1.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
2.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
4.Bisphenol Analogs Downregulate the Self-Renewal Potential of Spermatogonial Stem Cells
Seo-Hee KIM ; Seung Hee SHIN ; Seok-Man KIM ; Sang-Eun JUNG ; Beom-Jin SHIN ; Jin Seop AHN ; Kyoung Taek LIM ; Dong-Hwan KIM ; Kichoon LEE ; Buom-Yong RYU
The World Journal of Men's Health 2025;43(1):154-165
Purpose:
In this study, we investigated the effect of bisphenol-A (BPA) and its major analogs, bisphenol-F (BPF), and bisphenol-S (BPS), on spermatogonial stem cells (SSCs) populations using in vitro SSC culture and in vivo transplantation models.
Materials and Methods:
SSCs enriched from 6- to 8-day-old C57BL/6-eGFP+ male mice testes were treated with varying concentrations of bisphenols for 7 days to examine bisphenol-derived cytotoxicity and changes in SSC characteristics. We utilized flow cytometry, immunocytochemistry, real-time quantitative reverse transcription-PCR, and western blot analysis. The functional alteration of SSCs was further investigated by examining donor SSC-derived spermatogenesis evaluation through in vivo transplantation and subsequent testis analysis.
Results:
BPF exhibited a similar inhibitory effect on SSCs as BPA, demonstrating a significant decrease in SSC survival, inhibition of proliferation, and induction of apoptosis. On the other hand, while BPS was comparatively weaker than BPA and BPF, it still showed significant SSC cytotoxicity. Importantly, SSCs exposed to BPA, BPF, and BPS exhibited a significant reduction in donor SSC-derived germ cell colonies per total number of cultured cells, indicating that, like BPA, BPF, and BPS can induce a comparable reduction in functional SSCs in the recipient animals. However, the progress of spermatogenesis, as evidenced by histochemistry and the expressions of PCNA and SSC specific markers, collectively indicates that BPA, BPF, and BPS may not adversely affect the spermatogenesis.
Conclusions
Our findings indicate that the major BPA substitutes, BPF and BPS, have significant cytotoxic effects on SSCs, similar to BPA. These effects may lead to a reduction in the functional self-renewal stem cell population and potential impacts on male fertility.
5.Immunologic Response and Effects of COVID-19Vaccines in Patients with Antineutrophil Cytoplasmic Antibody-Associated Vasculitis
Ki Hyun LEE ; Hyunsue DO ; Jun Yong CHOI ; Yong-Beom PARK ; Sinyoung KIM ; Sang-Won LEE ; Su Jin JEONG
Yonsei Medical Journal 2025;66(5):259-268
Purpose:
The immunological response and adverse effects of antineutrophil cytoplasmic antibody-associated vasculitis (AAV) in patients receiving coronavirus disease-2019 (COVID-19) vaccines remain unclear. We aimed to evaluate the effects of these vaccines on AAV disease activity.
Materials and Methods:
We reviewed the medical records of 52 patients with AAV who had received at least second doses of the COVID-19 vaccine and evaluated their immunogenicity by measuring the anti-spike (S) antibody (Ab) titer levels using the Roche Elecsys® immunoassay. Responses to the Birmingham Vasculitis Activity Score (BVAS) tool and 36-Item Short Form Survey before and after vaccination were obtained to assess AAV disease activity. Vaccine reactivity was measured using a standardized questionnaire.
Results:
We enrolled 52 patients with AAV. No differences were found between those who received second and third doses of vaccination in terms of AAV type, disease activity, vaccine type, or the use of immunosuppressive agents, including steroids. The median anti-S Ab titer was 3967.0 after third doses compared to 419.0 after second doses (p=0.001). Except for mycophenolate mofetil (MMF), when immunosuppressants were administered in conjunction with steroids, the Ab titer was higher after the third vaccination than that after the second dose. The BVAS remained unchanged before and after second and third doses. No life-threatening adverse events were reported.
Conclusion
Although COVID-19 vaccine may not produce sufficient antibodies in patients taking MMF, the vaccine did not exacerbate disease activity or cause severe side effects. Therefore, COVID-19 vaccines should be considered in patients with AAV.
6.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
7.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
8.Bisphenol Analogs Downregulate the Self-Renewal Potential of Spermatogonial Stem Cells
Seo-Hee KIM ; Seung Hee SHIN ; Seok-Man KIM ; Sang-Eun JUNG ; Beom-Jin SHIN ; Jin Seop AHN ; Kyoung Taek LIM ; Dong-Hwan KIM ; Kichoon LEE ; Buom-Yong RYU
The World Journal of Men's Health 2025;43(1):154-165
Purpose:
In this study, we investigated the effect of bisphenol-A (BPA) and its major analogs, bisphenol-F (BPF), and bisphenol-S (BPS), on spermatogonial stem cells (SSCs) populations using in vitro SSC culture and in vivo transplantation models.
Materials and Methods:
SSCs enriched from 6- to 8-day-old C57BL/6-eGFP+ male mice testes were treated with varying concentrations of bisphenols for 7 days to examine bisphenol-derived cytotoxicity and changes in SSC characteristics. We utilized flow cytometry, immunocytochemistry, real-time quantitative reverse transcription-PCR, and western blot analysis. The functional alteration of SSCs was further investigated by examining donor SSC-derived spermatogenesis evaluation through in vivo transplantation and subsequent testis analysis.
Results:
BPF exhibited a similar inhibitory effect on SSCs as BPA, demonstrating a significant decrease in SSC survival, inhibition of proliferation, and induction of apoptosis. On the other hand, while BPS was comparatively weaker than BPA and BPF, it still showed significant SSC cytotoxicity. Importantly, SSCs exposed to BPA, BPF, and BPS exhibited a significant reduction in donor SSC-derived germ cell colonies per total number of cultured cells, indicating that, like BPA, BPF, and BPS can induce a comparable reduction in functional SSCs in the recipient animals. However, the progress of spermatogenesis, as evidenced by histochemistry and the expressions of PCNA and SSC specific markers, collectively indicates that BPA, BPF, and BPS may not adversely affect the spermatogenesis.
Conclusions
Our findings indicate that the major BPA substitutes, BPF and BPS, have significant cytotoxic effects on SSCs, similar to BPA. These effects may lead to a reduction in the functional self-renewal stem cell population and potential impacts on male fertility.
9.Immunologic Response and Effects of COVID-19Vaccines in Patients with Antineutrophil Cytoplasmic Antibody-Associated Vasculitis
Ki Hyun LEE ; Hyunsue DO ; Jun Yong CHOI ; Yong-Beom PARK ; Sinyoung KIM ; Sang-Won LEE ; Su Jin JEONG
Yonsei Medical Journal 2025;66(5):259-268
Purpose:
The immunological response and adverse effects of antineutrophil cytoplasmic antibody-associated vasculitis (AAV) in patients receiving coronavirus disease-2019 (COVID-19) vaccines remain unclear. We aimed to evaluate the effects of these vaccines on AAV disease activity.
Materials and Methods:
We reviewed the medical records of 52 patients with AAV who had received at least second doses of the COVID-19 vaccine and evaluated their immunogenicity by measuring the anti-spike (S) antibody (Ab) titer levels using the Roche Elecsys® immunoassay. Responses to the Birmingham Vasculitis Activity Score (BVAS) tool and 36-Item Short Form Survey before and after vaccination were obtained to assess AAV disease activity. Vaccine reactivity was measured using a standardized questionnaire.
Results:
We enrolled 52 patients with AAV. No differences were found between those who received second and third doses of vaccination in terms of AAV type, disease activity, vaccine type, or the use of immunosuppressive agents, including steroids. The median anti-S Ab titer was 3967.0 after third doses compared to 419.0 after second doses (p=0.001). Except for mycophenolate mofetil (MMF), when immunosuppressants were administered in conjunction with steroids, the Ab titer was higher after the third vaccination than that after the second dose. The BVAS remained unchanged before and after second and third doses. No life-threatening adverse events were reported.
Conclusion
Although COVID-19 vaccine may not produce sufficient antibodies in patients taking MMF, the vaccine did not exacerbate disease activity or cause severe side effects. Therefore, COVID-19 vaccines should be considered in patients with AAV.
10.Long-Term Incidence of Gastrointestinal Bleeding Following Ischemic Stroke
Jun Yup KIM ; Beom Joon KIM ; Jihoon KANG ; Do Yeon KIM ; Moon-Ku HAN ; Seong-Eun KIM ; Heeyoung LEE ; Jong-Moo PARK ; Kyusik KANG ; Soo Joo LEE ; Jae Guk KIM ; Jae-Kwan CHA ; Dae-Hyun KIM ; Tai Hwan PARK ; Kyungbok LEE ; Hong-Kyun PARK ; Yong-Jin CHO ; Keun-Sik HONG ; Kang-Ho CHOI ; Joon-Tae KIM ; Dong-Eog KIM ; Jay Chol CHOI ; Mi-Sun OH ; Kyung-Ho YU ; Byung-Chul LEE ; Kwang-Yeol PARK ; Ji Sung LEE ; Sujung JANG ; Jae Eun CHAE ; Juneyoung LEE ; Min-Surk KYE ; Philip B. GORELICK ; Hee-Joon BAE ;
Journal of Stroke 2025;27(1):102-112
Background:
and Purpose Previous research on patients with acute ischemic stroke (AIS) has shown a 0.5% incidence of major gastrointestinal bleeding (GIB) requiring blood transfusion during hospitalization. The existing literature has insufficiently explored the long-term incidence in this population despite the decremental impact of GIB on stroke outcomes.
Methods:
We analyzed the data from a cohort of patients with AIS admitted to 14 hospitals as part of a nationwide multicenter prospective stroke registry between 2011 and 2013. These patients were followed up for up to 6 years. The occurrence of major GIB events, defined as GIB necessitating at least two units of blood transfusion, was tracked using the National Health Insurance Service claims data.
Results:
Among 10,818 patients with AIS (male, 59%; mean age, 68±13 years), 947 (8.8%) experienced 1,224 episodes of major GIB over a median follow-up duration of 3.1 years. Remarkably, 20% of 947 patients experienced multiple episodes of major GIB. The incidence peaked in the first month after AIS, reaching 19.2 per 100 person-years, and gradually decreased to approximately one-sixth of this rate by the 2nd year with subsequent stabilization. Multivariable analysis identified the following predictors of major GIB: anemia, estimated glomerular filtration rate <60 mL/min/1.73 m2 , and a 3-month modified Rankin Scale score of ≥4.
Conclusion
Patients with AIS are susceptible to major GIB, particularly in the first month after the onset of AIS, with the risk decreasing thereafter. Implementing preventive strategies may be important, especially for patients with anemia and impaired renal function at stroke onset and those with a disabling stroke.

Result Analysis
Print
Save
E-mail