG ; Yejee LIM ; Jeongmin LEE ; Ki-Hyun BAEK ;
Endocrinology and Metabolism 2025;40(1):47-56
		                        		
		                        			
		                        			 Osteoporosis management in post-menopausal women focuses on fracture prevention, with denosumab as a key therapeutic option. Despite its proven efficacy in reducing fracture risk and increasing bone mineral density (BMD) over 10 years, its long-term impact remains uncertain. We evaluated the literature on its efficacy and safety beyond the initial decade. Clinical trials and real-world studies confirm denosumab’s sustained efficacy, especially in lumbar spine BMD, with hip BMD stabilizing. Concerns about adverse events (AEs) like hypocalcemia and osteonecrosis of the jaw necessitate vigilant monitoring. Risks of atypical femoral fractures and malignancies also require attention, despite unclear links to treatment duration. Clinical guidelines for denosumab beyond 10 years are limited, emphasizing the need for careful monitoring. In certain scenarios, such as advanced chronic kidney disease, prolonged denosumab may be required to balance AE risks with fracture prevention benefits. Denosumab shows potential for long-term efficacy in augmenting BMD; however, monitoring for AEs is crucial to guide clinical decision-making effectively. 
		                        		
		                        		
		                        		
		                        	
7.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
		                        		
		                        			 Objective:
		                        			To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation. 
		                        		
		                        			Methods:
		                        			In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.  
		                        		
		                        			Results:
		                        			The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.  
		                        		
		                        			Conclusions
		                        			Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces. 
		                        		
		                        		
		                        		
		                        	
8.Long-Term Efficacy and Safety of Denosumab: Insights beyond 10 Years of Use
Jeonghoon HA ; Youn-Ju LEE ; Jinyoung KIM ; Chaiho JEONG ; Yejee LIM ; Jeongmin LEE ; Ki-Hyun BAEK ;
Endocrinology and Metabolism 2025;40(1):47-56
		                        		
		                        			
		                        			 Osteoporosis management in post-menopausal women focuses on fracture prevention, with denosumab as a key therapeutic option. Despite its proven efficacy in reducing fracture risk and increasing bone mineral density (BMD) over 10 years, its long-term impact remains uncertain. We evaluated the literature on its efficacy and safety beyond the initial decade. Clinical trials and real-world studies confirm denosumab’s sustained efficacy, especially in lumbar spine BMD, with hip BMD stabilizing. Concerns about adverse events (AEs) like hypocalcemia and osteonecrosis of the jaw necessitate vigilant monitoring. Risks of atypical femoral fractures and malignancies also require attention, despite unclear links to treatment duration. Clinical guidelines for denosumab beyond 10 years are limited, emphasizing the need for careful monitoring. In certain scenarios, such as advanced chronic kidney disease, prolonged denosumab may be required to balance AE risks with fracture prevention benefits. Denosumab shows potential for long-term efficacy in augmenting BMD; however, monitoring for AEs is crucial to guide clinical decision-making effectively. 
		                        		
		                        		
		                        		
		                        	
9.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
		                        		
		                        			 Objective:
		                        			To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation. 
		                        		
		                        			Methods:
		                        			In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.  
		                        		
		                        			Results:
		                        			The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.  
		                        		
		                        			Conclusions
		                        			Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces. 
		                        		
		                        		
		                        		
		                        	
10.Comparative Analysis of Pathogen Detection and Eradication in Single vs. Revision Amputation Cases of Diabetic Foot Patients
Ki Youn KWON ; Hee Heon JEONG ; Jung Woo LEE
Journal of Korean Foot and Ankle Society 2024;28(4):157-164
		                        		
		                        			 Purpose:
		                        			This study examined the differences in pathogen survival between single and revision amputations in diabetic foot infections.Current research lacks data on the postoperative pathogen profiles, particularly in cases involving repeated surgeries, making this study essential for targeted infection management. 
		                        		
		                        			Materials and Methods:
		                        			The medical records of 168 diabetic foot ulcer patients treated at a single center, divided into single (n=113) and revision amputation groups (n=55) were analyzed retrospectively. Preoperative deep tissue samples and postoperative wound swab samples were collected to analyze the pathogens. The C-reactive protein (CRP) levels were measured as an inflammation marker. The pathogen diversity, frequency, and survival rate were compared. The ‘survival rate’ was defined as the frequency of postoperative persistence of pathogens relative to the preoperative detection frequency. 
		                        		
		                        			Results:
		                        			Revision amputation cases showed a higher diversity (p=0.0029) and persistence of pathogens, with methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa, and most other detected pathogens displaying higher survival rates. The CRP levels generally decreased postoperatively, but the variability was more pronounced in the revision group, suggesting that CRP may not consistently correlate with infection control in complex cases. 
		                        		
		                        			Conclusion
		                        			These findings revealed significant differences in the pathogen profiles between single and revision amputations, with revision cases facing more significant infection challenges because of the higher resistant pathogen persistence. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail