1.Clinical evaluation and management of endometriosis: 2024 guideline for Korean patients from the Korean Society of Endometriosis
Hyun Joo LEE ; Sang-Hee YOON ; Jae Hoon LEE ; Youn-Jee CHUNG ; So Yun PARK ; Sung Woo KIM ; Yeon Hee HONG ; Sung Eun KIM ; Youjin KIM ; Sungwook CHUN ; Yong Jin NA
Obstetrics & Gynecology Science 2025;68(1):43-58
Endometriosis, a prevalent but debilitating condition affecting women, poses significant challenges in diagnosis and management. The current 2024 guideline, developed by the Korean Society of Endometriosis (KSE), builds upon the 2018 KSE guideline. This guideline aims to provide customized recommendations tailored to Korea’s unique clinical aspects and medical environment, and addresses key areas such as diagnosis, medical and surgical management, considerations for special populations, and its complex relationship with cancer.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Clinical Profiles of Multidrug-Resistant and Rifampicin-Monoresistant Tuberculosis in Korea, 2018–2021: A Nationwide Cross-Sectional Study
Jinsoo MIN ; Yousang KO ; Hyung Woo KIM ; Hyeon-Kyoung KOO ; Jee Youn OH ; Doosoo JEON ; Taehoon LEE ; Young-Chul KIM ; Sung Chul LIM ; Sung Soon LEE ; Jae Seuk PARK ; Ju Sang KIM
Tuberculosis and Respiratory Diseases 2025;88(1):159-169
Background:
This study aimed to identify the clinical characteristics of multidrug-resistant/ rifampicin-resistant tuberculosis (MDR/RR-TB) in the Republic of Korea.
Methods:
Data of notified people with tuberculosis between July 2018 and December 2021 were retrieved from the Korea Tuberculosis Cohort database. MDR/RR-TB was further categorized according to isoniazid susceptibility as follows: multidrug-resistant tuberculosis (MDR-TB), rifampicin-monoresistant tuberculosis (RMR-TB), and RR-TB if susceptibility to isoniazid was unknown. Multivariable logistic regression analysis was conducted to identify the factors associated with MDR/RR-TB.
Results:
Between 2018 and 2021, the proportion of MDR/RR-TB cases among all TB cases and TB cases with known drug susceptibility test results was 2.1% (502/24,447). The proportions of MDR/RR-TB and MDR-TB cases among TB cases with known drug susceptibility test results were 3.3% (502/15,071) and 1.9% (292/15,071), respectively. Among all cases of rifampicin resistance, 31.7% (159/502) were RMR-TB and 10.2% (51/502) were RR-TB. Multivariable logistic regression analyses revealed that younger age, foreigners, and prior tuberculosis history were significantly associated with MDR/ RR-TB.
Conclusion
Rapid identification of rifampicin resistance targeting the high-risk populations, such as younger generations, foreign-born individuals, and previously treated patients are necessary for patient-centered care.
4.Post-blepharoplasty ectropion management: therapeutic benefits of platelet-rich plasma and polydeoxyribonucleotide injections
Hyung Woo WANG ; Han Earl LEE ; Seong Oh PARK ; Youn Hwan KIM
Archives of Aesthetic Plastic Surgery 2025;31(2):41-45
Background:
Ectropion, a common complication after lower blepharoplasty, causes significant patient discomfort and dissatisfaction, yet effective treatments remain lacking. In this study, we evaluated the efficacy of intradermal injections of polydeoxyribonucleotide (PDRN) and platelet-rich plasma (PRP) for scar regeneration and the rapid recovery of temporary ectropion following lower blepharoplasty.
Methods:
This retrospective study analyzed 21 cases of ectropion among 420 patients who underwent transcutaneous lower blepharoplasty between January 2020 and October 2022. PDRN and PRP were injected intradermally into the lower eyelid, with patients monitored at 1- or 2-week intervals. We investigated patient satisfaction, the total number of injections administered, and the time to complete improvement of the ectropion.
Results:
The average time for complete ectropion resolution was 9.3 weeks, with a relatively high patient satisfaction rating (mean, 4.3 out of 5). Ten primary cases responded well to a single injection, whereas all six patients with previous operations required two or more injections. The rate of improvement was faster than previously reported, likely due to the enhanced collagen synthesis and anti-inflammatory effects of PDRN, along with the tissue repair and angiogenic properties of PRP.
Conclusions
Intradermal injections of PDRN and PRP demonstrated promising results in rapidly resolving ectropion after lower blepharoplasty, thereby reducing patient discomfort and increasing overall satisfaction.
5.Long-term follow-up results and complications of breast-conserving surgery using multilayer acellular dermal matrix: a retrospective study
Jung Yeol SEO ; Kwang Sik SEO ; Jae Woo LEE ; Won Seok OH ; Seong Hwan BAE ; Youn Joo JUNG ; Su Bong NAM
Archives of Aesthetic Plastic Surgery 2025;31(1):10-16
Background:
The advantages of using an acellular dermal matrix (ADM) for implantbased breast reconstruction in breast cancer patients are well-documented across multiple studies. However, there have been no previous instances of using multilayered ADM for reconstruction following breast-conserving surgery (BCS). This study evaluated the outcomes of breast reconstruction employing multilayered ADM for volume replacement using a local glandular flap post-BCS, and aims to underscore the advantages of this surgical approach.
Methods:
Breast cancer patients who underwent BCS using several layers of ADM from August 2016 to December 2019 were retrospectively reviewed. Only patients with at least 3 years of follow-up were included in this study. The anticipated postoperative complications were breast deformity, seroma, hematoma, and infection.
Results:
Seventy-four patients were included in this study. Most patients experienced symptoms of hard palpation at the reconstruction site, which indicated the surface of the ADM inserted into the breast. Ten patients developed breast deformities, accounting for 13.5% of the cases, and required surgical correction. Other complications were less frequent: four patients (5.3%) had a confirmed seroma for 6 months or longer, two patients (2.6%) experienced fat necrosis, and one patient (1.3%) underwent re-operation to remove the ADM.
Conclusions
Reconstruction with a glandular flap and ADM following BCS is generally simpler and requires less surgical time compared to using a latissimus dorsi flap or other local flaps. Additionally, it avoids complications at the donor site, presenting a feasible surgical alternative for BCS in breasts with small defects.
6.Clinical evaluation and management of endometriosis: 2024 guideline for Korean patients from the Korean Society of Endometriosis
Hyun Joo LEE ; Sang-Hee YOON ; Jae Hoon LEE ; Youn-Jee CHUNG ; So Yun PARK ; Sung Woo KIM ; Yeon Hee HONG ; Sung Eun KIM ; Youjin KIM ; Sungwook CHUN ; Yong Jin NA
Obstetrics & Gynecology Science 2025;68(1):43-58
Endometriosis, a prevalent but debilitating condition affecting women, poses significant challenges in diagnosis and management. The current 2024 guideline, developed by the Korean Society of Endometriosis (KSE), builds upon the 2018 KSE guideline. This guideline aims to provide customized recommendations tailored to Korea’s unique clinical aspects and medical environment, and addresses key areas such as diagnosis, medical and surgical management, considerations for special populations, and its complex relationship with cancer.
7.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
8.Clinical Profiles of Multidrug-Resistant and Rifampicin-Monoresistant Tuberculosis in Korea, 2018–2021: A Nationwide Cross-Sectional Study
Jinsoo MIN ; Yousang KO ; Hyung Woo KIM ; Hyeon-Kyoung KOO ; Jee Youn OH ; Doosoo JEON ; Taehoon LEE ; Young-Chul KIM ; Sung Chul LIM ; Sung Soon LEE ; Jae Seuk PARK ; Ju Sang KIM
Tuberculosis and Respiratory Diseases 2025;88(1):159-169
Background:
This study aimed to identify the clinical characteristics of multidrug-resistant/ rifampicin-resistant tuberculosis (MDR/RR-TB) in the Republic of Korea.
Methods:
Data of notified people with tuberculosis between July 2018 and December 2021 were retrieved from the Korea Tuberculosis Cohort database. MDR/RR-TB was further categorized according to isoniazid susceptibility as follows: multidrug-resistant tuberculosis (MDR-TB), rifampicin-monoresistant tuberculosis (RMR-TB), and RR-TB if susceptibility to isoniazid was unknown. Multivariable logistic regression analysis was conducted to identify the factors associated with MDR/RR-TB.
Results:
Between 2018 and 2021, the proportion of MDR/RR-TB cases among all TB cases and TB cases with known drug susceptibility test results was 2.1% (502/24,447). The proportions of MDR/RR-TB and MDR-TB cases among TB cases with known drug susceptibility test results were 3.3% (502/15,071) and 1.9% (292/15,071), respectively. Among all cases of rifampicin resistance, 31.7% (159/502) were RMR-TB and 10.2% (51/502) were RR-TB. Multivariable logistic regression analyses revealed that younger age, foreigners, and prior tuberculosis history were significantly associated with MDR/ RR-TB.
Conclusion
Rapid identification of rifampicin resistance targeting the high-risk populations, such as younger generations, foreign-born individuals, and previously treated patients are necessary for patient-centered care.
9.Clinical evaluation and management of endometriosis: 2024 guideline for Korean patients from the Korean Society of Endometriosis
Hyun Joo LEE ; Sang-Hee YOON ; Jae Hoon LEE ; Youn-Jee CHUNG ; So Yun PARK ; Sung Woo KIM ; Yeon Hee HONG ; Sung Eun KIM ; Youjin KIM ; Sungwook CHUN ; Yong Jin NA
Obstetrics & Gynecology Science 2025;68(1):43-58
Endometriosis, a prevalent but debilitating condition affecting women, poses significant challenges in diagnosis and management. The current 2024 guideline, developed by the Korean Society of Endometriosis (KSE), builds upon the 2018 KSE guideline. This guideline aims to provide customized recommendations tailored to Korea’s unique clinical aspects and medical environment, and addresses key areas such as diagnosis, medical and surgical management, considerations for special populations, and its complex relationship with cancer.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail