1.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
2.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
3.Nasal Nitric Oxide as an Objective Evaluation Tool for Treatment Response in Chronic Rhinitis
Sangeun LEE ; Su Mi SEONG ; Hyeop OH ; Jihun YOON ; Bo Hae KIM ; Joo Hyun PARK ; Yun-Sung LIM ; Chang Gun CHO ; Seok-Won PARK ; Jin Youp KIM
Journal of Rhinology 2025;32(1):40-47
Background and Objectives:
Inconsistencies in nasal nitric oxide (nNO) values, due to anatomical variations and comorbidities, challenge the accurate assessment of upper airway inflammation severity. We hypothesized that changes in nNO levels following treatment for chronic rhinitis would be consistent and provide relative value. This study aimed to evaluate the correlation between changes in nNO levels and symptomatic improvements following treatment for chronic rhinitis.
Methods:
This prospective observational study included 46 participants diagnosed with chronic rhinitis between December 2021 and November 2023. nNO measurements, evaluations of four nasal and two ocular symptoms, and quality of life questionnaires were conducted at baseline and after one month of treatment. Baseline laboratory tests included serum total immunoglobulin E levels, blood eosinophil percentages, and skin prick tests.
Results:
The Total Nasal Symptom Score (TNSS), TNSS with ocular symptoms (TNSS eye), and Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ) scores significantly decreased following treatment (all p<0.001). nNO levels also decreased significantly after treatment (p=0.036). Moreover, changes in nNO were significantly correlated with changes in TNSS, TNSS eye, and RQLQ scores (p=0.047, r=0.294; p=0.021, r=0.340; and p=0.004, r=0.419, respectively).
Conclusion
In patients with chronic rhinitis, changes in TNSS, TNSS eye, and RQLQ scores were correlated with changes in nNO levels after treatment. nNO may serve as a potential objective evaluation tool for chronic rhinitis, particularly in patients who have difficulty reporting symptoms.
4.Congenital Contractures of the Limbs and Face, Hypotonia, and Developmental Delay (CLIFAHDD) Associated with a De Novo Missense Variant in NALCN: The First Korean Case Report
Yoon Hee JO ; Yoo Jung LEE ; Juhyun KONG ; Yun-Jin LEE ; Sang Ook NAM ; Young Mi KIM
Annals of Child Neurology 2025;33(1):34-37
5.The kinetics of nucleolar precursor bodies clustering at the pronuclei interface: Positive correlations with the morphokinetic characteristics of cleaving embryos and euploidy in preimplantation genetic testing programs
Hwa Soon OH ; Jung Mi JANG ; Hye Jin YOON ; Chang Woo CHOO ; Kyung Sil LIM ; Jin Ho LIM ; Yong-Pil CHEON
Clinical and Experimental Reproductive Medicine 2025;52(2):150-156
Objective:
This study investigated potential relationships between the kinetics of nucleolar precursor bodies (NPBs) in the pronucleus and developmental morphokinetics and euploidy in human preimplantation genetic testing for aneuploidy (PGT-A) cycles.
Methods:
The morphokinetic analysis of 200 blastocysts obtained from 53 PGT-A cycles was performed retrospectively in a time-lapse incubator. At the time of pronuclear breakdown (PNBD), we categorized the blastocysts into two groups based on the kinetic degree of clustering NPBs at the interface of the two pronuclei: clustered NPBs (CL) and non-clustered NPBs (NCL). We then compared morphokinetic parameters, abnormal behavioral events, and the rate of aneuploidy between the two groups.
Results:
Pronuclear fading and the first cleavage occurred earlier in the NCL group than in the CL group. However, the initiation of blastocyst formation and blastocyst expansion was delayed in the NCL group relative to the CL group. No differences were found in the rate of abnormal cleavage events, such as multinucleation at the 2-cell stage, direct cleavage from one to three cells, and from two to five cells between the CL and NCL groups. However, the fragmentation rate at the 8-cell stage was higher in the NCL group than in the CL group (10.3% vs. 1.9%, p<0.05). Additionally, the euploid rate in the CL group was significantly higher than in the NCL group (37.9% vs. 12.4%, p<0.05).
Conclusion
These results demonstrate the effectiveness of combining NPB clustering at PNBD with morphokinetics as a parameter for selecting embryos with higher developmental potential in in vitro fertilization.
6.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
7.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
8.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
9.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
10.The Impact of Clinical Competence and Perception of Clinical Ladder System on Organizational Commitment among Nurses at a General Tertiary Hospital
Yeon Hee SHIN ; Mi Ra LEE ; Sung Nam KIM ; Min Jung KIM ; Ae Jin KIM ; Hyun Ja KIM ; Ji Yoon KANG
Journal of Korean Academy of Nursing Administration 2025;31(1):120-131
Purpose:
This study aimed to evaluate the performance of a clinical ladder system in a tertiary hospital by examining how nurses' clinical competence and perceptions of the system affect organizational commitment.
Methods:
The study involved 394 nurses working at a tertiary hospital. Data were collected from May 3 to July 10, 2023, using a self-reported questionnaire. Statistical analyses, including descriptive statistics, independent t-tests, one-way ANOVA, Kruskal-Wallis test, Scheffé post-hoc test, Pearson correlation, and hierarchical regression analysis, were performed using SPSS 27.0.
Results:
Nurses who applied for promotion to the CN III level and current CN III nurses reported higher clinical competence, perceptions of the clinical ladder system, and organizational commitment than those who did not and those at lower levels (p<.001). A positive correlation existed among all independent variables.Controlling for general characteristics, the effects of clinical competence and perceptions of the clinical ladder system explained 49% of organizational commitment variance (Adjusted R 2 =.49, F=33.43, p<.001).
Conclusion
Greater clinical competence and positive perceptions of the clinical ladder system are likely to enhance organizational commitment, emphasizing its effectiveness in fostering better organizational outcomes.

Result Analysis
Print
Save
E-mail