1.Correlation of parent-child relationships with junior high school students bullying behaviors and social cohesion
YOU Lijun, LOU Chaohua, YU Chunyan, LIAN Qiguo, FANG Yuhang, TU Xiaowen, ZUO Xiayun
Chinese Journal of School Health 2025;46(8):1134-1137
Objective:
To examine the association between parent-child relationships and bullying behaviors among junior high school students, and to explore the moderating effect of community cohesion, so as to provide evidences for bullying intervention strategies.
Methods:
From November to December 2017, a cluster sampling method was used to survey 1 589 students in grades 6- 8 from three junior high schools in Jing an District,Shanghai. Anonymous electronic questionnaires collected data on parent-child relationships, community cohesion, and bullying behaviors. Multivariate Logistic regression analyzed the associations and moderation effects.
Results:
The prevalence of bullying behaviors among junior high school students was 7.80%. Spearman correlation analysis revealed negative associations between both parent-child relationships ( r =-0.13) and community cohesion ( r =-0.10) with bullying behaviors, while parent-child relationships positively correlated with community cohesion ( r =0.29) (all P <0.01). Junior high school students with positive parent-child relationships and higher perceived community cohesion showed lower risks of bullying behaviors ( OR=0.51, 95%CI =0.36-0.72; OR=0.58, 95%CI =0.45-0.76), with a significant interaction effect between the two factors (all P <0.05).
Conclusions
Positive parent-child relationships and community cohesion are negatively associated with bullying behaviors in middle school students. Supportive family relationships help reduce bullying, while stronger community cohesion enhances the protective effect of positive parent-child relationships against bullying.
2.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
3.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
4.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
5.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
6.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
7.Mid-term effectiveness of hip preservation in the reconstruction of ultrashort bone segments in the proximal femur with three-dimensional printed customized cementless intercalary endoprosthesis with an intra-neck curved stem.
Hongtao SHENG ; Yuqi ZHANG ; Qi YOU ; Taojun GONG ; Zhuangzhuang LI ; Xuanhong HE ; Fan TANG ; Yong ZHOU ; Yitian WANG ; Minxun LU ; Yi LUO ; Li MIN ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):970-977
OBJECTIVE:
To explore the design points of a three-dimensional (3D) printed customized cementless intercalary endoprosthesis with an intra-neck curved stem and to evaluate the key points and mid-term effectiveness of its application in the reconstruction of ultrashort bone segments in the proximal femur.
METHODS:
Between October 2015 and January 2021, 17 patients underwent reconstruction with a 3D printed-customized cementless intercalary endoprosthesis with an intra-neck curved stem. There were 11 males and 6 females, the age ranged from 10 to 76 years, with an average of 30.1 years. There were 9 cases of osteosarcoma, 4 cases of Ewing sarcoma, 2 cases of chondrosarcoma, 1 case of liposarcoma, and 1 case of myofibroblastoma. The disease duration was 5-14 months, with an average of 9.5 months. Enneking staging included 16 cases of stage ⅡB and 1 case of stage ⅢB. The distances from the center of the femoral head to the body midline and the acetabular apex were measured preoperatively on X-ray images. Additionally, the distances from the tip of the intra-neck curved stem to the body midline and the acetabular apex were measured at immediate postoperatively and last follow-up. The neck-shaft angle was also measured preoperatively, at immediate postoperatively, and at last follow-up. The status of osseointegration at the bone-prosthesis interface and bone growth into the prosthesis surface were assessed by X-ray films, CT, and Tomosynthesis-Shimadzu metal artefact reduction technology (T-SMART). The survival status of the patients, presence of local recurrence or distant metastasis, and occurrence of postoperative complications were assessed. The recovery of lower limb function was evaluated pre- and post-operatively using the Musculoskeletal Tumor Society (MSTS) scoring system, and pain relief was evaluated using the visual analogue scale (VAS) scores.
RESULTS:
The patient's femoral resection length was (163.1±57.5) mm, the remaining proximal femoral length was (69.6±9.3) mm, and the percentage of femoral resection length/total femoral length was 38.7%±14.6%. All 17 patients were followed up 25-86 months with an average of 58.1 months. During the follow-up, 1 patient died of lung metastasis at 46 months postoperatively, and the remaining 16 patients survived tumor-free. There was no complication such as periprosthetic infection, delayed incision healing, aseptic loosening, prosthesis fracture, or periprosthetic fracture. No evidence of micromotion or wear around the implanted stem of the prosthesis was detected in X-ray and T-SMART evaluations. There was no significant radiolucent lines, and radiographic evidence of bone ingrowth into the bone-prosthesis interface was observed in all stems. There was no significant difference in the distance from the tip of the curved stem to the body midline and the apex of the acetabulum at immediate postoperatively and last follow-up compared with the distance from the center of the femoral head to the body midline and the apex of the acetabulum before operation, respectively (P>0.05), and there was no significant difference in the above indexes between immediate postoperatively and last follow-up (P>0.05). The differences in the neck-shaft angle at various time points before and after operation were also not significant (P>0.05). At last follow-up, the MSTS score was 26.1±1.2 and the VAS score was 0.1±0.5, which were significantly improved when compared with those before operation [19.4±2.1 and 5.7±1.0, respectively] (t=14.735, P<0.001; t=21.301, P<0.001). At last follow-up, none of the patients walked with the aid of crutches or other walkers.
CONCLUSION
The 3D printed customized cementless intercalary endoprosthesis with an intra-neck curved stem is an effective method for reconstructing ultrashort bone segments in the proximal femur following malignant tumor resection. The operation is reliable, the postoperative lower limb function is satisfactory, and the incidence of complications is low.
Female
;
Male
;
Humans
;
Child
;
Adolescent
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Femur/surgery*
;
Lower Extremity
;
Bone-Implant Interface
;
Femur Head
;
Artificial Limbs
8.Application of RUNX2 gene over expression vector modified exosomes from BMSC combined with calcium carbonate scaffold system in bone defect.
You-Shun ZHAO ; Ping LIN ; Ying-Chun TU ; Tao AN ; Yu-Ping WU ; Xiao-Fei LI
China Journal of Orthopaedics and Traumatology 2022;35(4):379-386
OBJECTIVE:
To investigate the effect of RUNX2 gene overexpression vector modified exosomes derived from bone marrow mesenchymal stem cells (BMSCs) combined with calcium carbonate scaffold system in bone defect.
METHODS:
Rabbit BMSCs were used as the research object, and BMSCs were identified by flow cytometry. Construct RUNX2 gene overexpression vector, transfect BMSCs with lentivirus, and collect exosomes by ultracentrifugation. The morphology of exosomes was observed by transmission electron microscope, the expression of exosome marker CD63 was detected by Western blot, and the calcium carbonate scaffold was constructed by three chamber parallel automatic temperature control reaction system. According to whether the RUNX2 gene overexpression vector was transfected or not, the complex of BMSCs and calcium carbonate scaffold was divided into three groups, namely BMSCs group, RUNX2 overexpression group and exosome group. The osteogenic differentiation of BMSCs was detected by oil red O staining and RT-PCR. There were 9 clean adult healthy male New Zealand white rabbits, aged (12.97±1.21) months, with a body weight of (19.3±3.6) kg, with 3 rabbits in each group. The animal model of skull defect was constructed by surgical method, and the repair of bone defect was evaluated by imaging, he staining and Masson staining.
RESULTS:
The results of flow cytometry showed that the expression of CD29 protein, CD44 protein, CD11b protein and CD45 protein on the surface of BMSCs were 99.5%, 100%, 0.1% and 0.1%, respectively. Transmission electron microscopy showed that the exosomes were bilayer vesicles with a diameter of 50 to 150 nm. Western blot showed that the molecular marker CD63 of exosomes was positive. Oil red O staining showed that the osteogenic differentiation of BMSCs in exosome group was significantly higher than that in RUNX2 overexpression group and BMSCs group. The results of RT-PCR showed that the relative expressions of RUNX2, BMP-2 and ALP mRNA in BMSCs in exosome group were significantly higher than those in RUNX2 overexpression group and BMSCs group (P<0.05). The imaging results showed that the repair effect of skull defect in exosome group was better than that in RUNX2 overexpression group. HE staining and Masson staining showed that the repair effect of skull defect in exosome group was better than that in RUNX2 overexpression group (P<0.05). MSCs in exosome group was significantly higher than that in RUNX2 overexpression group and BMSCs group. The results of RT-PCR showed that the relative expressions of RUNX2, BMP-2 and ALP mRNA in BMSCs in exosome group were significantly higher than those in RUNX2 overexpression group and BMSCs group(P<0.05). The imaging results showed that the repair effect of skull defect in exosome group was better than that in RUNX2 overexpression group. HE staining and Masson staining showed that the repair effect of skull defect in exosome group was better than that in RUNX2 overexpression group(P<0.05).
CONCLUSION
Compared with RUNX2 gene overexpression vector transfection, extraction of exosomes directly can promote the differentiation of BMSCs into osteoblasts more efficiently, and the combination with calcium carbonate scaffold can better promote the healing of bone defects. So as to provide new ideas and methods for the clinical treatment of bone defects.
Animals
;
Calcium Carbonate/metabolism*
;
Core Binding Factor Alpha 1 Subunit/metabolism*
;
Exosomes/metabolism*
;
Humans
;
Male
;
Osteogenesis/genetics*
;
RNA, Messenger/metabolism*
;
Rabbits
9.Summary of best evidence for management of labor course induced by oxytocin drip in term pregnancy
Fengming TU ; Libo LUO ; Peihong WANG ; Xiangwei CHENG ; Caixia XIONG ; Fenfen YU ; Xike BAN ; Mengjie YOU ; Chen FANG
Chinese Journal of Practical Nursing 2022;38(33):2600-2606
Objective:To search, evaluate and summarize the best evidences related to induction of labor by oxytocin infusion in pregnant women with full-term pregnancy, and to provide reference for clinical practice in order to reduce the complications during labor, such as the proportion of instrument delivery, prolonged labor duration, uterine rupture, postpartum hemorrhage, etc. Standardize the management process of induction of labor with oxytocin, improve the satisfaction of pregnant women to participate in the decision of induction of labor, and improve the outcome of the newborn.Methods:Take the evidence-based nursing method, in view of the full-term pregnancy pregnant women oxytocin drip induced labor evidence-based labor management problems, nearly 10 years related literature retrieval from January 1st 2011 to April 9th, 2021, the Australian JBI evidence-based health care center of literature quality evaluation criteria and evidence classification system, all kinds of research evaluation and classification of retrieval.Results:Early detection to 340 articles, and eventually into 9 articles, including 1 clinical decision, 6 guides, 2 pieces of system evaluation. Totally 45 pieces evidences related to induction of labor by oxytocin infusion in pregnant women with full-term pregnancy were sumarized, including induced labor time, oxytocin side effects, induced labor before evaluation, induced labor of guardianship, infusion solution, such as health education, and other seven aspects.Conclusions:The present study summarized 45 pieces of best evidence on the management of labor induced by oxytocin infusion during term pregnancy, which provided some evidence-based basis for midwives, obstetric nurses and managers. Through the application of the best evidence, it is beneficial to improve the outcome of pregnant women in the neonatal perinatal period, standardize the process of inducing labor with oxytocin, and improve the quality of obstetric care.
10.Effectiveness and Safety of Moxibustion Robots on Primary Dysmenorrhea: A Randomized Controlled Pilot Trial.
Han-Rui ZHANG ; Hai-Yan TU ; Yu WANG ; Shi-Lin XIA ; Guo-You ZHAO ; Ting YANG ; Ying-Kun LI
Chinese journal of integrative medicine 2021;27(8):578-584
OBJECTIVE:
To conduct a pilot trial to explore the effectiveness and safety of moxibustion robots in treating primary dysmenorrhea (PD) and evaluate its feasibility in clinic.
METHODS:
A total of 70 participants with PD were allocated to either moxibustion robot (MR) group (35 cases) or manual moxibustion (MM) group (35 cases) using computer-generated randomization. One acupoint Guanyuan (CV 4) was selected to receive moxa heat stimulation. Two groups of participants were given 3 menstrual cycles of MM and MR treatment respectively (once a day, 5 days a session) and received another 3 menstrual cycles follow-up. The degree of pain was evaluated by short-form McGill pain questionnaire (SF-MPQ) and the symptoms of dysmenorrhea were evaluated by Cox Menstrual Symptom Scale (CMSS). The safety was measured by the occurrence rate of adverse events (AEs), including burns (blisters, red and swollen), itching, bowel changes, menstrual cycle disorder, menorrhagia and fatigue, etc. RESULTS: A total of 62 patients completed the trial, 32 in MR group and 30 in MM group. Compared with baseline, scores of SF-MPQ and CMSS significantly decreased in both groups (P<0.05), and no significant difference was observed between the two groups in the 3rd and 6th menstrual cycles (P>0.05). The total occurrence rate of AEs in MR group was 2.1%, which was significantly lower than MM group (7.2%, P<0.05).
CONCLUSIONS
MR has the same effect as MM at SF-MPQ and CMSS in patients with PD. However, MR is safer than MM (Trial registration No. ChiCTR1800018236).


Result Analysis
Print
Save
E-mail