1.The multi-center mid-term clinical outcomes of combined complete preservation of chordal structure mitral valve replacement with total anatomic complete arterial myocardial revascularization for coronary patients with moderate-to-severe or severe ischemic mitral regurgitation
Ke GUO ; Xujun CHEN ; Baoshi ZHENG ; Chao SHI ; Keli HUANG ; Yong CAO ; Chengquan LIAO ; Jingwei CHEN ; Yu LIN ; Chengxin LIU ; Quansheng CAO ; Lin SHEN ; Zhendong WANG
Chinese Journal of Surgery 2025;63(1):58-67
Objective:To evaluate the clinical outcomes of combined complete preservation of chordal structure mitral valve replacement (C-MVR) with total anatomical arterial myocardial revascularization (TACR) in coronary patients with moderate-to-severe or severe ischemic mitral regurgitation (IMR).Methods:This is a retrospective multi-center case series study. Data were retrospectively collected from 127 patients with coronary artery disease with moderate to severe or severe IMR who received TACR with C-MVR from July 2015 to April 2024 in 13 hospitals in China. There were 90 males and 37 females, aged (56.5±10.7) years (range: 33 to 74 years). Perioperative data and follow-up data including left ventricular ejection fraction, left ventricular end-diastolic diameter, and patency rate of arterial grafts of patients were collected. Comparisons were made using paired sample t-test or χ2 test. Results:In this cohort of 127 patients, 67 underwent concurrent tricuspid valve repair. During surgery, 113 grafts of the left internal mammary artery (LIMA), 127 grafts of the left radial artery, 80 grafts of the right radial artery, and 110 grafts of the right internal mammary artery (RIMA) were harvested. The number of the distal anastomosis was 4.2±0.4 (range: 3 to 5). The aortic cross-clamp time and cardiopulmonary bypass time were (97.5±23.4) minutes (range: 90 to 161 minutes) and (145.4±19.2) minutes (range: 101 to 210 minutes), respectively. There was one operative death. Intraoperative placement of an intra-aortic balloon pump was performed in 21 patients to improve the left ventricular ejection. No sternal ischemic occurred. All patients completed follow-up, with a mean follow-up period of (64.3±7.5) months (range: 4 to 110 months). No major cerebrovascular events occurred during the follow-up period, and all patients survived. Left ventricular ejection fraction improved postoperatively (55.0%±5.3% vs. 41.0%±15.3%, t=17.23, P<0.01). The proportion of patients with New York Heart Association functional class ≤2 increased postoperatively (23.6% (30/127) vs. 87.3% (110/126), χ2=103.77, P<0.01). The proportion of patients with Canadian Cardiovascular Society Angina Classification ≤3 decreased postoperatively (4.8% (6/126) vs. 78.7% (100/127), χ2=142.19, P<0.01). The left ventricular end-diastolic diameter decreased postoperatively ((5.70±4.50) cm vs. (6.10±0.23) cm, t=12.15, P<0.01). Coronary multi-detector computed tomography angiography (MDCTA) follow-up was conducted for (60.5±11.7) months (range: 6 to 109 months) postoperatively. MDCTA confirmed the patency rates of the grafts: 96.4% (108/112) for the LIMA grafts, 88.9% (112/126) for the left radial artery grafts, 93.7% (74/79) for the right radial artery grafts, and 90.9% (100/110) for the free RIMA grafts. No significant differences in graft patency rates were observed between the arterial grafts ( χ2=5.24, P=0.155). Conclusion:The results of this multi-centre study demonstrate satisfactory mid-term results of C-MVR with TACR for the treatment of coronary artery disease with moderate to severe or severe IMR.
2.The multi-center mid-term clinical outcomes of combined complete preservation of chordal structure mitral valve replacement with total anatomic complete arterial myocardial revascularization for coronary patients with moderate-to-severe or severe ischemic mitral regurgitation
Ke GUO ; Xujun CHEN ; Baoshi ZHENG ; Chao SHI ; Keli HUANG ; Yong CAO ; Chengquan LIAO ; Jingwei CHEN ; Yu LIN ; Chengxin LIU ; Quansheng CAO ; Lin SHEN ; Zhendong WANG
Chinese Journal of Surgery 2025;63(1):58-67
Objective:To evaluate the clinical outcomes of combined complete preservation of chordal structure mitral valve replacement (C-MVR) with total anatomical arterial myocardial revascularization (TACR) in coronary patients with moderate-to-severe or severe ischemic mitral regurgitation (IMR).Methods:This is a retrospective multi-center case series study. Data were retrospectively collected from 127 patients with coronary artery disease with moderate to severe or severe IMR who received TACR with C-MVR from July 2015 to April 2024 in 13 hospitals in China. There were 90 males and 37 females, aged (56.5±10.7) years (range: 33 to 74 years). Perioperative data and follow-up data including left ventricular ejection fraction, left ventricular end-diastolic diameter, and patency rate of arterial grafts of patients were collected. Comparisons were made using paired sample t-test or χ2 test. Results:In this cohort of 127 patients, 67 underwent concurrent tricuspid valve repair. During surgery, 113 grafts of the left internal mammary artery (LIMA), 127 grafts of the left radial artery, 80 grafts of the right radial artery, and 110 grafts of the right internal mammary artery (RIMA) were harvested. The number of the distal anastomosis was 4.2±0.4 (range: 3 to 5). The aortic cross-clamp time and cardiopulmonary bypass time were (97.5±23.4) minutes (range: 90 to 161 minutes) and (145.4±19.2) minutes (range: 101 to 210 minutes), respectively. There was one operative death. Intraoperative placement of an intra-aortic balloon pump was performed in 21 patients to improve the left ventricular ejection. No sternal ischemic occurred. All patients completed follow-up, with a mean follow-up period of (64.3±7.5) months (range: 4 to 110 months). No major cerebrovascular events occurred during the follow-up period, and all patients survived. Left ventricular ejection fraction improved postoperatively (55.0%±5.3% vs. 41.0%±15.3%, t=17.23, P<0.01). The proportion of patients with New York Heart Association functional class ≤2 increased postoperatively (23.6% (30/127) vs. 87.3% (110/126), χ2=103.77, P<0.01). The proportion of patients with Canadian Cardiovascular Society Angina Classification ≤3 decreased postoperatively (4.8% (6/126) vs. 78.7% (100/127), χ2=142.19, P<0.01). The left ventricular end-diastolic diameter decreased postoperatively ((5.70±4.50) cm vs. (6.10±0.23) cm, t=12.15, P<0.01). Coronary multi-detector computed tomography angiography (MDCTA) follow-up was conducted for (60.5±11.7) months (range: 6 to 109 months) postoperatively. MDCTA confirmed the patency rates of the grafts: 96.4% (108/112) for the LIMA grafts, 88.9% (112/126) for the left radial artery grafts, 93.7% (74/79) for the right radial artery grafts, and 90.9% (100/110) for the free RIMA grafts. No significant differences in graft patency rates were observed between the arterial grafts ( χ2=5.24, P=0.155). Conclusion:The results of this multi-centre study demonstrate satisfactory mid-term results of C-MVR with TACR for the treatment of coronary artery disease with moderate to severe or severe IMR.
3.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
4.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
5.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
6.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
7.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
8.Expert consensus on the diagnosis and treatment of osteoporotic proximal humeral fracture with integrated traditional Chinese and Western medicine (version 2024)
Xiao CHEN ; Hao ZHANG ; Man WANG ; Guangchao WANG ; Jin CUI ; Wencai ZHANG ; Fengjin ZHOU ; Qiang YANG ; Guohui LIU ; Zhongmin SHI ; Lili YANG ; Zhiwei WANG ; Guixin SUN ; Biao CHENG ; Ming CAI ; Haodong LIN ; Hongxing SHEN ; Hao SHEN ; Yunfei ZHANG ; Fuxin WEI ; Feng NIU ; Chao FANG ; Huiwen CHEN ; Shaojun SONG ; Yong WANG ; Jun LIN ; Yuhai MA ; Wei CHEN ; Nan CHEN ; Zhiyong HOU ; Xin WANG ; Aiyuan WANG ; Zhen GENG ; Kainan LI ; Dongliang WANG ; Fanfu FANG ; Jiacan SU
Chinese Journal of Trauma 2024;40(3):193-205
Osteoporotic proximal humeral fracture (OPHF) is one of the common osteoporotic fractures in the aged, with an incidence only lower than vertebral compression fracture, hip fracture, and distal radius fracture. OPHF, secondary to osteoporosis and characterized by poor bone quality, comminuted fracture pattern, slow healing, and severely impaired shoulder joint function, poses a big challenge to the current clinical diagnosis and treatment. In the field of diagnosis, treatment, and rehabilitation of OPHF, traditional Chinese and Western medicine have accumulated rich experience and evidence from evidence-based medicine and achieved favorable outcomes. However, there is still a lack of guidance from a relevant consensus as to how to integrate the advantages of the two medical systems and achieve the integrated diagnosis and treatment. To promote the diagnosis and treatment of OPHF with integrated traditional Chinese and Western medicine, relevant experts from Orthopedic Expert Committee of Geriatric Branch of Chinese Association of Gerontology and Geriatrics, Youth Osteoporosis Group of Orthopedic Branch of Chinese Medical Association, Osteoporosis Group of Orthopedic Surgeon Branch of Chinese Medical Doctor Association, and Osteoporosis Committee of Shanghai Association of Integrated Traditional Chinese and Western Medicine have been organized to formulate Expert consensus on the diagnosis and treatment of osteoporotic proximal humeral fracture with integrated traditional Chinese and Western medicine ( version 2024) by searching related literatures and based on the evidences from evidence-based medicine. This consensus consists of 13 recommendations about the diagnosis, treatment and rehabilitation of OPHF with integrated traditional Chinese medicine and Western medicine, aimed at standardizing, systematizing, and personalizing the diagnosis and treatment of OPHF with integrated traditional Chinse and Western medicine to improve the patients ′ function.
9.Effects of sodium acetate on lowering uric acid and renal protection in mice with hyperuricemic nephropathy
Xue-Man LIN ; Shi-Qi ZHONG ; Yong-Mei LI ; Xiao-Yi QIN ; He-Yang JIANG ; Jia-Xin ZHOU ; Jian-Xin PANG ; Ting WU
The Chinese Journal of Clinical Pharmacology 2024;40(15):2222-2226
Objective To investigate the renal protective effect and mechanism of sodium acetate(Ace)on hyperuricemic nephropathy(HN)in mice.Methods Uric acid nephropathy mice model was prepared by intraperitoneal injection of potassium oxonate combined with adenine gavage.Mice were divided into blank control group(0.9%NaCl+0.5%carboxymethyl cellulose sodium),Ace group(200 mmol·L-1 Ace+0.5%carboxymethyl cellulose sodium),model group(0.9%NaCl+350 mg·kg-1 potassium oxonate+70 mg·kg-1 adenine),and experimental group(based on model group with additional 200 mmol·L-1 Ace).Serum and urine uric acid(UA)and serum creatinine(SCr)levels were observed in each group.Real-time fluorescence quantitative reverse transcription-polymerase chain reaction(qRT-PCR)was used to detect the expression levels of kidney injury molecule-1(Kim-1)and anti-aging gene Klotho,renal fibrosis markers Collagen Ⅰ and Fibronectin,intestinal inflammation-related factors interleukin-1 β(IL-1 β),and mRNA expression levels of tight junction proteins Zo-1.Results The serum UA levels of blank control group,Ace group,model group,and experimental group mice were(259.52±24.40),(227.71±35.91),(604.06±73.55),and(496.24±30.16)μmol·L-1,respectively;SCr levels were(16.85±0.40),(16.18±0.94),(22.38±1.56),and(19.78±1.43)μmol·L-1;Kim-1 mRNA relative expression levels were 1.04±0.25,1.17±0.28,13.00±2.87,and 4.24±3.92;Klotho mRNA relative expression levels were 1.04±0.15,1.02±0.18,0.43±0.12,and 0.69±0.12;Collagen Ⅰ mRNA relative expression levels were 1.05±0.15,1.02±0.18,3.19±1.09,and 1.61±0.55;Fibronectin mRNA relative expression levels were 1.07±0.18,1.02±0.25,7.86±2.40,and 3.34±2.10;intestinal IL-1β mRNA relative expression levels were 1.00±0.01,1.01±0.03,2.55±0.63,and 1.21±0.28;intestinal Zo-1 mRNA relative expression levels were 1.00±0.07,1.07±0.09,0.54±0.20,and 0.92±0.17.The above indicators in blank control group compared with model group,and experimental group compared with model group,all showed statistically significant differences(P<0.05,P<0.01,P<0.001).Conclusion Sodium acetate can effectively reduce UA levels in HN mice,significantly improve renal injury and fibrosis,and its mechanism may be related to the improvement of intestinal inflammatory response and up-regulation of intestinal Zo-1/Occuludin pathway to reduce intestinal mucosal permeability.
10.Detection of Water Distribution in Plant Leaves Using Thermoacoustic Imaging
Shi-Meng XIE ; Yong-Hui TANG ; Lin HUANG
Progress in Biochemistry and Biophysics 2024;51(8):1963-1970
ObjectiveThe distribution of water content in plant leaves is an important indicator for measuring plant physiology and biochemistry, and it is also an important basis for formulating drought resistance strategies in the field of agricultural science. Microwave imaging has high contrast and sensitivity in the distribution and variation of water content, while ultrasound imaging has high resolution. Based on this, this paper proposes a non-destructive microwave thermoacoustic imaging (TAI) technology that combines the advantages of microwave and ultrasound imaging, and uses this technology to carry out non-destructive testing research on the distribution of plant leaf water content, which is of great significance for achieving precise irrigation, developing water-saving agriculture, and improving water resource utilization. MethodsThis study constructs a two-dimensional transmissive TAI system with an excitation frequency of 3.0 GHz and a lateral resolution of 0.406 μm. Based on active heating technology (150°C hot air, 90 s), 3 sets of mandala leaf moisture loss processes were simulated, and their TAI images were quantitatively analyzed. ResultsThe results showed that heating caused local moisture loss and reduced thermoacoustic signals, verifying the feasibility of non-destructive detection of plant leaf water content changes based on TAI, which achieves non-destructive detection of water content distribution in leaves of Datura, Crassocephalum crepidioides and Perilla. The results are consistent with magnetic resonance imaging (MRI). ConclusionThis study contributes to achieve precise irrigation and provides technical support for studying the response characteristics of plants to the environment under normal and stress environments. Especially when combined with non-contact ultrasound detection technology, remote sensing of plant leaf water content can be achieved, which has more practical value.

Result Analysis
Print
Save