1.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
Objective:
This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).
Methods:
The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.
Results:
The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.
Conclusions
Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
2.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
Objective:
This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).
Methods:
The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.
Results:
The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.
Conclusions
Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
3.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
Objective:
This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).
Methods:
The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.
Results:
The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.
Conclusions
Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
4.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
Objective:
This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).
Methods:
The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.
Results:
The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.
Conclusions
Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
5.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
Objective:
This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).
Methods:
The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.
Results:
The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.
Conclusions
Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
6.The Effect of Tegoprazan on the Treatment of Endoscopic Resection-Induced Artificial Ulcers: A Multicenter, Randomized, Active-Controlled Study
Byung-Wook KIM ; Jong Jae PARK ; Hee Seok MOON ; Wan Sik LEE ; Ki-Nam SHIM ; Gwang Ho BAIK ; Yun Jeong LIM ; Hang Lak LEE ; Young Hoon YOUN ; Jun Chul PARK ; In-Kyung SUNG ; Hyunsoo CHUNG ; Jeong Seop MOON ; Gwang Ha KIM ; Su Jin HONG ; Hyuk Soon CHOI
Gut and Liver 2024;18(2):257-264
Background/Aims:
Tegoprazan is a novel potassium-competitive acid blocker that has beneficial effects on acid-related disorders such as gastroesophageal reflux and peptic ulcer diseases.This study aimed to validate the effect of tegoprazan on endoscopic submucosal dissection (ESD)-induced artificial ulcers.
Methods:
Patients from 16 centers in Korea who underwent ESD for gastric neoplasia were enrolled. After ESD, pantoprazole was administered intravenously for 48 hours. The patients were randomly allocated to either the tegoprazan or esomeprazole group. Tegoprazan 50 mg or esomeprazole 40 mg were administered for 4 weeks, after which gastroscopic evaluation was performed. If the artificial ulcer had not healed, the same dose of tegoprazan or esomeprazole was administered for an additional 4 weeks, and a gastroscopic evaluation was performed.
Results:
One hundred sixty patients were enrolled in this study. The healing rates of artificial ulcers at 4 weeks were 30.3% (23/76) and 22.1% (15/68) in the tegoprazan and esomeprazole groups, respectively (p=0.006). At 8 weeks after ESD, the cumulative ulcer healing rates were 73.7% (56/76) and 77.9% (53/68) in the tegoprazan and esomeprazole groups, respectively (p=0.210). Delayed bleeding occurred in two patients in the tegoprazan group (2.6%) and in one patient in the esomeprazole group (1.5%). Other adverse events were negligible in both groups.
Conclusions
Tegoprazan showed similar effects on post-ESD artificial ulcer healing in comparison with esomeprazole.
7.Validation of the Korean Version of the Questionnaire for Impulsive-Compulsive Disorders in Parkinson's Disease Rating Scale
Ji-Hyun CHOI ; Jee-Young LEE ; Jin Whan CHO ; Seong-Beom KO ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Joong-Seok KIM ; Yoon-Joong KIM ; Hyeo-Il MA ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; In-Uk SONG ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Ji-Young KIM ; Ji Sun KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung Kim KIM ; Jinyoung YOUN ; Ji Seon Kim KIM ; Eung Seok OH ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Hyung-Eun PARK ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Mee Young PARK
Journal of Clinical Neurology 2020;16(2):245-253
Background:
and PurposeImpulse-control disorder is an important nonmotor symptom of Parkinson's disease (PD) that can lead to financial and social problems, and be related to a poor quality of life. A nationwide multicenter prospective study was performed with the aim of validating the Korean Version of the Questionnaire for Impulsive-Compulsive Disorders in Parkinson's Disease Rating Scale (K-QUIP-RS).
Methods:
The K-QUIP-RS was constructed using forward and backward translation, and pretesting of the prefinal version. PD patients on stable medical condition were recruited from 27 movement-disorder clinics. Participants were assessed using the K-QUIP-RS and evaluated for parkinsonian motor and nonmotor statuses and for PD-related quality of life using a predefined evaluation battery. The test–retest reliability of the K-QUIP-RS was assessed over an interval of 10–14 days, and correlations between the KQUIP-RS and other clinical scales were analyzed.
Results:
This study enrolled 136 patients. The internal consistency of the K-QUIP-RS was indicated by a Cronbach's α coefficient of 0.846, as was the test–retest reliability by a Guttman split-half coefficient of 0.808. The total K-QUIP-RS score was positively correlated with the scores for depression and motivation items on the Unified PD Rating Scale (UPDRS), Montgomery-Asberg Depression Scale, and Rapid-Eye-Movement Sleep-Behavior-Disorders Questionnaire. The total K-QUIP-RS score was also correlated with the scores on part II of the UPDRS and the PD Quality of Life-39 questionnaire, and the dopaminergic medication dose.
Conclusions
The K-QUIP-RS appears to be a reliable assessment tool for impulse-control and related behavioral disturbances in the Korean PD population.
8.Chronic Hepatitis B Infection Is Significantly Associated with Chronic Kidney Disease: a Population-based, Matched Case-control Study.
Sung Eun KIM ; Eun Sun JANG ; Moran KI ; Geum Youn GWAK ; Kyung Ah KIM ; Gi Ae KIM ; Do Young KIM ; Dong Joon KIM ; Man Woo KIM ; Yun Soo KIM ; Young Seok KIM ; In Hee KIM ; Chang Wook KIM ; Ho Dong KIM ; Hyung Joon KIM ; Neung Hwa PARK ; Soon Koo BAIK ; Jeong Ill SUH ; Byung Cheol SONG ; Il Han SONG ; Jong Eun YEON ; Byung Seok LEE ; Youn Jae LEE ; Young Kul JUNG ; Woo Jin CHUNG ; Sung Bum CHO ; Eun Young CHO ; Hyun Chin CHO ; Gab Jin CHEON ; Hee Bok CHAE ; DaeHee CHOI ; Sung Kyu CHOI ; Hwa Young CHOI ; Won Young TAK ; Jeong HEO ; Sook Hyang JEONG
Journal of Korean Medical Science 2018;33(42):e264-
BACKGROUND: Hepatitis B virus (HBV) infection leads to hepatic and extrahepatic manifestations including chronic kidney disease (CKD). However, the association between HBV and CKD is not clear. This study investigated the association between chronic HBV infection and CKD in a nationwide multicenter study. METHODS: A total of 265,086 subjects who underwent health-check examinations in 33 hospitals from January 2015 to December 2015 were enrolled. HBV surface antigen (HBsAg) positive cases (n = 10,048), and age- and gender-matched HBsAg negative controls (n = 40,192) were identified. CKD was defined as a glomerular filtration rate (GFR) < 60 mL/min/1.73 m² or proteinuria as at least grade 2+ of urine protein. RESULTS: HBsAg positive cases showed a significantly higher prevalence of GFR < 60 mL/min/1.73 m² (3.3%), and proteinuria (18.9%) than that of the controls (2.6%, P < 0.001, and 14.1%, P < 0.001, respectively). In the multivariate analysis, HBsAg positivity was an independent factor associated with GFR < 60 mL/min/1.73 m² along with age, blood levels of albumin, bilirubin, anemia, and hemoglobin A1c (HbA1c). Likewise, HBsAg positivity was an independent factor for proteinuria along with age, male, blood levels of bilirubin, protein, albumin, and HbA1c. A subgroup analysis showed that HBsAg positive men but not women had a significantly increased risk for GFR < 60 mL/min/1.73 m². CONCLUSION: Chronic HBV infection was significantly associated with a GFR < 60 mL/min/1.73 m² and proteinuria (≥ 2+). Therefore, clinical concern about CKD in chronic HBV infected patients, especially in male, is warranted.
Anemia
;
Antigens, Surface
;
Bilirubin
;
Case-Control Studies*
;
Female
;
Glomerular Filtration Rate
;
Hepatitis B Surface Antigens
;
Hepatitis B virus
;
Hepatitis B, Chronic*
;
Hepatitis, Chronic*
;
Humans
;
Male
;
Multivariate Analysis
;
Prevalence
;
Proteinuria
;
Renal Insufficiency, Chronic*
9.Incisional and Ventral Hernia Repair.
Journal of Minimally Invasive Surgery 2018;21(1):5-13
Incisional or ventral hernia is a very common multifactorial disease that requires surgery to prevent complications, including pain, discomfort, bowel obstruction, incarceration, and strangulation. To perform herniorrhaphy, it is essential to understand the pathogenesis of hernia, the anatomy and physiology of the abdominal wall, and surgical techniques. Several repair methods are available, including open suture repair, open mesh repair, the component separation technique, and tissue expansion assisted closure. Currently, laparoscopic incisional or ventral hernia repair is commonly used with the major advantage being the lower recurrence and all defects can be addressed at the time of surgery as well as reduced postoperative pain and length of hospital stay. On the other hand, to do it properly, a full understanding and appropriate selection of mesh and management of probable complications, such as seroma, bowel injury, enteric fistula, and recurrence, is essential. Therefore, the surgeon and the techniques used are of paramount importance in the repair of incisional ventral hernias.
Abdominal Wall
;
Fistula
;
Hand
;
Hernia
;
Hernia, Ventral*
;
Herniorrhaphy
;
Incisional Hernia
;
Length of Stay
;
Pain, Postoperative
;
Physiology
;
Recurrence
;
Seroma
;
Sutures
;
Tissue Expansion
10.Consensus guidelines for the definition of the end stage of disease and last days of life and criteria for medical judgment
Sang Min LEE ; Su Jung KIM ; Youn Seon CHOI ; Dae Seog HEO ; Sujin BAIK ; Bo Moon CHOI ; Daekyun KIM ; Jae Young MOON ; So Young PARK ; Yoon Jung CHANG ; In Cheol HWANG ; Jung Hye KWON ; Sun Hyun KIM ; Yu Jung KIM ; Jeanno PARK ; Ho Jung AHN ; Hyun Woo LEE ; Ivo KWON ; Do Kyong KIM ; Ock Joo KIM ; Sang Ho YOO ; Yoo Seock CHEONG ; Younsuck KOH
Journal of the Korean Medical Association 2018;61(8):509-521
In Korea, the Hospice, Palliative Care, and Life-sustaining Treatment Decision-making Act was enacted in February 2016 in order to ensure that the patient's self-determination in end-of-life care processes is respected. To enhance physicians' understanding of this act and to provide proper criteria for medical judgment in variety of clinical settings, consensus guidelines were published in November 2016. In this article, the characteristics of these guidelines and related issues regarding the definitions of ‘the end stage of disease’ and ‘last days of life’ and the criteria for medical judgment are presented and summarized. According to the guidelines, the term ‘end stage of disease’ refers to a state in which there is no possibility of a fundamental recovery and the symptoms are expected to worsen within months. The terms ‘the last days of life’ and ‘the final days of life’ refer to a state in which, despite treatment, the patient's condition is worsening and death is impending, with no possibility of recovery. The attending physician and another relevant specialist should both judge a patient's medical condition as either ‘end stage of disease’ for hospice/palliative care or ‘the last days of life’ for dying patient care according to the law. Caregivers should provide appropriate medical information to eligible patients for palliative or ‘end stage of disease’ care through advance care planning. Therefore, it is critically necessary that caregivers understand the legitimate process of hospice/palliative and dying patient care based on the patient's wishes and best interests. Physicians should apply these consensus guidelines to eligible patients considering their clinical course and the patients' wishes.
Advance Care Planning
;
Caregivers
;
Consensus
;
Hospices
;
Humans
;
Judgment
;
Jurisprudence
;
Korea
;
Palliative Care
;
Patient Care
;
Specialization

Result Analysis
Print
Save
E-mail