1.Nasal Nitric Oxide as an Objective Evaluation Tool for Treatment Response in Chronic Rhinitis
Sangeun LEE ; Su Mi SEONG ; Hyeop OH ; Jihun YOON ; Bo Hae KIM ; Joo Hyun PARK ; Yun-Sung LIM ; Chang Gun CHO ; Seok-Won PARK ; Jin Youp KIM
Journal of Rhinology 2025;32(1):40-47
Background and Objectives:
Inconsistencies in nasal nitric oxide (nNO) values, due to anatomical variations and comorbidities, challenge the accurate assessment of upper airway inflammation severity. We hypothesized that changes in nNO levels following treatment for chronic rhinitis would be consistent and provide relative value. This study aimed to evaluate the correlation between changes in nNO levels and symptomatic improvements following treatment for chronic rhinitis.
Methods:
This prospective observational study included 46 participants diagnosed with chronic rhinitis between December 2021 and November 2023. nNO measurements, evaluations of four nasal and two ocular symptoms, and quality of life questionnaires were conducted at baseline and after one month of treatment. Baseline laboratory tests included serum total immunoglobulin E levels, blood eosinophil percentages, and skin prick tests.
Results:
The Total Nasal Symptom Score (TNSS), TNSS with ocular symptoms (TNSS eye), and Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ) scores significantly decreased following treatment (all p<0.001). nNO levels also decreased significantly after treatment (p=0.036). Moreover, changes in nNO were significantly correlated with changes in TNSS, TNSS eye, and RQLQ scores (p=0.047, r=0.294; p=0.021, r=0.340; and p=0.004, r=0.419, respectively).
Conclusion
In patients with chronic rhinitis, changes in TNSS, TNSS eye, and RQLQ scores were correlated with changes in nNO levels after treatment. nNO may serve as a potential objective evaluation tool for chronic rhinitis, particularly in patients who have difficulty reporting symptoms.
2.The Korean Organ Transplant Registry (KOTRY): Third Official Adult Heart Transplant Report
Hyo-In CHOI ; Sang Eun LEE ; Junho HYUN ; Darae KIM ; Dong-Ju CHOI ; Eun-Seok JEON ; Hae-Young LEE ; Hyun-Jai CHO ; Hyungseop KIM ; In-Cheol KIM ; Jaewon OH ; Minjae YOON ; Jin Joo PARK ; Jin-Oh CHOI ; Min Ho JU ; Seok-Min KANG ; Soo Yong LEE ; Sung-Ho JUNG ; Jae-Joong KIM
Korean Circulation Journal 2025;55(2):79-96
Background and Objectives:
The Korean Organ Transplant Registry (KOTRY) provided data for this third official report on adult heart transplantation (HT), including information from 709 recipients.
Methods:
Data from HTs performed at seven major centers in Korea between March 2014 and December 2020 were analyzed, focusing on immunosuppression, acute rejection, cardiac allograft vasculopathy (CAV), post-transplant survival, and mechanical circulatory support (MCS) usage.
Results:
The median ages of the recipients and donors were 56.0 and 43.0 years, respectively.Cardiomyopathy and ischemic heart disease were the most common preceding conditions for HT. A significant portion of patients underwent HT at waiting list status 1 and 0. In the multivariate analysis, a predicted heart mass mismatch was associated with a higher risk of 1-year mortality. Patients over 70 years old had a significantly increased risk of 6-year mortality. The risk of CAV was higher for male donors and donors older than 45 years. Acute rejection was more likely in patients with panel reactive antibody levels above 80%, while statin use was associated with a reduced risk. The employment of left ventricular assist device as a bridge to transplantation increased from 2.17% to 22.4%. Pre-transplant extra-corporeal membrane oxygenation was associated with worse post-transplant survival.
Conclusions
In this third KOTRY report, we analyzed changes in the characteristics of adult HT recipients and donors and their impact on post-transplant outcomes. The most notable discovery was the increased use of MCS before HT and their impact on post-transplant outcomes.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.The Korean Organ Transplant Registry (KOTRY): Third Official Adult Heart Transplant Report
Hyo-In CHOI ; Sang Eun LEE ; Junho HYUN ; Darae KIM ; Dong-Ju CHOI ; Eun-Seok JEON ; Hae-Young LEE ; Hyun-Jai CHO ; Hyungseop KIM ; In-Cheol KIM ; Jaewon OH ; Minjae YOON ; Jin Joo PARK ; Jin-Oh CHOI ; Min Ho JU ; Seok-Min KANG ; Soo Yong LEE ; Sung-Ho JUNG ; Jae-Joong KIM
Korean Circulation Journal 2025;55(2):79-96
Background and Objectives:
The Korean Organ Transplant Registry (KOTRY) provided data for this third official report on adult heart transplantation (HT), including information from 709 recipients.
Methods:
Data from HTs performed at seven major centers in Korea between March 2014 and December 2020 were analyzed, focusing on immunosuppression, acute rejection, cardiac allograft vasculopathy (CAV), post-transplant survival, and mechanical circulatory support (MCS) usage.
Results:
The median ages of the recipients and donors were 56.0 and 43.0 years, respectively.Cardiomyopathy and ischemic heart disease were the most common preceding conditions for HT. A significant portion of patients underwent HT at waiting list status 1 and 0. In the multivariate analysis, a predicted heart mass mismatch was associated with a higher risk of 1-year mortality. Patients over 70 years old had a significantly increased risk of 6-year mortality. The risk of CAV was higher for male donors and donors older than 45 years. Acute rejection was more likely in patients with panel reactive antibody levels above 80%, while statin use was associated with a reduced risk. The employment of left ventricular assist device as a bridge to transplantation increased from 2.17% to 22.4%. Pre-transplant extra-corporeal membrane oxygenation was associated with worse post-transplant survival.
Conclusions
In this third KOTRY report, we analyzed changes in the characteristics of adult HT recipients and donors and their impact on post-transplant outcomes. The most notable discovery was the increased use of MCS before HT and their impact on post-transplant outcomes.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
9.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.
10.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.

Result Analysis
Print
Save
E-mail