1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Visualization of Borderline Coronary Artery Lesions by CT Angiography and Coronary Artery Disease Reporting and Data System
Hyewon PARK ; Yu-Whan OH ; Ki Yeol LEE ; Hwan Seok YONG ; Cherry KIM ; Sung Ho HWANG
Journal of the Korean Society of Radiology 2024;85(2):297-307
Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CADRAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.
6.Visualization of Borderline Coronary Artery Lesions by CT Angiography and Coronary Artery Disease Reporting and Data System
Hyewon PARK ; Yu-Whan OH ; Ki Yeol LEE ; Hwan Seok YONG ; Cherry KIM ; Sung Ho HWANG
Journal of the Korean Society of Radiology 2024;85(2):297-307
Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CADRAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.
7.Visualization of Borderline Coronary Artery Lesions by CT Angiography and Coronary Artery Disease Reporting and Data System
Hyewon PARK ; Yu-Whan OH ; Ki Yeol LEE ; Hwan Seok YONG ; Cherry KIM ; Sung Ho HWANG
Journal of the Korean Society of Radiology 2024;85(2):297-307
Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CADRAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.
8.JAK2 Loss Arising From Tumor-SpreadThrough-Air-Spaces (STAS) Promotes Tumor Progression by Suppressing CD8+ T Cells in Lung Adenocarcinoma:A Machine Learning Approach
Soohwan CHOI ; Hyung Suk KIM ; Kyueng-Whan MIN ; Yung-Kyun NOH ; Jeong-Yeon LEE ; Ji-Yong MOON ; Un Suk JUNG ; Mi Jung KWON ; Dong-Hoon KIM ; Byoung Kwan SON ; Jung Soo PYO ; Sun Kyun RO
Journal of Korean Medical Science 2024;39(2):e16-
Background:
Tumor spread through air spaces (STAS) is a recently discovered risk factor for lung adenocarcinoma (LUAD). The aim of this study was to investigate specific genetic alterations and anticancer immune responses related to STAS. By using a machine learning algorithm and drug screening in lung cancer cell lines, we analyzed the effect of Janus kinase 2 (JAK2) on the survival of patients with LUAD and possible drug candidates.
Methods:
This study included 566 patients with LUAD corresponding to clinicopathological and genetic data. For analyses of LUAD, we applied gene set enrichment analysis (GSEA), in silico cytometry, pathway network analysis, in vitro drug screening, and gradient boosting machine (GBM) analysis.
Results:
The patients with STAS had a shorter survival time than those without STAS (P < 0.001). We detected gene set-related downregulation of JAK2 associated with STAS using GSEA. Low JAK2 expression was related to poor prognosis and a low CD8+ T-cell fraction. In GBM, JAK2 showed improved survival prediction performance when it was added to other parameters (T stage, N stage, lymphovascular invasion, pleural invasion, tumor size). In drug screening, mirin, CCT007093, dihydroretenone, and ABT737 suppressed the growth of lung cancer cell lines with low JAK2 expression.
Conclusion
In LUAD, low JAK2 expression linked to the presence of STAS might serve as an unfavorable prognostic factor. A relationship between JAK2 and CD8+ T cells suggests that STAS is indirectly related to the anticancer immune response. These results may contribute to the design of future experimental research and drug development programs for LUAD with STAS.
9.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
Objective:
The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog).
Methods:
We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity.
Results:
The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively).
Conclusion
Our results demonstrate that the K-SCOPA-Cog has good reliability and validity.
10.KAAACI Allergic Rhinitis Guidelines: Part 2. Update in nonpharmacotherapy
Sang Chul PARK ; Soo Jie CHUNG ; Jeong-Hee CHOI ; Yong Ju LEE ; Hyeon-Jong YANG ; Do-Yang PARK ; Dong-Kyu KIM ; Il Hwan LEE ; Soo Whan KIM ; Do Hyun KIM ; Young Joon JUN ; Song-I YANG ; Minji KIM ; Gwanghui RYU ; Sung-Yoon KANG ; Sang Min LEE ; Mi-Ae KIM ; Hyun-Jung KIM ; Gil-Soon CHOI ; Hyun Jong LEE ; Hyo-Bin KIM ; Bong-Seong KIM
Allergy, Asthma & Respiratory Disease 2023;11(3):126-134
Allergic rhinitis is the most common chronic disease worldwide. Various upper airway symptoms lower quality of life, and due to the recurrent symptoms, multiple treatments are usually attempted rather than one definitive treatment. There are alternatives to medical (medication-based) and nonmedical treatments. A guideline is needed to understand allergic rhinitis and develop an appropriate treatment plan. We have developed guidelines for medical treatment based on previous reports. The current guidelines herein are associated with the “KAAACI Evidence-Based Guidelines for Allergic Rhinitis in Korea, Part 1: Update in pharmacotherapy” in which we aimed to provide evidence-based recommendations for the medical treatment of allergic rhinitis. Part 2 focuses on nonpharmacological management, including allergen-specific immunotherapy, subcutaneous or sublingual immunotherapy, nasal saline irrigation, environmental management strategies, companion animal management, and nasal turbinate surgery. The evidence to support the treatment efficacy, safety, and selection has been systematically reviewed. However, larger controlled studies are needed to elevate the level of evidence to select rational non-medical therapeutic options for patients with allergic rhinitis.

Result Analysis
Print
Save
E-mail